Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportPoster - PhysicianPharm

Quantitative Evaluation of three Siemens Biograph PET scanners using different reconstruction algorithms and parameters.

Mahdjoub Hamdi, Syahir Mansor and Richard Laforest
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 1503;
Mahdjoub Hamdi
1Washington University School of Medicine Saint Louis MO United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Syahir Mansor
2Washington University School of Medicine St. Louis MO United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Richard Laforest
3Washington University Saint Louis MO United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

1503

Purpose: Our department is equipped with 3 PET/CT scanners of different generations and in order to match the resolution and noise properties of these scanners, this study compared their performance using different reconstruction algorithms and parameters, evaluated count recovery and noise, and determined image reconstruction parameters leading to harmonized quantitative imaging performance among all the three scanners.

Methods: The NEMA-IEC image quality phantom with the standard 6 spheres (10 to 37 mm) and a second set of 6 smaller spheres (4-12mm) were filled with 9.35:1 lesion to background ratio. Measurements were first conducted with the Siemens Vision PET/CT, the Biograph mMR PET/MR and the Biograph 40 PET/CT. Data were acquired in list-mode format, for the Vision PET/CT images were generated at 1 and 5 minutes frame duration. For the successive measurements, due to the radioactive decay, this time frames were extended have a match in the activity for all three scanners: time frames were extended to 1.23 and 6.33 minutes for the B40, and to 1.62 and 8.42 minutes on mMR. Images were reconstructed using 3D-ordered subset expectation Maximization (3D-OSEM) algorithm with and without including point spread function (PSF). Time of flight (TOF) was employed on the Biograph Vision. The number of iterations were varied from 4-8 on the Vision, and from 2-5 on the B40 and the mMR. Images were reconstructed with a range of 0-5 mm Gaussian post-reconstruction smoothing filter. The contrast recovery coefficients (CRC - ratio of mean measured activity within a sphere over the expected activity) and coefficients of the variance (COV - standard deviation of the pixel intensity in a large VOI in a uniform section of the phantom divided by the mean value within this VOI) were used as metrics of count recovery and image noise for this study. Lesion detectability with the smallest set of spheres was conducted.

Results: Using the standard set of spheres, contrast recovery curves were created for each scanners and each image reconstruction parameter sets (filter and iteration number). The configuration of image reconstruction parameters that led to the most identical count recovery curve among the three scanners was determined from the sum squared difference minimized over all image reconstruction parameter set. This study indicated that image reconstruction performed with 4 iterations, with respectively 4, 0 and 5 mm post-reconstruction filter on the B40, mMR and Vision scanners (5min data) led to harmonized CRC curves (Fig1a). When using point-spread function, the best agreement was obtained at 4it/5mm on B40, 2it/0mm on mMR and 4it/4mm on the Vision with the Vision producing still higher CRC value for all spheres (Fig1b). Best agreement with the 1 minute of data (more noisy) was obtained with 5it/2mm on B40, 2it/0mm on mMR and 4it/5mm on the Vision. The CRC vs COV analysis indicated that PSF reconstruction leads to increased recovery without significant noise increase (Fig 2a, 2b). At matched activity, the COV in the Vision is overall lower (lower noise). Lesion detect ability indicated the Vision scanner was most superior to identify small lesions.

Conclusions: This study allowed to fully map the range of size-dependent CRC values from three PET/CT scanners in our department and to determine image reconstruction parameters that permit to obtain quantitatively comparable PET data from these three scanners. This study also demonstrate the improved performance of the Vision for identifying and quantifying small lesions.

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 61, Issue supplement 1
May 1, 2020
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Quantitative Evaluation of three Siemens Biograph PET scanners using different reconstruction algorithms and parameters.
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Quantitative Evaluation of three Siemens Biograph PET scanners using different reconstruction algorithms and parameters.
Mahdjoub Hamdi, Syahir Mansor, Richard Laforest
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 1503;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Quantitative Evaluation of three Siemens Biograph PET scanners using different reconstruction algorithms and parameters.
Mahdjoub Hamdi, Syahir Mansor, Richard Laforest
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 1503;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Poster - PhysicianPharm

  • Preliminary result of Texture Analysis on prediction of overall outcome of neuroendocrine tumors based on pre-therapy heterogeneity of somatostatin receptors on 68Ga Dotatate PET/CT scans.
  • High incidence of atherosclerosis in smokers demonstrated by NaF-PET/CT imaging of the major arteries
  • Incidental extracardiac findings from myocardial perfusion PET/CTs in a veteran population
Show more Poster - PhysicianPharm