Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleClinical Investigations

64Cu-DOTA-Trastuzumab PET Imaging in Patients with HER2-Positive Breast Cancer

Kenji Tamura, Hiroaki Kurihara, Kan Yonemori, Hitoshi Tsuda, Junko Suzuki, Yuzuru Kono, Natsuki Honda, Makoto Kodaira, Harukaze Yamamoto, Mayu Yunokawa, Chikako Shimizu, Koki Hasegawa, Yousuke Kanayama, Satoshi Nozaki, Takayuki Kinoshita, Yasuhiro Wada, Shusaku Tazawa, Kazuhiro Takahashi, Yasuyoshi Watanabe and Yasuhiro Fujiwara
Journal of Nuclear Medicine November 2013, 54 (11) 1869-1875; DOI: https://doi.org/10.2967/jnumed.112.118612
Kenji Tamura
1Department of Breast and Medical Oncology, National Cancer Center Hospital, Tokyo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hiroaki Kurihara
2Department of Diagnostic Radiology, National Cancer Center Hospital, Tokyo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kan Yonemori
1Department of Breast and Medical Oncology, National Cancer Center Hospital, Tokyo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hitoshi Tsuda
3Department of Pathology and Clinical Laboratories, National Cancer Center Hospital, Tokyo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Junko Suzuki
4Department of Breast Surgery, National Cancer Center Hospital, Tokyo, Japan; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yuzuru Kono
2Department of Diagnostic Radiology, National Cancer Center Hospital, Tokyo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Natsuki Honda
2Department of Diagnostic Radiology, National Cancer Center Hospital, Tokyo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Makoto Kodaira
1Department of Breast and Medical Oncology, National Cancer Center Hospital, Tokyo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Harukaze Yamamoto
1Department of Breast and Medical Oncology, National Cancer Center Hospital, Tokyo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mayu Yunokawa
1Department of Breast and Medical Oncology, National Cancer Center Hospital, Tokyo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Chikako Shimizu
1Department of Breast and Medical Oncology, National Cancer Center Hospital, Tokyo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Koki Hasegawa
5RIKEN Center for Molecular Imaging Science, Hyogo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yousuke Kanayama
5RIKEN Center for Molecular Imaging Science, Hyogo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Satoshi Nozaki
5RIKEN Center for Molecular Imaging Science, Hyogo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Takayuki Kinoshita
4Department of Breast Surgery, National Cancer Center Hospital, Tokyo, Japan; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yasuhiro Wada
5RIKEN Center for Molecular Imaging Science, Hyogo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Shusaku Tazawa
5RIKEN Center for Molecular Imaging Science, Hyogo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kazuhiro Takahashi
5RIKEN Center for Molecular Imaging Science, Hyogo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yasuyoshi Watanabe
5RIKEN Center for Molecular Imaging Science, Hyogo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yasuhiro Fujiwara
1Department of Breast and Medical Oncology, National Cancer Center Hospital, Tokyo, Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Abstract

The purpose of this study was to determine the safety, distribution, internal dosimetry, and initial human epidermal growth factor receptor 2 (HER2)–positive tumor images of 64Cu-DOTA-trastuzumab in humans. Methods: PET was performed on 6 patients with primary or metastatic HER2-positive breast cancer at 1, 24, and 48 h after injection of approximately 130 MBq of the probe 64Cu-DOTA-trastuzumab. Radioactivity data were collected from the blood, urine, and normal-tissue samples of these 6 patients, and the multiorgan biodistribution and internal dosimetry of the probe were evaluated. Safety data were collected for all the patients after the administration of 64Cu-DOTA-trastuzumab and during the 1-wk follow-up period. Results: According to our results, the best timing for the assessment of 64Cu-DOTA-trastuzumab uptake by the tumor was 48 h after injection. Radiation exposure during 64Cu-DOTA-trastuzumab PET was equivalent to that during conventional 18F-FDG PET. The radioactivity in the blood was high, but uptake of 64Cu-DOTA-trastuzumab in normal tissues was low. In 2 patients, 64Cu-DOTA-trastuzumab PET showed brain metastases, indicative of blood–brain barrier disruptions. In 3 patients, 64Cu-DOTA-trastuzumab PET imaging also revealed primary breast tumors at the lesion sites initially identified by CT. Conclusion: The findings of this study indicated that 64Cu-DOTA-trastuzumab PET is feasible for the identification of HER2-positive lesions in patients with primary and metastatic breast cancer. The dosimetry and pharmacologic safety results were acceptable at the dose required for adequate PET imaging.

  • HER2-positive breast cancer
  • trastuzumab
  • PET
  • 64Cu
  • molecular imaging

The discovery of novel molecular targets for anticancer treatment has led to the development of several therapeutic antibodies. Molecular imaging using radiolabeled antibodies can noninvasively identify the presence of specific targets throughout the body. Trastuzumab, a humanized monoclonal antibody against human epidermal growth factor receptor 2 (HER2), is widely used as a standard treatment for HER2-positive breast cancer.

Targeting of HER2 with the monoclonal antibody trastuzumab is a well-established therapeutic strategy for HER2-positive breast cancer in neoadjuvant (1), adjuvant (2,3), and metastatic settings (4,5). Although HER2 expression is routinely determined using immunohistochemistry or FISH (6), technical problems can arise when lesions cannot be easily accessed by core-needle biopsy (7). In addition, HER2 expression can vary during the course of the disease (8) and even across tumor lesions within the same patient (9). Therefore, to overcome these problems, a novel technique such as PET molecular imaging is required for the noninvasive evaluation of HER2 expression.

Recently, several novel HER2 inhibitors have been developed, including lapatinib (10,11), a HER2 tyrosine kinase inhibitor, which has already been approved for relapsed HER2-positive breast cancer. Pertuzumab, a novel anti-HER2 humanized monoclonal antibody that inhibits receptor dimerization, has a mechanism of action that is complementary to that of trastuzumab. The combination of pertuzumab plus trastuzumab plus docetaxel as first-line treatment significantly prolonged progression-free survival, compared with placebo plus trastuzumab plus docetaxel (12). And progression-free and overall survival were significantly longer with trastuzumab emtansine, an antibody drug conjugate, than with lapatinib plus capecitabine after previous treatment with trastuzumab and a taxane (13). In contrast, some reports also suggest the efficacy of continuing trastuzumab after progression of metastatic breast cancer. Thus, monitoring the changes in HER2 expression in primary tumor and metastatic sites throughout the course of the disease might be helpful to determine the kind of HER2 inhibitors, or other non-HER2 inhibitors, that should be used in the different phases of treatment.

SPECT was initially used as a noninvasive imaging technique for HER2 (14,15). One study reported that SPECT with 111In-labeled trastuzumab found new HER2-positive metastatic lesions (15). This finding indicates that SPECT is potentially valuable as a clinical diagnostic tool, although this method does have limitations such as spatial resolution or sensitivity in deep tissues.

To overcome these issues, 124I- and 89Zr-labeled antibody/PET was evaluated in HER2-positive breast cancer (16–18). The first clinical trial using an 89Zr-labeled antibody was performed with U36, a chimeric monoclonal antibody, in head and neck squamous cell carcinoma patients (19). Next, an 89Zr-trastuzumab PET trial was conducted in metastatic HER2-positive breast cancer patients (20). 89Zr-trastuzumab PET allowed better visualization and semiquantification of uptake in HER2-positive lesions. Unfortunately, 111In, 124I, and 89Zr-trastuzumab, because of their long half-life (67.9, 100.2, and 78.4 h, respectively), resulted in high radiation exposure in patients. For example, the radiation doses of 111In-trastuzumab, 124I-antibody, and 89Zr-trastuzumab were 22, 24, and 18 mSv, respectively, which are 2.5 times higher than that of 18F-FDG PET (20–22). In contrast, the half-life of 64Cu is 12.7 h (23), suggesting that 64Cu-DOTA-trastuzumab PET could potentially achieve adequate tumor-tissue contrast with high resolution and low radiation exposure because of the shorter half-life of the radioisotope.

In the current study, we attempted to produce good-manufacturing-practice–level 64Cu-labeled trastuzumab with high specific radioactivity and to perform PET imaging with labeled antibodies not only for the detection of primary HER2-positive breast cancer but also for metastatic HER2-positive lesions.

In this clinical study, we evaluated the feasibility and plausible conditions for 64Cu-DOTA-trastuzumab PET imaging for the visualization and quantification of HER2-positive lesions in patients with HER2-positive breast cancer.

MATERIALS AND METHODS

General

All chemical reagents were obtained from commercial sources. This study was conducted according to a protocol approved by the institutional review board and an independent ethics committee of National Cancer Center Hospital. All patients signed a written informed consent form.

Preparation of 64Cu-DOTA-Trastuzumab

64Cu was produced from 64Ni metal powder (ISOFLEX USA) as described previously (24). Briefly, the 64Ni (p, n) 64Cu nuclear reaction was performed with 12-MeV proton irradiation using a small medical cyclotron (HM-12S; Sumitomo Heavy Industries. Ltd.). The beam current used was approximately 20 μA (3 h). Trastuzumab IgG (Herceptin; Chugai Pharmaceutical Co., Ltd.) was purified by ultrafiltration (Ultra 0.5 ml 50 k; Amicon) with phosphate-buffered saline (Nacalai Tesque). The obtained trastuzumab (592 μg, 4 nmol) in phosphate-buffered saline (552 μL) was added to 0.16 μg (400 nmol) of DOTA mono N-hydroxysuccinimide ester (Macrocyclics Inc.) and dissolved in water for injection (40 μL). After 3 h, crude DOTA-trastuzumab was purified with phosphate-buffered saline using a PD-10 column. The phosphate-buffered saline buffer, including DOTA-trastuzumab (100 μg, 0.7 nmol), was exchanged for a sodium acetate buffer (100 mM, pH 6.5) by filtration.

64Cu-DOTA-trastuzumab injection was prepared by adding 64CuCl2 (400–800 MBq; specific activity, 300–2,500 GBq/μmol) to acetate buffer (pH 6.5) solution containing DOTA-trastuzumab and incubating the solution for 1 h at 40°C. The reaction mixture was sterilized by filtration through a 0.22-μm Millex GV filter (Merck Millipore). All the procedures were performed under laminar airflow (class 100 air). The radiolabeling results revealed that the specific activity and radiochemical purity were approximately 350 GBq/μmol and 98%, respectively. Approximately 500 MBq of the final product were obtained by a single radiosynthesis.

64Cu-DOTA-trastuzumab injections passed quality control testing against the following specifications: radioactivity (>150 MBq), volume (3–4 mL), clarity (clear), color (none), pH (6–8), radiochemical purity (>95%), protein abundance (<100 μg), specific activity (>100 GBq/μmol), sterility (Japanese Pharmacopoeia), and endotoxin (<0.25 EU/mL). HER2 immunoreactivities (dissociation constants) of the final products were determined to be approximately 1 nM, as described previously (25), using a quartz-crystal microbalance (QCM, single Q0500; SCINICS) with analysis software (QCM1-2, version 1.22; SCINICS).

Patients

Patients included in this study had histologically confirmed invasive HER2-positive (immunohistochemistry 3+ or fluorescence in situ hybridization [FISH]–positive) breast carcinoma, at least 1 site of measurable disease, an Eastern Cooperative Oncology Group performance status of 0–1, and adequate organ function (neutrophil count ≥ 1,500/μL, platelet count ≥ 75,000/μL, hemoglobin concentration ≥ 9.0 g/dL, serum bilirubin ≤ 1.5 mg/dL, aspartate aminotransferase and alanine aminotransferase ≤ 100 IU/L, serum creatinine ≤ 1.5 mg/dL, baseline left ventricular ejection fraction > 60%) and were aged between 20 and 75 y. The main exclusion criteria were congestive heart failure, uncontrolled angina pectoris, arrhythmia, symptomatic infectious disease, severe bleeding, pulmonary fibrosis, obstructive bowel disease or severe diarrhea, symptomatic peripheral or cardiac effusion, and symptomatic brain metastasis.

PET Scanner and Protocol

Images were acquired with a Discovery 600 scanner (GE Healthcare). First, a scout image was acquired to determine the scanning field of the patient, using settings of 10 mA and 120 kV. Next, whole-body 16-slice helical CT and whole-body 3-dimensional PET acquisition were performed. For the whole-body PET/CT study, the scanning field ranged from head to foot. PET images were acquired at 14–16 bed positions with a 2- to 10-min acquisition per bed position, so that they covered the same field as that of whole-body CT. The acquired data were reconstructed as 192 × 192 matrix images (3.65 × 3.65 mm) using a 3-dimensional ordered-subsets expectation maximization algorithm (VUE Point Plus [GE Healthcare]; 32 iterations, 1 subset, and a postprocessing filter of 5 mm in full width at half maximum). PET image evaluation and quantification of the standardized uptake value (SUV) were performed using AW Volume Share 4.5 software (GE Healthcare). Regions of interest were delineated on the PET/CT images, and the maximum SUV was determined.

Safety Monitoring

All patients had received intravenous injections of 64Cu-DOTA-trastuzumab. After the injection, all patients were monitored for 30 min to detect any infusion-related anaphylactic reactions or adverse events. Safety data, including the recording of adverse events, changes in vital signs, physical examination findings, electrocardiogram findings, and laboratory parameters, were collected for all the patients after administration of 64Cu-DOTA-trastuzumab and throughout the 1-wk follow-up period. During PET/CT scanning procedures, vital signs, including blood pressure, temperature, and respiratory rate, were closely monitored and recorded.

Assessment of Feasibility

The whole-body PET/CT study was performed on 6 patients, and sets of images were collected at 1, 24, and 48 h after the injection to evaluate radioactivity distribution, internal dosimetry, and radiation exposure. The internal radiation dose was calculated on the basis of radioactivity data from blood, urinary excretion, and normal tissues of the heart, liver, spleen, kidneys, and other parts of the body at each time point using the OLINDA/EXM software (26).

To minimize radiation exposure and contamination of patients, visitors, and health care providers, a radiation survey of each of the 6 patients and the patient’s room was performed by collecting radioactivity data from the excreted urine, clothes, and linens from days 1–3 in the administrative area for radiotherapy at the National Cancer Center Hospital. The radiation dose rate was also evaluated at a distance of 1 m from the surface of each patient by a survey meter, immediately after the injection of 64Cu-DOTA-trastuzumab, to confirm the feasibility of using 64Cu-DOTA-trastuzumab PET/CT for outpatients.

RESULTS

Patient Characteristics

Between December 2010 and November 2011, 6 patients were enrolled in the current study. Patient characteristics are presented in Table 1. The median age of the patients was 58 y. The histologic type for almost all tumors was invasive ductal breast carcinoma, either solid tubular or scirrhous type. There was 1 lobular breast carcinoma. Five patients (83%) had HER2-positive tumors that were immunohistochemistry 3+, whereas 1 patient (17%) had HER2-positive tumors that were both immunohistochemistry 2+ and FISH-positive. Three primary cancers in stage IIA–IIB and 3 metastatic cancers with brain and hilar node metastases were detected. No infusion-related reactions or adverse events were observed during the study.

View this table:
  • View inline
  • View popup
TABLE 1

Patient Characteristics

Injection Dose and Safety Monitoring

The mean and SD of the administered mass of 64Cu-DOTA-trastuzumab was 86.2 ± 6.3 μg (range, 80.6–91.8 μg). The mean administered activity was 126 ± 8 MBq (range, 115–136 MBq). The administration of 64Cu-DOTA-trastuzumab was well tolerated by all subjects. No drug-related adverse events were reported for any of the patients included in this study. No clinically important trends indicative of a safety signal were noted for the laboratory parameters, vital signs, or electrocardiogram parameters.

Conditions for Imaging

The whole-body distribution of 64Cu-DOTA-trastuzumab in patient 4 is shown in Figure 1. Figure 2A shows typical decay-corrected time–activity curves for normal organ tissue at 1, 24, and 48 h after the injection for all 6 patients. Whole-body SUV was relatively stable, in the range of 0.8–1.0. SUV in blood at 1, 24, and 48 h after the injection showed high values of 8.3–11.1, 4.5–8.1, and 3.3–6.4, respectively. In contrast, SUV in the urinary bladder showed a rapid decrease approximately 24 h after the injection. The radioactivity voided into urine within 1 h after injection ranged from 2% to 5% of the injected activity, which was similar to the percentages of unlabeled 64Cu in the injected activity (Supplemental Table 1; supplemental materials are available at http://jnm.snmjournals.org). Biodistribution in the liver, spleen, and kidney was as expected for these well-perfused organs. The radioactivity in the liver was higher in patients 3 and 6, who had no history of trastuzumab treatment, than in the other patients. The target tumor uptake showed better contrast at 48 h after the injection than at 24 h after the injection (Fig. 2B). These findings indicate that the plausible timing for imaging in this series of measurement is 48 h after injection of 64Cu-DOTA-trastuzumab.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Whole-body 64Cu-DOTA-trastuzumab PET images at 1, 24, and 48 h after injection (patient 4).

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Regional time–activity curves of 64Cu-DOTA-trastuzumab in 6 patients. (A) SUVs in blood, urinary bladder, liver, kidney, spleen, and whole body were calculated from region-of-interest–based analysis for each tissue. SUV in blood was measured from region of interest of heart content. (B) SUVs in tumor and tumor-to-normal tissue ratio (TNR) were also calculated. In patient 6, SUV in tumor and TNR could not be calculated because of nonspecific high uptake of 64Cu-DOTA-trastuzumab within heart and large vessels.

Assessment of Feasibility

Internal dosimetry was evaluated in all 6 patients. The target radioactivity was 150 MBq, and the average radioactivity for the 6 patients was 126 MBq. The organ-absorbed and effective doses are shown in Table 2. The highest absorbed dose was in the heart wall, followed by the liver, spleen, and kidneys. The average of the effective dose was estimated to be 0.036 ± 0.009 mSv/MBq.

View this table:
  • View inline
  • View popup
TABLE 2

Organ-Absorbed Dose and Effective Dose Estimated from Whole-Body 64Cu-DOTA-Trastuzumab PET

Patient radiation surveys, conducted using a survey meter, revealed that the radiation dose rate at 1 m from the surface of each patient immediately after the injection of 64Cu-DOTA-trastuzumab was approximately 7–10 (μSv/h). The average decay-corrected radioactivity in urine samples collected within 24 h after injection of the probe was approximately 4.2 MBq (Table 3, urinary excretion). Radioactivity in urine samples obtained on days 2 and 3 decreased to less than 1 MBq. Radiation surveys of patient rooms revealed that the radioactivity of clothes and linens was at background levels.

View this table:
  • View inline
  • View popup
TABLE 3

Injected Radioactivity and Effective Dose for 6 Patients and Radiation Survey for Each Patient and Patient Room

Initial Analysis of Tumor PET Image with 64Cu-DOTA-Trastuzumab

Most of the HER2-positive lesions previously identified by CT, MR imaging, or bone scans could also be seen on the 64Cu-DOTA-trastuzumab PET scan at 48 h after the injection. In this pilot study, primary breast tumors that had been identified as HER2-positive by immunohistochemistry and FISH were clearly visualized by 64Cu-DOTA-trastuzumab PET imaging in 3 patients (Fig. 3). The smallest primary breast carcinoma lesion revealed by 64Cu-DOTA-trastuzumab PET imaging measured 2.0 × 2.0 cm on breast sonography (Table 1). Brain metastases were also visualized by 64Cu-DOTA-trastuzumab PET in 2 patients. In patient 1, with multiple brain metastases in the cerebellar hemisphere, the PET scan showed 64Cu-DOTA-trastuzumab accumulation in lesions that corresponded to those observed on MR imaging (Fig. 4A). In patient 4, 64Cu-DOTA-trastuzumab PET imaging could detect a solitary brain metastasis that had been identified in a similar location by MR imaging (Fig. 4B). A hilar lymph node metastasis located near the great vessels and heart in patient 6 was not detected by 64Cu-DOTA-trastuzumab PET imaging.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

64Cu-DOTA-trastuzumab PET images of HER2-positive primary breast tumor. Arrows show primary breast tumor in patient 3. Red regions indicate high uptake 64Cu-DOTA-trastuzumab in heart and blood vessels.

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

64Cu-DOTA-trastuzumab PET images of HER2-positive metastatic brain lesions (arrows). (A) Brain metastases were clearly visualized by 64Cu-DOTA-trastuzumab PET in patient 1. Significant uptake values were found in areas corresponding to brain metastatic lesions that were detected by MR imaging. Some brain metastases could not be detected on conventional CT. (B) In patient 4, 64Cu-DOTA-trastuzumab PET imaging could detect solitary brain metastasis that had also been identified in similar location by MR imaging.

DISCUSSION

This study, performed on humans for—to our knowledge—the first time, revealed that 64Cu-DOTA-trastuzumab PET imaging was safe and feasible even for outpatients and that the estimated effective dose was 0.036 mSv/MBq. The internal radiation dose of 64Cu-DOTA-trastuzumab PET absorbed by the patient was estimated to be 4.5 mSv (0.036 × 126). In contrast, the average effective dose in routine 18F-FDG PET is approximately 0.019 mSv/MBq, and target radioactivity per injection is 370–740 MBq (27). Therefore, the internal radiation dose absorbed by the patient per 18F-FDG PET scan was estimated to be 7.0–14 mSv (0.019 × 370–740), indicating that the internal radiation dose of 64Cu-DOTA-trastuzumab PET was lower than that of conventional 18F-FDG PET.

The pilot tumor images of 64Cu-DOTA-trastuzumab PET demonstrated successful tumor uptake and visualization of HER2-positive primary breast carcinoma and metastatic lesions in the brain. High SUV in the heart and blood vessels could reflect the biologic stability of trastuzumab in blood. The balance between the sustained accumulation of 64Cu-DOTA-trastuzumab in the tumors, blood clearance of injected 64Cu-DOTA-trastuzumab, and radioactive decay of 64Cu indicate the plausible timing for imaging. Here, we confirmed that the plausible timing for imaging, using the scanning protocol described in this study, was 48 h after the injection. Compared with an optimal imaging time of 5 d after 89Zr-trastuzumab injection (20), 64Cu-DOTA-trastuzumab seems to be more acceptable in clinical practice. The radiation exposure per injection in a patient receiving 64Cu-DOTA-trastuzumab PET was estimated to be 4.5 mSv, which is much lower than that of 89Zr-trastuzumab PET (18 mSv) (20). These findings confirm the feasibility of this novel PET imaging method even in an outpatient setting based on the shorter half-life of this isotope relative to 111In, 124I, and 89Zn. Thus, there are likely benefits and drawbacks to each of these compounds. Because of its relatively longer half-life, allowing the patient to be imaged at longer time points, 89Zn-trastuzumab provides clearer images; however, it induces higher radiation exposure. On the other hand, the shorter half-life of 64Cu induces lower radiation exposure; however, it provides images with nonspecific activity in the blood. It was difficult to detect lesions around the liver, heart, and blood because of the nonspecific high uptake of the probe within these organs, which is considered a disadvantage of this method. One possible approach to decreasing the nonspecific background is to use 64Cu-DOTA-trastuzumab F(ab′)2 fragments (28). The small, molecule-sized, antibody fragment probe might achieve rapid clearance from the blood resulting in better target detection. We are currently trying to downsize the antibody molecules, but thus far, the affinity of F(ab′)2 fragments has been much less than that of the original full-sized antibody. Another possible approach to decreasing high uptake of the probe by the liver could be to use cold trastuzumab with 64Cu-DOTA-trastuzumab injection. The relatively high uptake by the liver in patients 3 and 6, who had no history of trastuzumab therapy, may suggest the effectiveness of using cold trastuzumab. An adequate interval from predosing of the cold trastuzumab should be determined in a future study. Moreover, the cutoff level must be precisely addressed to discriminate between normal tissues and HER2-positive tumors in larger sample sizes.

An interesting finding of this study was that 64Cu-DOTA-trastuzumab could target brain metastatic lesions. In a clinical setting, it is not possible to obtain a brain tissue sample without surgery; however, knowledge of the HER2 status would in turn allow the identification of the best additional systemic treatment to control the symptoms of the central nervous system. Although penetration of the blood–brain barrier by trastuzumab is generally considered to be poor, we could visualize brain lesions in this study, probably because of disruption of the blood–brain barrier at the site of brain metastasis or whole-brain radiation. PET imaging with 64Cu-DOTA-trastuzumab may have potential to characterize the HER2 status of brain lesions, but further study of both HER2-positive and HER2-negative tumors is necessary.

A potential application of 64Cu-DOTA-trastuzumab PET imaging may lie in its ability to allow for the initial evaluation of the HER2 status of tumors by a means other than biopsy. We successfully detected primary HER2-positive breast tumors in 3 patients using this technique. However, further studies are needed to find the relative sensitivity and specificity of this imaging technique by comparison with conventional immunohistochemistry or FISH testing.

Another potential application of 64Cu-DOTA-trastuzumab PET imaging is in the biologic monitoring of HER2 expression during the course of the disease. Differences in HER2 expression within the same patient across a tumor lesion or at different periods have been reported (8,9). 64Cu-DOTA-trastuzumab PET imaging is associated with a potent quantitative biomarker that can predict the biologic effect of anti-HER2 antibodies. This information might help in the choice between anti-HER2 antibodies (4,12,29) and HER2 tyrosine kinase inhibitors (10,11) for individual HER2 inhibitor therapy.

In addition to these 2 applications in breast cancer patients, 64Cu-DOTA-trastuzumab PET imaging may also be applicable in other kinds of malignancies. Trastuzumab in combination with chemotherapy can be considered a new standard option for patients with HER2-positive advanced gastric cancer (30). Consequently, 64Cu-DOTA-trastuzumab PET imaging in gastric cancer is an expanding area of research.

In this study, the time from biopsy to 64Cu-DOTA-trastuzumab PET imaging ranged from 1 to 22 mo, and most of these individuals received trastuzumab therapy during these periods. HER2 status may change over time and with anti-HER therapy; however, we could not confirm the HER2 status at the time of 64Cu-DOTA-trastuzumab PET imaging. This is a potential weakness of our study, but in general, it is difficult to assess the biologic specificity of HER2 PET in humans because of the need for an additional biopsy after the administration of the probe. In a xenografted model using tumors with 2 different HER2 expression levels, we have confirmed the HER2 specificity of 64Cu-DOTA-trastuzumab PET imaging (Supplemental Fig. 1). To confirm the HER2 specificity of 64Cu-DOTA-trastuzumab PET imaging in humans, further studies are required to compare the results of pathologic studies performed after surgery or core-needle biopsy with the HER2 status obtained on PET.

CONCLUSION

64Cu-labeled molecular target probes may allow rapid evaluation during early screening of leading compounds in preclinical studies and in the development of anticancer drugs. In clinical studies, these probes also have great potential to achieve proof of concept. In combination with pharmacokinetic and pharmacodynamic studies, molecular imaging studies in a clinical trial would provide a more powerful approach to explore appropriate ways of using molecule-targeted drugs.

DISCLOSURE

The costs of publication of this article were defrayed in part by the payment of page charges. Therefore, and solely to indicate this fact, this article is hereby marked “advertisement” in accordance with 18 USC section 1734. This study was supported by a consignment expense for the Japan Advanced Molecular Imaging Program (JAMP) from the Ministry of Education, Culture, Sports, Science and Technology (MEXT), Japanese Government. No other potential conflict of interest relevant to this article was reported.

Acknowledgments

We thank Chinuyo Sumita, Riyo Zochi, Yoko Morimoto, and the staff of the RIKEN Center for Molecular Imaging Science for supplying 64Cu-DOTA-trastuzumab and their technical support. We also thank Nao Nakamura and Rumi Koyama for secretarial support during this study. Finally, we thank all the study participants and patients who provided tissue samples for this analysis.

Footnotes

  • Published online Sep. 12, 2013.

  • © 2013 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

REFERENCES

  1. 1.↵
    1. Buzdar AU,
    2. Ibrahim NK,
    3. Francis D,
    4. et al
    . Significantly higher pathologic complete remission rate after neoadjuvant therapy with trastuzumab, paclitaxel, and epirubicin chemotherapy: results of a randomized trial in human epidermal growth factor receptor 2–positive operable breast cancer. J Clin Oncol. 2005;23:3676–3685.
    OpenUrlAbstract/FREE Full Text
  2. 2.↵
    1. Piccart-Gebhart MJ,
    2. Procter M,
    3. Leyland-Jones B,
    4. et al
    .; Herceptin Adjuvant (HERA) Trial Study Team. Trastuzumab after adjuvant chemotherapy in HER2-positive breast cancer. N Engl J Med. 2005;353:1659–1672.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Romond EH,
    2. Perez EA,
    3. Bryant J,
    4. et al
    . Trastuzumab plus adjuvant chemotherapy for operable HER2-positive breast cancer. N Engl J Med. 2005;353:1673–1684.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Slamon DJ,
    2. Leyland-Jones B,
    3. Shak S,
    4. et al
    . Use of chemotherapy plus a monoclonal antibody against HER2 for metastatic breast cancer that overexpresses HER2. N Engl J Med. 2001;344:783–792.
    OpenUrlCrossRefPubMed
  5. 5.↵
    1. Tripathy D,
    2. Slamon DJ,
    3. Cobleigh M,
    4. et al
    . Safety of treatment of metastatic breast cancer with trastuzumab beyond disease progression. J Clin Oncol. 2004;22:1063–1070.
    OpenUrlAbstract/FREE Full Text
  6. 6.↵
    1. Sauter G,
    2. Lee J,
    3. Bartlett JM,
    4. Slamon DJ,
    5. Press MF
    . Guidelines for human epidermal growth factor receptor 2 testing: biologic and methodologic considerations. J Clin Oncol. 2009;27:1323–1333.
    OpenUrlAbstract/FREE Full Text
  7. 7.↵
    1. Lebeau A,
    2. Turzynski A,
    3. Braun S,
    4. et al
    . Reliability of human epidermal growth factor receptor 2 immunohistochemistry in breast core needle biopsies. J Clin Oncol. 2010;28:3264–3270.
    OpenUrlAbstract/FREE Full Text
  8. 8.↵
    1. Xiao C,
    2. Gong Y,
    3. Han EY,
    4. Gonzalez-Angulo AM,
    5. Sneige N
    . Stability of HER2-positive status in breast carcinoma: a comparison between primary and paired metastatic tumors with regard to the possible impact of intervening trastuzumab treatment. Ann Oncol. 2011;22:1547–1553.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    1. Houssami N,
    2. Macaskill P,
    3. Balleine RL,
    4. Bilous M,
    5. Pegram MD
    . HER2 discordance between primary breast cancer and its paired metastasis: tumor biology or test artifact? Insights through meta-analysis. Breast Cancer Res Treat. 2011;129:659–674.
    OpenUrlCrossRefPubMed
  10. 10.↵
    1. Geyer CE,
    2. Forster J,
    3. Lindquist D,
    4. et al
    . Lapatinib plus capecitabine for HER2-positive advanced breast cancer. N Engl J Med. 2006;355:2733–2743.
    OpenUrlCrossRefPubMed
  11. 11.↵
    1. Blackwell KL,
    2. Burstein HJ,
    3. Storniolo AM,
    4. et al
    . Randomized study of Lapatinib alone or in combination with trastuzumab in women with ErbB2-positive, trastuzumab-refractory metastatic breast cancer. J Clin Oncol. 2010;28:1124–1130.
    OpenUrlAbstract/FREE Full Text
  12. 12.↵
    1. Baselga J,
    2. Cortés J,
    3. Kim SB,
    4. et al
    .; CLEOPATRA Study Group. Pertuzumab plus trastuzumab plus docetaxel for metastatic breast cancer. N Engl J Med. 2012;366:109–119.
    OpenUrlCrossRefPubMed
  13. 13.↵
    1. Verma S,
    2. Miles D,
    3. Gianni L,
    4. et al
    .; EMILIA Study Group. Trastuzumab emtansine for HER2-positive advanced breast cancer. N Engl J Med. 2012;367:1783–1791.
    OpenUrlCrossRefPubMed
  14. 14.↵
    1. de Korte MA,
    2. de Vries EG,
    3. Lub-de Hooge MN,
    4. et al
    . 111Indium-trastuzumab visualises myocardial human epidermal growth factor receptor 2 expression shortly after anthracycline treatment but not during heart failure: a clue to uncover the mechanisms of trastuzumab-related cardiotoxicity. Eur J Cancer. 2007;43:2046–2051.
    OpenUrlCrossRefPubMed
  15. 15.↵
    1. Perik PJ,
    2. Lub-De Hooge MN,
    3. Gietema JA,
    4. et al
    . Indium-111-labeled trastuzumab scintigraphy in patients with human epidermal growth factor receptor 2-positive metastatic breast cancer. J Clin Oncol. 2006;24:2276–2282.
    OpenUrlAbstract/FREE Full Text
  16. 16.↵
    1. Robinson MK,
    2. Doss M,
    3. Shaller C,
    4. et al
    . Quantitative immuno-positron emission tomography imaging of HER2-positive tumor xenografts with an iodine-124 labeled anti-HER2 diabody. Cancer Res. 2005;65:1471–1478.
    OpenUrlAbstract/FREE Full Text
  17. 17.
    1. Reddy S,
    2. Shaller CC,
    3. Doss M,
    4. et al
    . Evaluation of anti-HER2 C6.5 diabody as a PET radiotracer to monitor HER2 status and predict response to trastuzumab treatment. Clin Cancer Res. 2011;17:1509–1520.
    OpenUrlAbstract/FREE Full Text
  18. 18.↵
    1. Oude Munnink TH,
    2. Korte MA,
    3. Nagengast WB,
    4. et al
    . 89Zr-trastuzumab PET visualises HER2 down regulation by the HSP90 inhibitor NVP-AUY922 in a human tumor xenograft. Eur J Cancer. 2010;46:678–684.
    OpenUrlCrossRefPubMed
  19. 19.↵
    1. Börjesson PK,
    2. Jauw YW,
    3. Boellaard R,
    4. et al
    . Performance of immuno–positron emission tomography with zirconium-89-labeled chimeric monoclonal antibody U36 in the detection of lymph node metastases in head and neck cancer patients. Clin Cancer Res. 2006;12:2133–2140.
    OpenUrlAbstract/FREE Full Text
  20. 20.↵
    1. Dijkers EC,
    2. Oude Munnink TH,
    3. Kosterink JG,
    4. et al
    . Biodistribution of 89Zr-trastuzumab and PET imaging of HER2-positive lesions in patients with metastatic breast cancer. Clin Pharmacol Ther. 2010;87:586–592.
    OpenUrlCrossRefPubMed
  21. 21.
    1. Kurdziel K,
    2. Mena E,
    3. Adler S,
    4. et al
    . Human dosimetry and tumor kinetics of 111In CHX-A” DTPA trastuzumab in solid tumors using gamma-camera imaging [abstract]. J Nucl Med. 2011;52(suppl 1):308P.
    OpenUrl
  22. 22.↵
    1. Jayson GC,
    2. Zweit J,
    3. Jackson A,
    4. et al
    . Molecular imaging and biological evaluation of HuMV833 anti-VEGF antibody: implications for trial design of antiangiogenetic antibodies. J Natl Cancer Inst. 2002;94:1484–1493.
    OpenUrlAbstract/FREE Full Text
  23. 23.↵
    1. Li ZB,
    2. Niu G,
    3. Wang H,
    4. et al
    . Imaging of urokinase-type plasminogen activator receptor expression using a 64Cu-labeled linear peptide antagonist by microPET. Clin Cancer Res. 2008;14:4758–4766.
    OpenUrlAbstract/FREE Full Text
  24. 24.↵
    1. Obata A,
    2. Kasamatsu S,
    3. McCarthy DW,
    4. et al
    . Production of therapeutic quantities of 64Cu using a 12 MeV cyclotron. Nucl Med Biol. 2003;30:535–539.
    OpenUrlCrossRefPubMed
  25. 25.↵
    1. Iijima M,
    2. Kadoya H,
    3. Hatahira S,
    4. et al
    . Nanocapsules incorporating IgG Fc-binding domain derived from Staphylococcus aureus protein-A for displaying IgGs on immunosensor chips. Biomaterials. 2011;32:1455–1464.
    OpenUrlCrossRefPubMed
  26. 26.↵
    1. Stabin MG,
    2. Sparks RB,
    3. Crowe E
    . OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023–1027.
    OpenUrlAbstract/FREE Full Text
  27. 27.↵
    1. Delbeke D,
    2. Coleman RE,
    3. Guiberteau MJ,
    4. et al
    . Procedure guideline for tumor imaging with 18F-FDG PET/CT 1.0. J Nucl Med. 2006;47:885–895.
    OpenUrlFREE Full Text
  28. 28.↵
    1. Leung K
    . 64Cu-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid-epidermal growth factor receptor-binding fibronectin domain E13.4.3′. Molecular Imaging and Contrast Agent Database (MICAD). http://www.ncbi.nlm.nih.gov/books/NBK99555/. Published May 3, 2013. Updated August 9, 2013. Accessed August 29, 2013.
  29. 29.↵
    1. LoRusso PM,
    2. Weiss D,
    3. Guardino E,
    4. Girish S,
    5. Sliwkowski MX
    . Trastuzumab emtansine: a unique antibody-drug conjugate in development for human epidermal growth factor receptor 2-positive cancer. Clin Cancer Res. 2011;17:6437–6447.
    OpenUrlAbstract/FREE Full Text
  30. 30.↵
    1. Bang YJ,
    2. Van Cutsem E,
    3. Feyereislova A,
    4. et al
    . Trastuzumab in combination with chemotherapy versus chemotherapy alone for treatment of HER2-positive advanced gastric or gastro-oesophageal junction cancer (ToGA): a phase 3, open-label, randomised controlled trial. Lancet. 2010;376:687–697.
    OpenUrlCrossRefPubMed
  • Received for publication December 14, 2012.
  • Accepted for publication May 9, 2013.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 54 (11)
Journal of Nuclear Medicine
Vol. 54, Issue 11
November 1, 2013
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
64Cu-DOTA-Trastuzumab PET Imaging in Patients with HER2-Positive Breast Cancer
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
64Cu-DOTA-Trastuzumab PET Imaging in Patients with HER2-Positive Breast Cancer
Kenji Tamura, Hiroaki Kurihara, Kan Yonemori, Hitoshi Tsuda, Junko Suzuki, Yuzuru Kono, Natsuki Honda, Makoto Kodaira, Harukaze Yamamoto, Mayu Yunokawa, Chikako Shimizu, Koki Hasegawa, Yousuke Kanayama, Satoshi Nozaki, Takayuki Kinoshita, Yasuhiro Wada, Shusaku Tazawa, Kazuhiro Takahashi, Yasuyoshi Watanabe, Yasuhiro Fujiwara
Journal of Nuclear Medicine Nov 2013, 54 (11) 1869-1875; DOI: 10.2967/jnumed.112.118612

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
64Cu-DOTA-Trastuzumab PET Imaging in Patients with HER2-Positive Breast Cancer
Kenji Tamura, Hiroaki Kurihara, Kan Yonemori, Hitoshi Tsuda, Junko Suzuki, Yuzuru Kono, Natsuki Honda, Makoto Kodaira, Harukaze Yamamoto, Mayu Yunokawa, Chikako Shimizu, Koki Hasegawa, Yousuke Kanayama, Satoshi Nozaki, Takayuki Kinoshita, Yasuhiro Wada, Shusaku Tazawa, Kazuhiro Takahashi, Yasuyoshi Watanabe, Yasuhiro Fujiwara
Journal of Nuclear Medicine Nov 2013, 54 (11) 1869-1875; DOI: 10.2967/jnumed.112.118612
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Towards integration of 64Cu-DOTA-Trasztusumab PET-CT and MRI with mathematical modeling to predict response to neoadjuvant therapy in HER2+ breast cancer
  • Development of 64Cu-NOTA-Trastuzumab for HER2 Targeting: A Radiopharmaceutical with Improved Pharmacokinetics for Human Studies
  • Emerging Gene Fusion Drivers in Primary and Metastatic Central Nervous System Malignancies: A Review of Available Evidence for Systemic Targeted Therapies
  • Drug Resistance in HER2-Positive Breast Cancer Brain Metastases: Blame the Barrier or the Brain?
  • Preclinical and clinical applications of specific molecular imaging for HER2-positive breast cancer
  • 64Cu-MM-302 Positron Emission Tomography Quantifies Variability of Enhanced Permeability and Retention of Nanoparticles in Relation to Treatment Response in Patients with Metastatic Breast Cancer
  • The brain microenvironment mediates resistance in luminal breast cancer to PI3K inhibition through HER3 activation
  • Immuno-PET Using Anticarcinoembryonic Antigen Bispecific Antibody and 68Ga-Labeled Peptide in Metastatic Medullary Thyroid Carcinoma: Clinical Optimization of the Pretargeting Parameters in a First-in-Human Trial
  • Targeting the Human Epidermal Growth Factor Receptors with Immuno-PET: Imaging Biomarkers from Bench to Bedside
  • ImmunoPET/MR imaging allows specific detection of Aspergillus fumigatus lung infection in vivo
  • Imaging Diagnostic and Therapeutic Targets: Human Epidermal Growth Factor Receptor 2
  • Molecular Imaging Reveals Trastuzumab-Induced Epidermal Growth Factor Receptor Downregulation In Vivo
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles

Keywords

  • HER2-positive breast cancer
  • trastuzumab
  • PET
  • 64Cu
  • Molecular imaging
SNMMI

© 2025 SNMMI

Powered by HighWire