Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
OtherClinical Investigations

18F-FDG PET in Evaluation of Adrenal Lesions in Patients with Lung Cancer

Rakesh Kumar, Yan Xiu, Jian Q. Yu, Amol Takalkar, Ghassan El-Haddad, Scott Potenta, Justin Kung, Hongming Zhuang and Abass Alavi
Journal of Nuclear Medicine December 2004, 45 (12) 2058-2062;
Rakesh Kumar
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yan Xiu
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jian Q. Yu
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Amol Takalkar
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ghassan El-Haddad
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Scott Potenta
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Justin Kung
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hongming Zhuang
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Abass Alavi
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

The purpose of this study was to assess the role of PET with 18F-FDG in differentiating benign from metastatic adrenal masses detected on CT or MRI scans of patients with lung cancer. Methods: This retrospective study analyzed 18F-FDG PET scans of patients with lung cancer who were found to have an adrenal mass on CT or MRI scans. One hundred thirteen adrenal masses (75 unilateral and 19 bilateral; size range, 0.8–4.7 cm) were evaluated in 94 patients. PET findings were interpreted as positive if the 18F-FDG uptake of the adrenal mass was greater than or equal to that of the liver. PET findings were interpreted as negative if the 18F-FDG uptake of the adrenal mass was less than that of the liver. All studies were reviewed independently by 3 nuclear medicine physicians, and the results were then correlated with clinical follow-up or biopsy results when available. Results: PET findings were positive in 71 adrenal masses. Sixty-seven of these were eventually considered to be metastatic adrenal disease. In the remaining 4, no changes in lesion size were noted on follow-up examinations. PET findings were negative in 42 adrenal masses, of which 37 eventually proved to be benign. Among the 5 adrenal masses that were false-negative, one was a large necrotic metastasis; 1 was a 2.4-cm lesion with central hemorrhaging, and the remaining 3 were lesions of less than 11 mm. The sensitivity, specificity, and accuracy for detecting metastatic disease were 93%, 90%, and 92%, respectively. Conclusion: 18F-FDG PET is an accurate, noninvasive technique for differentiating benign from metastatic adrenal lesions detected on CT or MRI in patients with lung cancer. In addition, PET has the advantage of assessing the primary cancer sites and detecting other metastases.

  • 18F-FDG PET
  • lung cancer
  • adrenal masses
  • CT
  • adrenal metastases

Lung cancer is the most common cause of death in men from cancer and increasingly more common in women. Five-year survival has improved among lung cancer patients who have limited disease and undergo surgery (1,2). However, the disease stage of most patients will actually be increased when they undergo surgical exploration, thus preventing them from being candidates for surgical intervention. There is a need for more accurate preoperative staging to better select appropriate candidates for surgery. Autopsy series have shown a high occurrence of adrenal metastases in patients with lung cancer, ranging from 35% to 59% (3,4). The incidence of adrenal masses in clinical studies of patients with non–small cell lung carcinoma (NSCLC) may vary from 4.1% to 18% (5). However, not all adrenal masses can be assumed to represent metastasis, because 2%–9% of the general population has been shown to harbor benign adenomas (6). Therefore, it is important to characterize adrenal masses accurately when they are discovered in patients with lung cancer. Percutaneous biopsy remains the gold standard for confirmation of the nature of the lesion. However, percutaneous biopsy is an invasive technique often associated with complications. The diagnostic accuracy of aspirated material ranges from 80% to 100% (7).

Noninvasive imaging techniques, which include CT and MRI, have been used to differentiate metastases from benign adrenal adenoma. CT has shown usefulness because of its ability to measure attenuation, on both unenhanced images and on delayed contrast-enhanced images, to differentiate benign from malignant lesions (8,9). But diagnosis based on attenuation measurement is often not feasible in unenhanced or delayed contrast-enhanced CT (10). MRI has shown initial promise in T2-weighted and chemical shift imaging, but the signal intensity of benign and malignant lesions overlaps considerably (11,12). Recently, 18F-FDG PET has shown encouraging results in differentiating benign from metastatic adrenal masses in patients with known or suspected malignancies (13–15). However, only a few studies, with few patients, on the use of 18F-FDG PET for evaluating adrenal masses in lung cancer patients have been reported in the literature (16,17). This study investigated the usefulness of 18F-FDG PET in the evaluation of adrenal masses detected on CT or MR imaging of patients with lung cancer.

MATERIALS AND METHODS

Patients

From 1999 to 2003, 94 patients (49 men and 45 women; age range, 35–86 y; mean age ± SD, 65 ± 11 y) who presented with a diagnosis of lung cancer and adrenal mass detected on CT or MRI were included in this study. A total of 113 adrenal lesions (75 unilateral and 19 bilateral) based on reports of CT or MRI from referring physicians were evaluated. The size of the adrenal lesions on CT or MRI scans ranged from 0.5 to 5.4 cm, with a mean of 2.6 cm. All patients underwent 18F-FDG PET for primary staging or evaluation of metastatic disease. The final diagnosis of the adrenal lesion was based on clinical follow-up or histopathologic examination of biopsy specimens, when available. An adrenal lesion was considered benign if it had not changed for at least 6 mo, and it was considered malignant if the size had increased or decreased after treatment or if a new adrenal lesion had developed.

18F-FDG PET Imaging

PET was performed on a dedicated whole-body scanner (Allegro; Philips Medical System, or C-PET; ADAC UGM). The patients fasted for at least 4 h to ensure a serum glucose level below 140 mg/dL for all patients. PET was initiated 60 min after intravenous administration of 2.516–5.2 MBq (0.068–0.14 mCi) of 18F-FDG per kilogram of body weight. Sequential overlapping scans were acquired to cover the neck, chest, abdomen, and pelvis. Transmission scans using a 137Cs point source were interleaved between the multiple emission scans to correct for nonuniform attenuation. The images were reconstructed using an iterative reconstruction algorithm, and both attenuation-corrected and non–attenuation-corrected images were interpreted.

18F-FDG PET Image Interpretation

Three nuclear medicine physicians who were unaware of other clinical or imaging information independently interpreted the 18F-FDG PET images. The interpretation included a review of both uncorrected and attenuation-corrected scans. Special attention was given to 18F-FDG uptake in the region of the adrenal glands. PET findings were interpreted as positive if the 18F-FDG uptake of the adrenal mass was greater than or equal to that of the liver. PET findings were interpreted as negative if the 18F-FDG uptake of the adrenal mass was less than that of the liver. In cases of disagreement, a final decision was made by consensus. On the basis of past experience, we have noted that visual assessment of suspected lesions may be just as effective in differentiating active from inactive disease as is semiquantitative analysis using the standardized uptake value (13). Therefore, the standardized uptake value was not used to differentiate a benign adrenal lesion from a malignant adrenal lesion. Furthermore, it was often difficult to generate a region of interest over lesions that were not visualized on PET images.

RESULTS

Table 1 shows the characteristics of all patients. Of the 113 lesions, 71 were positive for 18F-FDG uptake. Sixty-seven of these were eventually considered—after surgery (n = 4), percutaneous biopsy (n = 8), autopsy (n = 2), or clinical follow-up (n = 53)—to represent metastatic adrenal disease. The remaining 4 showed no change in size on follow-up CT, MRI, or PET. Forty-two lesions were negative for 18F-FDG uptake. Thirty-seven of these were eventually proven—either by surgery (n = 3), percutaneous biopsy (n = 5), or clinical follow-up for at least 6 mo (n = 29)—to be benign. Among the 5 adrenal masses that gave false-negative findings, 1 was a large necrotic metastasis, 1 was a 2.4-cm lesion with central hemorrhaging, and the remaining 3 were lesions of 8, 9, and 11 mm.

View this table:
  • View inline
  • View popup
TABLE 1

Patient Characteristics

Among all the metastatic adrenal lesions, 90% (65/72) had significantly higher 18F-FDG uptake and 2 had 18F-FDG uptake equal to or slightly higher than that of the liver (Figs. 1 and 2). Of the remaining 5 metastases, in which 18F-FDG uptake was less than that of the liver, 1 had necrosis, 1 had central hemorrhaging, and 3 were small lesions on CT. Ten of the 65 metastatic lesions that had significantly higher 18F-FDG uptake than that of the liver also had a central photopenic area surrounded by intense 18F-FDG uptake suggestive of central necrosis (Fig. 3). Of the 41 benign lesions, one had 18F-FDG uptake significantly higher than that of the liver, 3 lesions had uptake equal to or slightly greater than that of the liver, and 37 had uptake equal to that of the background (Fig. 4). The lesion that had 18F-FDG uptake significantly higher than that of the liver was found to be pheochromocytoma by positive findings on 99mTc-pentetreotide scanning. Three lesions that had uptake equal to or slightly higher than that of the liver did not show any change in uptake or size on follow-up PET and CT scans and were therefore considered to be benign adenomas.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

(A) 18F-FDG PET scan shows intense, bilateral uptake in adrenal masses. (B) CT scan shows bilateral adrenal masses (arrows); left adrenal lesion is larger, with irregular borders. (C) 18F-FDG PET axial view at same level as for CT shows intense, bilateral uptake in adrenal masses.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

(A) 18F-FDG PET scan shows intense uptake in right adrenal mass and uptake slightly higher than that of liver in left adrenal mass. (B) CT scan shows bilateral adrenal masses; right adrenal lesion is larger than left (arrows). (C) 18F-FDG PET axial view at same level as for CT shows intense uptake in right adrenal mass and uptake slightly higher than that of liver in left adrenal mass (arrows).

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

(A) 18F-FDG PET scan shows intense uptake in right adrenal mass, with central photopenic area. (B) CT scan shows large right adrenal mass with central lower-attenuation area indicating central necrosis (arrow). (C) 18F-FDG PET axial view at same level as for CT shows intense uptake in right adrenal mass, with central photopenic area indicating central necrosis (arrow).

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

(A) 18F-FDG PET scan shows no uptake in the region of either adrenal. (B) CT scan shows soft-tissue masses in both adrenal glands (arrows). (C) 18F-FDG PET axial view at same level as for CT shows no abnormal uptake in the region of either adrenal.

Table 2 illustrates the 18F-FDG PET results and final outcome. The sensitivity, specificity, and accuracy for detecting metastatic disease were 93%, 90%, and 92%, respectively. The positive predictive value was 94%, and the negative predictive value was 88%.

View this table:
  • View inline
  • View popup
TABLE 2

PET Findings and Final Diagnosis for 113 Adrenal Lesions

DISCUSSION

Adrenal metastases originating from NSCLC and small cell lung carcinoma are not uncommon. It is estimated that up to 4% of patients with otherwise operable NSCLC will have a unilateral adrenal mass; up to 40% of these may be malignant and present as a solitary site of metastasis (18). Detection of adrenal metastases in these patients has major clinical implications because an isolated ipsilateral adrenal metastasis in a patient with resectable primary NSCLC is considered to be localized disease (19). Resection of isolated adrenal metastases has been shown to improve the long-term disease-free survival of these patients. Luketich and Burt showed improved survival in patients with NSCLC and solitary adrenal metastasis when treated by surgical resection after chemotherapy, compared with treatment by chemotherapy alone (31 vs. 8.5 mo) (20). Therefore, accurate differentiation of benign from metastatic adrenal masses is essential for optimal management of patients with lung cancer.

CT is considered most important in evaluating adrenal masses. The CT attenuation value has been helpful in differentiating benign adenomas from malignant lesions (21). Unenhanced CT can reliably characterize adrenal masses using density measurements of the adrenal gland. However, controversy exists as to the optimal density threshold required to differentiate benign from malignant lesions. Sensitivity for characterizing a lesion as benign has ranged from 47% at a threshold of 2 HU to 88% at a threshold of 20 HU in a metaanalysis of 10 CT studies (8). Delayed enhanced CT could help by analyzing the washout patterns seen in adrenal lesions (9). Adenomas demonstrate rapid washout after administration of intravenous contrast medium. Diagnosis of adrenal adenomas based on attenuation measurement at unenhanced or delayed contrast-enhanced CT is often not feasible in clinical practice. Unenhanced CT scans are not obtained routinely, and patients frequently leave the department before the contrast-enhanced CT scans are reviewed. The usefulness of mean CT attenuation of adrenal masses at contrast-enhanced CT is limited because there is too much overlap between the 2 groups to accurately differentiate between adrenal adenomas and nonadenomas (21,22). Signal intensity on T2-weighted MR images and chemical-shift MR sequences are most commonly used to differentiate benign adenomas from malignancy. Any lipid-containing tissue would show a signal loss caused by cancellation of the signal from fat and water. However, signal intensity overlaps considerably between benign and malignant lesions (11,12). Burt et al. reported false-positive results for 67% of 25 adrenal lesions in their prospective study (18).

Unlike CT and MRI, 18F-FDG PET is based on increased glucose metabolism in malignant lesions. However, in the literature only limited data are available on the role of 18F-FDG PET in patients with lung cancer and adrenal masses (Table 3). But the results of these studies are encouraging and justify the use of 18F-FDG PET in the management of lung cancer patients. Boland et al. reported a sensitivity and specificity of 100% with 18F-FDG PET in 20 patients with cancer (14). Of these 20 patients, 10 had lung cancer. Erasmus et al. (16) evaluated 33 adrenal masses in 27 patients with bronchogenic carcinoma. PET findings were interpreted as positive when 18F-FDG uptake was higher in the adrenal mass than in the background. The sensitivity for detecting metastasis was 100%, and the specificity was 80%. Gupta et al. (17) studied 30 patients with lung cancer and considered adrenal 18F-FDG uptake to be abnormal when it was higher than background liver uptake. 18F-FDG PET showed abnormally increased 18F-FDG uptake in 17 of 18 malignant lesions. In benign lesions, PET was true negative in 11 of 12 lesions. Yun et al. (13) interpreted the 18F-FDG uptake of the adrenal as positive if it was equal to or greater than that of the liver. The authors reported a sensitivity of 100%, a specificity of 94%, and an accuracy of 96% in 41 patients, 30 of whom had lung cancer.

View this table:
  • View inline
  • View popup
TABLE 3

Results of Published 15F-FDG PET Studies on Patients with Lung Cancer and Adrenal Lesions

In the present study, 18F-FDG PET showed a high sensitivity of 93%, a specificity of 90%, a positive predictive value of 94%, a negative predictive value of 88%, and an accuracy of 92% to differentiate between benign and malignant adrenal masses in patients with lung cancer. The results of our study were similar to the results of previously published studies using 18F-FDG PET to assess adrenal masses in cancer patients. All previously published studies and the present study had a sensitivity and accuracy of more than 92% for PET. The common causes of false-positive 18F-FDG PET results are pheochromocytomas and benign adenomas (13,23). Among our false-positive PET results, 3 were in patients with adenomas and one in a patient with pheochromocytoma. Pheochromocytoma, whether benign or malignant, has been shown to accumulate 18F-FDG, although uptake is found in a greater percentage of malignant pheochromocytomas (23). The common causes of false-negative PET results are small lesion size, necrotic metastases, and metastases from neuroendocrine tumors (13,24). In the present series, we had 5 false-negative lesions: 1 necrotic metastasis, 1 metastasis with central hemorrhaging, and 3 small metastatic lesions. Small metastatic lesions can be missed because of the limited resolution of PET or the absence of sufficient tumor cells with increased glycolysis.

Our results are similar to those of Yun et al. and indicate that if a lesion shows 18F-FDG uptake less than or significantly higher than that of the liver, the study can be interpreted with high confidence (13). Adrenal lesions with an 18F-FDG uptake equal to or slightly higher than that of the liver should be read as indeterminate since these properties can be seen in either benign or malignant lesions. In such patients, additional imaging with MRI should be performed to further characterize the lesions.

CONCLUSION

18F-FDG PET is an accurate, noninvasive technique for differentiating benign from metastatic adrenal lesions detected on CT or MRI in patients with lung cancer. In addition, PET has the advantage of assessing the primary cancer site and detecting other metastases. These results suggest the importance of 18F-FDG PET in the management of these patients, especially since a solitary adrenal metastasis is considered to be treatable.

Footnotes

  • Received Mar. 15, 2004; revision accepted Aug. 12, 2004.

    For correspondence or reprints contact: Abass Alavi, MD, Division of Nuclear Medicine, Hospital of the University of Pennsylvania, 110 Donner Bldg., 3400 Spruce St., Philadelphia, PA, 19104.

    E-mail: alavi{at}rad.upenn.edu

REFERENCES

  1. ↵
    Sorensen HR, Lund C, Alstrup P. Survival in small cell lung carcinoma after surgery. Thorax. 1986;41:479–482.
    OpenUrlAbstract/FREE Full Text
  2. ↵
    Shah SS, Thompson J, Goldstraw P. Results of operation without adjuvant therapy in the treatment of small cell lung cancer. Ann Thorac Surg. 1992;54:498–501.
    OpenUrlCrossRefPubMed
  3. ↵
    Engelman RM, McNamara WL. Bronchiogenic carcinoma: a statistical review of 2 hundred and 34 autopsies. J Thorac Surg. 1954;27:227–237.
    OpenUrl
  4. ↵
    Ettinghausen SE, Burt ME. Prospective evaluation of unilateral adrenal masses in patients with operable nonsmall-cell lung cancer. J Clin Oncol. 1991;9:1462–1466.
    OpenUrlAbstract
  5. ↵
    Chapman GS, Kumar D, Redmond J III, Munderloh SH, Gandara DR. Upper abdominal computerized tomography scanning in staging nonsmall cell lung carcinoma. Cancer. 1984;54:1541–1543.
    OpenUrlCrossRefPubMed
  6. ↵
    Hedeland H, Ostberg G, Hokfelt B. On the prevalence of adrenocortical adenomas in an autopsy material in relation to hypertension and diabetes. Acta Med Scand. 1968;184:211–214.
    OpenUrlPubMed
  7. ↵
    Dunnick NR. Adrenal imaging: current status. AJR. 1990;154:927–936.
    OpenUrlPubMed
  8. ↵
    Boland GW, Lee MJ, Gazelle GS, Halpern EF, McNicholas MM, Mueller PR. Characterization of adrenal masses using unenhanced CT: an analysis of the CT literature. AJR. 1998;171:201–204.
    OpenUrlCrossRefPubMed
  9. ↵
    Caoili EM, Korobkin M, Francis IR, et al. Adrenal masses: characterization with combined unenhanced and delayed enhanced CT. Radiology. 2002;222:629–633.
    OpenUrlCrossRefPubMed
  10. ↵
    Bae KT, Fuangtharnthip P, Prasad SR, Joe BN, Heiken JP. Adrenal masses: CT characterization with histogram analysis method. Radiology. 2003;228:735–742.
    OpenUrlPubMed
  11. ↵
    Glazer GM, Woolsey EJ, Borrello J, et al. Adrenal tissue characterization using MR imaging. Radiology. 1986;158:73–79.
    OpenUrlPubMed
  12. ↵
    Tsushima Y, Ishizaka H, Matsumoto M. Adrenal masses: differentiation with chemical shift, fast low-angle shot MR imaging. Radiology. 1993;186:705–709.
    OpenUrlPubMed
  13. ↵
    Yun M, Kim W, Alnafisi N, Lacorte L, Jang S, Alavi A. 18F-FDG PET in characterizing adrenal lesions detected on CT or MRI. J Nucl Med. 2001;42:1795–1799.
    OpenUrlAbstract/FREE Full Text
  14. ↵
    Boland GW, Goldberg MA, Lee MJ, et al. Indeterminate adrenal mass in patients with cancer: evaluation at PET with 2-[18F]-fluoro-2-deoxy-d-glucose. Radiology. 1995;194:131–134.
    OpenUrlPubMed
  15. ↵
    Maurea S, Mainolfi C, Bazzicalupo L, et al. Imaging of adrenal tumors using FDG PET: comparison of benign and malignant lesions. AJR. 1999;173:25–29.
    OpenUrlCrossRefPubMed
  16. ↵
    Erasmus JJ, Patz EF Jr, McAdams HP, et al. Evaluation of adrenal masses in patients with bronchogenic carcinoma using 18F-FDG PET. AJR. 1997;168:1357–1360.
    OpenUrlPubMed
  17. ↵
    Gupta NC, Graeber GM, Tamim WJ, Rogers JS, Irisari L, Bishop HA. Clinical utility of PET-FDG imaging in differentiation of benign from malignant adrenal masses in lung cancer. Clin Lung Cancer. 2001;3:59–64.
    OpenUrlPubMed
  18. ↵
    Burt M, Heelan RT, Coit D, et al. Prospective evaluation of unilateral adrenal masses in patients with operable nonsmall-cell lung cancer: impact of MRI. J Thorac Cardiovasc Surg. 1994;107:584–588.
    OpenUrlPubMed
  19. ↵
    Kocijancic I, Vidmar K, Zwitter M, Snoj M. The significance of adrenal metastases from lung carcinoma. Eur J Surg Oncol. 2003;29:87–88.
    OpenUrlCrossRefPubMed
  20. ↵
    Luketich JD, Burt ME. Does resection of adrenal metastases from nonsmall cell lung cancer improve survival? Ann Thorac Surg. 1996;62:1614–1616.
    OpenUrlCrossRefPubMed
  21. ↵
    Lee MJ, Hahn PF, Papanicolaou N, et al. Benign and malignant adrenal masses: CT distinction with attenuation coefficients, size, and observer analysis. Radiology. 1991;179:415–418.
    OpenUrlPubMed
  22. ↵
    Korobkin M, Brodeur FJ, Yutzy GG, et al. Differentiation of adrenal adenomas from nonadenomas using CT attenuation values. AJR. 1996;166;531–536.
    OpenUrlCrossRefPubMed
  23. ↵
    Shulkin BL, Thompson NW, Shapiro B, Francis IR, Sisson JC. Pheochromocytomas: imaging with 2-[18F]fluoro-2-deoxy-d-glucose PET. Radiology. 1999;212:35–41.
    OpenUrlPubMed
  24. ↵
    Erasmus JJ, McAdams HP, Patz EF Jr, et al. Evaluation of primary pulmonary carcinoid tumors using FDG PET. AJR. 1998;170:1369–1373.
    OpenUrlCrossRefPubMed
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 45 (12)
Journal of Nuclear Medicine
Vol. 45, Issue 12
December 1, 2004
  • Table of Contents
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
18F-FDG PET in Evaluation of Adrenal Lesions in Patients with Lung Cancer
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
18F-FDG PET in Evaluation of Adrenal Lesions in Patients with Lung Cancer
Rakesh Kumar, Yan Xiu, Jian Q. Yu, Amol Takalkar, Ghassan El-Haddad, Scott Potenta, Justin Kung, Hongming Zhuang, Abass Alavi
Journal of Nuclear Medicine Dec 2004, 45 (12) 2058-2062;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
18F-FDG PET in Evaluation of Adrenal Lesions in Patients with Lung Cancer
Rakesh Kumar, Yan Xiu, Jian Q. Yu, Amol Takalkar, Ghassan El-Haddad, Scott Potenta, Justin Kung, Hongming Zhuang, Abass Alavi
Journal of Nuclear Medicine Dec 2004, 45 (12) 2058-2062;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • THIS MONTH IN JNM
  • PubMed
  • Google Scholar

Cited By...

  • Appropriate Use Criteria for 18F-FDG PET/CT in Restaging and Treatment Response Assessment of Malignant Disease
  • Assessment of incidental and clinically unsuspected fluorodeoxyglucose-avid foci detected on oncological positron emission tomography/CT
  • Utilisation of combined 18F-FDG PET/CT scan for differential diagnosis between benign and malignant adrenal enlargement
  • Asymmetric Intense Bilateral Adrenal Uptake on [18F]Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in a Patient With Solitary Pulmonary Nodule
  • The role of positron emission tomography in the management of non-small cell lung cancer
  • Definitive characterisation of adrenal lesions
  • Integrated PET/CT in the staging of nonsmall cell lung cancer: technical aspects and clinical integration
  • PET/CT assessment of clinically unsuspected, incidental FDG-avid lesions in oncological patients
  • Outcomes of Adrenalectomy for Isolated Synchronous Versus Metachronous Adrenal Metastases in Non-Small-Cell Lung Cancer: A Systematic Review and Pooled Analysis
  • Role of Modern Imaging Techniques for Diagnosis of Infection in the Era of 18F-Fluorodeoxyglucose Positron Emission Tomography
  • Adrenal Masses in the Cancer Patient: Surveillance or Excision
  • Upper pole of a duplex kidney mimicking adrenal incidentaloma in 18F-fluoro-2-deoxy-D-glucose positron emission tomography: a pitfall in diagnosis
  • 18F-FDG PET/CT in the Evaluation of Adrenal Masses
  • Modern Treatment of Lung Cancer: CASE 3. Non-Metastatic Bilateral F-18 Fluorodeoxyglucose Avid Adrenal Glands in Non-Small-Cell Lung Cancer
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire