Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleBasic Science Investigation

Visual Versus Quantitative Assessment of Intratumor 18F-FDG PET Uptake Heterogeneity: Prognostic Value in Non–Small Cell Lung Cancer

Florent Tixier, Mathieu Hatt, Clemence Valla, Vincent Fleury, Corinne Lamour, Safaa Ezzouhri, Pierre Ingrand, Remy Perdrisot, Dimitris Visvikis and Catherine Cheze Le Rest
Journal of Nuclear Medicine June 2014, jnumed.113.133389; DOI: https://doi.org/10.2967/jnumed.113.133389
Florent Tixier
1Nuclear Medicine, CHU Milétrie, Poitiers, France
2INSERM, UMR 1101, LaTIM, Brest, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mathieu Hatt
2INSERM, UMR 1101, LaTIM, Brest, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Clemence Valla
1Nuclear Medicine, CHU Milétrie, Poitiers, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Vincent Fleury
1Nuclear Medicine, CHU Milétrie, Poitiers, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Corinne Lamour
3Department of Oncology, CHU Milétrie, Poitiers, France; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Safaa Ezzouhri
1Nuclear Medicine, CHU Milétrie, Poitiers, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pierre Ingrand
4Epidemiology and Biostatistics, CIC Inserm 1402, CHU Milétrie, Poitiers, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Remy Perdrisot
1Nuclear Medicine, CHU Milétrie, Poitiers, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Dimitris Visvikis
2INSERM, UMR 1101, LaTIM, Brest, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Catherine Cheze Le Rest
1Nuclear Medicine, CHU Milétrie, Poitiers, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF
Loading

Abstract

The goal of this study was to compare visual assessment of intratumor 18F-FDG PET uptake distribution with a textural-features (TF) automated quantification and to establish their respective prognostic value in non–small cell lung cancer (NSCLC). Methods: The study retrospectively included 102 consecutive patients. Only primary tumors were considered. Intratumor heterogeneity was visually scored (3-level scale [Hvisu]) by 2 nuclear medicine physicians. Tumor volumes were automatically delineated, and heterogeneity was quantified with TF. Mean and maximum standardized uptake value were also included. Visual interobserver agreement and correlations with quantitative assessment were evaluated using the κ test and Spearman rank (ρ) coefficient, respectively. Association with overall survival and recurrence-free survival was investigated using the Kaplan–Meier method and Cox regression models. Results: Moderate correlations (0.4 < ρ < 0.6) between TF parameters and Hvisu were observed. Interobserver agreement for Hvisu was moderate (κ = 0.64, discrepancies in 27% of the cases). High standardized uptake value, large metabolic volumes, and high heterogeneity according to TF were associated with poorer overall survival and recurrence-free survival and remained an independent prognostic factor of overall survival with respect to clinical variables. Conclusion: Quantification of 18F-FDG uptake heterogeneity in NSCLC through TF was correlated with visual assessment by experts. However, TF also constitutes an objective heterogeneity quantification, with reduced interobserver variability, and independent prognostic value potentially useful for patient stratification and management.

  • 18FDG-PET/CT
  • heterogeneity
  • textural features
  • prognosis
  • NSCLC

Footnotes

  • Published online ▪▪▪▪▪▪▪▪▪▪▪▪.

  • COPYRIGHT © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  • © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Next
Back to top

In this issue

Journal of Nuclear Medicine: 66 (5)
Journal of Nuclear Medicine
Vol. 66, Issue 5
May 1, 2025
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Visual Versus Quantitative Assessment of Intratumor 18F-FDG PET Uptake Heterogeneity: Prognostic Value in Non–Small Cell Lung Cancer
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Visual Versus Quantitative Assessment of Intratumor 18F-FDG PET Uptake Heterogeneity: Prognostic Value in Non–Small Cell Lung Cancer
Florent Tixier, Mathieu Hatt, Clemence Valla, Vincent Fleury, Corinne Lamour, Safaa Ezzouhri, Pierre Ingrand, Remy Perdrisot, Dimitris Visvikis, Catherine Cheze Le Rest
Journal of Nuclear Medicine Jun 2014, jnumed.113.133389; DOI: 10.2967/jnumed.113.133389

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Visual Versus Quantitative Assessment of Intratumor 18F-FDG PET Uptake Heterogeneity: Prognostic Value in Non–Small Cell Lung Cancer
Florent Tixier, Mathieu Hatt, Clemence Valla, Vincent Fleury, Corinne Lamour, Safaa Ezzouhri, Pierre Ingrand, Remy Perdrisot, Dimitris Visvikis, Catherine Cheze Le Rest
Journal of Nuclear Medicine Jun 2014, jnumed.113.133389; DOI: 10.2967/jnumed.113.133389
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Supplemental
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Heterogeneity in Metastatic Breast Cancer 18F-Fluoroestradiol Uptake: Clinically Actionable, Biologically Illuminating?
  • Understanding Changes in Tumor Texture Indices in PET: A Comparison Between Visual Assessment and Index Values in Simulated and Patient Data
  • Radiomics in PET/CT: More Than Meets the Eye?
  • The Impact of Optimal Respiratory Gating and Image Noise on Evaluation of Intratumor Heterogeneity on 18F-FDG PET Imaging of Lung Cancer
  • Comparison of Tumor Uptake Heterogeneity Characterization Between Static and Parametric 18F-FDG PET Images in Non-Small Cell Lung Cancer
  • Pretreatment 18F-FDG PET Textural Features in Locally Advanced Non-Small Cell Lung Cancer: Secondary Analysis of ACRIN 6668/RTOG 0235
  • Primary tumour standardised uptake value is prognostic in nonsmall cell lung cancer: a multivariate pooled analysis of individual data
  • Impact of Image Reconstruction Settings on Texture Features in 18F-FDG PET
  • Google Scholar

More in this TOC Section

  • Designed Ankyrin Repeat Protein–Mediated Peptide Nucleic Acid–Based Pretargeting: A Proof-of-Principle Study
  • [11C]ZTP-1: An Effective Short-Lived Radioligand for PET of Rat and Monkey Brain Phosphodiesterase Type 4 Subtype B
  • Reduced Renal Uptake of Various Radiopharmaceuticals with Sodium Paraaminohippurate Coadministration in a Rat Model
Show more Basic Science Investigation

Similar Articles

Keywords

  • 18FDG-PET/CT
  • heterogeneity
  • textural features
  • prognosis
  • NSCLC
SNMMI

© 2025 SNMMI

Powered by HighWire