Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportPhysics, Instrumentation & Data Sciences

Deep learning generation of intermediate projections and Monte Carlo based reconstruction improves 177Lu SPECT images reconstructed with sparse acquired projections

Tobias Ryden, Ida Marin, Martijn van Essen, Johanna Svensson and Peter Bernhardt
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 44;
Tobias Ryden
2Radiation Physics Gothenburg University Gothenburg Sweden
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ida Marin
2Radiation Physics Gothenburg University Gothenburg Sweden
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Martijn van Essen
3Nuclear Medicine Sahlgrenska University Hospital Gothenburg Sweden
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Johanna Svensson
1Oncology Gothenburg University Gothenburg Sweden
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Peter Bernhardt
2Radiation Physics Gothenburg University Gothenburg Sweden
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

44

Objectives: The objective was to improve image quality of 177Lu-DOTATATE SPECT images reconstructed from sparse acquired projections by constructing a deep neural network for generation of additional projections. The impact of using Monte Carlo based reconstruction for further improvement of the image quality in sparse acquired projections will also be studied.

Methods: A deep neural network with a 3D U-net structure was constructed. The last layer consists of a rectified linear unit and a pixelwise L2 loss function was used for the stochastic gradient descent algorithm. The deep neural network construction and training was performed with Microsoft’s Cognitive Toolkit (CNTK) 2.6 in Python and the trained model was used in C++. The network was trained to generate the intermediate projections for a sparse set of 30 projections to the original 120 projections. 400 patient SPECT images acquired with 120 projections were used in the training. Every forth projection was used for input to the model and the others for the loss function.SPECT images for quality evaluation were reconstructed with the full 120 projections, 30 projections where every forth projection out of the 120 were used, and 120 projections where 90 were generated from the 30 projections using the trained artificial intelligence (AI) model (30-120 AI), i.e. the deep neural network described above. The SPECT images were reconstructed with a standard iterative reconstruction algorithm with attenuation correction (AC-OSEM) and a Monte Carlo based reconstruction algorithm (SARec-OSEM). Image quality was evaluated quantitatively in SPECT acquisitions of a Jaszczak phantom with 177Lu and visually in SPECT acquisitions of 177Lu-DOTATATE in 15 patients by an experienced nuclear medicine physician.

Results: The phantom images showed that the recovery was slightly decreased but the signal to noise ratio (SNR) was greatly improved by adding the deep learning generated projections to the sparse acquired projections. All SARec-OSEM reconstructions were superior to AC-OSEM. No artefacts such as corelated noise, which are normally introduced when bicubic interpolation of projections are applied, could be detected. The nuclear medicine physician ranked the SARec-OSEM 120 or SARec-OSEM 30-120 AI patient images as showing the best overall quality. The reconstructed patient SPECT images with only 30 projections were evaluated to have too high noise level.

Conclusions: Our study showed that using AI to generate intermediate projections from sparsely sampled SPECT increase the SNR with limited loss in recovery. The AI generator showed improved overall image quality and has the potential to reduce the number of acquired SPECT projections. Furthermore, our in house developed Monte Carlo based reconstruction algorithm SARec-OSEM showed improved image quality in both the quantitative phantom measurements and in the patients. By using both deep learning generated projections and SARec reconstruction, it seems possible to reduce the number of projections substantially, thereby enabling an acquisition reduction by a factor of 2-4 for 177Lu-DOTATATE SPECT images.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 60, Issue supplement 1
May 1, 2019
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Deep learning generation of intermediate projections and Monte Carlo based reconstruction improves 177Lu SPECT images reconstructed with sparse acquired projections
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Deep learning generation of intermediate projections and Monte Carlo based reconstruction improves 177Lu SPECT images reconstructed with sparse acquired projections
Tobias Ryden, Ida Marin, Martijn van Essen, Johanna Svensson, Peter Bernhardt
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 44;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Deep learning generation of intermediate projections and Monte Carlo based reconstruction improves 177Lu SPECT images reconstructed with sparse acquired projections
Tobias Ryden, Ida Marin, Martijn van Essen, Johanna Svensson, Peter Bernhardt
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 44;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Physics, Instrumentation & Data Sciences

  • Clinical feasibility of quantitative holmium-166 SPECT in presence of technetium-99m colloid
  • 3D Structural Convolutional Sparse Coding for PET Image Reconstruction
  • Exploration of Multi-objective Optimization with Genetic Algorithms for PET Image Reconstruction
Show more Physics, Instrumentation & Data Sciences