Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportPhysics, Instrumentation & Data Sciences - Data Analysis & Management

Using a computationally consistent and efficient graphic analysis of 18F-PBR06 total-body dynamic PET in health volunteers

Bolun Li, Song Ding, Zhiguo Zou, Ningchao Wang, Yumei Chen, Yun Zhou, Yihan Wang, Jianjun Liu and Jun Pu
Journal of Nuclear Medicine June 2023, 64 (supplement 1) P902;
Bolun Li
1United Imaging Healthcare Group Co., Ltd
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Song Ding
2Department of Cardiology, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200217, China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Zhiguo Zou
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ningchao Wang
3Central Research Institute, United Imaging Healthcare Group Co., Ltd, Shanghai, 201807, China.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yumei Chen
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yun Zhou
4United Imaging Healthcare Co., Ltd
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yihan Wang
4United Imaging Healthcare Co., Ltd
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jianjun Liu
5Department of Nuclear Medicine, Ren Ji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jun Pu
6Department of Cardiology, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai 200217, China.
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

P902

Introduction: 18F-PBR06 PET was recently proposed for translocator protein 18-kDa (TSPO) imaging, but lack of knowledge of 18F-PBR06 kinetics measured by human dynamic PET. Kinetic modeling and parametric imaging of human 18F-PBR06 total-body dynamic PET is even challenging in terms of high heterogeneity in tracer kinetics and computational cost. In quantitative radioligand-receptor PET analyses, the graphical analysis including the Logan plot and the relative equilibrium based graphical plot (RE plot) are used to estimate total distribution volume (VT). Previous studies show that the Logan plot in VT estimation is robust to tracer kinetics but sensitive to the noisy levels of data. In contrast, the RE plot is computationally efficient and consistent in VT estimation, but its application is limited to the condition of relative equilibrium of tracer kinetics. The objective of this study is to evaluate the Logan and RE plots for quantification of 18F-PBR06 total-body dynamic PET in the healthy volunteers.

Methods: A total of 6 healthy human volunteers were enrolled in this study. All participants underwent a 90-min dynamic 18F-PBR06 PET scan on a high sensitivity and high resolution total-body PET/CT scanner (uEXPLORER, united-Imaging Healthcare). The PET images were reconstructed into a total of 98 dynamic frames (30×2 s, 12×5 s, 6×10 s, 4×30 s, 25×60 s, 15×120 s, 6×300 s) with an image matrix of 360×360 pixel, 4 iterations, and 20 subsets by list-mode ordered subset-expectation maximization (OSEM) algorithm with time-of-flight and point-spread function (PSF). Six regions of interest (ROI) were drawn manually using PMOD, including descending aorta, kidney, spleen, liver, lung, left ventricle wall (LV_wall). The time activity curve (TAC) of the descending aorta ROI was used as input function for the Logan and RE plots. Brain PET was spatially normalized standard space and 35 brain ROIs were drawn on a MRI template in standard space to extract brain ROI TACs. The distribution volume (VT) was estimated by using RE plot and Logan plot with blood input function for each ROI with t*=20-min. The VT parametric images were also generated from both RE plot and Logan plot.

Results: The spatial distribution and kinetics of 18F-PBR06 measured by total-body PET is demonstrated in Fig. a. The graphical analysis of Logan plot and RE plot at ROI TAC level from a typical study is shown in Fig. b-e. The VT estimates obtained by linear regression slope from the study are quite comparable. As shown in Fig.f and Fig.j, the VT estimates from the ROI TACs with the RE plot are close to the ones from the ROI TAC with Logan plot. High to low VTs were observed in LV_wall, spleen, kidney, liver, lung, and brain. VT in thalamus is highest in the brain ROIs. Parametric images of VT generated from a typical study using the Logan plot and RE plot were shown in Fig. h. Compared the RE plot, the noise-induced under estimation in the VT images generated by the Logan plot was observed (arrowed) in the typical study.

Conclusions: In conclusion, this is a first-in-human kinetic modeling and parametric imaging of 18F-PBR06 total-body dynamic PET in healthy participants. The parameter VTs from RE plot and Logan plot kinetic modeling were comparable at ROI kinetic level. The computationally consistent and efficient graphic analysis using RE plot is suggested for VT parametric image generation.

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 64, Issue supplement 1
June 1, 2023
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Using a computationally consistent and efficient graphic analysis of 18F-PBR06 total-body dynamic PET in health volunteers
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Using a computationally consistent and efficient graphic analysis of 18F-PBR06 total-body dynamic PET in health volunteers
Bolun Li, Song Ding, Zhiguo Zou, Ningchao Wang, Yumei Chen, Yun Zhou, Yihan Wang, Jianjun Liu, Jun Pu
Journal of Nuclear Medicine Jun 2023, 64 (supplement 1) P902;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Using a computationally consistent and efficient graphic analysis of 18F-PBR06 total-body dynamic PET in health volunteers
Bolun Li, Song Ding, Zhiguo Zou, Ningchao Wang, Yumei Chen, Yun Zhou, Yihan Wang, Jianjun Liu, Jun Pu
Journal of Nuclear Medicine Jun 2023, 64 (supplement 1) P902;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Validation of the lesion quantification of a learning-based PET image filter
  • Advanced Delay Correction Using TAC Integration and Newton-Raphson Method in Dynamic PET Imaging
  • An Automatic Segmentation and Classification Method for Lung Cancer with Visceral Pleural Invasion Based on PET/CT Deep Learning and Radiomics
Show more Physics, Instrumentation & Data Sciences - Data Analysis & Management

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire