Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportPhysics, Instrumentation & Data Sciences

Predictive model for a Rb-82 generator bolus times as a function of generator lifetime

Alexander Scott and Mark Hyun
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 386;
Alexander Scott
2Imaging Cedars-Sinai Medical Center Los Angeles CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mark Hyun
1Cedars-Sinai Medical Center Los Angeles CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

386

Background: While both myocardial perfusion SPECT and PET imaging provide valuable information regarding three-dimensional distribution of radiotracers into myocardium, there are a number of physical differences where PET has a clear advantage over SPECT. PET has high spatial and temporal resolution, reliable attenuation and scatter correction, short imaging protocols utilizing short-lived positron emitting radiotracers to acquire 3-D acquisition simultaneously which offers tracer kinetic models to obtain absolute myocardial blood flow (MBF) measurements for rest and stress and relative perfusion and function analysis as well. Rb-82 cardiac PET is largely used to study myocardial perfusion and to calculate the MBF and coronary flow reserve (CFR). Although the Rb-82 activity is determined by the patient weight, the infusion volume and activity concentration varies with the age of the Rb-82 generator. We sought to predict the needed bolus volume of Rb-82 to help evaluate the accuracy of MBF findings, despite the other factors that may affect the MBF due to IV size, location and arm position.

Methods: Data was collected from de-identified tickets of a particular brand of Rb-82 generator, calibrated as 100 mCi, which produced 157 clinical elutions over the course of one month. The extracted data included the date, time, total eluted activity, length of time for the elution, and the eluted activity flow rate (in mCi/mL/sec) at each second during the elution. The number of seconds to reach 4 bolus activity levels (20, 30, 40, and 45 mCi) was also recorded for each elution. The activity flow rate for the largest bolus was fitted to determine the functional form. The time to reach each bolus level per elution was fitted as a function of the generator age and 95% confidence limits were created.

Results: The activity flow rate curve was fitted with a growth-saturation model of the form y(t) = A · (t + B) · EXP(-C · t), allowing a calculation of bolus volume. We expected the amplitude “A” to purely depend on the age of the generator; however, it was observed to also be influenced by the time since last elution, and possibly other clinical factors. Elution times to reach the 4 bolus levels were plotted vs. generator age. The log of the bolus times was fitted linearly and 95% confidence limits were created symmetrically around the fit by y-shifting the curve to encompass 95% of the data (90% of the data for 40 and 45 mCi due to lower statistics). The 95% CL band allowed a prediction of elution time to achieve each bolus size for future generators, as a function only of generator age.

Conclusions: A predictive model was created for elution times needed to create a bolus of activity from this brand of Rb-82 generator as a function of generator age. The value of this model is in determining if the necessary amount of activity can be extracted from a generator before hitting one of the backup infusion settings, given a generator age. Some sites may also wish to control the bolus duration for better MBF calculations, since predicting the time for the injection to complete may determine if MBF and CFR calculations are meaningful. Unfortunately, although the eluted activity rate was well fitted by a growth-saturation curve, the amplitude of the curve varied in uncontrollable ways. We plan to investigate in the future if a more precise prediction of injection time than the 95% confidence bands can be made, possibly by controlling other IV and clinical factors.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 60, Issue supplement 1
May 1, 2019
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Predictive model for a Rb-82 generator bolus times as a function of generator lifetime
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Predictive model for a Rb-82 generator bolus times as a function of generator lifetime
Alexander Scott, Mark Hyun
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 386;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Predictive model for a Rb-82 generator bolus times as a function of generator lifetime
Alexander Scott, Mark Hyun
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 386;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Physics, Instrumentation & Data Sciences

  • Clinical feasibility of quantitative holmium-166 SPECT in presence of technetium-99m colloid
  • 3D Structural Convolutional Sparse Coding for PET Image Reconstruction
  • Exploration of Multi-objective Optimization with Genetic Algorithms for PET Image Reconstruction
Show more Physics, Instrumentation & Data Sciences

Instrumentation: Image Quality and Quantitative Imaging

  • A comparison of image quality with uMI780 and the first total-body uEXPLORER scanner
  • The image quality evaluation with various maximum unit difference of the first total-body uEXPLORER scanner
  • Use of a PACS Integrated Injection Monitoring Device to Increase Injection Quality and Infiltration Awareness
Show more Instrumentation: Image Quality and Quantitative Imaging

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire