Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleClinical Investigations

Complementary Roles of 18F-DOPA PET/CT and 18F-FDG PET/CT in Medullary Thyroid Cancer

Saila Kauhanen, Camilla Schalin-Jäntti, Marko Seppänen, Sami Kajander, Sami Virtanen, Jukka Schildt, Irina Lisinen, Aapo Ahonen, Ilkka Heiskanen, Mika Väisänen, Johanna Arola, Pirkko Korsoff, Tapani Ebeling, Timo Sane, Heikki Minn, Matti J. Välimäki and Pirjo Nuutila
Journal of Nuclear Medicine December 2011, 52 (12) 1855-1863; DOI: https://doi.org/10.2967/jnumed.111.094771
Saila Kauhanen
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Camilla Schalin-Jäntti
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Marko Seppänen
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sami Kajander
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sami Virtanen
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jukka Schildt
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Irina Lisinen
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Aapo Ahonen
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ilkka Heiskanen
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mika Väisänen
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Johanna Arola
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pirkko Korsoff
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tapani Ebeling
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Timo Sane
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Heikki Minn
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Matti J. Välimäki
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pirjo Nuutila
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Abstract

Serum calcitonin and carcinoembryonic antigen (CEA) are markers of recurrent or persistent disease in medullary thyroid cancer (MTC). However, conventional imaging often fails to localize metastatic disease. Our aim was to compare fluorine-labeled dihydroxyphenylalanine (18F-DOPA) and 18F-FDG PET/CT with multidetector CT (MDCT) and MRI in recurrent or persistent MTC. Methods: Nineteen MTC patients with increased calcitonin or CEA on follow-up (mean ± SD, 93 ± 91 mo; range, 4–300 mo) after primary therapy were prospectively imaged with 4 techniques: 18F-DOPA PET/CT, 18F-FDG PET/CT, MDCT, and MRI. Images were analyzed for pathologic lesions, which were surgically removed when possible. The correlation between the detection rate for each method and the calcitonin and CEA concentrations and histopathologic findings was investigated. Results: On the basis of histology and follow-up, one or more imaging methods accurately localized metastatic disease in 12 (63%) of 19 patients. The corresponding figures for 18F-DOPA PET/CT, 18F-FDG PET/CT, MDCT, and MRI were 11 (58%) of 19, 10 (53%) of 19, 9 (47%) of 19, and 10 (59%) of 17, respectively. Calcitonin and CEA correlated with 18F-DOPA PET/CT (P = 0.0007 and P = 0.0263, respectively) and 18F-FDG PET/CT findings (both P < 0.0001). In patients with an unstable calcitonin doubling time (n = 8), 18F-DOPA and 18F-FDG PET/CT were equally sensitive. In contrast, for patients with an unstable CEA doubling time (n = 4), 18F-FDG PET/CT was more accurate. Conclusion: For most MTC patients with occult disease, 18F-DOPA PET/CT accurately detects metastases. In patients with an unstable calcitonin level, 18F-DOPA PET/CT and 18F-FDG PET/CT are complementary. For patients with an unstable CEA doubling time, 18F-FDG PET/CT may be more feasible. MRI is sensitive but has the highest rate of false-positive results.

  • 18-fluorodeoxyglucose
  • 18-fluorodehydroxyphenylalanine
  • medullary thyroid cancer

Medullary thyroid cancer (MTC) is a rare malignancy arising from the parafollicular thyroid C cells (1). Surgery is the only possible curative therapy. Prognostic factors include postoperative tumor burden and serum calcitonin concentration (2). Recently, promising results with systemic therapy including multikinase inhibitors (3) and pretargeted radioimmunotherapy have been reported (4). The primary treatment is total thyroidectomy, often including modified neck lymph node dissection. Follow-up is based on the tumor markers calcitonin and carcinoembryonic antigen (CEA) and neck ultrasonography (5). Persistent or increasing serum calcitonin and CEA levels imply residual or recurrent disease, but conventional imaging frequently remains negative. Calcitonin is the most sensitive marker and typically increases long before neck ultrasonography or CT demonstrates pathologic lymph nodes or distant metastases (6). Early and precise localization of residual or recurrent disease plays a mainstay role in planning the subsequent therapy. This would include surgery of locoregional metastatic disease or, for patients with distant metastatic spread, one of the new systemic treatment modalities and possibly palliative debulking surgery.

Diagnostic imaging of recurrent or residual MTC is difficult, and current conventional imaging techniques lack sensitivity. However, there have been encouraging results with PET using various tracers, and integrated PET/CT has improved the diagnostic accuracy. 18F-FDG is widely used in oncologic imaging; dihydroxyphenylalanine (18F-DOPA) PET represents a new imaging tool in MTC (7–10).

The aim of the present study was to evaluate which imaging technique is best suited for the detection of metastatic MTC and whether the suitability is influenced by calcitonin and CEA concentrations. We prospectively compared the results of conventional imaging methods (multidetector CT [MDCT] and MRI) with those of PET/CT using 18F-FDG and 18F-DOPA in a series of MTC patients with recurrent or persistent disease, as evidenced by increased calcitonin or CEA concentrations on follow-up. The lesions detected were surgically removed when possible. To rule out false-positive imaging results, imaging results were compared with histologic results. Furthermore, we compared the tumor proliferation marker Ki-67 index (%) of all primary tumors with that of the metastases removed. The effect of surgery on marker concentrations was also evaluated.

MATERIALS AND METHODS

Patients and Study Design

This was a prospective, controlled multicenter trial including patients with residual or recurrent MTC after primary surgery. Between August 2007 and October 2009, 19 consecutive patients (10 men and 9 women; age range, 31–74 y; mean age, 51.6 y) with histologically proven MTC and increased calcitonin or CEA tumor markers were prospectively imaged using 18F-DOPA PET/CT, 18F-FDG PET/CT, MDCT, and MRI. All patients had undergone total thyroidectomy as the initial therapy. Patient characteristics are given in Supplemental Table 1 (supplemental materials are available online only at http://jnm.snmjournals.org). Patients 4, 8, and 17 had familial MTC (multiple endocrine neoplasia, type 2). Two patients could not undergo MRI because of a metallic foreign body or claustrophobia. All imaging methods were conducted within 6 wk. Twelve patients underwent surgery or had histopathologic confirmation of disease, 6 patients were followed up (range, 9–37 mo after imaging studies; mean ± SD, 15.7 ± 10.9 mo), and 1 patient died after 3 mo of follow-up because of progressive aggressive MTC; autopsy was not done. The study was conducted according to the guidelines of the Declaration of Helsinki, and the study protocol was approved by the ethics committee of the Hospital District of Southwest Finland. All patients gave written informed consent before participating in the study.

18F-FDG PET/CT Protocol

18F-FDG PET/CT was done using a Discovery PET/CT STE scanner (GE Healthcare) at Turku PET Centre (n = 10) or a Gemini GXL PET/CT scanner (Philips) at Helsinki PET Centre (n = 9). The patients fasted for 6 h before the study. The dose of intravenous 18F-FDG was 377 ± 30 MBq. Approximately 60 min after injection, a static 18F-FDG PET/CT scan in 3 dimensions covering the upper torso from eyebrows to mid thighs (3-min emission scan per position) started. Attenuation correction was performed using a low-dose ultrafast CT protocol (80 mAs, 140 kV, 0.3 mSv per field of view). Transaxial, coronal, and sagittal images for visual and semiquantitative analysis of the data were corrected for dead time, decay, and photon attenuation and reconstructed in a 128 × 128 matrix. Images were reconstructed using 2 iterations and 28 subsets with a postprocessing filter of 6.0 mm in full width at half maximum and fully 3-dimensional maximum-likelihood ordered-subset expectation maximization. Any focal tracer accumulation exceeding normal regional tracer uptake was considered pathologic. PET images were analyzed visually and semiquantitatively by calculating mean and maximum standardized uptake value (SUVmax), defined as the ratio of activity per milliliter of tissue to the activity in the injected dose corrected by decay and by the patient's body weight. A 1-cm-diameter (0.77 cm3) region of interest was placed on the area of the lesion with the highest uptake.

18F-DOPA PET/CT Protocol

All 18F-DOPA PET/CT studies were performed at Turku PET Centre. The patients fasted for at least 6 h before undergoing PET/CT. If the patient was taking medication that could affect the biodistribution of 18F-DOPA (diazoxide or cortisone), this medication was withdrawn 24 h before the study. All 18F-DOPA PET/CT scans were acquired using the Discovery PET/CT STE scanner. 18F-DOPA was synthesized as previously described (11). The average administered dose of 18F-DOPA was 243 ± 46 MBq. The decarboxylase inhibitor, carbidopa, was given as premedication. Scanning began approximately 60 min after tracer injection. Patients underwent a whole combined PET/CT scan from the level of the eyes to the mid thigh. This CT-based scan was used for attenuation correction and to help in anatomic localization of 18F-DOPA uptake. Immediately after the CT, an emission PET scan was acquired in the 3-dimensional mode over the same anatomic regions, starting at the level of the mid thigh. To obtain images for visual and semiquantitative analysis, we corrected the data for dead time, decay, and photon attenuation and reconstructed the data in a 128 × 128 matrix. The images were reconstructed and analyzed as described for the 18F-FDG PET/CT protocol.

MDCT Protocol

MDCT images were acquired at 5 centers using 7 different CT scanners. The number of detector rows for the scanners ranged from 6 to 64. The final reconstructed axial slice thickness ranged from 2.5 to 6.5 mm. All patients received iodinated contrast medium. In 5 patients, an unenhanced study of the upper abdomen was performed first, followed by contrast administration and imaging in the arterial and venous phases. Seven patients were imaged after contrast administration only in the arterial and venous phases, and 2 patients were imaged in arterial, venous, and 5-min delayed phases. Five patients were imaged in the venous phase only.

MRI Protocol

MRI of the neck and thorax was performed using a 1.5-T system (Gyroscan Intera Nova Dual; Philips Medical Systems) with a head–neck coil. First, T1-weighted transaxial and coronal turbo spin-echo images were obtained. In addition, we acquired T1-weighted spectral fat-saturated inversion recovery transaxial images. After injection of gadolinium (0.2 mL/kg of patient weight; Dotarem [Guerbet]), spectral fat-saturated inversion recovery T1-weighted turbo spin-echo images were acquired in all (transaxial, sagittal, and coronal) dimensions. A 25-cm field of view was used. The slice thickness was 4 mm in all acquisitions. Thereafter, 7-mm T1- and T2-weighted transaxial turbo spin-echo images of the mediastinum and thorax were obtained.

Data Evaluation

18F-DOPA– and 18F-FDG–avid lesions were recorded per patient and per region in 5 distinct regions: neck, mediastinum, lungs, liver, and skeleton. Lymph nodes larger than 10 mm in the smallest diameter were diagnosed as malignant on MRI and MDCT. In addition, the tissues taken during primary surgery and during reoperations were prepared for immunohistochemical examination (cell cycle–associated Ki-67 antigen) and were reanalyzed by an experienced pathologist.

The diagnostic accuracy of the imaging studies was assessed by comparison of histopathologic reports on lesions removed (n = 12) with imaging findings. When histologic reports were not available, a consensus based on the sum of the imaging procedures and data from follow-up examinations was reached (n = 7). Lesion site and axis were taken from pathologic reports if the patient had undergone surgery; otherwise, lesion site and axis were taken from imaging studies. All regions and lesions seen on different imaging modalities were calculated. If more than 10 lesions were present, the number of lesions was truncated at 10 to avoid bias toward that region. Each type of imaging study (18F-DOPA PET/CT, 18F-FDG PET/CT, MDCT, and MRI) was interpreted in a masked manner by a different observer.

Statistical Analysis

The results are expressed mainly as mean values ± SD of the mean. The sensitivity of 18F-FDG PET/CT, 18F-DOPA PET/CT, MDCT, and MRI for lesion detection was calculated using the pathologic results and clinical follow-up as a gold standard, with a 2 × 2 contingency table. A McNemar test was performed to compare 18F-FDG PET/CT, 18F-DOPA PET/CT, MDCT, and MRI results. The κ-coefficient was determined to quantify agreement between these imaging methods and calcitonin and CEA doubling time. Doubling times were determined according to the calculator provided by the American Thyroid Association (http://www.thyroid.org/professionals/calculators/CDTC.php). The Wilcoxon signed-rank test was used to evaluate the number of regions and lesions diagnosed. For the receiver operating characteristics, analysis of sensitivities for different cutoff points of calcitonin and CEA were calculated. A P value of less than 0.05 was considered statistically significant. All statistical analyses were performed with SAS software (version 9.2; SAS Institute Inc.).

RESULTS

Relation of Histologic Data and Clinical Follow-up to Imaging Findings

All study patients had biochemically proven residual or recurrent disease and were therefore suspected of having metastases. Fifteen patients showed pathologic findings on study imaging, 11 of whom subsequently underwent surgery. Eight of these patients were histologically confirmed to have metastatic MTC, and 3 had a benign histologic type (Fig. 1, Table 1). In addition, 1 patient (patient 17) had disseminated disease and underwent surgery because of pheochromocytoma, but no histologic data were available from the metastases. In 3 of 15 imaging-positive patients, no histologic data were available, but disseminated disease was obvious on imaging (Fig. 1). Two of these patients (patients 9 and 10) died after 9 and 3 mo, respectively, of follow-up, and autopsies were not performed. One patient (patient 14) received symptomatic treatment because surgery was considered impossible. In the remaining 4 patients (patients 1, 12, 15, and 16), all 4 imaging techniques were negative. Also these patients were suspected of having residual disease because of an increased calcitonin level (range, 13.8–69.4 pmol/L; normal, <1.7 pmol/L [women] and <3.8 pmol/L [men]), an increased CEA level (range, 2.0–7.3 μg/L; normal, <3.5 μg/L), or both. In one of these patients (patient 1), metastatic MTC was confirmed on follow-up 37 mo later with MDCT.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Patient flow chart.

View this table:
  • View inline
  • View popup
TABLE 1

Comparison of Different Imaging Methods, Calcitonin and CEA Doubling Time, and Ki-67 Expression

Patient-by-Patient Analysis

In patient-based analysis, metastatic lesions were shown in 11 of 19 patients on 18F-DOPA PET/CT and in 10 of 19 patients on 18F-FDG PET/CT. Normal imaging results in these patients were classified as false-negative. The diagnostic per-patient detection rates were 58% (95% confidence interval [CI], 35.7%–80.1%) for 18F-DOPA PET/CT, 53% (95% CI, 30.2%–75.1%) for 18F-FDG PET/CT, 47% (95% CI, 30.2%–75.1%) for MDCT, and 59% (95% CI, 35.4%–82.2%) for MRI. Because of the small sample size, the McNemar test did not show any method to have any significant additional value for diagnosis of metastatic MTC. The detection rate of multimodality imaging was 74% (95% CI, 53.9%–93.5%) for both 18F-DOPA and 18F-FDG PET/CT and 68% (95% CI, 47.5%–89.3%) for conventional imaging (MDCT and MRI) (P = 0.5637).

Region-by-Region and Lesion-by-Lesion Analysis

The total number of lesions detected in 5 regions (neck, lungs, mediastinum, liver, and bone) is shown in Supplemental Table 2.

In region-based analysis, 26 (27%) of 95 regions evaluated were considered metastatic on the basis of the reference standard (histology [n = 11] or a lesion demonstrated by at least 2 imaging methods [n = 12]). In 4 regions, only 1 method revealed a metastasis: patients 6 and 19 had lesions in the mediastinum on MRI, patient 9 had lesions in the neck on 18F-DOPA PET/CT, and patient 18 had a lesion in the lungs on MRI. In these patients, metastases had been detected also in other regions.

In lesion-based analysis, 118 lesions were considered metastatic on the basis of the reference standard. 18F-DOPA PET/CT detected 61 (52%) of 118 lesions; 18F-FDG PET/CT, 55 lesions (47%); MDCT, 54 lesions (46%); and MRI, 92 lesions (78%). Compared with other imaging methods, MRI detected most lesions for each region analyzed (neck, lung, liver, and bone) except for the mediastinum (16 by MRI vs. 24 by 18F-DOPA PET/CT). On the basis of the reference standard, a total of 7 lesions were considered false-positive: 6 on MRI, 2 on 18F-FDG PET/CT, and 1 each on 18F-DOPA PET/CT and MDCT. The mean SUVmax of all lesions was 3.57 ± 4.59 for 18F-DOPA PET/CT and 2.55 ± 2.87 for 18F-FDG PET/CT.

Tumor Markers and Histopathology and Correlation with Imaging Findings

Calcitonin and CEA

Calcitonin and CEA concentrations at the time of imaging are given in Supplemental Table 1. Calcitonin was higher in patients with positive imaging findings and was only marginally increased in those with false-negative findings (Wilcoxon correlation coefficient, P = 0.0015). The best discriminative value for detecting metastasis with any of the imaging methods was a cutoff of 54.0 pmol/L (normal value, <3.8 pmol/L for men and <1.7 pmol/L for women) for calcitonin in receiver-operating characteristic analysis. When calculated for each different imaging method separately, the cutoff was 44.8 pmol/L for 18F-DOPA PET/CT, 56.8 pmol/L for 18F-FDG PET/CT, 72.0 pmol/L for MDCT, and 62.9 pmol/L for MRI. Both calcitonin and CEA correlated with the number of lesions diagnosed on 18F-DOPA PET/CT (P = 0.0007 and 0.0263, respectively, Fig. 2A). Lesions detected with 18F-FDG PET/CT correlated strongly with both calcitonin and CEA (P < 0.0001) (Fig. 2B). This correlation was observed also with MDCT and MRI. In addition, calcitonin and CEA correlated significantly with 18F-FDG PET/CT SUVmax (the highest SUVmax of all lesions was considered) (P < 0.0001 and P = 0.0006, respectively). The same trend was observed between calcitonin (P = 0.0158) or CEA (P = 0.0553) level and SUVmax of 18F-DOPA PET/CT.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

(A) Calcitonin and CEA correlation for number of lesions detected on 18F-DOPA PET/CT. (B) Calcitonin and CEA correlation for number of lesions detected on 18F-FDG PET/CT.

Tumor markers decreased postoperatively in 4 of 8 operated patients with histologic verification of metastasis (patients 2, 3, 7, and 11). In these patients, only 1 metastasis was detected and then radically operated on. In 3 patients (patients 6, 18, and 19), tumor markers remained unchanged; of these, patients 6 and 18 underwent debulking surgery. In 1 patient (patient 4), tumor markers continued to increase after debulking surgery (Table 1).

Calcitonin and CEA Doubling Time

Tumor marker doubling time (mo) and imaging results are presented in Table 1. Calcitonin and CEA doubling time was inversely related to the number of lesions diagnosed on 18F-FDG PET/CT; these correlations were borderline-significant (P = 0.0798 and 0.0546, respectively) (Fig. 3A). Calcitonin and CEA doubling time (mo) did not correlate with the number of lesions detected on 18F-DOPA PET/CT (P = 0.2142 and 0.2393, respectively) (Fig. 3B). Eighty percent of patients with a calcitonin doubling time of less than 24 mo (denoting unstable disease, n = 8) had a positive finding on at least 1 imaging technique; the corresponding figure for patients with a calcitonin doubling time of more than 24 mo (denoting stable disease, n = 11) was 44%. The κ-coefficient for agreement was positive for unstable or stable calcitonin level and CEA doubling time and detection or no detection of recurrent disease (κ = 0.36 and 0.28, respectively). The total number of lesions detected using the different imaging methods is shown in Figure 4. For a calcitonin doubling time of less than 24 mo, metastases were detected in 70% of patients with both 18F-DOPA and 18F-FDG PET/CT. In contrast, for a CEA doubling time of less than 24 mo, 18F-FDG PET/CT correctly detected metastases in 80% of patients and 18F-DOPA PET/CT in 60%.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

(A) CEA and calcitonin doubling time (mo) for number of lesions detected on 18F-FDG PET/CT. (B) CEA and calcitonin doubling time (mo) for number of lesions detected on 18F-DOPA PET/CT. Ct = calcitonin.

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

Total number of lesions detected using different imaging techniques in stable (0) and unstable (1) tumor marker groups. Ct = calcitonin.

Histopathology

Histopathologic data were reanalyzed by an experienced pathologist without knowledge of imaging findings. The Ki-67 proliferation index was determined for all primary tumors and for lesions removed that proved to be metastases (n = 9) (Table 1). In 6 of 9 patients, Ki-67 was higher in the metastases than in the primary tumor. Two patients with primary tumor proliferation indices of 30% and 60% (patients 10 and 18, Table 1) had aggressive disease and died a few months after diagnosis.

Figure 5 demonstrates a patient (patient 11) with a calcitonin level of 44.8 pmol/L in whom a neck metastasis with a low proliferation index of 5% was detected on 18F-DOPA PET/CT, whereas 18F-FDG PET/CT, MDCT, and MRI remained negative. Figure 6 demonstrates a patient with aggressive disease.

FIGURE 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 5.

61-y-old woman (patient 11) with occult MTC and calcitonin level of 44.8 pmol/L 9 y after primary therapy. Imaging with MDCT (A) and MRI (B) was negative. 18F-DOPA PET/CT (C) demonstrated increased uptake of 18F-DOPA in neck. 18F-FDG PET/CT (D) was negative. Lesion was surgically removed; histology was compatible with lymph node metastasis, and Ki-67 was 5% (E).

FIGURE 6.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 6.

56-y-old man (patient 10) with aggressive MTC and high primary tumor Ki-67 of 30%. Two years after primary treatment, calcitonin level was 1,598 pmol/L and CEA 460 μg/L, with unstable calcitonin and CEA doubling time (10 mo). 18F-FDG PET/CT demonstrated disseminated disease (A, several lesions in liver, skeleton, neck, and paraaortal region), but 18F-DOPA PET/CT was negative (B). MDCT (C) and MRI (D) showed lesions in liver, skeleton, and neck. Patient died 3 mo after imaging.

DISCUSSION

To our knowledge, this was the first prospective study comparing combined 18F-DOPA and 18F-FDG PET/CT with conventional MDCT and MRI in MTC patients with increased calcitonin and CEA concentrations. The detected lesions were surgically removed when possible and examined histopathologically. Our study showed that metastatic disease was accurately localized in 12 (63%) of 19 patients on combined imaging, in 11 (56%) of 19 on 18F-DOPA PET/CT, in 10 (53%) of 19 on 18F-FDG PET/CT, and in 9 (47%) of 19 on MDCT. MRI was performed on 17 patients and detected most lesions but had the highest rate of false-positive results. Importantly, in a patient with a calcitonin level of only 44.8 pmol/L, 18F-DOPA PET/CT was the only imaging method that accurately localized a metastasis with a Ki-67 of 5% in the neck. 18F-DOPA PET/CT may be of particular value for detection of occult metastatic MTC characterized by a low proliferation index. In MTC patients with increasing calcitonin levels during follow-up, 18F-DOPA PET/CT and 18F-FDG PET/CT have complementary roles. Although the number of patients with an unstable CEA doubling time (<24 mo) was small (n = 4), our data support the notion that imaging with 18F-FDG PET/CT rather than 18F-DOPA PET/CT is better for such patients, as indicated by the higher detection rate for metastatic disease. Bogsrud et al. (12) evaluated the prognostic value of 18F-FDG PET and found that calcitonin doubling time was shorter for PET-positive than -negative patients. Our finding is in concordance with that study. It is clear that the results are affected by the subtypes of MTC included in the different studies, which may vary from occult disease that remains stable over 10–20 y to aggressive disease that shortens the life span.

Several studies have shown that 18F-FDG PET has better sensitivity than conventional imaging in MTC (13–18). In line with the present study, 18F-FDG uptake in MTC correlates with poor differentiation and limited tracer uptake (19,20). There is therefore a need for PET tracers other than 18F-FDG. MTC comprises neuroendocrine tumors capable of taking up and decarboxylating amine precursors. As demonstrated by Ahlström et al. in 1995 with 11C-labeled DOPA (21), 18F-DOPA has been used in the diagnosis of carcinoids (22–24), pheochromocytomas (25,26), glomus tumors (27), and pancreatic neuroendocrine tumors (28). Only a few studies have evaluated the value of 18F-DOPA PET in MTC (7,8,29) and even fewer have used integrated 18F-DOPA-PET/CT (9,30,31).

A preliminary study on 18F-DOPA PET in MTC reported a total of 27 tumors in 11 patients using 18F-DOPA PET (7). The sensitivity was 63% for 18F-DOPA PET, 44% for 18F-FDG, 52% for SRS, and 81% for morphologic imaging. Although morphologic imaging procedures had the best sensitivity, the specificity for primary tumors or local recurrence and lymph node metastases was low (55%–57%). Our study confirmed these results: MRI had the highest detection rate (78%) in lesion-based analysis, but 6 of 7 false-positive results were obtained by MRI. A retrospective study on combined 18F-DOPA PET/CT showed that 18F-DOPA PET/CT had the highest sensitivity (74%), compared with other methods (i.e., PET alone [52%] or CT [68%]) (9).

Approximately 40% of MTC patients have persistent disease as indicated by increased calcitonin concentrations after primary surgery, and 10% with undetectable postoperative calcitonin still have occult disease and develop recurrence later (1). We demonstrated a strong correlation between metastatic lesions and calcitonin concentration, with a calcitonin cutoff of 157 pg/mL (44.8 pmol/L) for 18F-DOPA PET/CT in receiver-operating-characteristic analysis. Furthermore, 18F-DOPA PET/CT was able to detect lesions at lower calcitonin concentrations than the other methods, in line with Luster et al. (9), who reported a sensitivity of 100% for a calcitonin level higher than 150 pg/mL. These findings differ from Koopmans et al. (8), who found 75% negative scans in patients with calcitonin concentrations of less than 500 pg/mL, and from that of Hoergerle et al. (7), who found no MTC-positive 18F-DOPA PET scans if the calcitonin level was less than 550 pg/mL. Further, Marzola et al. found higher calcitonin concentrations in PET-positive than -negative patients but did not notice any difference between the tracers used (18F-FDG or 18F-DOPA) (31). The American Thyroid Association recently recommended additional imaging in MTC in patients with a postsurgical calcitonin level of 150 pg/mL or greater (32), and our results are in line with this result.

A strength of the present study was that it showed improvement of anatomic localization using combined PET/CT. To the best of our knowledge, this was the first study in which PET/CT using 2 different tracers was compared with both dedicated MDCT and MRI. Furthermore, we used carbidopa medication before 18F-DOPA PET/CT. Several groups have suggested that inhibiting the peripheral decarboxylation enhances tumor accumulation of DOPA and 5-hydroxy-l-tryptophan (26,33,34). In previous studies on MTC and 18F-DOPA PET, only the groups of Beuthien-Baumann and Koopmans (8,29) used carbidopa premedication. Furthermore, we assumed that all study patients had at least microscopic disease as evidenced by increased tumor marker concentrations, and we concluded that none of the patients should have true negative imaging.

The major limitation of the present study was the relatively small number of patients, as the disease is rare. Although sample size limits the analysis, our study was unique because it included a population imaged prospectively with 4 different methods. However, the MDCT protocol was not performed on all patients and varied between different institutions.

CONCLUSION

To the best of our knowledge, no previous studies have prospectively compared 18F-DOPA and 18F-FDG PET/CT with both MDCT and MRI. On the basis of our results, 18F-DOPA and 18F-FDG PET/CT are useful complementary imaging tools for accurate identification of metastases both in MTC patients with occult disease and in MTC patients with more aggressive disease. Accurate detection of metastatic disease is a prerequisite for tailoring further treatment, that is, surgery, pretargeted radioimmunotherapy, or multikinase inhibitor treatment.

DISCLOSURE STATEMENT

The costs of publication of this article were defrayed in part by the payment of page charges. Therefore, and solely to indicate this fact, this article is hereby marked “advertisement” in accordance with 18 USC section 1734.

Acknowledgments

We thank the staffs of the Turku and Helsinki PET Centres, the Turku Cyclotron, and the Radiochemistry Laboratory. We also thank Marketta Halinen. This study was supported by grants from Research Funding of Helsinki and Turku University Central Hospital (Erityisvaltionosuus) and the Cancer Foundation of South-West Finland. No other potential conflict of interest relevant to this article was reported.

Footnotes

  • ↵* Contributed equally to this work.

  • Published online Nov. 3, 2011.

  • © 2011 by Society of Nuclear Medicine

REFERENCES

  1. 1.↵
    1. Kebebew E,
    2. Ituarte PH,
    3. Siperstein AE,
    4. Duh QY,
    5. Clark OH
    . Medullary thyroid carcinoma: clinical characteristics, treatment, prognostic factors, and a comparison of staging systems. Cancer. 2000;88:1139–1148.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Schröder S,
    2. Bocker W,
    3. Baisch H,
    4. et al
    . Prognostic factors in medullary thyroid carcinomas: survival in relation to age, sex, stage, histology, immunocytochemistry, and DNA content. Cancer. 1988;61:806–816.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Lam ET,
    2. Ringel MD,
    3. Kloos RT,
    4. et al
    . Phase II clinical trial of sorafenib in metastatic medullary thyroid cancer. J Clin Oncol. 2010;28:2323–2330.
    OpenUrlAbstract/FREE Full Text
  4. 4.↵
    1. Kraeber-Bodéré F,
    2. Salaun PY,
    3. Oudoux A,
    4. Goldenberg DM,
    5. Chatal JF,
    6. Barbet J
    . Pretargeted radioimmunotherapy in rapidly progressing, metastatic, medullary thyroid cancer. Cancer. 2010;116:1118–1125.
    OpenUrlCrossRefPubMed
  5. 5.↵
    1. Busnardo B,
    2. Girelli ME,
    3. Simioni N,
    4. Nacamulli D,
    5. Busetto E
    . Nonparallel patterns of calcitonin and carcinoembryonic antigen levels in the follow-up of medullary thyroid carcinoma. Cancer. 1984;53:278–285.
    OpenUrlCrossRefPubMed
  6. 6.↵
    1. Engelbach M,
    2. Gorges R,
    3. Forst T,
    4. et al
    . Improved diagnostic methods in the follow-up of medullary thyroid carcinoma by highly specific calcitonin measurements. J Clin Endocrinol Metab. 2000;85:1890–1894.
    OpenUrlCrossRefPubMed
  7. 7.↵
    1. Hoegerle S,
    2. Altehoefer C,
    3. Ghanem N,
    4. Brink I,
    5. Moser E,
    6. Nitzsche E
    . 18F-DOPA positron emission tomography for tumour detection in patients with medullary thyroid carcinoma and elevated calcitonin levels. Eur J Nucl Med. 2001;28:64–71.
    OpenUrlCrossRefPubMed
  8. 8.↵
    1. Koopmans KP,
    2. de Groot JW,
    3. Plukker JT,
    4. et al
    . 18F-dihydroxyphenylalanine PET in patients with biochemical evidence of medullary thyroid cancer: relation to tumor differentiation. J Nucl Med. 2008;49:524–531.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    1. Luster M,
    2. Karges W,
    3. Zeich K,
    4. et al
    . Clinical value of 18-fluorine-fluorodihydroxyphenylalanine positron emission tomography/computed tomography in the follow-up of medullary thyroid carcinoma. Thyroid. 2010;20:527–533.
    OpenUrlCrossRefPubMed
  10. 10.↵
    1. Kauhanen S,
    2. Seppanen M,
    3. Ovaska J,
    4. et al
    . The clinical value of [18F]fluoro-dihydroxyphenylalanine positron emission tomography in primary diagnosis, staging, and restaging of neuroendocrine tumors. Endocr Relat Cancer. 2009;16:255–265.
    OpenUrlAbstract/FREE Full Text
  11. 11.↵
    1. Bergman J,
    2. Haaparanta M,
    3. Lehikoinen P,
    4. Solin O
    . Electrophilic synthesis of 6(18F)fluoro-L-dopa starting from aqueous-(18F)fluoride. J Labelled Comp Radiopharm. 1994;35:476–477.
    OpenUrl
  12. 12.↵
    1. Bogsrud TV,
    2. Karantanis D,
    3. Nathan MA,
    4. et al
    . The prognostic value of 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography in patients with suspected residual or recurrent medullary thyroid carcinoma. Mol Imaging Biol. 2010;12:547–553.
    OpenUrlCrossRefPubMed
  13. 13.↵
    1. Gasparoni P,
    2. Rubello D,
    3. Ferlin G
    . Potential role of fluorine-18-deoxyglucose (FDG) positron emission tomography (PET) in the staging of primitive and recurrent medullary thyroid carcinoma. J Endocrinol Invest. 1997;20:527–530.
    OpenUrlPubMed
  14. 14.
    1. Diehl M,
    2. Risse JH,
    3. Brandt-Mainz K,
    4. et al
    . Fluorine-18 fluorodeoxyglucose positron emission tomography in medullary thyroid cancer: results of a multicentre study. Eur J Nucl Med. 2001;28:1671–1676.
    OpenUrlCrossRefPubMed
  15. 15.
    1. Musholt TJ,
    2. Musholt PB,
    3. Dehdashti F,
    4. Moley JF
    . Evaluation of fluorodeoxyglucose-positron emission tomographic scanning and its association with glucose transporter expression in medullary thyroid carcinoma and pheochromocytoma: a clinical and molecular study. Surgery. 1997;122:1049–1060.
    OpenUrlCrossRefPubMed
  16. 16.
    1. Szakáll S Jr.,
    2. Bajzik G,
    3. Repa I,
    4. et al
    . FDG PET scan of metastases in recurrent medullary carcinoma of the thyroid gland [in Hungarian]. Orv Hetil. 2002;143(21 suppl 3):1280–1283.
    OpenUrlPubMed
  17. 17.
    1. Brandt-Mainz K,
    2. Muller SP,
    3. Gorges R,
    4. Saller B,
    5. Bockisch A
    . The value of fluorine-18 fluorodeoxyglucose PET in patients with medullary thyroid cancer. Eur J Nucl Med. 2000;27:490–496.
    OpenUrlCrossRefPubMed
  18. 18.↵
    1. de Groot JW,
    2. Links TP,
    3. Jager PL,
    4. Kahraman T,
    5. Plukker JT
    . Impact of 18F-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) in patients with biochemical evidence of recurrent or residual medullary thyroid cancer. Ann Surg Oncol. 2004;11:786–794.
    OpenUrlCrossRefPubMed
  19. 19.↵
    1. Adams S,
    2. Baum R,
    3. Rink T,
    4. Schumm-Drager PM,
    5. Usadel KH,
    6. Hor G
    . Limited value of fluorine-18 fluorodeoxyglucose positron emission tomography for the imaging of neuroendocrine tumours. Eur J Nucl Med. 1998;25:79–83.
    OpenUrlCrossRefPubMed
  20. 20.↵
    1. Adams S,
    2. Baum RP,
    3. Hertel A,
    4. Schumm-Drager PM,
    5. Usadel KH,
    6. Hor G
    . Metabolic (PET) and receptor (SPET) imaging of well- and less well-differentiated tumours: comparison with the expression of the Ki-67 antigen. Nucl Med Commun. 1998;19:641–647.
    OpenUrlPubMed
  21. 21.↵
    1. Ahlström H,
    2. Eriksson B,
    3. Bergstrom M,
    4. Bjurling P,
    5. Langstrom B,
    6. Oberg K
    . Pancreatic neuroendocrine tumors: diagnosis with PET. Radiology. 1995;195:333–337.
    OpenUrlPubMed
  22. 22.↵
    1. Hoegerle S,
    2. Altehoefer C,
    3. Ghanem N,
    4. et al
    . Whole-body 18F dopa PET for detection of gastrointestinal carcinoid tumors. Radiology. 2001;220:373–380.
    OpenUrlCrossRefPubMed
  23. 23.
    1. Becherer A,
    2. Szabo M,
    3. Karanikas G,
    4. et al
    . Imaging of advanced neuroendocrine tumors with 18F-FDOPA PET. J Nucl Med. 2004;45:1161–1167.
    OpenUrlAbstract/FREE Full Text
  24. 24.↵
    1. Koopmans KP,
    2. Neels OC,
    3. Kema IP,
    4. et al
    . Improved staging of patients with carcinoid and islet cell tumors with 18F-dihydroxy-phenyl-alanine and 11C-5-hydroxy-tryptophan positron emission tomography. J Clin Oncol. 2008;26:1489–1495.
    OpenUrlAbstract/FREE Full Text
  25. 25.↵
    1. Hoegerle S,
    2. Nitzsche E,
    3. Altehoefer C,
    4. et al
    . Pheochromocytomas: detection with 18F DOPA whole body PET—initial results. Radiology. 2002;222:507–512.
    OpenUrlCrossRefPubMed
  26. 26.↵
    1. Timmers HJ,
    2. Hadi M,
    3. Carrasquillo JA,
    4. et al
    . The effects of carbidopa on uptake of 6-18F-fluoro-L-DOPA in PET of pheochromocytoma and extraadrenal abdominal paraganglioma. J Nucl Med. 2007;48:1599–1606.
    OpenUrlAbstract/FREE Full Text
  27. 27.↵
    1. Hoegerle S,
    2. Ghanem N,
    3. Altehoefer C,
    4. et al
    . 18F-DOPA positron emission tomography for the detection of glomus tumours. Eur J Nucl Med Mol Imaging. 2003;30:689–694.
    OpenUrlPubMed
  28. 28.↵
    1. Kauhanen S,
    2. Seppanen M,
    3. Minn H,
    4. et al
    . Fluorine-18-L-dihydroxyphenylalanine (18F-DOPA) positron emission tomography as a tool to localize an insulinoma or β-cell hyperplasia in adult patients. J Clin Endocrinol Metab. 2007;92:1237–1244.
    OpenUrlCrossRefPubMed
  29. 29.↵
    1. Beuthien-Baumann B,
    2. Strumpf A,
    3. Zessin J,
    4. Bredow J,
    5. Kotzerke J
    . Diagnostic impact of PET with 18F-FDG, 18F-DOPA and 3-O-methyl-6-[18F]fluoro-DOPA in recurrent or metastatic medullary thyroid carcinoma. Eur J Nucl Med Mol Imaging. 2007;34:1604–1609.
    OpenUrlCrossRefPubMed
  30. 30.↵
    1. Beheshti M,
    2. Pocher S,
    3. Vali R,
    4. et al
    . The value of 18F-DOPA PET-CT in patients with medullary thyroid carcinoma: comparison with 18F-FDG PET-CT. Eur Radiol. 2009;19:1425–1434.
    OpenUrlCrossRefPubMed
  31. 31.↵
    1. Marzola MC,
    2. Pelizzo MR,
    3. Ferdeghini M,
    4. et al
    . Dual PET/CT with 18F-DOPA and 18F-FDG in metastatic medullary thyroid carcinoma and rapidly increasing calcitonin levels: comparison with conventional imaging. Eur J Surg Oncol. 2010;36:414–421.
    OpenUrlCrossRefPubMed
  32. 32.↵
    1. Kloos RT,
    2. Eng C,
    3. Evans DB,
    4. et al
    . Medullary thyroid cancer: management guidelines of the American Thyroid Association. Thyroid. 2009;19:565–612.
    OpenUrlCrossRefPubMed
  33. 33.↵
    1. Neels OC,
    2. Koopmans KP,
    3. Jager PL,
    4. et al
    . Manipulation of [11C]-5-hydroxytryptophan and 6-[18F]fluoro-3,4-dihydroxy-L-phenylalanine accumulation in neuroendocrine tumor cells. Cancer Res. 2008;68:7183–7190.
    OpenUrlAbstract/FREE Full Text
  34. 34.↵
    1. Orlefors H,
    2. Sundin A,
    3. Lu L,
    4. et al
    . Carbidopa pretreatment improves image interpretation and visualisation of carcinoid tumours with 11C-5-hydroxytryptophan positron emission tomography. Eur J Nucl Med Mol Imaging. 2006;33:60–65.
    OpenUrlCrossRefPubMed
  • Received for publication June 22, 2011.
  • Accepted for publication September 12, 2011.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 52 (12)
Journal of Nuclear Medicine
Vol. 52, Issue 12
December 1, 2011
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Complementary Roles of 18F-DOPA PET/CT and 18F-FDG PET/CT in Medullary Thyroid Cancer
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Complementary Roles of 18F-DOPA PET/CT and 18F-FDG PET/CT in Medullary Thyroid Cancer
Saila Kauhanen, Camilla Schalin-Jäntti, Marko Seppänen, Sami Kajander, Sami Virtanen, Jukka Schildt, Irina Lisinen, Aapo Ahonen, Ilkka Heiskanen, Mika Väisänen, Johanna Arola, Pirkko Korsoff, Tapani Ebeling, Timo Sane, Heikki Minn, Matti J. Välimäki, Pirjo Nuutila
Journal of Nuclear Medicine Dec 2011, 52 (12) 1855-1863; DOI: 10.2967/jnumed.111.094771

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Complementary Roles of 18F-DOPA PET/CT and 18F-FDG PET/CT in Medullary Thyroid Cancer
Saila Kauhanen, Camilla Schalin-Jäntti, Marko Seppänen, Sami Kajander, Sami Virtanen, Jukka Schildt, Irina Lisinen, Aapo Ahonen, Ilkka Heiskanen, Mika Väisänen, Johanna Arola, Pirkko Korsoff, Tapani Ebeling, Timo Sane, Heikki Minn, Matti J. Välimäki, Pirjo Nuutila
Journal of Nuclear Medicine Dec 2011, 52 (12) 1855-1863; DOI: 10.2967/jnumed.111.094771
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE STATEMENT
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Anti-CEA Pretargeted Immuno-PET Shows Higher Sensitivity Than DOPA PET/CT in Detecting Relapsing Metastatic Medullary Thyroid Carcinoma: Post Hoc Analysis of the iPET-MTC Study
  • False-positive findings on 6-[18F]fluor-L-3,4-dihydroxyphenylalanine PET (18F-FDOPA-PET) performed for imaging of neuroendocrine tumors
  • Immuno-PET Using Anticarcinoembryonic Antigen Bispecific Antibody and 68Ga-Labeled Peptide in Metastatic Medullary Thyroid Carcinoma: Clinical Optimization of the Pretargeting Parameters in a First-in-Human Trial
  • ENDOCRINE TUMOURS: Progressive metastatic medullary thyroid carcinoma: first- and second-line strategies
  • Relevance of Calcitonin Cut-off in the Follow-up of Medullary Thyroid Carcinoma for Conventional Imaging and 18-Fluorine-Fluorodihydroxyphenylalanine PET
  • Clinical Relevance of 18F-FDG PET and 18F-DOPA PET in Recurrent Medullary Thyroid Carcinoma
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire