Clinical Investigations |
1 Department of Cardiology, University of Vienna, Vienna, Austria
2 Department of Nuclear Medicine, University of Vienna, Vienna, Austria
3 Department of Medical Computer Sciences, University of Vienna, Vienna, Austria
4 Third Department of Internal Medicine, General Hospital, St. Poelten, Austria
5 Rudolfinerhaus, Vienna, Austria
This study presents and evaluates a model-based image analysis method to calculate from gated cardiac 18F-FDG PET images diastolic and systolic volumes, ejection fraction, and myocardial mass of the left ventricle. The accuracy of these estimates was delineated using measurements obtained by MRI, which was considered the reference standard because of its high spatial resolution. Methods: Twenty patients (18 men, 2 women; mean age ± SD, 59 ± 12 y) underwent electrocardiography-gated cardiac PET and MRI to acquire a set of systolic and diastolic short-axis images covering the heart from apex to base. For PET images, left ventricular radius and wall thickness were estimated by model-based nonlinear regression analysis applied to the observed tracer concentration along radial rays. Endocardial and epicardial contours were derived from these estimates, and left ventricular volumes, ejection fraction, and myocardial mass were calculated. For MR images, an expert manually drew contours. Results: Left ventricular volumes by PET and MRI were 101 ± 60 mL and 112 ± 93 mL, respectively, for end-systolic volume and 170 ± 68 mL and 189 ± 99 mL, respectively, for end-diastolic volume. Ejection fraction was 44% ± 13% by PET and 46% ± 18% by MRI. The left ventricular mass by PET and MRI was 196 ± 44 g and 200 ± 46 g, respectively. PET and MRI measurements were not statistically significant. A significant correlation was observed between PET and MRI for calculation of end-systolic volumes (r = 0.93, SEE = 23.4, P < 0.0001), end-diastolic volumes (r = 0.92, SEE = 26.7, P < 0.0001), ejection fraction (r = 0.85, SEE = 7.4, P < 0.0001), and left ventricular mass (r = 0.75, SEE = 29.6, P < 0.001). Conclusion: Model-based analysis of gated cardiac PET images permits an accurate assessment of left ventricular volumes, ejection fraction, and myocardial mass. Cardiac PET may thus offer a near-simultaneous assessment of myocardial perfusion, metabolism, and contractile function.
Key Words: cardiac PET electrocardiography-gated acquisition model-based image analysis left ventricular function
This article has been cited by other articles:
![]() |
A. Khorsand, S. Graf, H. Eidherr, W. Wadsak, K. Kletter, H. Sochor, E. Schuster, and G. Porenta Gated Cardiac 13N-NH3 PET for Assessment of Left Ventricular Volumes, Mass, and Ejection Fraction: Comparison with Electrocardiography-Gated 18F-FDG PET J. Nucl. Med., December 1, 2005; 46(12): 2009 - 2013. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | RSS | TABLE OF CONTENTS |
| JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY | THE JOURNAL OF NUCLEAR MEDICINE |