Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportTechnologist Abstracts

Linearity estimation of PET/CT scanner in list mode acquisition

Hyeon Jun Choi, Byung jin Kim, Mikiko Ito, Hong Jae Lee, Hyun Joo Kim, Jae Sung Lee and Dong Soo Lee
Journal of Nuclear Medicine May 2011, 52 (supplement 1) 2318;
Hyeon Jun Choi
1Seoul National University Hospital, Seoul, Republic of Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Byung jin Kim
1Seoul National University Hospital, Seoul, Republic of Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mikiko Ito
2Seoul National University, Seoul, Republic of Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hong Jae Lee
1Seoul National University Hospital, Seoul, Republic of Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hyun Joo Kim
1Seoul National University Hospital, Seoul, Republic of Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jae Sung Lee
2Seoul National University, Seoul, Republic of Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Dong Soo Lee
1Seoul National University Hospital, Seoul, Republic of Korea
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

2318

Objectives Quantification of myocardial blood flow (MBF) using dynamic PET imaging has the potential to assess coronary artery disease. Rb-82 plays a key role in the clinical assessment of myocardial perfusion using PET. However, MBF could be overestimated due to the underestimation of left ventricular input function in the beginning of the acquisition when the scanner has non-linearity between count rate and activity concentration due to the scanner dead-time. Therefore, in this study, we evaluated the count rate linearity as a function of the activity concentration in PET data acquired in list mode.

Methods A cylindrical phantom (diameter, 12 cm; length, 10.5 cm) filled with 296 MBq F-18 solution and 800 ml of water was used to estimate the linearity of the Biograph 40 True Point PET/CT scanner. PET data was acquired with 10-min frame of 1 bed duration in list mode for different activity concentration levels in 7 half-lives. The images were reconstructed by OSEM and FBP algorithms. Prompt, net true, and random counts of PET data according to the activity concentration were measured. Total and background counts were measured by drawing ROI on the phantom images and linearity was measured using background correction.

Results The prompt count rates in list mode were linearly increased proportionally to the activity concentration. At a low activity concentration (<30 kBq/ml), the prompt net true and random count rates were increased with the activity concentration. At a high activity concentration (>30 kBq/ml), the increasing rate of the prompt net true rates was slightly decreased while the increasing rate of random counts was increased. There was no difference in the image intensity linearity between OSEM and FBP algorithms.

Conclusions The Biograph 40 True Point PET/CT scanner showed good linearity of count rate even at a high activity concentration (~370 kBq/ml). The result indicates that the scanner is useful for the quantitative analysis of data in heart dynamic studies using Rb-82, N-13, O-15, and F-18

Back to top

In this issue

Journal of Nuclear Medicine
Vol. 52, Issue supplement 1
May 2011
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Linearity estimation of PET/CT scanner in list mode acquisition
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Linearity estimation of PET/CT scanner in list mode acquisition
Hyeon Jun Choi, Byung jin Kim, Mikiko Ito, Hong Jae Lee, Hyun Joo Kim, Jae Sung Lee, Dong Soo Lee
Journal of Nuclear Medicine May 2011, 52 (supplement 1) 2318;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Linearity estimation of PET/CT scanner in list mode acquisition
Hyeon Jun Choi, Byung jin Kim, Mikiko Ito, Hong Jae Lee, Hyun Joo Kim, Jae Sung Lee, Dong Soo Lee
Journal of Nuclear Medicine May 2011, 52 (supplement 1) 2318;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Technologist Abstracts

  • Relative contribution of CT dose in SPECT/CT imaging
  • Measurement of the radiation emitted by nuclear medicine patients for radiation shielding calculations
  • A newly proposed method to define cerebellar reference region optimized for individual BF-227 PET
Show more Technologist Abstracts

Technologist Scientific Papers III

  • Quantitative image characteristics of presynaptic dopamine transporter (DAT) scans
  • Evaluation of global and regional myocardial uptake of MIBG-I123 with multimodality acquisition
  • Errors in attenuation correction with ECG-gated myocardial PET/CT images: Evaluation with phantom study
Show more Technologist Scientific Papers III

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire