Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportGeneral Clinical Specialties Track

CT-based 3D quantification of relative pulmonary lobe perfusion from SPECT in preoperative lung cancer patients: Comparing a manual and a semi-automatic approach

Daniela Knollmann, Jerome Avondo, Andreas Meyer and Wolfgang Schaefer
Journal of Nuclear Medicine May 2016, 57 (supplement 2) 1731;
Daniela Knollmann
2Kliniken Maria Hilf Moenchengladbach Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jerome Avondo
1Hermes Medical Solutions Grayslake IL United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Andreas Meyer
4Pneumology Krankenhaus Franziskushaus Moenchengladbach Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Wolfgang Schaefer
3Krankenhaus Franziskushaus Moenchengladbach Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

1731

Objectives Quantification of relative pulmonary lobar perfusion using scintigraphy is an established procedure to estimate the expected lung function after pulmonary surgery e.g. in bronchial carcinoma. Using SPECT-CT and a 3D-technique, exact pulmonary lobe perfusion fraction can be calculated based on patient anatomy and not only estimated. In a previous study we showed that a 3D-technique based on a time-consuming manual segmentation of the pulmonary lobes using the CT with thereafter VOI transfer to the perfusion SPECT studies produced distinctly different results compared to the old fashioned planar perfusion approach using rectangular ROIs projected onto the anterior and posterior views. Recently a commercial software package “HERMES Hybrid 3D - Lung Lobe Quantification” was introduced, which allows a quick semi-automatic segmentation of lung CTs with automatic transfer of the resulting VOIs to the corresponding perfusion SPECT-CT study and direct calculation of the relative lobar perfusion fraction. The aim of our study was to compare the results of the time-consuming manual segmentation approach (man) with the newer semi-automatic algorithm (semi) in a preoperative setting in lung cancer patients with borderline lung function.

Methods 30 lung cancer patients referred to routine pre-operative relative lobar perfusion quantification were included. Perfusion SPECT-CT (low-dose-CT) was done p.i. of about 150 MBq Tc-99m-MAA (SymbiaT, Siemens). Ventilation SPECT was done before perfusion SPECT to exclude paraneoplastic PE. An iterative Flash3D algorithm was used to reconstruct the SPECT data. The manual 3D segmentation approach was based on the low-doseCT using PMOD, with the resulting VOIs transferred to the coregistered perfusion SPECT data in order to calculate the relative lobar perfusion fractions. The semi-automatic approach used “HERMES Hybrid 3D - Lung Lobe Quantification” to produce relative lobar perfusion fractions based on the matched low-doseCT and diagnostic CT (a diagnostic CT is available in virtually all patients with lung cancer). A correlation analysis of the manual vs. semi-automatic results was done

Results The semi-automatic approach took 5-10 minutes for a complete evaluation whereas the manual segmentation and calculation took about 45 minutes. Relative lobar perfusion values were in lung cancer patients quite similar for both approaches: right upper lobe 14.8±6.6% (man) vs 16.5±8.5% (semi), middle lobe 13.7±5.0% (man) vs 11.6±4.9% (semi), right lower lobe 24.6±7.6% (man) vs 24.8±9.9% (semi), left upper lobe 24.0±8.4% (man) vs 24.0±9.0% (semi), left lower lobe 22.9±5.7% (man) vs 22.9±6.4% (semi). When correlating all relative perfusion values the slope of the regression line (semi-automatic vs. manual) was 1.05 with a correlation coefficient of 0.92.

Conclusions Excellent correlation was found for the relative lobar perfusion values resulting from the semi-automatic approach using “HERMES Hybrid 3D - Lung Lobe Quantification” and the manual approach using PMOD. Therefore, the much more accurate 3D-technique can now overcome the old fashioned planar method without time-consuming manual analysis. Hence the 3D-approach is now suitable for routine use. In larger clinical trials, it has to be tested whether there are prognostic differences between both 3D-approaches, but taking the good concordance in mind we do not believe so.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 57, Issue supplement 2
May 1, 2016
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
CT-based 3D quantification of relative pulmonary lobe perfusion from SPECT in preoperative lung cancer patients: Comparing a manual and a semi-automatic approach
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
CT-based 3D quantification of relative pulmonary lobe perfusion from SPECT in preoperative lung cancer patients: Comparing a manual and a semi-automatic approach
Daniela Knollmann, Jerome Avondo, Andreas Meyer, Wolfgang Schaefer
Journal of Nuclear Medicine May 2016, 57 (supplement 2) 1731;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
CT-based 3D quantification of relative pulmonary lobe perfusion from SPECT in preoperative lung cancer patients: Comparing a manual and a semi-automatic approach
Daniela Knollmann, Jerome Avondo, Andreas Meyer, Wolfgang Schaefer
Journal of Nuclear Medicine May 2016, 57 (supplement 2) 1731;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

General Clinical Specialties Track

  • Quantitative Evaluation of Parathyroid Adenoma and Hyperplasia in Reference to Thyroid using Tc-99m MIBI SPECT/CT
  • A primitive study for clinical application of 18F-AlF-NOTA-octreotide PET/CT in combination with 18F-FDG PET/CT for imaging neuroendocrine neoplasms
  • Role of 18F-FDG PET/CT in detection of disease burden and response assessment in patients with myeloid sarcoma
Show more General Clinical Specialties Track

MTA II: Pulmonary Posters

  • SUVmean of background lung in FDG-PET/CT provides clinical information and prognostic stratification in interstitial lung disease
  • Early Evaluation of the Chemosensitivity in a Rabbit Localized and Solitary VX2 Lung Cancer Model With 18F-FDG PET/CT
Show more MTA II: Pulmonary Posters

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire