Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportImage Generation

Iterative PET Reconstruction Algorithms followed by Non-Local Means Denoising for Improved Quantitative Imaging

Luke Polson, Carlos Uribe and Arman Rahmim
Journal of Nuclear Medicine August 2022, 63 (supplement 2) 3297;
Luke Polson
1BC Cancer
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Carlos Uribe
1BC Cancer
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Arman Rahmim
2University of British Columbia
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

3297

Introduction: To test the use of non-local means (NLM) as a method to improve the quantitative performance of various iterative PET reconstruction algorithms using a python-based framework.

Methods: Realistic simulated PET images were generated from first principles using radiopharmaceutical maps coupled to attenuation maps. We specifically focused on modeling of three distinct regions: lesions, liver, and background. Noise was modeled by generating a total number of decays from each pixel that followed a Poisson distribution with mean proportional to the true radiopharmaceutical concentration. To account for attenuation, sinograms were generated using only detected coincidence events.

To obtain quantitative images that provide an estimate of the radiopharmaceutical, attenuation effects present in the sinogram were removed through normalization by a probability map (obtained through a corresponding attenuation map). Sinograms were then used as input for a variety of iterative PET image reconstruction algorithms from the python library TomoPy. Methods included the analytical reconstruction technique (ART), the simultaneous iterative reconstructive technique (SIRT), the total variation reconstruction technique (TV), and variations of maximum-likelihood expectation maximum (MLEM) and ordered-subset expectation maximum (OSEM), including those with linear and quadratic penalty terms. With increasing iterations, noise-bias trade-off curves were generated for different algorithms, enabling comparison between different methods. The results for the different reconstruction algorithms were compared with increasing iterations using noise-bias trade-off curves.

An NLM framework for denoising was applied to generate images at each stage of the iterative process, yielding updated noise-bias trade-off curves. The purpose of such modification was to (i) compare the relative improvements across algorithms, and (ii) compare relative improvements between the background, liver, and lesions of each image.

Results: Analysis of noise-bias curves suggests that NLM improves the reconstructive capabilities of all iterative algorithms considered in the background and liver regions. All algorithms saw a reduction in both bias and noise in the background region: the most significant examples were ART with an average reduction in noise from 43.4% to 27.8% and OSEM with an average reduction in bias from 5.36% to 3.82% throughout their iterations. For liver, all algorithms saw a decrease in noise with a slight increase in bias: the most significant examples were OSEM with an average decrease in noise from 17.68% to 10.26%. For tumor regions, the ART, MLEM, OSEM, SIRT, and TV algorithms all saw reductions in noise, while variations of MLEM and OSEM with penalized linear and quadratic components saw an increase. Figures show reconstructed images using all algorithms without and with NLM, noise-bias trade-off curves for all algorithms, and sample curves comparing standard and NLM adjustments.

Conclusions: For the realistically simulated dataset studied, use of a NLM denoising framework on predicted PET images reconstructed with iterative reconstruction algorithms was shown to improve quantitative performance. While the results are most notable in background and liver regions, improvements in tumor regions are also observed for certain algorithms.

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 63, Issue supplement 2
August 1, 2022
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Iterative PET Reconstruction Algorithms followed by Non-Local Means Denoising for Improved Quantitative Imaging
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Iterative PET Reconstruction Algorithms followed by Non-Local Means Denoising for Improved Quantitative Imaging
Luke Polson, Carlos Uribe, Arman Rahmim
Journal of Nuclear Medicine Aug 2022, 63 (supplement 2) 3297;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Iterative PET Reconstruction Algorithms followed by Non-Local Means Denoising for Improved Quantitative Imaging
Luke Polson, Carlos Uribe, Arman Rahmim
Journal of Nuclear Medicine Aug 2022, 63 (supplement 2) 3297;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Positron Range Correction Improves Rubidium-82 PET Myocardial Perfusion Image Quality
  • SubtlePET Analysis Using American College of Radiology Phantom and Guidelines
  • Unsupervised deep learning strategies for noise reduction in 18F-FDG brain PET imaging
Show more Image Generation