Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportPoster - Technologist

The impact of acquisition time on quantitative bone single photon emission computed tomography using the SwiftScan technique

Yuya Sekikawa, Takuro Shiiba, Shinji Tateoka, Nobutaka Shinohara, Yuuki Inoue, Yasuyoshi Kuroiwa, Takashi Tanaka, Yasushi Kihara and Takuroh Imamura
Journal of Nuclear Medicine May 2021, 62 (supplement 1) 3030;
Yuya Sekikawa
1Department of Radiological Technology, Faculty of Fukuoka Medical Technology Teikyo Univerisity Fukuoka Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Takuro Shiiba
1Department of Radiological Technology, Faculty of Fukuoka Medical Technology Teikyo Univerisity Fukuoka Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Shinji Tateoka
2Department of Radiological Technology Koga General Hospital Miyazaki Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Nobutaka Shinohara
2Department of Radiological Technology Koga General Hospital Miyazaki Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yuuki Inoue
2Department of Radiological Technology Koga General Hospital Miyazaki Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yasuyoshi Kuroiwa
2Department of Radiological Technology Koga General Hospital Miyazaki Japan
3Department of Pathology, Faculty of Medicine University of Miyazaki Miyazaki Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Takashi Tanaka
4Department of Radiology Koga General Hospital Miyazaki Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yasushi Kihara
4Department of Radiology Koga General Hospital Miyazaki Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Takuroh Imamura
5Department of Internal Medicine Koga General Hospital Miyazaki Japan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

3030

Objectives: Recently, the SwiftScan technique was released by GE Healthcare and has been used in clinical settings. In single photon emission computed tomography (SPECT), the SwiftScan mode enhances sensitivity, allowing data acquisitions during heads rotation. In previous studies, performance of the SwiftScan has been evaluated; however, the effect of the acquisition time for quantitative bone SPECT using SwiftScan has not been fully understood yet. Thus, this study aimed to clarify the effect of the acquisition time on the quantitative value of bone SPECT using the SwiftScan technique.Methods: Phantom SPECT image acquisition was performed on a Discovery NM/CT 860 (GE Healthcare) with a low-energy high-resolution and sensitivity collimator. Main and sub energy window acquisitions were 140 keV ± 10% and 120 keV ± 5%, respectively. The phantom was a SIM2 Bone Phantom (Kyoto Kagaku). The diameters of the spheres installed in the phantom were 13, 17, 22, 28, and 35 mm. The background was assumed normal area while the sphere was assumed vertebra tumor area. The radioactivity concentration of the background and hot sphere were 50 kBq/mL and 300 MBq/mL, respectively. Each SPECT acquisition time was 6, 10, 30, and 60 s per projection. All acquired images were reconstructed using a three-dimensional iterative ordered subsets expectation maximization algorithm with attenuation correction, scatter correction, and resolution recovery (10 iterations, 4 subsets, no post-filter, matrix size of 128 × 128, and pixel size of 4.42 × 4.42 mm). The relative error between the theoretical and measured standardized uptake value (SUV) was calculated, and the sums of the relative errors of all the spheres at each acquisition time were compared.

Results: In the 35-mm reference part, relative errors between theoretical and measured SUVs were 50.6%, 28.9%, 11.6%, and 6.6% in 6, 10, 30, and 60 s per projection of the acquisition time, respectively. Similarly, in the 28-mm sphere, the relative errors were 35.2%, 21.2%, 3.3%, and 9.6%; 22-mm sphere, 46.8%, 24.0%, 9.5%, and 0.1%; 17-mm sphere, 30.2%, 14.3%, 19.2%, and 23.6%; and 13-mm sphere, 6.5%, 10.5%, 37.4%, and 35.7%. The sum of the relative errors in each sphere size were 169.4%, 98.9%, 81.1%, and 75.7% in 6, 10, 30, and 60 s per projection of the acquisition time, respectively. As the acquisition time was shorter, the relative error of SUV was larger.

Conclusions: This study investigated the impact of acquisition time on quantitative bone SPECT using the SwiftScan technique. Our results suggest that the SwiftScan cannot obtain an accurate SUV with a short acquisition time. Therefore, it is recommended to use longer acquisition times of at least 30 s per projection for quantitative bone SPECT to stabilize the SUV. The use of an optimal acquisition time would improve bone metastases diagnostic performance.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 62, Issue supplement 1
May 1, 2021
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The impact of acquisition time on quantitative bone single photon emission computed tomography using the SwiftScan technique
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
The impact of acquisition time on quantitative bone single photon emission computed tomography using the SwiftScan technique
Yuya Sekikawa, Takuro Shiiba, Shinji Tateoka, Nobutaka Shinohara, Yuuki Inoue, Yasuyoshi Kuroiwa, Takashi Tanaka, Yasushi Kihara, Takuroh Imamura
Journal of Nuclear Medicine May 2021, 62 (supplement 1) 3030;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
The impact of acquisition time on quantitative bone single photon emission computed tomography using the SwiftScan technique
Yuya Sekikawa, Takuro Shiiba, Shinji Tateoka, Nobutaka Shinohara, Yuuki Inoue, Yasuyoshi Kuroiwa, Takashi Tanaka, Yasushi Kihara, Takuroh Imamura
Journal of Nuclear Medicine May 2021, 62 (supplement 1) 3030;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Poster - Technologist

  • Development of high resolution modular four side buttable small field of view detectors for three dimensional gamma imaging
  • Impact of different PET reconstruction algorithms on18F FDG SUV and MTV of tumor lesions
Show more Poster - Technologist

Technologist Poster Session

  • Development of high resolution modular four side buttable small field of view detectors for three dimensional gamma imaging
  • Impact of different PET reconstruction algorithms on18F FDG SUV and MTV of tumor lesions
  • Variation in Delivery Methods of 18F-FDG for Patients: A Single Institution Observation.
Show more Technologist Poster Session

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire