Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
LetterLetter to the Editor

Good Voxel Dosimetry with a Simplified Study Design Resulted in Improvable Safety Limits

Carlo Chiesa, Matteo Bagnalasta and Marco Maccauro
Journal of Nuclear Medicine February 2024, 65 (2) 331-332; DOI: https://doi.org/10.2967/jnumed.113.129353
Carlo Chiesa
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Matteo Bagnalasta
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Marco Maccauro
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
  • PDF
Loading

TO THE EDITOR: In a paper recently published by The Journal of Nuclear Medicine, Watanabe et al. claimed theirs was “the first study to show superiority for voxel-based dosimetry over multicompartment dosimetry in the prediction of liver decompensation of [hepatocellular carcinoma] patients undergoing radioembolization with 90Y glass microspheres” (1). As dosimetrists we cannot be anything but glad for this success, which pursued a methodology that Carlo Chiesa defended in a point–counterpoint debate with objective difficulty due to the scarce available evidence (2). As a matter of fact, previous efforts by our group (3) were not able to demonstrate a significant “superiority for voxel-based dosimetry in the pretherapeutic prediction of hepatotoxicity in [hepatocellular carcinoma] patients undergoing radioembolization of the whole liver,” as written by Watanabe et al. (1), nor in the prediction of response (4). Therefore, the achievement by Watanabe et al. might be regarded as an important step forward not only in dosimetric planning in radioembolization but also in nuclear medicine dosimetry in general, as one of the first evidences of superiority of voxel dosimetry over the mean-dose approach.

However, as often happens in science, opening new scenarios raises additional questions and the need for further clarification. We think that the nuclear medicine community would appreciate some general clarification to properly compare results to progress as a community. Some additional notes by Watanabe et al. would be welcome, since the rather simplified design of their study might have led to improvable safety thresholds.

Let us focus first on the whole-liver treatment subgroup of 98 patients, in which Watanabe et al. obtained a brilliant area under the curve (AUC) of 0.84 with a 40-Gy volume (V40) variable in terms of separation between toxic and nontoxic treatments. Then, with a standard methodology in the receiver-operating-characteristic curve analysis (Youden index), they found the best toxicity threshold at a 40-Gy volume of 72%. In their dose volume histogram, the 40-Gy volume variable is the percent volume of whole nontumoral liver tissue receiving an absorbed dose higher than 40 Gy. The obtained threshold means that if this percentage is larger than 72%, there is a certain risk of liver decompensation. The other limit of an absorbed dose to 30% of volume (AD30) means that we have risk if 30% of the nontumoral liver volume receives an absorbed dose of at least 43 Gy (AUC, 0.823). Using the mean absorbed dose on whole nontumoral liver tissue (AD-WNTLT), they obtained an apparently less brilliant AUC value of 0.633, with a safety threshold of 55.6 Gy.

Watanabe et al., however, did not report the uncertainty nor the 95% CI of the AUC values. Without this error estimate, it is impossible to demonstrate the significance of differences between different AUC values. Their mean AD-WNTLT can be compared with our finding, in contrast to the 40-Gy volume and 30% absorbed dose, which were not calculated in our work (5). The result, 55.6 Gy, is quite close to our 59 Gy, and the authors’ AUC of 0.633 is not so different from our AUC of 0.68.

Neither sensitivity nor specificity associated with such thresholds was mentioned.

The toxicity endpoint definition was different from our definition. We included other symptoms as indicators of liver decompensation: a prothrombin time international normalized ratio greater than 2.2, clinically detectable ascites, encephalopathy, esophageal varices bleeding, and death. The timeline was the same (≤6 mo).

All our patients were Child–Pugh A, whereas Watanabe et al.’s Table 1 reports that 109 patients were Child–Pugh A, 6 were Child–Pugh B7, and the remaining 61 were undefined. Should these patients be Child–Pugh C? This could explain toxicity at low AD-WNTLT.

We treated 96% of our patients with the lobar approach, and we extrapolated the tolerance to a whole-liver approach according to the Lyman formalism for a pure parallel organ. In our analysis, we censored patients on the day of the second treatment, in order to observe the effect and to calculate the dose for a single administration. Watanabe et al. obtained their best results in the group whose whole liver was treated, but “in cases of whole-liver treatment with 2 or more injections (e.g., separate injections for left and right lobes), injections were performed in 2 sessions, approximately 4–6 wk apart” (1). This whole-liver approach is therefore a sort of hybrid between a real simultaneous whole-liver treatment and 2 sequential right lobe–left lobe treatments, separated by a time interval insufficient to fully obtain radioinduced contralateral hypertrophy (5.9 ± 3.4 mo (6)). The dosimetric tolerance calculation is biased by this interval because we cannot rigorously consider the treatment as a single one, nor could we assume to have a new organ, as we assume once contralateral hypertrophy is completed. When considering these 2 models, one would choose the former because a time frame of 4–6 wk is short compared with 5.9 mo. Therefore, these 2-step treatments could (hardly) be considered as whole-liver treatments.

Watanabe et al. did not apply any analysis of the cause of toxicity introduced by Garin et al. (7). This aspect is important. In a hepatocellular carcinoma patient, liver decompensation happens, even without treatment, as a natural progression of cirrhosis or tumor growth. Furthermore, hyperbilirubinemia could derive from bile-duct compression by the tumor. Without a cause analysis, the authors included as toxicity cases those not derived from treatment. These events are observed even at a low absorbed dose. For this reason, the optimal threshold determination is impaired. Confirmation is provided by the normal-tissue complication probability experimental points reported by Strigari et al. (8). They also did not apply analysis of toxicity causes. Their point at the lowest biologic effective liver dose (20 Gy, corresponding to a 16-Gy whole-liver–absorbed dose) gave about a 20% risk of toxicity of at least grade 2 according to Common Terminology Criteria for Adverse Events (version 4; National Cancer Institute). In our experience (5), almost half of the observed liver decompensations within 6 mo were not related to treatment.

The second important aspect is that Watanabe et al. did not stratify patients on the basal bilirubin level. This risk factor is stronger than with AD-WNTLT (5) and heavily influences the safety threshold obtained. In Table 1, Watanabe et al. report a baseline bilirubin distribution of 0.8 ± 0.4 mg/dL. This means that, within 1 SD, 68% of the bilirubin level was within the interval of 0.4 and 1.2 mg/dL, whereas 32% are outside such an interval, with a nonnegligible percentage above 1.2 mg/dL (16% if the distribution was normal, that is, symmetric). In our steps toward optimal planning criteria, we started with a safety limit of 75 Gy (9), but after advances in knowledge, we were forced to split this limit into 50 Gy versus 90 Gy after we observed the importance of basal bilirubin levels greater than or less than 1.1 mg/dL, respectively (5).

The normal-tissue complication probability analysis is absent. This is the standard in external-beam radiobiologic modeling. Once the normal-tissue complication probability curve is obtained, it is possible to predict the quantitative level of risk of liver decompensation given an intended AD-WNTLT value. We decided to fix the limits to keep the liver decompensation risk lower than 15%. Just to clarify the difference, our receiver-operating-characteristic curve analysis with this bilirubin stratification gave optimal thresholds of 59 and 65 Gy, whereas the normal-tissue complication probability–based limits are 50 and 90 Gy.

In the lobar treatment group, Watanabe et al. reported 4 of 78 toxicity cases (5%) and 74 nontoxic cases. In the whole-liver approach, they had 16 of 98 liver decompensations (16%) versus 82 nontoxic treatments. Note that the difference in toxicity incidence was found to be significant using the exact Fisher test (P = 0.03). The mean AD-WNTLT was 42 Gy in the lobar treatment group (lower than our more conservative limit of 50 Gy), whereas it was 70 Gy in the whole-liver group. In addition, without a second contralateral treatment, radioinduced hypertrophy was free to develop. Therefore, the combination of lower AD-WNTLT and partial treatment resulted in a significantly lower toxicity incidence in the lobar approach. It was so low that the authors could not obtain statistical significance, nor was a meaningful threshold found, given the small number of toxic treatments, as was our experience with lobar treatment (4).

In conclusion, the voxel dosimetry method by Watanabe et al. might be an important advance to safely plan radioembolization. However, before being used in clinics by other centers, the proposed safety thresholds for whole-liver treatment (hybrid) should be revised according to the above comments, mainly introducing analysis of causes, stratification on the basal bilirubin value, and normal-tissue complication probability analysis.

DISCLOSURE

In the last 3 y, Carlo Chiesa and Marco Maccauro were consultants for Boston Scientific, the producer of 90Y glass microspheres; for Terumo, the producer of 166Ho microspheres; and for AAA, the producer of Lutathera (177Lu-DOTATATE). He received a research grant from Boston Scientific. Matteo Bagnalasta is a resident supported by a scholarship from Boston Scientific. No potential conflict of interest relevant to this article was reported.

Carlo Chiesa*, Matteo Bagnalasta, Marco Maccauro

*Foundation IRCCS Istituto Nazionale Tumori Milan, Italy

E-mail: carlo.chiesa{at}istitutotumori.mi.it

Footnotes

  • Published online Nov. 9, 2023.

  • © 2024 by the Society of Nuclear Medicine and Molecular Imaging.

REFERENCES

  1. 1.↵
    1. Watanabe M,
    2. Grafe H,
    3. Theysohn J,
    4. et al
    . Voxel-based dosimetry predicts hepatotoxicity in hepatocellular carcinoma patients undergoing radioembolization with 90Y glass microspheres. J Nucl Med. 2023;64:1102–1108.
    OpenUrlAbstract/FREE Full Text
  2. 2.↵
    1. Chiesa C,
    2. Bardies M,
    3. Zaidi H
    . Voxel-based dosimetry is superior to mean-absorbed dose approach for establishing dose–effect relationship in targeted radionuclide therapy. Med Phys. 2019;46:5403–5406.
    OpenUrl
  3. 3.↵
    1. Chiesa C,
    2. Mira M,
    3. Maccauro M,
    4. et al
    . Radioembolization of hepatocarcinoma with 90Y glass microspheres: development of an individualized treatment planning strategy based on dosimetry and radiobiology. Eur J Nucl Med Mol Imaging. 2015;42:1718–1738.
    OpenUrl
  4. 4.↵
    1. Romanò C,
    2. Mazzaglia S,
    3. Maccauro M,
    4. et al
    . Radioembolization of hepatocellular carcinoma with 90Y glass microspheres: no advantage of voxel dosimetry with respect to mean dose in dose–response analysis with two radiological methods. Cancers (Basel). 2022;14:959.
    OpenUrl
  5. 5.↵
    1. Chiesa C,
    2. Mira M,
    3. Bhoori S,
    4. et al
    . Radioembolization of hepatocarcinoma with 90Y glass microspheres: treatment optimization using the dose–toxicity relationship. Eur J Nucl Med Mol Imaging. 2020;47:3018–3032.
    OpenUrl
  6. 6.↵
    1. Palard X,
    2. Edeline J,
    3. Rolland Y,
    4. et al
    . Dosimetric parameters predicting contralateral liver hypertrophy after unilobar radioembolization of hepatocellular carcinoma. Eur J Nucl Med Mol Imaging. 2018;45:392–401.
    OpenUrl
  7. 7.↵
    1. Garin E,
    2. Rolland Y,
    3. Laffont S,
    4. Edeline J
    . Clinical impact of 99mTc-MAA SPECT/CT-based dosimetry in the radioembolization of liver malignancies with 90Y-loaded microspheres. Eur J Nucl Med Mol Imaging. 2016;43:559–575.
    OpenUrlCrossRefPubMed
  8. 8.↵
    1. Strigari L,
    2. Sciuto R,
    3. Rea S,
    4. et al
    . Efficacy and toxicity related to treatment of hepatocellular carcinoma with 90Y SIR spheres: radiobiologic considerations. J Nucl Med. 2010;51:1377–1385.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    1. Chiesa C,
    2. Mira M,
    3. Maccauro M,
    4. et al
    . A dosimetric treatment planning strategy in radioembolization of hepatocarcinoma with 90Y glass microspheres. Q J Nucl Med Mol Imaging. 2012;56:503–508.
    OpenUrlPubMed
  • Revision received August 4, 2023.
  • Accepted for publication August 22, 2023.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 65 (2)
Journal of Nuclear Medicine
Vol. 65, Issue 2
February 1, 2024
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Good Voxel Dosimetry with a Simplified Study Design Resulted in Improvable Safety Limits
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Good Voxel Dosimetry with a Simplified Study Design Resulted in Improvable Safety Limits
Carlo Chiesa, Matteo Bagnalasta, Marco Maccauro
Journal of Nuclear Medicine Feb 2024, 65 (2) 331-332; DOI: 10.2967/jnumed.113.129353

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Good Voxel Dosimetry with a Simplified Study Design Resulted in Improvable Safety Limits
Carlo Chiesa, Matteo Bagnalasta, Marco Maccauro
Journal of Nuclear Medicine Feb 2024, 65 (2) 331-332; DOI: 10.2967/jnumed.113.129353
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Reply to “The Value of Functional PET in Quantifying Neurotransmitter Dynamics”
  • Reply to “The Randomized, Phase 2 LuCAP Study”
  • Maintaining the Evidence for In Vivo Brain Estrogen Receptor Density by Neuroendocrine Aging and Relationships with Cognition and Symptomatology
Show more Letter to the Editor

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire