Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleBasic Science Investigations

Intraoperative Near-Infrared Fluorescence Tumor Imaging with Vascular Endothelial Growth Factor and Human Epidermal Growth Factor Receptor 2 Targeting Antibodies

Anton G.T. Terwisscha van Scheltinga, Gooitzen M. van Dam, Wouter B. Nagengast, Vasilis Ntziachristos, Harry Hollema, Jennifer L. Herek, Carolien P. Schröder, Jos G.W. Kosterink, Marjolijn N. Lub-de Hoog and Elisabeth G.E. de Vries
Journal of Nuclear Medicine November 2011, 52 (11) 1778-1785; DOI: https://doi.org/10.2967/jnumed.111.092833
Anton G.T. Terwisscha van Scheltinga
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Gooitzen M. van Dam
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Wouter B. Nagengast
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Vasilis Ntziachristos
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Harry Hollema
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jennifer L. Herek
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Carolien P. Schröder
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jos G.W. Kosterink
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Marjolijn N. Lub-de Hoog
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Elisabeth G.E. de Vries
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Abstract

Fluorescence imaging is currently attracting much interest as a method for intraoperative tumor detection, but most current tracers lack tumor specificity. Therefore, this technique can be further improved by tumor-specific detection. With tumor-targeted antibodies bound to a radioactive label, tumor-specific SPECT or PET is feasible in the clinical setting. The aim of the present study was to apply antibody-based tumor detection to intraoperative optical imaging, using preclinical in vivo mouse models. Methods: Anti–vascular endothelial growth factor (VEGF) antibody bevacizumab and anti–human epidermal growth factor receptor (HER) 2 antibody trastuzumab were labeled with the near-infrared (NIR) fluorescence dye IRDye 800CW. Tumor uptake of the fluorescent tracers and their 89Zr-labeled radioactive counterparts for PET was determined in human xenograft–bearing athymic mice during 1 wk after tracer injection, followed by ex vivo biodistribution and pathologic examination. Intraoperative imaging of fluorescent VEGF- or HER2-positive tumor lesions was performed in subcutaneous tumors and in intraperitoneal dissemination tumor models. Results: Tumor-to-background ratios, with fluorescent imaging, were 1.93 ± 0.40 for bevacizumab and 2.92 ± 0.29 for trastuzumab on day 6 after tracer injection. Real-time intraoperative imaging detected tumor lesions at even the submillimeter level in intraperitoneal dissemination tumor models. These results were supported by standard histology, immunohistochemistry, and fluorescence microscopy analyses. Conclusion: NIR fluorescence–labeled antibodies targeting VEGF or HER2 can be used for highly specific and sensitive detection of tumor lesions in vivo. These preclinical findings encourage future clinical studies with NIR fluorescence–labeled tumor-specific antibodies for intraoperative-guided surgery in cancer patients.

  • molecular imaging
  • monoclonal antibodies
  • oncology
  • intraoperative imaging
  • near-infrared fluorescence

Fluorescence imaging is currently attracting much interest as a method for superior intraoperative tumor detection, but most current imaging tracers lack tumor specificity. Therefore, combining know-how obtained from targeted therapies such as the use of monoclonal antibodies and expertise on molecular imaging for targeted tumor tracer development might greatly benefit the patient in such a setting.

Molecular imaging is the in vivo characterization and measurement of biologic processes at the cellular and molecular levels (1). Most experience in translating this approach into the clinic has taken place with PET and SPECT in oncology (2). Initially, the focus in radionuclide imaging was on the visualization of general tumor processes such as glucose consumption with 18F-FDG PET and DNA proliferation with 3′-deoxy-3′-18F-fluorothymidine. However, the availability of novel targeted tracers and new detection systems for clinical use has expanded the potential of molecular imaging even into the intraoperative setting. A wide variety of tumor characteristics can now be visualized using tracers based on monoclonal antibodies (3). We developed the PET radiopharmaceuticals 89Zr-labeled bevacizumab to image vascular endothelial growth factor (VEGF) and 89Zr-trastuzumab to image human epidermal growth factor receptor 2 (HER2) in tumors and tested them successfully preclinically and clinically (4–7). Bevacizumab is a humanized monoclonal antibody that neutralizes all isoforms of the ligand VEGF-A (8,9); trastuzumab, the antihuman HER2 monoclonal antibody, targets the extracellular domain of HER2 (10).

Fluorescence imaging in the intraoperative setting has recently entered the clinical testing phase. This technique uses light instead of ionizing radiation, is real-time, provides high-resolution imaging, and is relatively inexpensive (2,11). However, compared with PET, optical imaging does not provide noninvasive whole-body imaging, and there exists a limited penetration depth of the signal. There are currently a few intraoperative imaging systems operational in the clinic (12,13), but there is still an unmet need for tumor-specific detection with tumor-specific fluorescent tracers. Our intraoperative tumor-targeted imaging approach of using a small ligandlike folate linked to a fluorophore (i.e., fluoresceine isothiocyanate), which targets specifically the folate-α receptor in ovarian cancer patients, will provide the proof-of-principle concept (Netherlands Trial Register 1980; http://www.trialregister.nl). However, because of tissue-scattering properties, autofluorescence, and absorption of light in the 400- to 650-nm range, the use of near-infrared (NIR) fluorophores is more attractive for deeper-seated tumors with respect to sensitivity and accuracy. Such a tracer should preferably perform in the NIR fluorescence spectrum, which uses light in the 650- to 900-nm spectrum. In this spectrum, autofluorescence signals are thus minimized, and there is the lowest tissue absorption of light, resulting in optimal tissue penetration (14). However, few NIR fluorescence tracers are currently available for use in the clinic, and all are nontargeted. Recently, various groups have reported experience with the introduction of image-guided surgery for the detection of the sentinel node in breast cancer and cervical cancer patients with the NIR fluorescence tracer indocyanine green (13,15).

The use of tumor-specific targeted intraoperative imaging can potentially be expanded to detect tumor margins, locoregional metastases, and residual disease after surgery. We therefore decided to test whether we could translate the excellent performance of radiolabeled bevacizumab and trastuzumab into optical imaging with a clinically applicable tumor-targeted fluorescent tracer. IRDye 800CW is a NIR fluorophore with optimal characteristics for clinical use, allowing binding to antibodies when used in its N-hydroxysuccinimide (NHS) ester form. A preclinical toxicity study with IRDye 800CW carboxylate showed no toxicity in doses of up to 20 mg/kg intravenously or intradermally (16).

To develop IRDye 800CW–labeled bevacizumab and trastuzumab for specific tumor detection in vivo, we verified the results with 89Zr-bevacizumab and 89Zr-trastuzumab PET. To this end, in vivo mouse models were used with human tumor xenografts for VEGF imaging and HER2 imaging. Intraoperative surgery with the clinically used NIR camera was performed in both subcutaneous and intraperitoneal dissemination tumor models.

MATERIALS AND METHODS

Cell Lines

The human ovarian cancer cell line A2780 (HER2-negative,with high VEGF production) was kindly provided by Dr. Thomas C. Hamilton (Fox Chase Cancer Center). Development of the luciferase-transfected subline A2780luc+ was described by Duiker et al. (17). The SK-BR-3 (HER2-overexpressing) breast cancer and KATO-III (HER2-overexpressing) gastric cancer cell lines were obtained from American Type Culture Collection. The ovarian cancer cell line SKOV-3luc+ (HER2-overexpressing) was obtained from Caliper Life Sciences. Cell lines were quarantined until screening for microbial contamination and mycoplasm had been performed; these tests were negative. Meanwhile, a reproducible supply of cells was established by cryopreservation.

All experiments were performed within a predefined number of passages. Key features of the cell lines were routinely checked. Growth and morphology of the cells was observed and noted to be consistent with prior descriptions of the lines. A2780luc+ cells were cultured in RPMI 1640 (Invitrogen), supplemented with 10% heat-inactivated fetal calf serum (Bodinco BV) and 2 mM L-glutamine (Invitrogen). SK-BR-3 and SKOV-3luc+ were cultured in Dulbecco's modified Eagle medium (Invitrogen) supplemented with 10% fetal calf serum and KATO-III in RPMI 1640 medium supplemented with 20% fetal calf serum. All cell lines were cultured at 37°C in a fully humidified atmosphere containing 5% CO2.

Bevacizumab and Trastuzumab Labeling with IRDye 800CW and In Vitro Evaluation of Fluorescence-Labeled Compounds

IRDye 800CW-NHS (Li-Cor Biosciences) was coupled to bevacizumab (Roche) and trastuzumab (Roche) according to the manufacturer's protocol. In short, antibodies were reacted with IRDye 800CW at a molar ratio of 1:4 in phosphate-buffered saline (pH 8.5), which was determined as the optimal ratio. The product was purified by ultracentrifugation with Vivaspin sample concentrators (GE Healthcare). Labeling efficiency and purity were determined by size-exclusion high-performance liquid chromatography, with ultraviolet detector wavelengths at 220, 280, and 790 nm. The labeling efficiency obtained was 85%–90%, giving a labeling ratio of an average of 3.5 dyes per antibody, with a purity of greater than 95% after purification. The stability of bevacizumab-800CW and trastuzumab-800CW was verified by storing the final product in 1 mL of 0.9% sodium chloride at 4°C and 37°C for 7 d. Size-exclusion high-performance liquid chromatography measurements were performed for 1 wk. No measurable decreases in bound IRDye 800CW were found. The binding properties to VEGF of bevacizumab-800CW were evaluated using a VEGF-coated enzyme-linked immunosorbent assay, as described previously by Nagengast et al. (4). Binding of the antibody to the antigen was measured with the Odyssey imaging system (Li-Cor Biosciences). Trastuzumab-800CW binding properties were determined using a competition assay with unlabeled trastuzumab on SK-BR-3 cells stitched to a 96-well plate with poly-L-lysine (0.01% w/v in water; Sigma-Aldrich). Both bevacizumab-800CW and trastuzumab-800CW showed no decrease in-binding affinity.

Bevacizumab and Trastuzumab Conjugation and 89Zr Labeling

Conjugation and radiolabeling of bevacizumab and trastuzumab were performed as described earlier (4,5). Briefly, both antibodies were first conjugated with the chelator tetrafluorphenol N-succinyldesferal (TFP-N-sucDf), which was kindly provided by Dr. Guus A. van Dongen (VU Medical Center). After conjugation, the product was purified by ultracentrifugation and stored at −20°C. In the second step, the conjugated antibodies were radiolabeled with clinical-grade 89Zr-oxalate (IBA Molecular). Because PET is more quantitative than SPECT, we used 89Zr-labeled antibodies instead of the 111In-labeled analogs.

IgG Conjugation and 111In Labeling

Human IgG (Sanquin) was used as an aspecific control in the experiments. Human IgG conjugation and labeling were performed as described by Ruegg et al. (18). Briefly, IgG was first conjugated to the bifunctional conjugating agent 2-(4-isothiocyanatobenzyl)-diethylenetriaminepentaacetic acid (p-SCN-Bn-DTPA; Macrocyclics). After conjugation, the product was stored at −20°C. Conjugated human IgG was radiolabeled with 111In-chloride (Covidien).

Glassware, materials, and solutions used for the 89Zr and 111In conjugation and labeling procedures were sterilized, pyrogen-free, and metal-free. All radiolabeled antibodies had a purity of greater than 95% before administration to the animals.

Animal Experiments

For subcutaneous tumor models, cells were harvested by trypsinization and resuspended in phosphate-buffered saline. In vivo imaging and ex vivo experiments were conducted using male nude BALB-c mice (BALB/cOlaHSD-foxnnu) obtained from Harlan Nederland. Mice were not kept on a specific diet. At 6–8 wk of age, the mice were injected subcutaneously with 5 × 106 A2780luc+ (n = 10) or 2.5 × 106 SK-BR-3 (n = 10) cells in 0.3 mL of Matrigel (BD Bioscience). A2780luc+ was selected for these experiments given its high VEGF tumor levels when xenografted and the characterization of 89Zr-bevacizumab available in this model (4). Trastuzumab-800CW was tested in the SK-BR-3 tumor–bearing mice.

Tumor growth was followed with caliper measurements. The tracer was injected when the tumors measured 6–8 mm in diameter (for A2780, 2 wk after tumor cell inoculation; for SK-BR-3, 4 wk after inoculation). To compare fluorescence optical imaging with PET, mice received a coinjection of IRDye 800CW- and 89Zr (5 MBq)-labeled bevacizumab or trastuzumab together with the same protein dose of 111In-IgG (1 MBq) as an aspecific control. During a scan sequence, images were made immediately after injection of the tracer and at 24, 48, 72, and 144 h afterward. Two protein doses were tested per tracer: for bevacizumab, 30 and 100 μg, and for trastuzumab, 50 and 100 μg. Half of the tracer protein dose was labeled fluorescently, correlating with 0.41, 0.68, and 1.36 μg of dye for, respectively, 30, 50, and 100 μg of protein, based on a labeling ratio of 3.5 molecules of dye per antibody. The difference in lowest protein dose used was different for bevacizumab and trastuzumab, because a difference in maximal specific activity could be obtained. Tracer injection was via the penile vein in a volume of 150 μL.

Animals were imaged using a microPET Focus 220 rodent scanner (CTI Siemens). After image reconstruction, in vivo quantification was performed with AMIDE's a Medical Image Data Examiner software (version 0.9.1; Stanford University) (19). The data were presented as the mean standardized uptake value (SUVmean), which analyzes tumor uptake by comparing it with the total average whole-body uptake. Animals were sacrificed after the last scan, and organs and tissues were excised and weighed. Samples and primed standards were counted for radioactivity in a calibrated well-type LKB-1282 Compu-γ system (LKB Wallac) and corrected for physical decay. Ex vivo tissue activity was expressed as percentage of the injected dose per gram of tissue. Harvested tumors were paraffin-embedded for further analysis.

In vivo fluorescence and bioluminescence images were obtained with the IVIS Spectrum (Caliper Life Sciences). Fluorescence images were retrieved by measuring a spectrum with different excitation wavelengths of 675 and 745 nm and using a filter of 800 nm. Data were analyzed using Living Image 3.2 software (Caliper Life Sciences). To determine tumor-to-background ratio (TBR) from NIR fluorescence images, the tumor boundary was set as a region of interest, and the ratio was calculated by comparing the tumor uptake with the background value within the mouse. The TBR was determined after spectral unmixing of the fluorescence signal, performed by Living Image software, to distinguish the IRDye 800CW signal from autofluorescence.

Bioluminescence was achieved by injecting the animals intraperitoneally weekly with D-luciferin (150 mg/kg; Xenogen) reconstituted in phosphate-buffered saline, followed by imaging.

The real-time intraoperative multispectral fluorescence imaging system as developed by Themelis et al. (12) was used to visualize the location of the fluorescence-labeled antibodies. This system contains 3 cameras operating in parallel: a color and fluorescence camera and an intrinsic camera for light attenuation images at the excitation wavelength. Images and videos were obtained during surgery and ex vivo studies. Figures were made with Photoshop (version CS4; Adobe) for creation of the overlay pictures.

Female nude BALB-c mice (BALB/cOlaHSD-foxnnu) with A2780luc+ (n = 5), SKOV-3luc+ (n = 10), and KATO-III (n = 5) cells were used for intraperitoneal dissemination tumor models. Mice were kept on an alfalfa-free diet to reduce autofluorescence in the peritoneum. A total of 2 × 106, 5 × 106, or 2 × 106 cells were injected intraperitoneally (volume, 0.5 mL). Tumor growth was tracked with weekly bioluminescence measurements in mice that received cells of a luciferase-positive cell line, using the IVIS Spectrum. The fluorescent tracer was injected intraperitoneally 3 wk after inoculation of A2780luc+ and KATO-III and 4 wk after SKOV-3luc+. Ten mice inoculated with the A2780luc+ (n = 5) or SKOV-3luc+ (n = 5) received 100 μg of bevacizumab-800CW. Trastuzumab-800CW (100 μg) was administered in 5 mice inoculated with SKOV-3luc+ and 5 mice with KATO-III tumors. On day 4 after tracer injection, all mice received isoflurane inhalation anesthesia (induction, 3%; maintenance, 1.5%) to undergo NIR fluorescent imaging during surgery.

To validate the findings with the intraoperative fluorescence imaging system, 1 animal from each group was also scanned in the IVIS Spectrum system. If present, at least 3 fluorescent spots were excised intraoperatively for pathologic and fluorescence microscopy analysis. Harvested fluorescent lesions were paraffin-embedded for further analysis. During surgery, intraoperative imaging was performed by recording still images and movies. After this procedure, the mice were sacrificed. The animal experiments were approved by the animal experiments committee of the University of Groningen.

Ex Vivo Tissue Analysis

Paraffin-embedded subcutaneous tumors and fluorescent intraperitoneal lesions were stained with hematoxylin and eosin (H&E) and immunohistochemically for VEGF (SC-152; Santa Cruz) or HER2 (CB11; Neomarkers).

Hoechst staining (33258; Invitrogen) was used to visualize nuclei for fluorescence microscopy. Fluorescence microscopy analysis was performed using an Olympus Fluoview 300 confocal scan box mounted on an Olympus IX 71 inverted microscope. The laser source (Coherent; Paladin) produces photons of 532 and 1,064 nm. The optical parametric oscillator (APE Berlin) converts photons to longer wavelengths (20). In this setting, the 532-nm photons are converted to 770 nm, serving to visualize the IRDye 800CW bound to the antibody. Light at 1,064 nm was used to visualize the Hoechst nuclear staining by 2-photon fluorescence. The filter set consisted of the combination of 2 band-pass filters (850-90m-2p; Chroma) and long-pass emission filters (HQ795LP; Chroma). Image analysis was performed using FV10-ASW (version 1.6; Chroma).

Statistical Analysis

Data are presented as mean ± SD. Statistical analysis was performed using the Mann–Whitney test for nonparametric data (Prism, version 5; GraphPad Software). A P value of 0.05 or less was considered significant.

RESULTS

Dual-Modality VEGF Imaging

First, we compared the characteristics of fluorescence-labeled bevacizumab with 89Zr-bevacizumab (Figs. 1A and 1B). In the luciferase-positive tumors, an increasing bioluminescence signal was observed during tumor growth, providing assurance about the vitality of most tumor cells. Quantification of tumor uptake by TBR of the optical fluorescence images revealed an increased signal with a higher fluorescent tracer protein dose of bevacizumab-800CW (Fig. 1A). The TBR was 1.35 ± 0.11 in the 30-μg bevacizumab group and 1.93 ± 0.40 in the 100-μg bevacizumab group (P = 0.014) at 6 d after tracer injection. The tumor SUVmean of 89Zr-bevacizumab was slightly lower in the 100-μg bevacizumab group than in the 30-μg group (Fig. 1B). Optical and nuclear imaging showed an increasing tumor signal over time. Specificity of 89Zr-bevacizumab tumor uptake was shown as 89Zr-bevacizumab tumor uptake ex vivo, compared with 111In-IgG as nonspecific tumor uptake. There was a 64.7% increased uptake in the 30-μg bevacizumab group (P < 0.0001) and 53.2% (P < 0.0049) increased uptake in the 100-μg bevacizumab group, compared with the IgG tumor uptake.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Dual-modality imaging of VEGF in subcutaneous A2780luc+ xenograft model. (A) Representative sagittal (2-dimensional) fluorescence images of bevacizumab-800CW immediately after tracer injection of 100 μg of bevacizumab and at indicated days, and relative tumor uptake displayed in TBR. (B) Correlated coronal small-animal PET images after 89Zr-bevacizumab injection, and tumor uptake (SUVmean) as determined by small-animal PET data quantification for both dose groups (30 and 100 μg of bevacizumab).

Dual-Modality HER2 Imaging

Next, we compared the characteristics of fluorescence-labeled trastuzumab with 89Zr-trastuzumab. Quantification of tumor uptake by TBR of the optical fluorescence images showed a dose-related effect, with 1.67 ± 0.18 at 50 μg and 2.92 ± 0.29 at 100 μg of trastuzumab (P < 0.0001) (Fig. 2A). The tumor uptake in the low-dose trastuzumab group was already maximal at day 1 after injection. The optimal time point for measuring fluorescence was comparable to VEGF imaging: between 3 and 6 d after fluorescent tracer injection, based on increasing TBR. The maximum 89Zr-trastuzumab tumor uptake, measured with small-animal PET, was similar for the 50- and 100-μg trastuzumab groups (Fig. 2B). The specificity of this 89Zr-trastuzumab tumor uptake, shown as tumor uptake of 111In-IgG (coinjected), was less in both groups: 74.0% in the 100-μg protein dose group (P = 0.0016) and 91.2% in the 50-μg protein dose group (P < 0.0001).

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Dual-modality imaging of HER2 in subcutaneous SK-BR-3 xenograft model. (A) Representative sagittal (2-dimensional) fluorescence images of trastuzumab-800CW immediately after tracer injection of 100 μg of trastuzumab and at indicated days, and relative tumor uptake displayed in TBR. (B) Correlated coronal small-animal PET images after 89Zr- trastuzumab injection, and tumor uptake (SUVmean) as determined by small-animal PET data quantification (50 and 100 μg of trastuzumab).

Use of NIR Fluorescence–Labeled Antibodies for Intraoperative Guidance

Tumor uptake of the fluorescence-labeled antibodies was clearly visible with the intraoperative fluorescent system in mice receiving bevacizumab-800CW (Fig. 3) or trastuzumab-800CW (Supplemental Fig. 1A; supplemental materials are available online only at http://jnm.snmjournals.org). The fluorescence signal of the subcutaneous tumor was detectable despite the intact skin overlying the tumor.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Representative intraoperative images of bevacizumab-800CW in subcutaneous A2780 tumor–bearing mouse. Ovarian cancer was targeted with bevacizumab-800CW. Weaker background fluorescence of stomach comes from fluorescence of chlorophyll in food of animals used in these groups. These mice were not kept on alfalfa-free diet.

Supplemental Video 1 shows the fluorescence signal of trastuzumab-800CW captured by the intraoperative fluorescence imaging system while the surgeon removes the subcutaneous SK-BR-3 tumor.

Tumor models with high peritoneal metastatic spread were used to investigate whether the fluorescence-labeled antibodies were able to visualize small tumor spots in the peritoneal cavity.

In mice bearing the luciferase-positive cell lines, increasing bioluminescence was observed over time after inoculation, indicating tumor growth and vitality of tumor cells.

For bevacizumab-800CW and trastuzumab-800CW, even submillimeter lesions could be distinguished intraoperatively by the emitted fluorescence signal. Peroperative images for bevacizumab-800CW are shown in Supplemental Figures 2A and 2B. Both ovarian cancer models showed intraperitoneal tumor growth measured with bioluminescence imaging. For the HER2-overexpressing SKOV-3luc+, small tumor lesions could be visualized with bevacizumab-800CW (Supplemental Fig. 2B) and with trastuzumab-800CW (Supplemental Fig. 1B) with the intraoperative camera. Trastuzumab-800CW was also able to visualize the HER2-positive KATO-III tumor lesions (Fig. 4). Lesions were found ranging from submillimeter size to several centimeters. In addition, lesions smaller than 1 mm were removed from the peritoneum on the basis of the fluorescence signal.

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

Intraoperative images of trastuzumab-800CW in human gastric cancer KATO-III intraperitoneal tumor model.

The intense fluorescence signal correlates with tumor lesions as measured with bioluminescence, indicating specific tumor uptake and detection of lesions by fluorescence signal during imaging. The fluorescence signal is present where vital tumor cells are shown using bioluminescent imaging of A2780luc+ tumors with bevacizumab-800CW (Supplemental Fig. 3A) and SKOV-3luc+ tumors with trastuzumab-800CW (Supplemental Fig. 3B).

Supplemental Video 2 shows the experimental setting of intraoperative imaging during surgery on a mouse. The fluorescence signal of bevacizumab-800CW was captured during removal of intraperitoneal SKOV-3luc+ tumor spots as a representative example.

Tumor-Specific Detection with NIR Fluorescence–Labeled Antibodies

H&E staining, VEGF staining, and fluorescence microscopy showed that the lesions with fluorescence signals contained tumor cells; this is illustrated for the A2780luc+ subcutaneous tumor in Figure 5. The same results were found in small intraperitoneal lesions of the intraperitoneally injected A2780luc+ and SKOV-3luc+. Comparably, in the SK-BR-3 subcutaneous tumor, viable tumor cells were detected with H&E, HER2, and fluorescence microscopy (Fig. 5). SKOV-3luc+ and KATO-III intraperitoneal fluorescent lesions also showed viable tumor cells. As expected, fluorescence microscopy showed bevacizumab-800CW in the extracellular matrix of the tumor, whereas trastuzumab-800CW fluorescence was detected mainly on the tumor cell surface.

FIGURE 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 5.

A2780 subcutaneous tumor microscopy images (×400) showing H&E staining, VEGF staining, and fluorescence signal of bevacizumab-800CW (green) and nuclei visualized by fluorescence after Hoechst staining (red), and SK-BR-3 subcutaneous tumor microscopy images (×400) showing H&E staining, HER2 staining, and fluorescence signal of trastuzumab-800CW (green) and nuclei (red). IHC = immunohistochemistry.

DISCUSSION

These results are the first, to our knowledge, to show that tumor-targeted NIR fluorescence–labeled therapeutic antibodies can be used for specific tumor detection in vivo in a preclinical setting, using the real-time intraoperative clinical prototype camera system.

In the present study, the excellent selective tumor uptake previously shown with PET of 89Zr-bevacizumab and 89Zr-trastuzumab in mice bearing human xenografts (4,5) was also observed for the same antibodies labeled with a fluorescent dye.

The TBR obtained for trastuzumab-800CW was somewhat higher than for bevacizumab-800CW. This can at least partially be explained by the fact that bevacizumab targets only human VEGF, which is produced by the implanted human tumor cells. In the human xenograft tumor models, murine VEGF also plays a role, but bevacizumab does not bind or neutralize murine VEGF (21,22). This assumption is supported by the finding that the radioactive bevacizumab tracer showed a lower tumor uptake in the preclinical setting than in patients (6,7).

89Zr-bevacizumab and 89Zr-trastuzumab showed high specific tumor uptake, with increasing TBRs during the first 4 d after tracer injection (6,7). The long half-life of the antibodies implies that these antibodies require days to accumulate optimally in the tumor. Our clinical studies with 89Zr-bevacizumab and 89Zr-trastuzumab indicated that day 4 after tracer injection is optimal for nuclear imaging. In the present study, the optimal time for optical imaging for both antibodies was around day 3 after fluorescent tracer injection. Our results with the IRDye 800CW–labeled antibodies directing against VEGF and HER2 revealed the possibility of detecting submillimeter lesions with a clinical intraoperative camera.

This information adds to the recent data obtained for fluorescence-labeled antibodies targeting the epidermal growth factor receptor (EGFR), HER2, and the insulin-like growth factor receptor 1 (IGF-1R) (23–26). Cetuximab labeled with the NIR fluorescent dye Cy5.5 showed specific tumor uptake in head and neck squamous cell carcinoma xenografts (23), whereas the IGF-1R targeting antibody AVE-1642 labeled with the NIR fluorescent dye Alexa 680 was specifically taken up by the R-/IGF-1R xenograft tumor (24). Trastuzumab that was dual-labeled with 111In-DTPA and IRDye 800CW showed a similar tumor-to-muscle ratio of 2.25 for fluorescence measurements and 2.66 in a SK-BR-3luc+ model for SPECT (25). Although these results are promising, no clinical trials have yet been performed with these targeted fluorescent labels. This specific uptake—not only of HER2 and VEGF but also of epidermal growth factor receptor– and IGF-1R–directed antibodies labeled with a fluorescent tracer—further supports the potential to expand our findings to several other targets that could be visualized in tumor tissues of patients with optical imaging when labeled with clinical-grade IRDye 800CW. No NIR-targeted tracers are currently available for clinical use; the tracers discussed in this article could fill this gap in future clinical studies.

Currently, the only NIR fluorescence tracer approved by the Food and Drug Administration for human use is indocyanine green, but it is not a targeted tracer. To address this problem, the antibodies daclizumab (targets CD25), panitumumab (targets HER1), and trastuzumab (targets HER2) were labeled with activatable NIR fluorescent tracers of indocyanine green. They were tested in the preclinical setting and indeed visualized the tumors (26). However, because indocyanine green loses its fluorescence once it is covalently bound to protein, the fluorescence becomes visible only after activation due to cellular internalization of the tracer and degradation of the antibody (26,27). Consequently, this approach cannot visualize VEGF, which is mainly present in the extracellular matrix. This approach could also underestimate the signal, for example, in the case of growth factor receptors such as HER2. In that case, apart from internalization of the receptor, there will also be a receptor at the cell membrane (as demonstrated in fluorescent microscopy results) that will not lead to a fluorescence signal. Our fluorescent microscopic analysis of IRDye 800CW clearly showed that the signal originates precisely where it was expected for both tracers: for bevacizumab-800CW, between tumor cells in the microenvironment, and for trastuzumab-800CW, intracellularly and on the tumor cell surface.

The dose of labeled antibodies required for molecular imaging in patients is in the subtherapeutic microdose ranges. When antibodies have a linear kinetic profile, no supplementation of unlabeled antibody is necessary for PET. This is the case for U36, a CD44v6-specific murine monoclonal antibody, and for bevacizumab (28–30). Therefore, imaging studies in patients with these 89Zr-labeled antibodies were performed with 10 mg for U36 and 5 mg for bevacizumab (7,31). For optical clinical imaging purposes, comparable protein doses will be used. The case is different for trastuzumab, which has dose-dependent pharmacokinetics. After multiple therapeutic doses, trastuzumab clearance has an average terminal half-life of 28.5 d at steady state (32). However, when given as a single dose of 10 mg, trastuzumab has a terminal half-life of only 1.5 d (33), too short to allow adequate accumulation of the tracer in the tumors and subsequent imaging. In the 89Zr-trastuzumab study, supplementation with 50 mg of unlabeled trastuzumab was optimal (6). This aspect will have to be considered for the imaging with trastuzumab-800CW as well.

Given the interesting characteristics of IRDye 800CW for use in the clinic, we are currently performing the preclinical toxicity testing of bevacizumab-800CW to permit clinical trials with this tracer. However, the best optical imaging may require a cocktail of tracers targeting different tumor characteristics. For example, it is becoming increasingly clear that breast cancer is a heterogeneous disease that can exhibit a variety of characteristics. These experiments indicate that both tracers can be of interest for the clinic, depending on the presence of the target in the tumor. Compared with HER2, VEGF is the more general target for cancer detection, because it is more frequently overexpressed in many tumor types (8).

Apart from intraoperative image-guided surgery, fluorescence imaging systems are also being developed for diffuse optical imaging, hand-held photo-acoustic–based imaging, fluorescent endoscopy, and confocal laser endomicroscopy (34–36). When used for studying breast tissue, diffuse optical imaging is often referred to as optical mammography. This technique is currently being tested in early clinical trials (37). Confocal laser endomicroscopy allows in vivo imaging of the mucosal layer during gastrointestinal endoscopy. Interestingly, the feasibility of VEGF imaging in a preclinical gastrointestinal cancer model and human tissue using confocal laser endomicroscopy was recently demonstrated using a polyclonal rabbit antibody raised against the -121, -165, and -89 isoforms of human and murine VEGF labeled with Alexa-Fluor 488 (34). The VEGF-specific signal was visualized and correlated well with ex vivo microscopy. The first clinical trials using confocal laser endomicroscopy with tumor targeted fluorescent tracers are expected to start soon.

CONCLUSION

In a preclinical setting, NIR fluorescence–labeled antibodies targeting VEGF or HER2 allowed highly specific and sensitive detection of tumor lesions in vivo. These findings strongly support future clinical studies with NIR fluorescence–labeled tumor-specific antibodies in a wide range of clinical applications, including intraoperative image-guided surgery.

DISCLOSURE STATEMENT

The costs of publication of this article were defrayed in part by the payment of page charges. Therefore, and solely to indicate this fact, this article is hereby marked “advertisement” in accordance with 18 USC section 1734.

Acknowledgments

We thank Martin Jurna, Leila Nahidi Azar, Lucy Crane, Rick Pleijhuis, Esther van Straten, Michiel Bolkestein, Thijs Oude Munnink, and Linda Pot for their technical assistance. This study was supported by grants RUG 2010-4603 and RUG 2009-4273 from the Dutch Cancer Society. No other potential conflict of interest relevant to this article was reported.

Footnotes

  • Published online Oct. 11, 2011.

  • © 2011 by Society of Nuclear Medicine

REFERENCES

  1. 1.↵
    1. Weissleder R,
    2. Mahmood U
    . Molecular imaging. Radiology. 2001;219:316–333.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Pysz MA,
    2. Gambhir SS,
    3. Willmann JK
    . Molecular imaging: current status and emerging strategies. Clin Radiol. 2010;65:500–516.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. van Dongen GA,
    2. Vosjan MJ
    . Immuno-positron emission tomography: shedding light on clinical antibody therapy. Cancer Biother Radiopharm. 2010;25:375–385.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Nagengast WB,
    2. de Vries EG,
    3. Hospers GA,
    4. et al
    . In vivo VEGF imaging with radiolabeled bevacizumab in a human ovarian tumor xenograft. J Nucl Med. 2007;48:1313–1319.
    OpenUrlAbstract/FREE Full Text
  5. 5.↵
    1. Dijkers EC,
    2. Kosterink JG,
    3. Rademaker AP,
    4. et al
    . Development and characterization of clinical-grade 89Zr-trastuzumab for HER2/neu immunoPET imaging. J Nucl Med. 2009;50:974–981.
    OpenUrlAbstract/FREE Full Text
  6. 6.↵
    1. Dijkers EC,
    2. Oude Munnink TH,
    3. Kosterink JG,
    4. et al
    . Biodistribution of 89Zr-trastuzumab and PET imaging of HER2-positive lesions in patients with metastatic breast cancer. Clin Pharmacol Ther. 2010;87:586–592.
    OpenUrlCrossRefPubMed
  7. 7.↵
    1. Oosting SF,
    2. Nagengast WB,
    3. Oude Munnink TH,
    4. et al
    . 89Zr-bevacizumab PET imaging in renal cell carcinoma patients: feasibility of tumor VEGF quantification. Eur J Cancer. 2010;7(suppl):72–73.
    OpenUrl
  8. 8.↵
    1. Ferrara N,
    2. Davis-Smyth T
    . The biology of vascular endothelial growth factor. Endocr Rev. 1997;18:4–25.
    OpenUrlCrossRefPubMed
  9. 9.↵
    1. Gerber HP,
    2. Ferrara N
    . Pharmacology and pharmacodynamics of bevacizumab as monotherapy or in combination with cytotoxic therapy in preclinical studies. Cancer Res. 2005;65:671–680.
    OpenUrlAbstract/FREE Full Text
  10. 10.↵
    1. Moasser MM
    . The oncogene HER2: its signaling and transforming functions and its role in human cancer pathogenesis. Oncogene. 2007;26:6469–6487.
    OpenUrlCrossRefPubMed
  11. 11.↵
    1. Frangioni JV
    . New technologies for human cancer imaging. J Clin Oncol. 2008;26:4012–4021.
    OpenUrlAbstract/FREE Full Text
  12. 12.↵
    1. Themelis G,
    2. Yoo JS,
    3. Soh KS,
    4. Schulz R,
    5. Ntziachristos V
    . Real-time intraoperative fluorescence imaging system using light-absorption correction. J Biomed Opt. 2009;14:064012.
    OpenUrlCrossRefPubMed
  13. 13.↵
    1. Troyan SL,
    2. Kianzad V,
    3. Gibbs-Strauss SL,
    4. et al
    . The FLARE intraoperative near-infrared fluorescence imaging system: a first-in-human clinical trial in breast cancer sentinel lymph node mapping. Ann Surg Oncol. 2009;16:2943–2952.
    OpenUrlCrossRefPubMed
  14. 14.↵
    1. Hilderbrand SA,
    2. Weissleder R
    . Near-infrared fluorescence: application to in vivo molecular imaging. Curr Opin Chem Biol. 2010;14:71–79.
    OpenUrlCrossRefPubMed
  15. 15.↵
    1. Crane LM,
    2. Themelis G,
    3. Pleijhuis RG,
    4. et al
    . Intraoperative multispectral fluorescence imaging for the detection of the sentinel lymph node in cervical cancer: a novel concept. Mol Imaging Biol. 2011;13:1043–1049.
    OpenUrlCrossRefPubMed
  16. 16.↵
    1. Marshall MV,
    2. Draney D,
    3. Sevick-Muraca EM,
    4. Olive DM
    . Single-dose intravenous toxicity study of IRDye 800CW in Sprague-Dawley rats. Mol Imaging Biol. 2010;12:583–594.
    OpenUrlCrossRefPubMed
  17. 17.↵
    1. Duiker EW,
    2. de Vries EG,
    3. Mahalingam D,
    4. et al
    . Enhanced antitumor efficacy of a DR5-specific TRAIL variant over recombinant human TRAIL in a bioluminescent ovarian cancer xenograft model. Clin Cancer Res. 2009;15:2048–2057.
    OpenUrlAbstract/FREE Full Text
  18. 18.↵
    1. Ruegg CL,
    2. Anderson-Berg WT,
    3. Brechbiel MW,
    4. Mirzadeh S,
    5. Gansow OA,
    6. Strand M
    . Improved in vivo stability and tumor targeting of bismuth-labeled antibody. Cancer Res. 1990;50:4221–4226.
    OpenUrlAbstract/FREE Full Text
  19. 19.↵
    1. Loening AM,
    2. Gambhir SS
    . AMIDE: a free software tool for multimodality medical image analysis. Mol Imaging. 2003;2:131–137.
    OpenUrlCrossRefPubMed
  20. 20.↵
    1. Jurna M,
    2. Korterik JP,
    3. Offerhaus HL,
    4. et al
    . Noncritical phase-matched lithium triborate optical parametric oscillator for high resolution coherent anti-Stokes Raman scattering spectroscopy and microscopy. Appl Phys Lett. 2006;89:251116.
    OpenUrlCrossRef
  21. 21.↵
    1. Yu L,
    2. Wu X,
    3. Cheng Z,
    4. et al
    . Interaction between bevacizumab and murine VEGF-A: a reassessment. Invest Ophthalmol Vis Sci. 2008;49:522–527.
    OpenUrlAbstract/FREE Full Text
  22. 22.↵
    1. Lee S,
    2. Chen TT,
    3. Barber CL,
    4. et al
    . Autocrine VEGF signaling is required for vascular homeostasis. Cell. 2007;130:691–703.
    OpenUrlCrossRefPubMed
  23. 23.↵
    1. Rosenthal EL,
    2. Kulbersh BD,
    3. King T,
    4. Chaudhuri TR,
    5. Zinn KR
    . Use of fluorescent labeled anti-epidermal growth factor receptor antibody to image head and neck squamous cell carcinoma xenografts. Mol Cancer Ther. 2007;6:1230–1238.
    OpenUrlAbstract/FREE Full Text
  24. 24.↵
    1. Zhang H,
    2. Zeng X,
    3. Li Q,
    4. Gaillard-Kelly M,
    5. Wagner CR,
    6. Yee D
    . Fluorescent tumour imaging of type I IGF receptor in vivo: comparison of antibody-conjugated quantum dots and small-molecule fluorophore. Br J Cancer. 2009;101:71–79.
    OpenUrlCrossRefPubMed
  25. 25.↵
    1. Sampath L,
    2. Kwon S,
    3. Ke S,
    4. et al
    . Dual-labeled trastuzumab-based imaging agent for the detection of human epidermal growth factor receptor 2 overexpression in breast cancer. J Nucl Med. 2007;48:1501–1510.
    OpenUrlAbstract/FREE Full Text
  26. 26.↵
    1. Ogawa M,
    2. Kosaka N,
    3. Choyke PL,
    4. Kobayashi H
    . In vivo molecular imaging of cancer with a quenching near-infrared fluorescent probe using conjugates of monoclonal antibodies and indocyanine green. Cancer Res. 2009;69:1268–1272.
    OpenUrlAbstract/FREE Full Text
  27. 27.↵
    1. Kobayashi H,
    2. Choyke PL
    . Target-cancer-cell-specific activatable fluorescence imaging probes: Rational design and in vivo applications. Acc Chem Res. 2011;44:83–90.
    OpenUrlCrossRefPubMed
  28. 28.↵
    1. de Bree R,
    2. Roos JC,
    3. Quak JJ,
    4. den Hollander W,
    5. Snow GB,
    6. van Dongen GA
    . Radioimmunoscintigraphy and biodistribution of technetium-99m-labeled monoclonal antibody U36 in patients with head and neck cancer. Clin Cancer Res. 1995;1:591–598.
    OpenUrlAbstract
  29. 29.
    1. Colnot DR,
    2. Quak JJ,
    3. Roos JC,
    4. et al
    . Phase I therapy study of 186Re-labeled chimeric monoclonal antibody U36 in patients with squamous cell carcinoma of the head and neck. J Nucl Med. 2000;41:1999–2010.
    OpenUrlAbstract/FREE Full Text
  30. 30.↵
    1. Gordon MS,
    2. Margolin K,
    3. Talpaz M,
    4. et al
    . Phase I safety and pharmacokinetic study of recombinant human anti-vascular endothelial growth factor in patients with advanced cancer. J Clin Oncol. 2001;19:843–850.
    OpenUrlAbstract/FREE Full Text
  31. 31.↵
    1. Börjesson PK,
    2. Jauw YW,
    3. Boellaard R,
    4. et al
    . Performance of immuno-positron emission tomography with zirconium-89-labeled chimeric monoclonal antibody U36 in the detection of lymph node metastases in head and neck cancer patients. Clin Cancer Res. 2006;12:2133–2140.
    OpenUrlAbstract/FREE Full Text
  32. 32.↵
    1. Bruno R,
    2. Washington CB,
    3. Lu JF,
    4. Lieberman G,
    5. Banken L,
    6. Klein P
    . Population pharmacokinetics of trastuzumab in patients with HER2+ metastatic breast cancer. Cancer Chemother Pharmacol. 2005;56:361–369.
    OpenUrlCrossRefPubMed
  33. 33.↵
    US Food and Drug Administration. FDA Clinical Review of Herceptin 98-0369: Herceptin Trastuzumab (rhuMAb HER2). Available at: http://www.fda.gov/downloads/Drugs/DevelopmentApprovalProcess/HowDrugsareDevelopedandApproved/ApprovalApplications/TherapeuticBiologicApplications/ucm091373.pdf. Accessed September 14, 2011.
  34. 34.↵
    1. Foersch S,
    2. Kiesslich R,
    3. Waldner MJ,
    4. et al
    . Molecular imaging of VEGF in gastrointestinal cancer in vivo using confocal laser endomicroscopy. Gut. 2010;59:1046–1055.
    OpenUrlAbstract/FREE Full Text
  35. 35.
    1. Ntziachristos V,
    2. Razansky D
    . Molecular imaging by means of multispectral optoacoustic tomography (MSOT). Chem Rev. 2010;110:2783–2794.
    OpenUrlCrossRefPubMed
  36. 36.↵
    1. van de Ven SM,
    2. Elias SG,
    3. van den Bosch MA,
    4. Luijten P,
    5. Mali WP
    . Optical imaging of the breast. Cancer Imaging. 2008;8:206–215.
    OpenUrlCrossRefPubMed
  37. 37.↵
    1. van de Ven S,
    2. Wiethoff A,
    3. Nielsen T,
    4. et al
    . A novel fluorescent imaging agent for diffuse optical tomography of the breast: first clinical experience in patients. Mol Imaging Biol. 2010;12:343–348.
    OpenUrlCrossRefPubMed
  • Received for publication May 18, 2011.
  • Accepted for publication July 14, 2011.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 52 (11)
Journal of Nuclear Medicine
Vol. 52, Issue 11
November 1, 2011
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Intraoperative Near-Infrared Fluorescence Tumor Imaging with Vascular Endothelial Growth Factor and Human Epidermal Growth Factor Receptor 2 Targeting Antibodies
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Intraoperative Near-Infrared Fluorescence Tumor Imaging with Vascular Endothelial Growth Factor and Human Epidermal Growth Factor Receptor 2 Targeting Antibodies
Anton G.T. Terwisscha van Scheltinga, Gooitzen M. van Dam, Wouter B. Nagengast, Vasilis Ntziachristos, Harry Hollema, Jennifer L. Herek, Carolien P. Schröder, Jos G.W. Kosterink, Marjolijn N. Lub-de Hoog, Elisabeth G.E. de Vries
Journal of Nuclear Medicine Nov 2011, 52 (11) 1778-1785; DOI: 10.2967/jnumed.111.092833

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Intraoperative Near-Infrared Fluorescence Tumor Imaging with Vascular Endothelial Growth Factor and Human Epidermal Growth Factor Receptor 2 Targeting Antibodies
Anton G.T. Terwisscha van Scheltinga, Gooitzen M. van Dam, Wouter B. Nagengast, Vasilis Ntziachristos, Harry Hollema, Jennifer L. Herek, Carolien P. Schröder, Jos G.W. Kosterink, Marjolijn N. Lub-de Hoog, Elisabeth G.E. de Vries
Journal of Nuclear Medicine Nov 2011, 52 (11) 1778-1785; DOI: 10.2967/jnumed.111.092833
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE STATEMENT
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Roadmap for the Development and Clinical Translation of Optical Tracers Cetuximab-800CW and Trastuzumab-800CW
  • Molecular Imaging of Radiolabeled Bispecific T-Cell Engager 89Zr-AMG211 Targeting CEA-Positive Tumors
  • Determination of Tumor Margins with Surgical Specimen Mapping Using Near-Infrared Fluorescence
  • Intraoperative Resection Guidance with Photoacoustic and Fluorescence Molecular Imaging Using an Anti-B7-H3 Antibody-Indocyanine Green Dual Contrast Agent
  • Tumor-Specific Uptake of Fluorescent Bevacizumab-IRDye800CW Microdosing in Patients with Primary Breast Cancer: A Phase I Feasibility Study
  • Targeted Dual-Modality Imaging in Renal Cell Carcinoma: An Ex Vivo Kidney Perfusion Study
  • Molecular Imaging of Ovarian Cancer
  • Biodistribution and PET Imaging of Labeled Bispecific T Cell-Engaging Antibody Targeting EpCAM
  • Fluorescent Image-Guided Surgery with an Anti-Prostate Stem Cell Antigen (PSCA) Diabody Enables Targeted Resection of Mouse Prostate Cancer Xenografts in Real Time
  • Molecular Fluorescence Endoscopy Targeting Vascular Endothelial Growth Factor A for Improved Colorectal Polyp Detection
  • Antibody Positron Emission Tomography Imaging in Anticancer Drug Development
  • Detection of Peritoneal Dissemination with Near-infrared Fluorescence Laparoscopic Imaging Using a Liposomal Formulation of a Synthesized Indocyanine Green Liposomal Derivative
  • SPECT- and Fluorescence Image-Guided Surgery Using a Dual-Labeled Carcinoembryonic Antigen-Targeting Antibody
  • Optical Imaging of Renal Cell Carcinoma with Anti-Carbonic Anhydrase IX Monoclonal Antibody Girentuximab
  • In Vivo Visualization of MET Tumor Expression and Anticalin Biodistribution with the MET-Specific Anticalin 89Zr-PRS-110 PET Tracer
  • 89Zr-Bevacizumab PET Imaging in Primary Breast Cancer
  • Bevacizumab-Induced Normalization of Blood Vessels in Tumors Hampers Antibody Uptake
  • An Optical Probe for Noninvasive Molecular Imaging of Orthotopic Brain Tumors Overexpressing Epidermal Growth Factor Receptor
  • Molecular Imaging of Tumors with Radioactive Labeled Antibodies from Laboratory to the Clinic
  • Google Scholar

More in this TOC Section

  • Synthesis and Biologic Evaluation of Novel 18F-Labeled Probes Targeting Prostate-Specific Membrane Antigen for PET of Prostate Cancer
  • Tumor-Specific Binding of Radiolabeled PEGylated GIRLRG Peptide: A Novel Agent for Targeting Cancers
  • PET/MRI of Hypoxic Atherosclerosis Using 64Cu-ATSM in a Rabbit Model
Show more Basic Science Investigations

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire