Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportMolecular Targeting Probes - Radioactive & Nonradioactive

Measurements of dose point kernels using GATE Monte Carlo toolkit for personalized convolution dosimetry

Ashok Tiwari, Stephen Graves and John Sunderland
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 274;
Ashok Tiwari
3Radiology University of Iowa Iowa City IA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Stephen Graves
2Department of Radiation Oncology University of Iowa Iowa City IA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
John Sunderland
1University of Iowa Iowa City IA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

274

Objectives: The goal of this work was to simulate dose point kernels for clinically-relevant radionuclide beta decays and monoenergetic electrons in varying tissue types in order to facilitate accurate patient-specific voxel-wise dosimetry. Currently available voxel-wise approaches to radionuclide dosimetry ignore tissue composition and do not account for density heterogeneities through kernel stretching. More sophisticated convolution superposition algorithms rely on robust pre-tabulated tissue-specific dose kernels, so the work described herein will support advancements in personalized dosimetry.

Methods: Simulations were performed using GATE Monte Carlo toolkit which encapsulates GEANT4 libraries. GATE is a validated simulation software for imaging, radiotherapy and dosimetry applications. Dose point kernels were simulated in phantoms of water, compact bone, lung, adipose tissue, blood, and marrow for radionuclides such as 177Lu, 90Y, 186Re, 188Re, 32P,153Sm, and 89Sr and monoenergetic electrons (0.015-10) MeV. All simulations were performed by assuming an isotropic point-source of electrons at the center of a homogeneous spherical phantom. Absorbed dose was tallied in concentric spherical shells around the point source. Electron step size, determined by the radial bin thickness, was set based on fractional energy loss of electrons (5%, 8.3%, 20%) calculated from a continual slowing down approximation. Higher fractional energy loss per step was therefore associated with fewer radial bins per unit length. Simulation results were validated against literature dose point kernels from other Monte Carlo platforms, namely EGSnrc, FLUKA, PENELOPE, MCNP and also with the earlier version of GATE. Tissue-specific differences between kernels were investigated by normalizing kernels for effective pathlength.

Results: Transport of 20 million particles was found to provide sufficient statistical precision in all simulated kernels. An electron step-size of 8.3% was found to yield diminishing returns in accuracy compared with 5%, where a step size of 20% yielded significant kernel inaccuracy. The simulated dose point kernels demonstrate excellent agreement with other Monte Carlo packages. Deviation from literature kernels does not exceed a 10% global difference, which is consistent with the variability between published results. Tissue-specific kernel differences will be presented and the dose point kernels generated herein will be made freely available upon presentation of this work.

Conclusions: Patients stand to benefit from personalized dosimetry through control of normal tissue toxicity while simultaneously maximizing therapeutic effect. We report the generation of dose point kernels for medically-relevant radioisotopes in water, compact bone, lung, adipose tissue, blood, and marrow. These new kernels provide the necessary inputs for next-generation voxel-wise dosimetry, which will account for tissue type and density.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 60, Issue supplement 1
May 1, 2019
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Measurements of dose point kernels using GATE Monte Carlo toolkit for personalized convolution dosimetry
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Measurements of dose point kernels using GATE Monte Carlo toolkit for personalized convolution dosimetry
Ashok Tiwari, Stephen Graves, John Sunderland
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 274;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Measurements of dose point kernels using GATE Monte Carlo toolkit for personalized convolution dosimetry
Ashok Tiwari, Stephen Graves, John Sunderland
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 274;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Molecular Targeting Probes - Radioactive & Nonradioactive

  • A Unique 18F-labeled G-protein-coupled receptor 44 (GPR44) radiotracer: design, radio-synthesis and evaluation in the rodents
  • Synthesis and Preliminary Evaluation of Metabolically Stable 18F-Lableled PET Tracer for Fatty Acid Beta-Oxidation Imaging.
  • 18F-Radiofluorination of Aryl C-H Bonds using a Tandem Ir C-H Borylation/Cu Radiofluorination Strategy
Show more Molecular Targeting Probes - Radioactive & Nonradioactive

Dosimetry

  • PBPK-based histology-driven in silico tumor microenvironment model for PSMA-directed radioligand therapy
  • Changes of dose equivalent rate in vitro in patients with differentiated thyroid carcinoma after 131I remnant ablation after injection of rHTSH
  • Feasibility of total body dosimetry of Lu-177 SPECT-CT images recorded by a CZT camera
Show more Dosimetry

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire