Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
OtherBASIC SCIENCE INVESTIGATIONS

Quantitative Kinetics of [124I]FIAU in Cat and Man

Andreas Jacobs, Ines Bräunlich, Rudolf Graf, Martin Lercher, Takayuki Sakaki, Jürgen Voges, Volker Hesselmann, Wolfgang Brandau, Klaus Wienhard and Wolf-Dieter Heiss
Journal of Nuclear Medicine March 2001, 42 (3) 467-475;
Andreas Jacobs
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ines Bräunlich
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Rudolf Graf
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Martin Lercher
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Takayuki Sakaki
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jürgen Voges
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Volker Hesselmann
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Wolfgang Brandau
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Klaus Wienhard
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Wolf-Dieter Heiss
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Article Figures & Data

Figures

  • Tables
  • FIGURE 1.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 1.

    Multitracer PET imaging of ventilated cat allows functional analysis of various tissues of total body at same physiologic status over prolonged period of time using specific radiotracers. Coregistered MRI allows anatomic delineation of various organs. In healthy cat brain, physiologic glucose ([18F]FDG) and oxygen ([15O]O2) consumption with normal cerebral blood flow ([15O]H2O) is not accompanied by significant uptake of amino acid ([11C]MET) or nucleoside analog ([124I]FIAU).

  • FIGURE 2.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 2.

    For dynamic evaluation of [124I]FIAU influx and washout in cats, ROI analysis focused on organs such as brain (1), heart (2), lung (3), muscle (4), liver (5), stomach and spleen (6), kidney (7), intestine (8), and bladder (9). Stomach and intestine could not be differentiated and were combined into one region. Coregistered FDG PET reveals glucose consumption in brain and heart and excretion of tracer into bladder. Coregistered [15O]H2O PET shows high activities in well-perfused organs such as brain, heart, liver, and kidneys.

  • FIGURE 3.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 3.

    Analysis of quantitative kinetics of [124I]FIAU in various organs of cats early (A) and late (B) after systemic administration of 37 MBq [124I]FIAU. Values are averaged over three animals. Brain showed lowest [124I]FIAU uptake of all organs throughout entire measurement. Brain symbols (•) represent PET frames acquired sequentially. For clarity in graphs, not all symbols for each frame are depicted for other organs. p.i. = after injection.

  • FIGURE 4.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 4.

    Multitracer PET and MRI of 50-y-old male patient with recurrent glioblastoma in left parieto-occipital lobe. T1-weighted MR image shows large subcortical edema within left hemisphere surrounding contrast-enhancing tumor mass. Tumor shows increased [11C]MET uptake (3.1-fold higher than corresponding contralateral temporal region), high glucose consumption (37.3 μmol/100 g/min), and deactivation of surrounding cortex (62.1% of corresponding contralateral region). After systemic administration of 77 MBq [124I]FIAU, dynamic emission sequence over 68 h shows high FIAU accumulation within tumor, scalp, and soft tissue within first hour after injection (p.i.). At later times (8–24 h after injection), substantial FIAU uptake was also observed in peritumoral edematous areas. Washout of FIAU from these regions was slow. Substantial uptake of FIAU in contralateral gray and white matter was not observed.

  • FIGURE 5.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 5.

    Quantitative kinetics of [124I]FIAU in plasma, scalp, tumor, paratumoral area, gray matter, and white matter of 50-y-old male patient with recurrent glioblastoma. Maximum values are reached in tumor and scalp regions within 5–10 min after injection. FIAU washout from tumor and scalp follows similar kinetics. Gray and white matter [124I]FIAU uptake values are always much lower than those in tumor. Symbols represent PET frames acquired sequentially. For clarity in graph, symbols for first 11 frames acquired during first hour after [124I]FIAU injection are omitted. Curves are model fits to data.

  • FIGURE 6.
    • Download figure
    • Open in new tab
    • Download powerpoint
    FIGURE 6.

    Patlak plots of FIAU uptake in various tissues of 50-y-old male patient with recurrent glioblastoma show fast initial uptake of FIAU in tumor and scalp but no FIAU accumulation or trapping in any tissue. Curves are model fits to data.

Tables

  • Figures
    • View popup
    TABLE 1

    Fitted FIAU Rate Constants Generated from Tissue Time–Activity Curves in Various Tissue Regions of Patient with Recurrent Glioblastoma

    RegionK1* (mL/min/g)k2* (min−1)Vb† (%)
    Tumor0.0071 ± 0.00180.009 ± 0.0024.2 ± 1.4
    Paratumor0.00124 ± 0.000010.00157 ± 0.000012.75 ± 0.03
    Scalp0.009 ± 0.0020.014 ± 0.0031.8 ± 1.0
    Gray matter0.0012 ± 0.00050.0041 ± 0.00162.9 ± 0.9
    White matter0.00042 ± 0.000120.0017 ± 0.00053.0 ± 0.8
    • ↵* K1 and k2 refer to forward and reverse transport of FIAU across BBB.

    • ↵† Vb is plasma distribution volume within tissue.

    • Data are presented as mean ± SD from nonlinear least-squares fit.

PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 42, Issue 3
March 1, 2001
  • Table of Contents
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Quantitative Kinetics of [124I]FIAU in Cat and Man
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Quantitative Kinetics of [124I]FIAU in Cat and Man
Andreas Jacobs, Ines Bräunlich, Rudolf Graf, Martin Lercher, Takayuki Sakaki, Jürgen Voges, Volker Hesselmann, Wolfgang Brandau, Klaus Wienhard, Wolf-Dieter Heiss
Journal of Nuclear Medicine Mar 2001, 42 (3) 467-475;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Quantitative Kinetics of [124I]FIAU in Cat and Man
Andreas Jacobs, Ines Bräunlich, Rudolf Graf, Martin Lercher, Takayuki Sakaki, Jürgen Voges, Volker Hesselmann, Wolfgang Brandau, Klaus Wienhard, Wolf-Dieter Heiss
Journal of Nuclear Medicine Mar 2001, 42 (3) 467-475;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Antibody with Infinite Affinity for In Vivo Tracking of Genetically Engineered Lymphocytes
  • Monitoring Bone Marrow Stem Cells with a Reporter Gene System in Experimental Middle Cerebral Artery Occlusion Rat Models
  • A New Acycloguanosine-Specific Supermutant of Herpes Simplex Virus Type 1 Thymidine Kinase Suitable for PET Imaging and Suicide Gene Therapy for Potential Use in Patients Treated with Pyrimidine-Based Cytotoxic Drugs
  • Biodistribution, PET, and Radiation Dosimetry Estimates of HSV-tk Gene Expression Imaging Agent 1-(2'-Deoxy-2'-18F-Fluoro-{beta}-D-Arabinofuranosyl)-5-Iodouracil in Normal Dogs
  • Virus-Associated Tumor Imaging by Induction of Viral Gene Expression
  • Correlation of Na+/I- Symporter Expression and Activity: Implications of Na+/I- Symporter as an Imaging Reporter Gene
  • Imaging bacterial infections with radiolabeled 1-(2'-deoxy-2'-fluoro-{beta}-D-arabinofuranosyl)-5-iodouracil
  • Google Scholar

More in this TOC Section

  • How Sensitive Is the Upper Gastrointestinal Tract to 90Y Radioembolization? A Histologic and Dosimetric Analysis in a Porcine Model
  • 11C-Methionine PET of Myocardial Inflammation in a Rat Model of Experimental Autoimmune Myocarditis
  • Counting Rate Characteristics and Image Distortion in Preclinical PET Imaging During Radiopharmaceutical Therapy
Show more Basic Science Investigations

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire