Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportPoster - PhysicianPharm

Using LSO background radiation for CT-less attenuation correction of PET data in long axial FOV PET scanners

Mohammadreza Teimoorisichani, Hasan Sari, Vladimir Panin, Deepak Bharkhada, Axel Rominger and Maurizio Conti
Journal of Nuclear Medicine May 2021, 62 (supplement 1) 1530;
Mohammadreza Teimoorisichani
1Siemens Medical Solutions USA, Inc Knoxville TN United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hasan Sari
2Advanced Clinical Imaging Technology, Siemens Healthcare AG Lausanne Switzerland
3Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern Bern Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Vladimir Panin
1Siemens Medical Solutions USA, Inc Knoxville TN United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Deepak Bharkhada
1Siemens Medical Solutions USA, Inc Knoxville TN United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Axel Rominger
3Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern Bern Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Maurizio Conti
1Siemens Medical Solutions USA, Inc Knoxville TN United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

1530

Objectives: The present generation of PET scanners use lutetium-based scintillators due to their short decay time, high density, and high luminosity. The radioisotope 176Lu in these scintillators provides intrinsic background radiation that can be used to measure attenuation without an additional dose from CT. This is of particular interest in view of the recent introduction of long axial FOV scanners, which are suitable for extremely low dose PET for pediatric imaging, repeated scans, PET screening, and more. Moreover, due to the larger number of detectors, the rate of such background events in an extended axial FOV scanner is far greater than that of conventional PET scanners. In this study, a novel CT-less PET image reconstruction framework using LSO background transmission (LSO-TX) data is discussed and evaluated on clinical PET/CT scanners.

Methods: The Biograph Vision and Biograph Vision Quadra (Siemens Healthineers) PET/CT scanners were used in this work. The Biograph Vision and Vision Quadra have, respectively, 8 and 32 detector rings providing an axial coverage of 26 and 106 cm in a single FOV. Detectors of both scanners comprise LSO crystals with an estimated 176Lu activity of 240 Bq/cm3. With a wide-open energy window, a detector singles rate of about 11 kcps is recorded due to the LSO intrinsic activity. In a 176Lu decay, a β decay with a Q value of 597 keV followed by a cascade of γ photons at 307 and 202 keV occurs. To capture the 202 and 307 keV γ photons of LSO TX, the energy and coincidence timing window were wide open. While the β triggers the constant fraction discriminator, the γ photon records a coincidence. From the list of recorded events, the LSO-TX at 202 and 307 keV were extracted and histogrammed to create transmission sinograms, and μ-maps were reconstructed using a maximum likelihood for transmission tomography (MLTR) algorithm. The μ-maps from LSO-TX suffer from noise and often have a low signal-to-noise ratio (SNR). Therefore, a convolutional neural network (CNN) based image denoising method was employed. U-Net architecture with residual units was used to denoise LSO-TX images. 2D axial images of LSO-TX-derived μ-maps were used as input data. The image volumes were normalized to zero mean and unity variance. The network was trained on 9 various phantom datasets acquired using Biograph Vision and Biograph Vision Quadra. The resulting μ-maps were fed into a TOF-MLAA algorithm in which activity and attenuation images were sequentially updated using, respectively, the TOF-MLEM and MLTR algorithms. The extremely good time resolution of the two scanners allows for optimal performance of TOF-MLAA.

Results: Several experiments were performed to develop and validate the method in both Biograph Vision and Biograph Vision Quadra. In this summary, MLAA images of a NEMA NU-2 image quality phantom with a total of 15 MBq 68Ge acquired on Biograph Vision are shown. Also, an example of LSO TX-derived μ-map is shown for a human subject, as acquired on the Biograph Vision and Biograph Vision Quadra. Other phantom and patient images from the Vision Quadra will be shown in the final presentation. LSO-TX-derived μ-maps with and without CNN-based denoising are shown in figure 1 for the image quality phantom. Compared to CT-derived μ-map, mean absolute error of initial LSO TX μ-maps was reduced from 0.028 cm-1 to 0.016 cm-1 when CNN-based denoising is applied.

Conclusions: PET images reconstructed from the TOF MLAA algorithm initialized with denoised LSO TX μ-maps, and TOF MLEM algorithm using CT-based μ-maps suggest that the TOF MLAA reconstruction framework can be a reliable and suitable solution to CT-less PET imaging, in particular for long axial FOV PET scanners.

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 62, Issue supplement 1
May 1, 2021
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Using LSO background radiation for CT-less attenuation correction of PET data in long axial FOV PET scanners
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Using LSO background radiation for CT-less attenuation correction of PET data in long axial FOV PET scanners
Mohammadreza Teimoorisichani, Hasan Sari, Vladimir Panin, Deepak Bharkhada, Axel Rominger, Maurizio Conti
Journal of Nuclear Medicine May 2021, 62 (supplement 1) 1530;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Using LSO background radiation for CT-less attenuation correction of PET data in long axial FOV PET scanners
Mohammadreza Teimoorisichani, Hasan Sari, Vladimir Panin, Deepak Bharkhada, Axel Rominger, Maurizio Conti
Journal of Nuclear Medicine May 2021, 62 (supplement 1) 1530;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Poster - PhysicianPharm

  • Preliminary result of Texture Analysis on prediction of overall outcome of neuroendocrine tumors based on pre-therapy heterogeneity of somatostatin receptors on 68Ga Dotatate PET/CT scans.
  • The Effect of BMI on High versus Low Administered Activity Protocol MPI Scan Time Using a CZT Camera in Clinical Practice
  • The Role of 18F-FDG-PET/CT Imaging in Predicting Outcome of Patients with Newly Diagnosed Multiple Myeloma
Show more Poster - PhysicianPharm

PIDS Image Generation

  • Clinical Use of Siemens VG80 Deviceless Gating and Comparison to Standard Belt-Based Techniques
  • Denoising PET via non-local means with entropy-based regulation.
  • Clinical evaluation on image quality of a deep learning-based denoising algorithm in 18F-FDG PET/CT studies
Show more PIDS Image Generation

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire