Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis: Image Generation

Comparison of PET reconstruction resolution recovery and post-reconstruction deconvolution for partial volume effect correction (PVC) in PET

Adrien Le Pogam, Adam Alessio, Benjamin Kandel, Assen Kirov, Olivier Barret, Philippe Fernandez, Catherine Cheze Le Rest and Dimitris Visvikis
Journal of Nuclear Medicine May 2010, 51 (supplement 2) 577;
Adrien Le Pogam
1LaTIM, INSERM U650, INSERM, Brest, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Adam Alessio
2Department of Radiology, University of Washington, Seattle, WA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Benjamin Kandel
3Department of Medical Physics, MSKCC, New York, NY
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Assen Kirov
3Department of Medical Physics, MSKCC, New York, NY
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Olivier Barret
4Service de Médecine Nucléaire, CHU Bordeaux, Bordeaux, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Philippe Fernandez
4Service de Médecine Nucléaire, CHU Bordeaux, Bordeaux, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Catherine Cheze Le Rest
1LaTIM, INSERM U650, INSERM, Brest, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Dimitris Visvikis
1LaTIM, INSERM U650, INSERM, Brest, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

577

Objectives In this study we compare an OSEM algorithm incorporating measured point spread functions (PSF) modeling for resolution recovery, and two post-reconstruction methods for PVC in PET.

Methods The first methodology (Alessio et al, IEEE ISBI, 2008:1315) uses measured PSF, which blur among radial bins and are spatially variant in radial location, incorporated into a 3D-OSEM algorithm. Post-reconstruction PVC was applied using two different regularized 3D iterative deconvolution algorithms (Boussion et al, EJNMMI, 2009, 36:1064 / Kirov et al, PMB, 2008, 53:2577). The comparison was performed on both Ge68 PET/CT acquisitions of the IEC phantom with different configurations (acquisition duration, post filtering, number of iterations) as well as 10 clinical 18F-FDG whole body studies. A qualitative and quantitative comparison of the corrected images with those reconstructed using a standard OSEM reconstruction was performed.

Results The deconvolution algorithms showed superior results in terms of resolution recovery and quantitative accuracy, despite a slightly higher (<10-15%) level of noise introduced in the corrected images. For phantom spheres <2cm the deconvolution approaches led to higher (15%-35%) activity concentration recovery relative to the reconstruction based approach including post filtering. The phantom results were confirmed by the patient images with the deconvolution leading to an increase in activity concentration recovery of the lesions of up to 30% and an associated noise increase of <10% in the lungs and liver relative to the reconstruction based recovery.

Conclusions Results suggest that performing both reconstruction and post-reconstruction methods offers improved quantitative accuracy, although post-processing deconvolution approaches lead to overall higher SNR increases

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 51, Issue supplement 2
May 2010
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Comparison of PET reconstruction resolution recovery and post-reconstruction deconvolution for partial volume effect correction (PVC) in PET
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Comparison of PET reconstruction resolution recovery and post-reconstruction deconvolution for partial volume effect correction (PVC) in PET
Adrien Le Pogam, Adam Alessio, Benjamin Kandel, Assen Kirov, Olivier Barret, Philippe Fernandez, Catherine Cheze Le Rest, Dimitris Visvikis
Journal of Nuclear Medicine May 2010, 51 (supplement 2) 577;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Comparison of PET reconstruction resolution recovery and post-reconstruction deconvolution for partial volume effect correction (PVC) in PET
Adrien Le Pogam, Adam Alessio, Benjamin Kandel, Assen Kirov, Olivier Barret, Philippe Fernandez, Catherine Cheze Le Rest, Dimitris Visvikis
Journal of Nuclear Medicine May 2010, 51 (supplement 2) 577;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis: Image Generation

  • Visualization and dose estimation of 90Y-ibritumomab-tiukisetan accumulation in lymphoma patients using TOF PET/CT
  • Absolute Tc99m activity quantitation in cardiac phantom using commercialized SPECT/CT scanner capable of rapid multiple-phase dynamic acquisition
  • Realigning PET/CT data prior to reconstruction: When is it necessary?
Show more Instrumentation & Data Analysis: Image Generation

Image Generation: Reconstruction

  • Fast and efficient PET image reconstruction using sparse system matrix factorization
  • Evaluation of 3D reconstruction methods for reduced acquisition time using channelized Hotelling observer for myocardial perfusion SPECT
  • Space-variant image-based resolution modeling kernels for enhanced whole-body oncology imaging with the HiRez PET/CT scanner
Show more Image Generation: Reconstruction

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire