Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportPhysics, Instrumentation & Data Sciences

PET Attenuation Correction Using MRI-aided Two-Stream Pyramid Attention Network

Xiaofeng Yang, Yang Lei, Tonghe Wang, Yabo Fu, Aparna Kesarwala, Tian Liu, Kristin Higgins, Walter Curran, Jonathon Nye and Hui Mao
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 110;
Xiaofeng Yang
1Emory University Atlanta GA United States
4Emory University Atlanta GA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yang Lei
2Emory university ATLANTA GA China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tonghe Wang
3Emory University Atlanta GA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yabo Fu
1Emory University Atlanta GA United States
4Emory University Atlanta GA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Aparna Kesarwala
1Emory University Atlanta GA United States
4Emory University Atlanta GA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tian Liu
1Emory University Atlanta GA United States
4Emory University Atlanta GA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kristin Higgins
1Emory University Atlanta GA United States
4Emory University Atlanta GA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Walter Curran
5Winship Cancer Institute of Emory University Atlanta GA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jonathon Nye
1Emory University Atlanta GA United States
4Emory University Atlanta GA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hui Mao
6Emory University School of Medicine Atlanta GA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

110

Objectives: Deriving accurate attenuation maps for PET/MRI remains a challenging problem because voxel-wised signal intensities from MRI are unrelated to photon attenuation. In addition, MRI has a poor signal from bone and often with image artifacts at bone/air interfaces. With the capability of simultaneous data acquisition from PET and MRI data, it is desirable to use structural MRI data from a clinical sequence to directly guide PET attenuation correction (AC). This work proposes a deep-learning-based method to use routine T1-weighted MRI to directly aid PET AC without the need for an attenuation coefficient map.

Methods: We propose a novel network architecture, called Two-Stream Pyramid Attention Network (TSPAN), which can utilize any structural MRI of a PET/MRI scan to aid direct AC PET estimation from non-AC (NAC) PET. The proposed network integrates a self-attention strategy into a pyramid network for deep salient feature extraction. CT-based AC PETs from the same subjects were used as the ground truth for network training. Two dedicated sub-networks with the same pyramid architecture design were used to process NAC PET and MRI, independently. The outputs of these two sub-networks were compared with the ground truth to calculate two independent loss terms which were the NAC-only loss and MRI-only loss. Since the feature maps obtained from these two sub-networks are complementary to each other, therefore, it is beneficial to combine them in a late fusion sub-network for final estimation. In the late fusion sub-network, the learned feature maps of each corresponding pyramid level were first concatenated and then highlighted by attention gates. The final loss was calculated by comparing the final PET estimation and the ground truth. Our network was trained using a 3D-patch-based method. In the testing stage, the final set of synthetic AC PET images was generated using patch-based prediction, followed by patch fusion. The trained network was tested on brain datasets from 21 patients using leave-one-out cross-validation. Standardized uptake value (SUV) differences between the MRI-aided AC PET estimation and the ground truth from the PET/CT of the same patients were quantitatively evaluated using metrics including mean absolute error (MAE) and mean error (ME), and normalized cross-correlation (NCC). Statistical analysis was performed to compare the differences between the MRI-aided AC PET estimation and the ground truth.

Results: The AC PET images generated using the proposed MRI-aided method show great resemblance to the reference PET/CT images. The average MAE, ME, and NCC between MRI-aided AC PET and CT-based AC PET images in the whole brain for all patients were 4.09±0.71% and -1.52±0.28%, and 0.958±0.032, respectively. The average ME ranged from -3.68% to 3.66% for all contoured volumes of interest. There was no significant difference between the MRI-aided AC PETs and the reference PET/CTs. Conclusion: We have demonstrated an MRI-aided PET AC method using a novel two-stream pyramid attention network. Our results showed that the proposed method was able to generate highly accurate AC PET estimations comparable to conventional PET/CT derived AC maps. This new approach leveraged simultaneously acquired MRI data in the PET/MRI scans with the superior MRI soft-tissue contrast to improve AC PET estimation with precise organ boundary definition. This technique could be used for accurate PET attenuation and partial volume correction in combined/integrated PET/MRI imaging applications.

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 61, Issue supplement 1
May 1, 2020
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
PET Attenuation Correction Using MRI-aided Two-Stream Pyramid Attention Network
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
PET Attenuation Correction Using MRI-aided Two-Stream Pyramid Attention Network
Xiaofeng Yang, Yang Lei, Tonghe Wang, Yabo Fu, Aparna Kesarwala, Tian Liu, Kristin Higgins, Walter Curran, Jonathon Nye, Hui Mao
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 110;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
PET Attenuation Correction Using MRI-aided Two-Stream Pyramid Attention Network
Xiaofeng Yang, Yang Lei, Tonghe Wang, Yabo Fu, Aparna Kesarwala, Tian Liu, Kristin Higgins, Walter Curran, Jonathon Nye, Hui Mao
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 110;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Physics, Instrumentation & Data Sciences

  • Clinical feasibility of quantitative holmium-166 SPECT in presence of technetium-99m colloid
  • 3D Structural Convolutional Sparse Coding for PET Image Reconstruction
  • Exploration of Multi-objective Optimization with Genetic Algorithms for PET Image Reconstruction
Show more Physics, Instrumentation & Data Sciences

Attenuation, Scatter and Resolution Compensation (PET & SPECT)

  • Clinical evaluation of Poisson maximum likelihood-based scatter subtraction for 68Ga-PSMA imaging
  • Data consistency conditions for attenuation map alignment in pinhole cardiac SPECT
Show more Attenuation, Scatter and Resolution Compensation (PET & SPECT)

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire