Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleBasic Science Investigations

64Cu-ATSM Reflects pO2 Levels in Human Head and Neck Cancer Xenografts but Not in Colorectal Cancer Xenografts: Comparison with 64CuCl2

Fan Li, Jesper T. Jørgensen, Julie Forman, Anders E. Hansen and Andreas Kjaer
Journal of Nuclear Medicine March 2016, 57 (3) 437-443; DOI: https://doi.org/10.2967/jnumed.115.155663
Fan Li
1Department of Clinical Physiology, Nuclear Medicine & PET and Cluster for Molecular Imaging, Rigshospitalet and University of Copenhagen, Copenhagen, Denmark
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jesper T. Jørgensen
1Department of Clinical Physiology, Nuclear Medicine & PET and Cluster for Molecular Imaging, Rigshospitalet and University of Copenhagen, Copenhagen, Denmark
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Julie Forman
2Department of Biostatistics, University of Copenhagen, Copenhagen, Denmark; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Anders E. Hansen
1Department of Clinical Physiology, Nuclear Medicine & PET and Cluster for Molecular Imaging, Rigshospitalet and University of Copenhagen, Copenhagen, Denmark
3Center for Nanomedicine and Theranostics, Technical University of Denmark, Kongens Lyngby, Denmark
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Andreas Kjaer
1Department of Clinical Physiology, Nuclear Medicine & PET and Cluster for Molecular Imaging, Rigshospitalet and University of Copenhagen, Copenhagen, Denmark
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Abstract

The hypoxia PET tracer 64Cu-diacetyl-bis(N4-methylthiosemicarbazonate) (64Cu-ATSM) has shown promising results in clinical studies. However, concerns have been raised with regard to the possible effect of copper metabolism and free copper on tumor uptake and thereby the robustness of 64Cu-ATSM as a hypoxia marker. In this study, accumulation and distribution of 64Cu-ATSM and 64CuCl2 in tumor tissue were compared with partial pressure of oxygen (pO2) probe measurements. Methods: One-hour dynamic PET scans were performed on nude mice bearing subcutaneous human head and neck tumors (FaDu) and human colorectal tumors (HT29) after administration of either 64Cu-ATSM or 64CuCl2. Subsequently, tracks were generated and track markers were positioned in tumors to allow for registration of their exact location on the high-resolution CT scan. After completion of the CT scan, pO2 probe measurements were performed along each track. PET and CT images were coregistered and ROIs drawn on the basis of the location of track markers and pO2 probe measurement depth. A linear mixed model for repeated measures was applied for the comparison of PET tracer uptake to corresponding pO2 values. Results: Comparable uptake of 64Cu-ATSM and 64CuCl2 was found in the kidney, muscle, and liver of all animals, but 64CuCl2 showed a higher uptake 10–60 min after injection in both tumor models. Significant differences were also found for both tumor-to-muscle and tumor-to-liver ratios. The intratumoral distribution of 64Cu-ATSM, but not 64CuCl2, showed a significant negative relationship with pO2 measurements in FaDu tumors. However, this relationship was not found in HT29 tumors. Conclusion: 64Cu-ATSM and 64CuCl2 displayed different uptake in tumors. In human head and neck xenografts, 64Cu-ATSM but not 64CuCl2 reflected pO2 measurements, indicating that 64Cu-ATSM is a hypoxia-specific marker in this tumor type. However, data from colorectal cancer xenografts indicated that 64Cu-ATSM may not be a hypoxia marker in all tumor types.

  • PET/CT
  • 64Cu-ATSM
  • hypoxia
  • pO2 probe
  • head and neck cancer xenograft

Tumor hypoxia is associated with an aggressive tumor phenotype and radio- and chemotherapy resistance (1–4). A variety of techniques have been applied to assess hypoxia, but partial pressure of oxygen (pO2) probe measurements are currently regarded as the gold standard and have been extensively used to study the relationship between tumor oxygenation and clinical outcome (1,5–7). However, this method has several limitations due to the inaccessibility of some tumors for needle placement, the limited sampling volume, and the invasive nature of the procedure (8). In addition, the oxygen electrode is unable to distinguish between necrotic and viable hypoxic areas, and insertion of the probe disrupts the tissue at the site of measurement.

Tissue oxygenation can also be quantified with noninvasive imaging techniques, such as MRI, electron paramagnetic resonance, and PET (9,10), and 64Cu-diacetyl-bis(N4-methylthiosemicarbazonate) (64Cu-ATSM) is one of several PET tracers currently under evaluation for imaging of tumor hypoxia. 64Cu-ATSM has a high tumor-to-background ratio and has shown promising results in small clinical studies, in which the tumor-to-muscle ratio was able to predict treatment outcome (11–13). However, the robustness of 64Cu-ATSM as a marker of hypoxia has been questioned, because preclinical studies have reported temporal changes in tumor uptake and cell-type–specific differences in hypoxia selectivity (14–26). Table 1 provides an overview of major studies using 64Cu-ATSM in small-animal tumor xenograft models.

View this table:
  • View inline
  • View popup
TABLE 1

Major Studies Using Cu-ATSM in Small-Animal Tumor Models

The mechanism responsible for 64Cu-ATSM retention is not completely understood, but in vitro studies have indicated that the 64Cu-ATSM complex undergoes reduction by free diffusion after entering the cells (27–29). In normoxic cells, 64Cu-ATSM is rapidly reoxidized and consequently able to leave the cell again by free diffusion. In hypoxic cells, reoxidation occurs at a slower rate, leaving enough time for dissociation of the unstable [64Cu-ATSM]−. The radioactive copper isotope then becomes part of the intracellular copper pool, and some studies have indicated that there also appears to be an efflux of either radiolabeled 64Cu-ATSM or copper from cancer cells (30–32). Moreover, studies of copper metabolism using 64CuCl2 PET in tumor xenograft mouse models have reported high tumor accumulation in some tissue types (33,34). This is interesting with regard to the proposed trapping mechanism and in vivo stability of 64Cu-ATSM, as copper could both accumulate in tumor tissue and redistribute after dissociation from the 64Cu-ATSM complex. Indeed, a recent study comparing 64Cu-ATSM and 64Cu-acetate uptake in tumor-bearing mice found great similarity between the two tracers (16). In addition, in vivo stability experiments indicated that a fraction of 64Cu found in blood was not associated with the 64Cu-ATSM complex within a few minutes after tracer administration (16).

Oxygen probe measurements have previously been applied to compare the uptake of PET tracers to average tumor pO2 values (35–37). Moreover, the technique has also been used for evaluation of the spatial distribution of hypoxia PET tracers in a few studies (21,38,39). In this study, uptake of 64Cu-ATSM and 64CuCl2 was measured in human tumor xenograft-bearing nude mice using small-animal PET, and the intratumoral distribution was compared with pO2 probe measurements.

MATERIALS AND METHODS

Tumor Model

All experiments were performed under national and European Union–approved guidelines for animal welfare. Human head and neck cancer (FaDu) and colorectal cancer (HT29) cell lines (ATCC) were cultured at 37°C and 5% CO2 in minimum essential medium and McCoy 5A medium, respectively, both supplemented with 10% fetal calf serum and 1% penicillin–streptomycin (all from Invitrogen Co.). Seven-week-old female nude NMRI mice (Taconic Europe) had 107 cells, dissolved in 100 μL of medium mixed with 100 μL of Matrixgel Basement Membrane Matrix (BD-Biosciences), subcutaneously inoculated into each flank. Throughout the experiment, the mice were regularly weighed and tumor dimensions measured using a caliper.

Experimental Setup

64CuCl2 and 64Cu-ATSM were produced and synthesized by Risø National Laboratory, Technical University of Denmark. Before the procedure, the animals were weighed and randomized into 4 groups of 4 animals each. All tumors used in this study had diameters of about 10 mm in each dimension. During all procedures, the mice were anesthetized using a mixture of 3% sevoflurane (Abbott Scandinavia AB) mixed with 35% O2 in N2.64Cu-ATSM or 64CuCl2 was injected into a tail vein, and the exact dose calculated (64Cu-ATSM: 8.96 ± 0.65 MBq (mean ± SD); 64CuCl2: 9.47 ± 1.55 MBq) on the basis of measurements of the syringe before and after injection using a radioisotope calibrator (HRC-120; Amersham). Immediately after the injection, the mice were placed on a scanner bed, and the subcutaneous tumors on each flank were positioned for optimal needle access and fixed to eliminate movement. One-hour dynamic scans were performed on a microPET Focus 120 (Siemens Medical Solutions) with a resolution of 1.18 mm (sagittal), 1.13 mm (coronal), and 1.44 mm (transversal) at the center of the field of view. The resulting list-mode data were postprocessed using 3-dimensional maximum a priori algorithms into 256 × 256 × 95 image matrices with a voxel size of 0.43 mm3. For each mouse, frames were defined so they contained data from 10 to 20, 20 to 30, 30 to 40, 40 to 50, and 50 to 60 min from injection to the start of PET acquisition.

After the PET acquisition, two to three 24-gauge vein catheters (Becton Dickinson A/S) were pierced through each tumor and the catheter needle retracted. The plastic catheter tubes were left in the tumor tissue as track markers and for later guidance of pO2 probe insertion. There was a minimum of 3–4 mm between the individual tracks. The animal bed was moved to a small-animal CT scanner and a 7-min CT scan performed. Immediately after completion of the CT scan, the animals were moved to a preheated pO2 measurement platform and a fiber-optic oxygen-sensitive probe (OxyLite 4000; Oxford Optronix) was used to measure local oxygen tension in tumors. More detail on oxygen probe measurement is provided in the supplemental data (available at http://jnm.snmjournals.org).

Data and Statistical Analysis

For each group, pO2 measurements were pooled and cumulative frequency plots of pO2 measurements were used to compare the distribution. Values below 1.5 mm Hg, equal to 2 times the measurement accuracy of the Oxylite measurement system, were excluded from the analysis. After this step, there were 108, 98, 102, and 127 data points left for further analysis in the FaDu 64Cu-ATSM, FaDu 64CuCl2, HT29 64Cu-ATSM, and HT29 64CuCl2, groups, respectively.

All image data were analyzed using Inveon software (Siemens Medical Solutions). PET and CT images were coregistered in 3 dimensions by an affine registration algorithm and visually inspected. Regions of interest (ROIs) were drawn on tumor, muscle, liver, and kidney tissue and uptake calculated as mean %ID/g (percentage injected dose per gram of tissue), tumor-to-muscle ratio, and tumor-to-liver ratio for comparison of image-derived biodistribution. In addition, multiple 20-voxel spheric ROIs (∼0.6 mm3) were placed along each catheter track. This first ROI was placed immediately under the skin, and the distance between each data point was the same as for the pO2 measurements (∼0.5 mm). The uptakes of all regions along each track were calculated as mean %ID/g.

A linear mixed model adjusting for serial correlation (autoregressive) of repeated measurements was used to assess the association between uptake of 64Cu-ATSM or 64CuCl2 and the corresponding pO2 probe measurements when both tumor model and time effect was considered. It was assumed that variation caused by tracer type, tumor model, time, and pO2 and the interactions between them was fixed and that the effect of individual animals was random. Statistical analysis was performed with SPSS statistical software, version 20.0 (IBM Corp.), and Prism 5 (GraphPad Software, Inc.) was used for illustrations. The cumulative frequency plots were visualized using in-house–constructed algorithm using Matlab (version 2014b; The MathWorks, Inc.). PET data are presented as mean ± SEM. A P value of less than 0.05 was considered statistically significant in all analyses.

RESULTS

Comparison of 64Cu-ATSM and 64CuCl2 Uptake

The image-derived biodistribution of 64Cu-ATSM and 64CuCl2 in different tissues from 10 to 60 min after injection was investigated (Fig. 1). Uptake of 64Cu-ATSM was comparable to that of CuCl2 in muscle, kidney, and liver tissue in both tumor models. However, a higher accumulation of 64CuCl2 than of 64Cu-ATSM was found in both FaDu and HT29 tumors, resulting in significantly higher tumor-to-muscle and tumor-to-liver ratios (Figs. 2 and 3). Also, a higher variation in tumor and liver uptake between animals was observed in the 64CuCl2 group.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Image-derived biodistribution of 64Cu-ATSM and 64CuCl2 obtained from dynamic PET scans performed 10–60 min after injection. Uptake in FaDu tumor–bearing mice of 64Cu-ATSM (black symbols) (n = 4) and 64CuCl2 (blue symbols) (n = 4) and uptake in HT29 mice of 64Cu-ATSM (red symbols) (n = 4) and 64CuCl2 (green symbols) (n = 4) is given as mean %ID/g ± SEM in tumor (A), liver (B), kidney (C), and muscle (D). Animals were anesthetized during scans by breathing 3% sevoflurane mixed with 35% O2 in N2.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Representative transaxial PET images 50–60 min after injection of FaDu tumor–bearing mice with 64Cu-ATSM (A) and 64CuCl2 (B) and of HT29 tumor–bearing mice with 64Cu-ATSM (C) and 64CuCl2 (D) (arrows indicate tumors).

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Tumor-to-liver (A) and tumor-to-muscle (B) ratios from dynamic 64Cu-ATSM or 64CuCl2 PET scans performed 10–60 min after injection. Uptake in FaDu mice of 64Cu-ATSM (black symbols) (n = 4) and 64CuCl2 (blue symbols) (n = 4) and uptake in HT29 mice of 64Cu-ATSM (red symbols) (n = 4) and 64CuCl2 (green symbols) (n = 4) is shown. Animals were anesthetized during scans by breathing 3% sevoflurane mixed with 35% O2 in N2.

Intratumoral pO2 Measurements

The pO2 values obtained with the oxygen probe in FaDu tumors ranged from −0.55 to 53 mm Hg in the 64Cu-ATSM group and −0.72 to 46 mm Hg in the 64CuCl2 group. In HT29 tumors, the pO2 values ranged from −0.60 to 57.74 mm Hg in the 64Cu-ATSM group and −0.86 to 60.04 mm Hg in the 64CuCl2 group. To evaluate the compatibility of pO2 measurement in the 64Cu-ATSM and 64CuCl2 groups, the relative frequency of readings ≤2.5, ≤5, and ≤10 mm Hg and the mean and median pO2 were determined on the basis of the cumulative median frequency plots (Supplemental Figs. 2 and 3). In the FaDu tumor–bearing mice, the 64Cu-ATSM group had 64%, 68%, and 77% of measurements ≤2.5 mm Hg, ≤5 mm Hg, and ≤10 mm Hg, respectively. The respective percentages in the 64CuCl2 group were 60%, 64%, and 72%. In the HT29 tumor–bearing mice, the 64Cu-ATSM group had 74%, 78%, and 81% of measurements ≤2.5 mm Hg, ≤5 mm Hg, and ≤10 mm Hg, respectively. The respective percentages in the 64CuCl2 group were 66%, 76%, and 81%.

Intratumoral 64CuCl2 and 64Cu-ATSM Uptake and pO2 Measurements

The possible association between the pO2 probe measurements and 64Cu-ATSM and 64CuCl2 uptake in corresponding regions in FaDu and HT29 tumors was evaluated by a linear mixed model (Table 2). We found a significant negative association between pO2 and the mean %ID/g of 64Cu-ATSM in FaDu tumors (P < 0.0001), whereas no significant association was found between pO2 and 64CuCl2 (P = 0.248). In the HT29 tumors, no significant association was found between either 64Cu-ATSM or 64CuCl2 uptake and pO2 (P = 0.590 and P = 0.132, respectively) (Table 2). In FaDu tumors, the association between pO2 and mean 64Cu-ATSM was found to be significant at all time points. The changes in regression coefficients over time were small and nonsystematic (Table 3). Figures 4 and 5 show the relationships between tracer uptake and pO2 at 50–60 min after injection in FaDu and HT29 tumors, respectively.

View this table:
  • View inline
  • View popup
TABLE 2

Regression Coefficients for Effect of pO2 on PET Tracer Uptake

View this table:
  • View inline
  • View popup
TABLE 3

Estimated Effect of pO2 on PET Tracer Uptake at Different Time Points

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

Comparison between pO2 probe measurements and tracer uptake (mean %ID/g) in FaDu tumor subvolumes. (A) 64Cu-ATSM 50–60 min after injection. (B) 64CuCl2 50–60 min after injection. Number of tumor subvolumes used for analysis was 108 for 64Cu-ATSM and 96 for 64CuCl2.

FIGURE 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 5.

Comparison between pO2 measurements and tracer uptake (mean %ID/g) in HT29 tumor subvolumes. (A) 64Cu-ATSM 50–60 min after injection. (B) 64CuCl2 50–60 min after injection. Number of tumor subvolumes used for analysis was 102 for 64Cu-ATSM and 127 for 64CuCl2.

DISCUSSION

The mechanism responsible for 64Cu-ATSM retention is not fully understood, and recently there has been a focus on the possible effect of copper metabolism on tumor uptake (16,33). A recent study compared 64Cu-ATSM and 64Cu-acetate uptake in tumor-bearing mice and reported that the two tracers had similar biodistributions (16). Moreover, the immunohistochemical hypoxia marker 2-(2-nitro-1H-imidazol-1-yl)-N-(2,2,3,3,3-pentafluoropropyl)-acetamide (EF5) correlated with the late (16 h), but not the early (15 min and 2 h), intratumoral tracer distribution of both 64Cu-ATSM and 64Cu-acetate (16). It was previously reported that the relationship between 64Cu-ATSM and EF5 accumulation in tumors is dependent on tissue type (25). However, the similarity in biodistribution and tumor uptake shown by 64Cu-acetate and 64Cu-ATSM could indicate that a large fraction of the 64Cu that had initially bound to ATSM dissociated.

In this study, we also found a similar accumulation of copper in kidney, liver, and muscle tissue using 64Cu-ATSM and 64CuCl2 PET. However, in contrast, 64CuCl2 showed a higher uptake than 64Cu-ATSM in both HT29 and FaDu tumors at all time points. Also, different relationships between pO2 and the spatial distribution of 64CuCl2 and 64Cu-ATSM were found. The level of tumor uptake and tumor-to-background ratios of both 64Cu-ATSM and 64CuCl2 found in this study seems to be lower than has previously been reported (14,20,33). However, during the 1-h dynamic scans, the tumor-to-muscle ratios of both 64Cu-ATSM and 64CuCl2 continued to increase and did not reach a plateau. Importantly, the different imaging time points and anesthetic procedures applied in the different studies complicate a direct comparison of results. It has previously been shown that both anesthetics and level of oxygen in anesthetic gas mixtures can influence tissue uptake of both 64Cu-ATSM and copper (16,17). Therefore, to avoid fluctuations in uptake, the level of the anesthetic gas mixture was strictly kept at a constant level during all procedures from tracer injection until completion of pO2 probe measurements. However, the experimental setup has likely contributed to slower accumulation and clearance from the background than would be seen when the tracer is allowed to distribute in an unanesthetized animal (16,17).

A previous study on nude rats with FaDu tumors found no correlation between hypoxia marker, pimonidazole, and intratumoral spatial distribution of 64Cu-ATSM 1 and 18 h after injection (20). In contrast, another study using the same tumor model found that there was no temporal change in the intratumoral distribution of 64Cu-ATSM early (2 h) or late (16 h) after injection and that pO2 probe measurements from different tumor sections corroborated well with PET images (21). This is consistent with our finding of a negative relationship between pO2 probe measurements and the intratumoral spatial distribution of 64Cu-ATSM in FaDu. However, when we performed the same experiment on mice bearing HT29 tumors no relationship was found. A tumor type–dependent difference between intratumoral 64Cu-ATSM accumulation and other hypoxic markers has previously been reported by others, and a study comparing the spatial distribution of 64Cu-ATSM to pimonidazole in mice bearing HT29 tumors also found no relationship (14,25).

pO2 probe measurements are considered the gold standard for determining tissue oxygenation and are therefore an attractive method for evaluating the performance of hypoxia PET tracers. As previously mentioned, however, this approach has some limitations. We used cumulative median frequency plotting to verify a good similarity between the distributions of pO2 readings in the two tumor models before making the comparison with 64Cu-ATSM and 64CuCl2 accumulation. However, one limitation to the oxygen probe is that it cannot distinguish between necrotic and severely hypoxic tissue. Recordings performed on necrotic tumor areas are problematic for the comparison with tracer uptake because these regions consists of nonviable cells unable to accumulate 64Cu-ATSM, which could be interpreted as hypoxic. FaDu and HT29 tumors grown subcutaneously in nude mice are likely to develop central necrosis, and a significant number of the obtained pO2 values were near zero. Therefore, to include only viable tumor tissue, pO2 values below 2 times the measurement accuracy of the probe (<1.5 mm Hg) were excluded from the analysis. Also, as probe insertion is invasive, there is a possibility that it induces changes in oxygenation. Using our setup, there is a risk of inducing changes in microregional tumor oxygenation between the PET scan and the pO2 probe recordings, leading to a mismatch between corresponding measurements. Microregional changes in tumor perfusion (acute hypoxia) could also have the same effect. Moreover, the analysis is sensitive with regard to misalignment between ROIs in PET images and the corresponding pO2 measurements. Even though the tumors were fixed during needle penetration, movement could affect the coregistration, but any effect is likely limited as the ROIs placed on the PET images covered a much larger subvolume of the tumor than the microregional sample volume of the oxygen probe. However, this discrepancy in volume can also induce variation, as uptake from ROIs represents average values of tracer accumulation within larger regions, potentially comprising microregional differences in oxygenation.

Overall, despite conflicting preclinical findings, 64Cu-ATSM is a promising PET tracer because it has shown the ability to predict treatment outcome in small patient studies. However, improved understanding of the tissue-specific selectivity and temporal evolution of distribution, also with regard to in vivo stability, is important for optimal application of the tracer. Moreover, it is not clear whether the preclinical findings can be translated into patients. Therefore, further clinical studies are required on whether tumor uptake of 64Cu-ATSM can be used as a hypoxia marker or, alternatively, to provide other prognostic information.

CONCLUSION

In human head and neck xenografts, 64Cu-ATSM but not 64CuCl2 reflected pO2 measurements, indicating that 64Cu-ATSM is indeed a hypoxia marker in this tumor type. However, data from colorectal cancer xenografts indicated that 64Cu-ATSM may not be a hypoxia marker in all tumor types.

DISCLOSURE

The costs of publication of this article were defrayed in part by the payment of page charges. Therefore, and solely to indicate this fact, this article is hereby marked “advertisement” in accordance with 18 USC section 1734. This work was financially supported by the Lundbeck Foundation, the Novo Nordisk Foundation, the Svend Andersen Foundation, the Arvid Nilsson Foundation, Innovationsfonden, the Research Fund of Rigshospitalet, the Capital Region of Denmark, and the John and Birthe Meyer Foundation. No other potential conflict of interest relevant to this article was reported.

Footnotes

  • Published online Nov. 19, 2015.

  • © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

REFERENCES

  1. 1.↵
    1. Brizel DM,
    2. Sibley GS,
    3. Prosnitz LR,
    4. Scher RL,
    5. Dewhirst MW
    . Tumor hypoxia adversely affects the prognosis of carcinoma of the head and neck. Int J Radiat Oncol Biol Phys. 1997;38:285–289.
    OpenUrlCrossRefPubMed
  2. 2.
    1. Brown JM
    . The hypoxic cell: a target for selective cancer therapy—eighteenth Bruce F. Cain Memorial Award lecture. Cancer Res. 1999;59:5863–5870.
    OpenUrlAbstract/FREE Full Text
  3. 3.
    1. Hockel M,
    2. Schlenger K,
    3. Aral B,
    4. Mitze M,
    5. Schaffer U,
    6. Vaupel P
    . Association between tumor hypoxia and malignant progression in advanced cancer of the uterine cervix. Cancer Res. 1996;56:4509–4515.
    OpenUrlAbstract/FREE Full Text
  4. 4.↵
    1. Nordsmark M,
    2. Bentzen SM,
    3. Rudat V,
    4. et al
    . Prognostic value of tumor oxygenation in 397 head and neck tumors after primary radiation therapy: an international multi-center study. Radiother Oncol. 2005;77:18–24.
    OpenUrlCrossRefPubMed
  5. 5.↵
    1. Höckel M,
    2. Vorndran B,
    3. Schlenger K,
    4. Baussmann E,
    5. Knapstein PG
    . Tumor oxygenation: a new predictive parameter in locally advanced cancer of the uterine cervix. Gynecol Oncol. 1993;51:141–149.
    OpenUrlCrossRefPubMed
  6. 6.
    1. Nordsmark M,
    2. Loncaster J,
    3. Chou SC,
    4. et al
    . Invasive oxygen measurements and pimonidazole labeling in human cervix carcinoma. Int J Radiat Oncol Biol Phys. 2001;49:581–586.
    OpenUrlCrossRefPubMed
  7. 7.↵
    1. Nordsmark M,
    2. Overgaard J
    . A confirmatory prognostic study on oxygenation status and loco-regional control in advanced head and neck squamous cell carcinoma treated by radiation therapy. Radiother Oncol. 2000;57:39–43.
    OpenUrlCrossRefPubMed
  8. 8.↵
    1. Gaertner FC,
    2. Souvatzoglou M,
    3. Brix G,
    4. Beer AJ
    . Imaging of hypoxia using PET and MRI. Curr Pharm Biotechnol. 2012;13:552–570.
    OpenUrlCrossRefPubMed
  9. 9.↵
    1. Bobko AA,
    2. Dhimitruka I,
    3. Eubank TD,
    4. Marsh CB,
    5. Zweier JL,
    6. Khramtsov VV
    . Trityl-based EPR probe with enhanced sensitivity to oxygen. Free Radic Biol Med. 2009;47:654–658.
    OpenUrlCrossRefPubMed
  10. 10.↵
    1. Yasui H,
    2. Matsumoto S,
    3. Devasahayam N,
    4. et al
    . Low-field magnetic resonance imaging to visualize chronic and cycling hypoxia in tumor-bearing mice. Cancer Res. 2010;70:6427–6436.
    OpenUrlAbstract/FREE Full Text
  11. 11.↵
    1. Dehdashti F,
    2. Mintun MA,
    3. Lewis JS,
    4. et al
    . In vivo assessment of tumor hypoxia in lung cancer with 60Cu-ATSM. Eur J Nucl Med Mol Imaging. 2003;30:844–850.
    OpenUrlCrossRefPubMed
  12. 12.
    1. Dehdashti F,
    2. Grigsby PW,
    3. Lewis JS,
    4. Laforest R,
    5. Siegel BA,
    6. Welch MJ
    . Assessing tumor hypoxia in cervical cancer by PET with 60Cu-labeled diacetyl-bis(N4-methylthiosemicarbazone). J Nucl Med. 2008;49:201–205.
    OpenUrlAbstract/FREE Full Text
  13. 13.↵
    1. Dietz DW,
    2. Dehdashti F,
    3. Grigsby PW,
    4. et al
    . Tumor hypoxia detected by positron emission tomography with 60Cu-ATSM as a predictor of response and survival in patients undergoing neoadjuvant chemoradiotherapy for rectal carcinoma: a pilot study. Dis Colon Rectum. 2008;51:1641–1648.
    OpenUrlCrossRefPubMed
  14. 14.↵
    1. Carlin S,
    2. Zhang H,
    3. Reese M,
    4. Ramos NN,
    5. Chen Q,
    6. Ricketts SA
    . A comparison of the imaging characteristics and microregional distribution of 4 hypoxia PET tracers. J Nucl Med. 2014;55:515–521.
    OpenUrlAbstract/FREE Full Text
  15. 15.
    1. Dence CS,
    2. Ponde DE,
    3. Welch MJ,
    4. Lewis JS
    . Autoradiographic and small-animal PET comparisons between 18F-FMISO, 18F-FDG, 18F-FLT and the hypoxic selective 64Cu-ATSM in a rodent model of cancer. Nucl Med Biol. 2008;35:713–720.
    OpenUrlCrossRefPubMed
  16. 16.↵
    1. Hueting R,
    2. Kersemans V,
    3. Cornelissen B,
    4. et al
    . A comparison of the behavior of 64Cu-acetate and 64Cu-ATSM in vitro and in vivo. J Nucl Med. 2014;55:128–134.
    OpenUrlAbstract/FREE Full Text
  17. 17.↵
    1. Kersemans V,
    2. Cornelissen B,
    3. Hueting R,
    4. et al
    . Hypoxia imaging using PET and SPECT: the effects of anesthetic and carrier gas on [Cu]-ATSM, [Tc]-HL91 and [F]-FMISO tumor hypoxia accumulation. PLoS One. 2011;6:e25911.
    OpenUrlCrossRefPubMed
  18. 18.
    1. Lewis JS,
    2. Sharp TL,
    3. Laforest R,
    4. Fujibayashi Y,
    5. Welch MJ
    . Tumor uptake of copper-diacetyl-bis(N4-methylthiosemicarbazone): effect of changes in tissue oxygenation. J Nucl Med. 2001;42:655–661.
    OpenUrlAbstract/FREE Full Text
  19. 19.
    1. Matsumoto K,
    2. Szajek L,
    3. Krishna MC,
    4. et al
    . The influence of tumor oxygenation on hypoxia imaging in murine squamous cell carcinoma using [64Cu]Cu-ATSM or [18F]fluoromisonidazole positron emission tomography. Int J Oncol. 2007;30:873–881.
    OpenUrlPubMed
  20. 20.↵
    1. McCall KC,
    2. Humm JL,
    3. Bartlett R,
    4. Reese M,
    5. Carlin S
    . Copper-64-diacetyl-bis(N4-methylthiosemicarbazone) pharmacokinetics in FaDu xenograft tumors and correlation with microscopic markers of hypoxia. Int J Radiat Oncol Biol Phys. 2012;84:e393–e399.
    OpenUrlCrossRefPubMed
  21. 21.↵
    1. O’Donoghue JA,
    2. Zanzonico P,
    3. Pugachev A,
    4. et al
    . Assessment of regional tumor hypoxia using 18F-fluoromisonidazole and 64Cu(II)-diacetyl-bis(N4-methylthiosemicarbazone) positron emission tomography: comparative study featuring microPET imaging, Po2 probe measurement, autoradiography, and fluorescent microscopy in the R3327-AT and FaDu rat tumor models. Int J Radiat Oncol Biol Phys. 2005;61:1493–1502.
    OpenUrlCrossRefPubMed
  22. 22.
    1. Oh M,
    2. Tanaka T,
    3. Kobayashi M,
    4. et al
    . Radio-copper-labeled Cu-ATSM: an indicator of quiescent but clonogenic cells under mild hypoxia in a Lewis lung carcinoma model. Nucl Med Biol. 2009;36:419–426.
    OpenUrlCrossRefPubMed
  23. 23.
    1. Tanaka T,
    2. Furukawa T,
    3. Fujieda S,
    4. Kasamatsu S,
    5. Yonekura Y,
    6. Fujibayashi Y
    . Double-tracer autoradiography with Cu-ATSM/FDG and immunohistochemical interpretation in four different mouse implanted tumor models. Nucl Med Biol. 2006;33:743–750.
    OpenUrlCrossRefPubMed
  24. 24.
    1. Valtorta S,
    2. Belloli S,
    3. Sanvito F,
    4. et al
    . Comparison of 18F-fluoroazomycin-arabinofuranoside and 64Cu-diacetyl-bis(N4-methylthiosemicarbazone) in preclinical models of cancer. J Nucl Med. 2013;54:1106–1112.
    OpenUrlAbstract/FREE Full Text
  25. 25.↵
    1. Yuan H,
    2. Schroeder T,
    3. Bowsher JE,
    4. Hedlund LW,
    5. Wong T,
    6. Dewhirst MW
    . Intertumoral differences in hypoxia selectivity of the PET imaging agent 64Cu(II)-diacetyl-bis(N4-methylthiosemicarbazone). J Nucl Med. 2006;47:989–998.
    OpenUrlAbstract/FREE Full Text
  26. 26.↵
    1. Hansen AE,
    2. Kristensen AT,
    3. Law I,
    4. McEvoy FJ,
    5. Kjaer A,
    6. Engelholm SA
    . Multimodality functional imaging of spontaneous canine tumors using 64Cu-ATSM and 18FDG PET/CT and dynamic contrast enhanced perfusion CT. Radiother Oncol. 2012;102:424–428.
    OpenUrlCrossRefPubMed
  27. 27.↵
    1. Maurer RI,
    2. Blower PJ,
    3. Dilworth JR,
    4. Reynolds CA,
    5. Zheng Y,
    6. Mullen GE
    . Studies on the mechanism of hypoxic selectivity in copper bis(thiosemicarbazone) radiopharmaceuticals. J Med Chem. 2002;45:1420–1431.
    OpenUrlCrossRefPubMed
  28. 28.
    1. Obata A,
    2. Yoshimi E,
    3. Waki A,
    4. et al
    . Retention mechanism of hypoxia selective nuclear imaging/radiotherapeutic agent cu-diacetyl-bis(N4-methylthiosemicarbazone) (Cu-ATSM) in tumor cells. Ann Nucl Med. 2001;15:499–504.
    OpenUrlCrossRefPubMed
  29. 29.↵
    1. Donnelly PS,
    2. Liddell JR,
    3. Lim S,
    4. et al
    . An impaired mitochondrial electron transport chain increases retention of the hypoxia imaging agent diacetylbis(4-methylthiosemicarbazonato)copperII. Proc Natl Acad Sci USA. 2012;109:47–52.
    OpenUrlAbstract/FREE Full Text
  30. 30.↵
    1. Burgman P,
    2. O’Donoghue JA,
    3. Lewis JS,
    4. Welch MJ,
    5. Humm JL,
    6. Ling CC
    . Cell line-dependent differences in uptake and retention of the hypoxia-selective nuclear imaging agent Cu-ATSM. Nucl Med Biol. 2005;32:623–630.
    OpenUrlCrossRefPubMed
  31. 31.
    1. Liu J,
    2. Hajibeigi A,
    3. Ren G,
    4. et al
    . Retention of the radiotracers 64Cu-ATSM and 64Cu-PTSM in human and murine tumors is influenced by MDR1 protein expression. J Nucl Med. 2009;50:1332–1339.
    OpenUrlAbstract/FREE Full Text
  32. 32.↵
    1. Price KA,
    2. Crouch PJ,
    3. Volitakis I,
    4. et al
    . Mechanisms controlling the cellular accumulation of copper bis(thiosemicarbazonato) complexes. Inorg Chem. 2011;50:9594–9605.
    OpenUrlCrossRefPubMed
  33. 33.↵
    1. Jørgensen JT,
    2. Persson M,
    3. Madsen J,
    4. Kjaer A
    . High tumor uptake of 64Cu: implications for molecular imaging of tumor characteristics with copper-based PET tracers. Nucl Med Biol. 2013;40:345–350.
    OpenUrlCrossRefPubMed
  34. 34.↵
    1. Peng F,
    2. Lu X,
    3. Janisse J,
    4. Muzik O,
    5. Shields AF
    . PET of human prostate cancer xenografts in mice with increased uptake of 64CuCl2. J Nucl Med. 2006;47:1649–1652.
  35. 35.↵
    1. Busk M,
    2. Horsman MR,
    3. Jakobsen S,
    4. et al
    . Imaging hypoxia in xenografted and murine tumors with 18F-fluoroazomycin arabinoside: a comparative study involving microPET, autoradiography, PO2-polarography, and fluorescence microscopy. Int J Radiat Oncol Biol Phys. 2008;70:1202–1212.
    OpenUrlCrossRefPubMed
  36. 36.
    1. Gagel B,
    2. Piroth M,
    3. Pinkawa M,
    4. et al
    . pO polarography, contrast enhanced color duplex sonography (CDS), [18F] fluoromisonidazole and [18F] fluorodeoxyglucose positron emission tomography: validated methods for the evaluation of therapy-relevant tumor oxygenation or only bricks in the puzzle of tumor hypoxia? BMC Cancer. 2007;7:113.
    OpenUrlCrossRefPubMed
  37. 37.↵
    1. Tran LB,
    2. Bol A,
    3. Labar D,
    4. et al
    . Hypoxia imaging with the nitroimidazole 18F-FAZA PET tracer: a comparison with OxyLite, EPR oximetry and 19F-MRI relaxometry. Radiother Oncol. 2012;105:29–35.
    OpenUrlCrossRefPubMed
  38. 38.↵
    1. Bartlett RM,
    2. Beattie BJ,
    3. Naryanan M,
    4. et al
    . Image-guided PO2 probe measurements correlated with parametric images derived from 18F-fluoromisonidazole small-animal pet data in rats. J Nucl Med. 2012;53:1608–1615.
    OpenUrlAbstract/FREE Full Text
  39. 39.↵
    1. Chang J,
    2. Wen B,
    3. Kazanzides P,
    4. et al
    . A robotic system for 18F-FMISO PET-guided intratumoral pO2 measurements. Med Phys. 2009;36:5301–5309.
    OpenUrlCrossRefPubMed
  • Received for publication February 17, 2015.
  • Accepted for publication October 22, 2015.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 57 (3)
Journal of Nuclear Medicine
Vol. 57, Issue 3
March 1, 2016
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
64Cu-ATSM Reflects pO2 Levels in Human Head and Neck Cancer Xenografts but Not in Colorectal Cancer Xenografts: Comparison with 64CuCl2
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
64Cu-ATSM Reflects pO2 Levels in Human Head and Neck Cancer Xenografts but Not in Colorectal Cancer Xenografts: Comparison with 64CuCl2
Fan Li, Jesper T. Jørgensen, Julie Forman, Anders E. Hansen, Andreas Kjaer
Journal of Nuclear Medicine Mar 2016, 57 (3) 437-443; DOI: 10.2967/jnumed.115.155663

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
64Cu-ATSM Reflects pO2 Levels in Human Head and Neck Cancer Xenografts but Not in Colorectal Cancer Xenografts: Comparison with 64CuCl2
Fan Li, Jesper T. Jørgensen, Julie Forman, Anders E. Hansen, Andreas Kjaer
Journal of Nuclear Medicine Mar 2016, 57 (3) 437-443; DOI: 10.2967/jnumed.115.155663
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Radiomics in PET/CT: More Than Meets the Eye?
  • Google Scholar

More in this TOC Section

  • 11C-Methionine PET of Myocardial Inflammation in a Rat Model of Experimental Autoimmune Myocarditis
  • Counting Rate Characteristics and Image Distortion in Preclinical PET Imaging During Radiopharmaceutical Therapy
  • Design and Fabrication of Kidney Phantoms for Internal Radiation Dosimetry Using 3D Printing Technology
Show more Basic Science Investigations

Similar Articles

Keywords

  • PET/CT
  • 64Cu-ATSM
  • hypoxia
  • pO2 probe
  • head and neck cancer xenograft
SNMMI

© 2025 SNMMI

Powered by HighWire