JNM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow An erratum has been published
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gaemperli, O.
Right arrow Articles by Kaufmann, P. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gaemperli, O.
Right arrow Articles by Kaufmann, P. A.
Journal of Nuclear Medicine Vol. 48 No. 5 696-703
© 2007 by Society of Nuclear Medicine

doi: 10.2967/jnumed.106.037606

Clinical Investigation

Cardiac Image Fusion from Stand-Alone SPECT and CT: Clinical Experience

Oliver Gaemperli1, Tiziano Schepis1, Ines Valenta1, Lars Husmann2, Hans Scheffel2, Victor Duerst1, Franz R. Eberli1, Thomas F. Luscher1, Hatem Alkadhi2 and Philipp A. Kaufmann1,3

1 Cardiovascular Center, University Hospital Zurich, Zurich, Switzerland; 2 Institute of Diagnostic Radiology, University Hospital Zurich, Zurich, Switzerland; and 3 Zurich Center for Integrative Human Physiology, University of Zurich, Zurich, Switzerland

Correspondence: For correspondence or reprints contact: Philipp A. Kaufmann, MD, Nuclear Cardiology, Cardiovascular Center, University Hospital Zurich, NUK C 32, Raemistrasse 100, CH-8091 Zurich, Switzerland. E-mail: pak{at}usz.ch


    ABSTRACT
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 CONCLUSION
 References
 
Myocardial perfusion imaging with SPECT (SPECT-MPI) and 64-slice CT angiography (CTA) are both established techniques for the noninvasive evaluation of coronary artery disease (CAD). Three-dimensional (3D) SPECT/CT image fusion may offer an incremental diagnostic value by integrating both sets of information. We report our first clinical experiences with fused 3D SPECT/CT in CAD patients. Methods: Thirty-eight consecutive patients with at least 1 perfusion defect on SPECT-MPI (1-d adenosine stress/rest SPECT with 99mTc-tetrofosmin) and 64-slice CTA were included. 3D volume-rendered fused SPECT/CT images were generated and compared with the findings from the side-by-side analysis with regard to coronary lesion interpretation by assigning the perfusion defects to their corresponding coronary lesion. Results: The fused SPECT/CT images added information on pathophysiologic lesion severity in 27 coronary stenoses (22%) of 12 patients (29%) (P < 0.001). Among 40 equivocal lesions on side-by-side analysis, the fused interpretation confirmed hemodynamic significance in 14 lesions and excluded functional relevance in 10 lesions. In 3 lesions, assignment of perfusion defect and coronary lesion appeared to be reliable on side-by-side analysis but proved to be inaccurate on fused interpretation. Added diagnostic information by SPECT/CT was more commonly found in patients with stenoses of small vessels (P = 0.004) and involvement of diagonal branches (P = 0.01). Conclusion: In addition to being intuitively convincing, 3D SPECT/CT fusion images in CAD may provide added diagnostic information on the functional relevance of coronary artery lesions.

Key Words: myocardial perfusion imaging • SPECT • coronary CT angiography • SPECT/CT fusion • coronary artery disease


    INTRODUCTION
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 CONCLUSION
 References
 
A precise, noninvasive technique for the diagnosis of coronary artery disease (CAD) should provide complementary information on coronary artery anatomy and pathophysiologic lesion severity (14). Although this can be achieved by mental integration of the information from coronary angiography (CA) and SPECT myocardial perfusion imaging (SPECT-MPI), standard myocardial distribution territories correspond in only 50%–60% with the real anatomic coronary tree (5). Several pioneering attempts of software-based image fusion from conventional CA and SPECT-MPI have been paving the way but were not implemented into clinical practice because its invasiveness precluded its use for noninvasive preinterventional decision making (58).

Recently, 64-slice CT angiography (CTA) has emerged as a truthful alternative to conventional CA, with excellent diagnostic accuracy, in selected patients (9,10). Combined with the advancements in fast-processing software for 3-dimensional (3D) reconstructions (11), this has allowed initial promising attempts of purely noninvasive SPECT/CT, directly relating individual myocardial wall territories to the subtending coronary artery (1214).

The increasing interest in cardiac fusion imaging is currently raising the question of its clinical feasibility and usefulness. An evaluation seems all the more pertinent, as the integration of SPECT or PET scanners and high-end CT devices into hybrid scanners will promote the combined use of both techniques in the same patient. Alternatively, software solutions for fusion of SPECT or PET information with CTA may allow the combination of image sets obtained on 2 separate stand-alone scanners (14). The aim of the present study was to evaluate the added clinical value of cardiac 3D fusion imaging over the separate analysis of SPECT-MPI and 64-slice CTA on stand-alone scanners.


    MATERIALS AND METHODS
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 CONCLUSION
 References
 
Study Population
CTA and SPECT-MPI were performed on 180 consecutive patients 2 ± 5 d apart. The reasons for each patient's referral were typical or atypical chest pain, pathologic treadmill test, preoperative risk stratification, or dyspnea. Of the 180 patients, only 38 with at least 1 fixed or reversible perfusion defect on SPECT-MPI were included, as cardiac fusion imaging is unlikely to provide any additional information in patients with normal SPECT-MPI. The study protocol was approved by the local institutional review board, and all patients gave written informed consent before enrollment.

SPECT-MPI
All patients underwent a 1-d electrocardiographically (ECG)-gated stress/rest protocol. A dose of 250–350 MBq 99mTc-tetrofosmin was injected 3 min into the adenosine stress according to clinical practice (15). When contraindications for adenosine were present, dobutamine stress was used (16). This was followed by an injection of 3 times the stress dose at rest as recommended (17). Gated SPECT studies were acquired with a dual-head detector camera (Millenium VG and Hawkeye; GE Healthcare) using standard acquisition parameters as previously reported (1820) and x-ray–based attenuation correction (21,22).

Image analysis was performed using a commercially available software package (Cedars QGS/QPS; Cedars-Sinai Medical Center, Los Angeles, CA) (23), and interpretation with regard to reversible (ischemia) and fixed (scar) defects was performed as previously reported (24). A fixed perfusion defect with normal regional wall motion on gated SPECT was considered an artifact rather than a scar (25). Anterior and septal wall perfusion defects were allocated to the left anterior descending coronary artery (LAD), lateral defects to the left circumflex coronary artery (LCX), and inferior defects to the right coronary artery (RCA) according to current clinical recommendations (26).

64-Slice CTA
CT was performed on a 64-detector CT scanner (LightSpeed VCT; GE Healthcare). First, a low-dose, prospectively ECG-gated native scan of the heart was performed for coronary calcium scoring. Scan parameters for CTA were detector collimation, 64 x 0.625 mm; total z-axis detector coverage, 40 mm; gantry rotation time, 0.35 s; tube voltage, 120 kV; ECG-modulated tube current, 280–750 mA; and pitch, 0.18–0.26, depending on the patient's heart rate. A bolus of 70–100 mL of contrast agent (Ultravist [Iopromide], 370 mg/mL; Schering AG) was continuously injected into an antecubital vein (50–80 mL at 5.0 mL/s, then 20 mL at 3.5 mL/s), and CT data acquisition was initiated as previously reported (18,19). All patients with heart rates of >65 beats per minute (bpm) were pretreated intravenously with 5–15 mg of metoprolol tartrate (Lopresor; Sankyo Pharma AG).

The CTA datasets were analyzed using axial source images, multiplanar reformations, and thin-slab maximum-intensity projections on a remote workstation (Advantage Workstation 4.3; GE Healthcare). The coronary tree was evaluated according to a 15-segment model proposed by the American Heart Association (AHA) (27). The intermediary artery was designated as segment 16, if present, and considered to belong to the LAD. Every bypass graft was counted as an additional segment. Image quality was graded as excellent (no motion artifacts present), good (minor motion artifacts present), moderate (substantial motion artifacts present, but luminal assessment of significant stenoses still possible), heavily calcified (vessel lumen obscured by calcifications), and blurred (only contrast visualization inside the vessel possible) for the whole patient's dataset and for every coronary segment. Coronary lesions were visually assessed, and a diameter stenosis ≥ 50% was considered significant.

Image Fusion
Fusion of stress and rest SPECT-MPI with CTA images was performed on a designated workstation (Advantage workstation 4.3; GE Healthcare) using the CardIQ Fusion software package (GE Healthcare). All details of the fusion process have been extensively described, validated, and reported elsewhere (11). In brief, this software provides tools for optimal alignment of axial source SPECT and CT images using the myocardial outlines of SPECT and CT as landmarks and for SPECT image projection on the left ventricular (LV) epicardial surface. The window presets for the color scale projected on the LV epicardium are adopted from the corresponding separate SPECT images and remain unchanged during the fusion process. Additionally, the fusion software facilitates extraction of the aorta and the coronary vessel tree structure from the surrounding tissue. For better visualization of the septal wall, the right ventricle could be faded away by a cardiac transparency tool.

Conventional CA
Conventional CA was performed according to standard techniques, and the angiograms were evaluated in consensus by 2 experienced interventional cardiologists who were both unaware of the clinical history and the results from SPECT-MPI and CTA. The coronary artery tree was similarly subdivided according to the AHA guidelines (27), and each vessel segment was visually evaluated with regard to vessel border delineation on at least 2 different projections. A diameter stenosis ≥ 50% was considered significant. Coronary artery analysis was performed in all vessels with a diameter down to 1.5 mm, including those vessels distal to complete occlusions.

Side-by-Side Interpretation: SPECT Plus CT
Two experienced nuclear cardiologists analyzed the nonfused SPECT-MPI and CTA images side-by-side with regard to functionally relevant coronary stenoses, and consensus was found in every patient. A lesion in any native or bypass graft vessel associated with a matching perfusion defect in its corresponding myocardial territory was considered functionally relevant. Furthermore, the CTA findings were compared with the results from invasive CA to ascertain CTA diagnostic accuracy. All nonevaluable segments were censored as positive, according to an intention-to-diagnose approach, and were included in the analysis.

Fused Interpretation: SPECT/CT
The fused 3D SPECT/CT image analysis was compared with the side-by-side analysis with regard to coronary lesion interpretation. First, the readers evaluated whether the fused SPECT/CT analysis provided any additional diagnostic information about the anatomic relationship between perfusion defects and coronary vessels. Additional diagnostic information was considered to be present if the fused images (a) modified the initial interpretation with regard to the relationship between the "culprit lesion" and the corresponding defect or (b) increased the diagnostic confidence for intermediate lesions or equivocal defects. Furthermore, a potential clinical utility was evaluated by retrospectively assessing whether the information increment provided by the fused analysis would have changed the patient's management (influence on revascularization strategy and target vessel selection).

Statistical Analysis
Statistical analysis was performed using SPSS Software version 12.0.1 for Windows (SPSS Inc.). All numeric variables are given as mean ± SD. Categoric data are given in percentages. A 2-tailed Student t test was used for comparison of means. The findings from coronary lesion interpretation on side-by-side or fused interpretation were compared by applying the {chi}2 test. The Fisher exact test was used for comparison of the combined noninvasive findings with the target lesion on percutaneous coronary intervention. The results of CTA and conventional CA were compared by calculating the sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) of CTA for the detection of coronary stenoses on CA. Potential predictors for diagnostic increments on lesion interpretation by the fused analysis were determined using univariate and multivariate logistic regression analysis. The regression results are presented as odds ratios (OR) and their respective 95% confidence interval (CI). A 2-sided P value < 0.05 was considered statistically significant for all tests.


    RESULTS
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 CONCLUSION
 References
 
Thirty-eight consecutive patients with at least 1 perfusion defect on SPECT-MPI were included in the study. The mean age of the study population was 67 ± 9 y, and 9 patients were female (24%). Table 1 summarizes each patient's clinical characteristics.


View this table:
[in this window]
[in a new window]

 
TABLE 1 Patient Characteristics (n = 38)

 
SPECT-MPI Findings
SPECT-MPI revealed 17 fixed, 19 reversible, and 7 mixed perfusion defects. Five patients (13%) had perfusion defects in >1 coronary artery territory. The exact location of perfusion defects is listed in Table 2. Twenty-two defects were located in the anterior and septal wall, 12 in the inferior wall, and 9 in the lateral wall.


View this table:
[in this window]
[in a new window]

 
TABLE 2 Results of Nonfused and Fused SPECT/CT Analysis

 
64-Slice CTA Findings
All patients were in stable sinus rhythm. Mean heart rate during the scan was 61 ± 7 bpm. Image quality was excellent in 10 patients (26%), good in 15 patients (39%), moderate in 9 patients (24%), heavily calcified in 2 patients (5%), and blurred in 2 patients (5%). The mean calcium score was 1,029 ± 1,399 Agatston score units. In total, 525 coronary segments in 152 coronary arteries were analyzed. A stenosis ≥ 50% was found in 75 evaluable segments (14%). Eighteen coronary segments (3%) were qualified as blurred, 17 segments (3%) were heavily calcified, and 14 segments (3%) had intracoronary stents that rendered a reliable luminal evaluation impossible. According to an intention-to-diagnose strategy, all nonevaluable segments were censored as positive, resulting in 124 stenosed coronary segments (Table 2). The remaining 401 coronary segments (76%) were normal or showed only insignificant wall alterations.

Comparison of CTA Versus Conventional CA
In 25 of the 38 patients (66%) a conventional CA was performed within 26 ± 25 d of the CTA study. In these 25 patients, 339 coronary segments in 100 coronary arteries were analyzed on CTA. Forty-five segments (13%) showed stenoses ≥ 50% on CTA. Thirty-eight segments (11%) were not evaluable due to blurring (n = 16), heavy calcifications (n = 13), or intracoronary stents (n = 9). On a per-segment basis, sensitivity, specificity, NPV, and PPV of CTA for the detection of stenoses ≥ 50% on CA were 81%, 98%, 97%, and 87%, respectively, when all nonevaluable segments were excluded. For the intention-to-diagnose analysis, the latter were included, resulting in a sensitivity, specificity, NPV, and PPV of 85%, 88%, 97%, and 60%, respectively.

Findings of Side-by-Side Analysis
On side-by-side analysis of SPECT-MPI and CTA, 18 coronary stenoses (15%) were assigned to their corresponding perfusion defect with a high level of confidence (Table 2) and, therefore, were considered functionally relevant (Fig. 1). Conversely, 66 coronary stenoses (53%) were not associated with perfusion defects and, therefore, were classified as hemodynamically irrelevant. The remaining 40 segments with stenoses (32%) (in 17 patients) were considered equivocal, as the side-by-side analysis did not allow exclusion of hemodynamic significance in these segments. In 4 patients no coronary stenoses were found on CTA and this was confirmed later by conventional CA; therefore, the SPECT results were considered false-positive because of either complete left bundle branch block (n = 1) or attenuation artifacts (n = 3).


Figure 1
View larger version (11K):
[in this window]
[in a new window]

 
FIGURE 1.  Interpretation of stenosed coronary segments with regard to hemodynamic significance on side-by-side (white columns) or fused (black columns) analysis. *P < 0.001 for comparison of fused vs. side-by-side analysis ({chi}2 test).

 
Findings of SPECT/CT Fusion
Fusion of CTA and SPECT-MPI was successfully performed in all patients. Of the 40 equivocal coronary lesions on side-by-side analysis, 14 were associated with a perfusion defect in its corresponding coronary artery territory and, therefore, were considered hemodynamically relevant. In contrast, in 10 coronary lesions the fused analysis definitely allowed exclusion of hemodynamic significance. The remaining 16 lesions were 8 pairs of sequential neighboring lesions, for which a clear identification of the culprit lesion must remain inconclusive, although the vessel was reliably identified. In 3 lesions assignment of perfusion defect and coronary lesion appeared to be trustworthy on side-by-side analysis but turned out to be inaccurate on the fused analysis (hemodynamically relevant, n = 2; irrelevant, n = 1; patients 22 and 30). Thus, the fused SPECT/CT interpretation provided added information with regard to 27 lesions in 12 patients and allowed exclusion of a relevant lesion in significantly more segments than the side-by-side analysis (P < 0.001) (Fig. 1). Figures 2–4GoGo show examples of these patients, and an overview of all findings with the different modalities is given in Table 2.


Figure 2
View larger version (102K):
[in this window]
[in a new window]

 
FIGURE 2.  (A) Stress and rest perfusion polar maps of SPECT-MPI study show mixed basal anterolateral defect and reversible inferoapical perfusion defect (arrowheads). (B and D) Fused SPECT/CT images reveal total occlusion of LAD and subtotal occlusion of first diagonal branch (DA1), which are confirmed by conventional CA (C). Anterolateral perfusion defect is caused by lesion of partially calcified small intermediary branch (IM); however, this vessel is not well visualized by CA.

 

Figure 3
View larger version (48K):
[in this window]
[in a new window]

 
FIGURE 3.  (A) Perfusion polar maps at stress (dobutamine stress) and rest show reversible anteroseptal perfusion defect. (B and C) 64-slice CTA revealed myocardial bridging (MB) of mid LAD of >2-cm length and calcified plaque at origin of first diagonal branch (DA). (D) Fused 3D SPECT/CT images could allocate reversible perfusion defect to DA, whereas MB seemed to be hemodynamically insignificant.

 

Figure 4
View larger version (53K):
[in this window]
[in a new window]

 
FIGURE 4.  (A) Perfusion polar maps of SPECT-MPI at stress and rest show largely reversible anteroapical perfusion defect (arrowhead). (B) 3D volume-rendered CTA images show coronary vessel tree with stenosis of mid LAD and proximal stenosis of first diagonal branch (DA1). (C) Fused 3D SPECT/CT images are able to identify DA1 stenosis as functionally relevant lesions. (D) Findings were confirmed by invasive CA.

 
Comparison of Fused and Side-by-Side Analysis for Detection of Coronary Lesions Requiring Revascularization
In 10 (40%) of 25 patients undergoing conventional CA, a percutaneous coronary intervention (PCI) with stent implantation involving the following vessels was performed: LAD (n = 6), diagonal artery (DA) (n = 2), LCX (n = 2), obtuse marginal branch (n = 1), and RCA (n = 2). When patients were evaluated using only side-by-side analysis, a discrepancy was found between the coronary lesion treated as the culprit lesion with PCI and the functionally relevant lesion on initial noninvasive testing in 2 patients (patients 5 and 21). Fused SPECT/CT analysis revealed such a discrepancy in 2 additional patients (patients 4 and 34) with a stenosis of the LAD and DA (on CTA and CA) (Fig. 4) (P = not significant). Although the ischemic perfusion defect could be allocated to a DA using the SPECT/CT fusion, the LAD lesion was treated percutaneously on CA in both patients (Fig. 4).

Predictors of Incremental Diagnostic Information of SPECT/CT Fusion
Patients with incremental diagnostic information on SPECT/CT fusion (n = 12) had significant stenoses in small coronary arteries (2.1 ± 0.5 vs. 3.3 ± 0.7 mm, P < 0.001). Diagonal branches were more commonly involved (83% vs. 35%, P = 0.01), and calcium scores tended to be higher (1,439 ± 1,939 vs. 840 ± 1,060, P = 0.23). Significant predictors (by univariate regression analysis) for incremental diagnostic information of SPECT/CT fusion were the diameter of the culprit vessel (P = 0.004) and the involvement of diagonal branches (P = 0.01) (Table 3). When using multivariate logistic regression, only the former parameter reached the level of statistical significance (OR, 0.018 [95% CI, 0.001–0.944], P = 0.047).


View this table:
[in this window]
[in a new window]

 
TABLE 3 Predictors of Diagnostic Increment Using 3D SPECT/CT Fusion*

 

    DISCUSSION
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 CONCLUSION
 References
 
Our results demonstrate that in almost one third of patients undergoing combined SPECT-MPI and CTA studies, the fused SPECT/CT analysis provided added diagnostic information on pathophysiologic lesion severity not obtained on side-by-side analysis. The incremental value was most pronounced for functionally relevant lesions in distal segments and diagonal branches and in vessels with extensive CAD or heavy calcification on CTA. The individual variance of coronary artery anatomy and the complex disease pattern in these patients allowed correct allocation of perfusion defect and subtending coronary artery only by fusion of SPECT-MPI and CTA.

It is well established that a comprehensive assessment of CAD requires not only morphologic information about coronary artery stenosis location and degree but also functional information on pathophysiologic lesion severity (2,3). Eventually, many factors that cannot fully be assessed with coronary luminology determine whether a given stenosis really induces a myocardial perfusion defect. Therefore, an evaluation of the functional relevance of coronary stenosis is generally recommended to guide further decisions about revascularization strategies (3). Software-based 3D image fusion of SPECT-MPI and CT datasets offers superior diagnostic information with regard to identification of the culprit vessel and increases diagnostic confidence for categorizing intermediate lesions and equivocal perfusion defects. In fact, most of the lesions that were originally found to be equivocal with regard to pathophysiologic severity on side-by-side analysis—as they could not be firmly assigned to a perfusion defect—were classified with high confidence on the fused analysis. Thus, the greatest added value appears to be the firm exclusion of hemodynamic significance of coronary abnormalities seen on CTA, which might help to avoid unnecessary interventional procedures.

However, the clinical usefulness in terms of impact on patients' management of cardiac SPECT/CT fusion may not be as high as expected for several reasons. First, one third of the patients with incremental information by fused SPECT/CT had fixed perfusion defects, which generally would not justify revascularization without evidence of viability, which was not assessed in the present study. Second, SPECT/CT fusion proved to be useful for lesions in distal vessels and side branches with limited prognostic impact, regardless of revascularization strategy (28). Similarly, for small perfusion defects, conservative management may be justified without the need for invasive procedures (29). However, for the treatment of refractory angina in patients with multiple intermediate lesions, image fusion may nevertheless facilitate identification and appropriate revascularization of the culprit lesion.

From a computational perspective, a hardware-based approach to image fusion using hybrid scanners seems superior to a software-based approach, as it permits the acquisition of coregistered anatomic and functional images (30). At a software level, this is achieved through the use of landmark-, surface-, or intensity-based coregistration techniques. Most likely it will depend on the individual setting of each institution to determine the type of approach—that is, software-based fusion or hybrid scanner—that is best tailored for its particular purpose.

Several limitations are noteworthy. As 3D SPECT/CT fusion was analyzed retrospectively, its impact on patient management could not be prospectively assessed. In addition, no true gold standard is available to validate the discrepancies observed between the findings on SPECT/CT and the decision by the interventional cardiologist to revascularize, although the accuracy of the fusion process has been recently documented (11).

Furthermore, conventional CA was only performed in two thirds of the patients. However, in these patients the findings from CTA and CA correlated well and the diagnostic accuracy of the CTA images was within the range of previously published data (9,10). The rate of nonevaluable segments was slightly higher in the present study compared with the latter reports. This finding was due to the relatively high calcium score as a result of the inclusion criteria (perfusion defect), setting them at a high likelihood of CAD. New CT technology may enable scanning of patients with high coronary calcium burden or high heart rates without loss of image quality (31).

The combination of SPECT-MPI with a 99mTc-labeled compound and CTA results in a radiation exposure of 15–25 mSv, comparable to the exposure from a thallium scan. As the fusion per se may increase the information obtained from each separate scan at no additional cost of radiation, its use may be welcomed as an adjunct to SPECT-MPI similar to the introduction of gating.


    CONCLUSION
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 CONCLUSION
 References
 
Software-based 3D cardiac SPECT/CT fusion imaging provides additional information about hemodynamic relevance and facilitates lesion interpretation by allowing exact allocation of perfusion defects to its subtending coronary artery.


    ACKNOWLEDGMENTS
 
We are grateful to Ratko Milovanovic, our deputy chief radiographer, for his excellent technical support. This study was supported by a grant from the Swiss National Science Foundation (grant PP00A-68835) and by a grant from the National Center of Competence in Research, Computer Aided and Image Guided Medical Interventions of the Swiss National Science Foundation.


    FOOTNOTES
 
COPYRIGHT © 2007 by the Society of Nuclear Medicine, Inc.


    References
 TOP
 ABSTRACT
 INTRODUCTION
 MATERIALS AND METHODS
 RESULTS
 DISCUSSION
 CONCLUSION
 References
 

  1. Namdar M, Hany TF, Koepfli P, et al. Integrated PET/CT for the assessment of coronary artery disease: a feasibility study. J Nucl Med. 2005;46:930–935.[Abstract/Free Full Text]
  2. Klocke FJ, Baird MG, Lorell BH, et al. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging: executive summary—a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 Guidelines for the Clinical Use of Cardiac Radionuclide Imaging). Circulation. 2003;108:1404–1418.[Free Full Text]
  3. Silber S, Albertsson P, Aviles FF, et al. Guidelines for percutaneous coronary interventions: the Task Force for Percutaneous Coronary Interventions of the European Society of Cardiology. Eur Heart J. 2005;26:804–847.[Free Full Text]
  4. Smith SC Jr, Feldman TE, Hirshfeld JW Jr, et al. ACC/AHA/SCAI 2005 guideline update for percutaneous coronary intervention: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/SCAI Writing Committee to Update 2001 Guidelines for Percutaneous Coronary Intervention). Circulation. 2006;113:156–175.[Free Full Text]
  5. Schindler TH, Magosaki N, Jeserich M, et al. Fusion imaging: combined visualization of 3D reconstructed coronary artery tree and 3D myocardial scintigraphic image in coronary artery disease. Int J Card Imaging. 1999;15:357–368; discussion, 369–370.[CrossRef][Medline]
  6. Peifer JW, Ezquerra NF, Cooke CD, et al. Visualization of multimodality cardiac imagery. IEEE Trans Biomed Eng. 1990;37:744–756.[CrossRef][Medline]
  7. Nishimura Y, Fukuchi K, Katafuchi T, et al. Superimposed display of coronary artery on gated myocardial perfusion scintigraphy. J Nucl Med. 2004;45:1444–1449.[Abstract/Free Full Text]
  8. Faber TL, Santana CA, Garcia EV, et al. Three-dimensional fusion of coronary arteries with myocardial perfusion distributions: clinical validation. J Nucl Med. 2004;45:745–753.[Abstract/Free Full Text]
  9. Leschka S, Alkadhi H, Plass A, et al. Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J. 2005;26:1482–1487.[Abstract/Free Full Text]
  10. Raff GL, Gallagher MJ, O'Neill WW, Goldstein JA. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol. 2005;46:552–557.[Abstract/Free Full Text]
  11. Gaemperli O, Schepis T, Kalff V, et al. Validation of a new cardiac image fusion software for three-dimensional integration of myocardial perfusion SPECT and stand-alone 64-slice CT angiography. Eur J Nucl Med Mol Imaging. January 24, 2007 [Epub ahead of print].
  12. Nakaura T, Utsunomiya D, Shiraishi S, et al. Three-dimensional cardiac image fusion using new CT angiography and SPECT methods. AJR. 2005;185:1554–1557.[Abstract/Free Full Text]
  13. Nakaura T, Utsunomiya D, Shiraishi S, et al. Images in cardiovascular medicine: fusion imaging between myocardial perfusion single photon emission computed tomography and cardiac computed tomography. Circulation. 2005;112:e47–e48.[Free Full Text]
  14. Gaemperli O, Schepis T, Kaufmann PA. SPECT-CT fusion imaging integrating anatomy and perfusion. Eur Heart J. 2007;28:145.[Free Full Text]
  15. Cerqueira MD, Verani MS, Schwaiger M, Heo J, Iskandrian AS. Safety profile of adenosine stress perfusion imaging: results from the Adenoscan Multicenter Trial Registry. J Am Coll Cardiol. 1994;23:384–389.[Abstract]
  16. Elhendy A, Bax JJ, Poldermans D. Dobutamine stress myocardial perfusion imaging in coronary artery disease. J Nucl Med. 2002;43:1634–1646.[Abstract/Free Full Text]
  17. Hesse B, Tagil K, Cuocolo A, et al. EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology. Eur J Nucl Med Mol Imaging. 2005;32:855–897.[CrossRef][Medline]
  18. Gaemperli O, Schepis T, Koepfli P, et al. Accuracy of 64-slice CT angiography for the detection of functionally relevant coronary stenoses as assessed with myocardial perfusion SPECT. Eur J Nucl Med Mol Imaging. January 12, 2007 [Epub ahead of print].
  19. Schepis T, Gaemperli O, Koepfli P, et al. Comparison of 64-slice CT with gated SPECT for evaluation of left ventricular function. J Nucl Med. 2006;47:1288–1294.[Abstract/Free Full Text]
  20. Schepis T, Gaemperli O, Koepfli P, et al. Use of coronary calcium score scans from stand-alone multislice computed tomography for attenuation correction of myocardial perfusion SPECT. Eur J Nucl Med Mol Imaging. 2007;34:11–19.[CrossRef][Medline]
  21. Koepfli P, Hany TF, Wyss CA, et al. CT attenuation correction for myocardial perfusion quantification using a PET/CT hybrid scanner. J Nucl Med. 2004;45:537–542.[Abstract/Free Full Text]
  22. Fricke H, Fricke E, Weise R, Kammeier A, Lindner O, Burchert W. A method to remove artifacts in attenuation-corrected myocardial perfusion SPECT introduced by misalignment between emission scan and CT-derived attenuation maps. J Nucl Med. 2004;45:1619–1625.[Abstract/Free Full Text]
  23. Germano G, Kavanagh PB, Waechter P, et al. A new algorithm for the quantitation of myocardial perfusion SPECT. I. Technical principles and reproducibility. J Nucl Med. 2000;41:712–719.[Abstract/Free Full Text]
  24. Berman DS, Kiat H, Friedman JD, et al. Separate acquisition rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion single-photon emission computed tomography: a clinical validation study. J Am Coll Cardiol. 1993;22:1455–1464.[Abstract]
  25. Fleischmann S, Koepfli P, Namdar M, Wyss CA, Jenni R, Kaufmann PA. Gated 99mTc-tetrofosmin SPECT for discriminating infarct from artifact in fixed myocardial perfusion defects. J Nucl Med. 2004;45:754–759.[Abstract/Free Full Text]
  26. Cerqueira MD, Weissman NJ, Dilsizian V, et al. Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation. 2002;105:539–542.[Free Full Text]
  27. Austen WG, Edwards JE, Frye RL, et al. A reporting system on patients evaluated for coronary artery disease: report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation. 1975;51:5–40.[Medline]
  28. Gibbons RJ, Abrams J, Chatterjee K, et al. ACC/AHA 2002 guideline update for the management of patients with chronic stable angina: summary article—a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on the Management of Patients with Chronic Stable Angina). J Am Coll Cardiol. 2003;41:159–168.[Free Full Text]
  29. Hachamovitch R, Berman DS, Shaw LJ, et al. Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: differential stratification for risk of cardiac death and myocardial infarction. Circulation. 1998;97:535–543.[Abstract/Free Full Text]
  30. Bax JJ, Beanlands RS, Klocke FJ, et al. Diagnostic and clinical perspectives of fusion imaging in cardiology: Is the total greater than the sum of its parts? Heart. 2007;93:16–22.[Abstract/Free Full Text]
  31. Scheffel H, Alkadhi H, Plass A, et al. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control. Eur Radiol. 2006;16:2739–2747.[CrossRef][Medline]
Received for publication October 25, 2006. Accepted for publication February 12, 2007.


Related articles in JNM:

This Month in JNM

JNM 2007 48: 11a-12a. [Full Text]  



This article has been cited by other articles:


Home page
JNMHome page
M. S. Javadi, R. Lautamaki, J. Merrill, C. Voicu, W. Epley, G. McBride, and F. M. Bengel
Definition of Vascular Territories on Myocardial Perfusion Images by Integration with True Coronary Anatomy: A Hybrid PET/CT Analysis
J. Nucl. Med., February 1, 2010; 51(2): 198 - 203.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
B. A. Herzog, R. R. Buechel, R. Katz, M. Brueckner, L. Husmann, I. A. Burger, A. P. Pazhenkottil, I. Valenta, O. Gaemperli, V. Treyer, et al.
Nuclear Myocardial Perfusion Imaging with a Cadmium-Zinc-Telluride Detector Technique: Optimized Protocol for Scan Time Reduction
J. Nucl. Med., January 1, 2010; 51(1): 46 - 51.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
O. Gaemperli, L. Husmann, T. Schepis, P. Koepfli, I. Valenta, W. Jenni, H. Alkadhi, T. F. Luscher, and P. A. Kaufmann
Coronary CT angiography and myocardial perfusion imaging to detect flow-limiting stenoses: a potential gatekeeper for coronary revascularization?
Eur. Heart J., December 1, 2009; 30(23): 2921 - 2929.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
P. J. Slomka, V. Y. Cheng, D. Dey, J. Woo, A. Ramesh, S. Van Kriekinge, Y. Suzuki, Y. Elad, R. Karlsberg, D. S. Berman, et al.
Quantitative Analysis of Myocardial Perfusion SPECT Anatomically Guided by Coregistered 64-Slice Coronary CT Angiography
J. Nucl. Med., October 1, 2009; 50(10): 1621 - 1630.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
B De Bruyne and J Sarma
The authors' reply:
Heart, May 1, 2009; 95(9): 762 - 762.
[Full Text] [PDF]


Home page
Heart AsiaHome page
T Chua
The evolving role of molecular imaging for coronary artery disease: where do we stand today?
Heart Asia, March 6, 2009; 2009(2): 1 - 5.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
L. Husmann, B. A. Herzog, O. Gaemperli, F. Tatsugami, N. Burkhard, I. Valenta, P. Veit-Haibach, C. A. Wyss, U. Landmesser, and P. A. Kaufmann
Diagnostic accuracy of computed tomography coronary angiography and evaluation of stress-only single-photon emission computed tomography/computed tomography hybrid imaging: comparison of prospective electrocardiogram-triggering vs. retrospective gating
Eur. Heart J., March 1, 2009; 30(5): 600 - 607.
[Abstract] [Full Text] [PDF]


Home page
ESC Textbook of Cardiovascular MedicineHome page
P. A. Kaufmann, P. G. Camici, and S. R. Underwood
CHAPTER 7 Nuclear Cardiology
ESC Textbook of Cardiovascular Medicine, January 1, 2009; 2(1): med-9780199566990-chapter - med-9780199566990-chapter.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
A. K. Buck, S. Nekolla, S. Ziegler, A. Beer, B. J. Krause, K. Herrmann, K. Scheidhauer, H.-J. Wester, E. J. Rummeny, M. Schwaiger, et al.
SPECT/CT
J. Nucl. Med., August 1, 2008; 49(8): 1305 - 1319.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
B. Bybel, R. C. Brunken, F. P. DiFilippo, D. R. Neumann, G. Wu, and M. D. Cerqueira
SPECT/CT Imaging: Clinical Utility of an Emerging Technology1
RadioGraphics, July 1, 2008; 28(4): 1097 - 1113.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
J. D Schuijf and J. J Bax
CT angiography: an alternative to nuclear perfusion imaging?
Heart, March 1, 2008; 94(3): 255 - 257.
[Full Text] [PDF]


Home page
Eur Heart JHome page
L. Husmann, I. Valenta, O. Gaemperli, O. Adda, V. Treyer, C. A. Wyss, P. Veit-Haibach, F. Tatsugami, G. K. von Schulthess, and P. A. Kaufmann
Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
Eur. Heart J., January 2, 2008; 29(2): 191 - 197.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow An erratum has been published
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Related articles in JNM
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gaemperli, O.
Right arrow Articles by Kaufmann, P. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gaemperli, O.
Right arrow Articles by Kaufmann, P. A.


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH RSS TABLE OF CONTENTS
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY THE JOURNAL OF NUCLEAR MEDICINE