Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportCardiovascular

Assessment of natriuretic peptide clearance receptor (NPR-C) targeted nanoparticles for atherosclerosis PET imaging

Hannah Luehmann, Eric Pressly, Lisa Detering, Zulfia Kisrieva-Ware, Richard Laforest, Richard Pierce, Craig Hawker, Robert Gropler, Yongjian Liu and Pamela Woodard
Journal of Nuclear Medicine May 2014, 55 (supplement 1) 461;
Hannah Luehmann
1Radiology, Washington University, St. Louis, MO
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Eric Pressly
3Chemistry, University of California Santa Barbara, Santa Barbara, CA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Lisa Detering
1Radiology, Washington University, St. Louis, MO
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Zulfia Kisrieva-Ware
1Radiology, Washington University, St. Louis, MO
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Richard Laforest
1Radiology, Washington University, St. Louis, MO
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Richard Pierce
2Internal Medicine, Washington University, St. Louis, MO
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Craig Hawker
3Chemistry, University of California Santa Barbara, Santa Barbara, CA
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Robert Gropler
1Radiology, Washington University, St. Louis, MO
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yongjian Liu
1Radiology, Washington University, St. Louis, MO
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pamela Woodard
1Radiology, Washington University, St. Louis, MO
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

461

Objectives The goal of this study was to assess the imaging capability of C-type atrial natriuretic factor (CANF) conjugated nanoparticles to target the natriuretic peptide clearance receptor (NPR-C) up-regulated in a clinically relevant model of atherosclerosis.

Methods CANF-Comb nanoparticles were prepared through modular construction with controlled functionalities for PET imaging of NPR-C receptor via radiolabeling with 64Cu. The efficiency of the construct was demonstrated in ApoE-/- mice fed a high cholesterol diet to form spontaneous atherosclerotic lesions in the aorta. Age-matched C57BL6 mice fed a normal diet were the control animals. PET/CT imaging was performed at multiple time points to follow the progression of disease. The aortic arteries were collected post scan for histopathological examination and RT-PCR analysis. Blocking studies were also performed to confirm targeting specificity.

Results PET studies show greater uptake of 64Cu-CANF-Comb in the ApoE-/- mice compared to the C57BL6 mice on 18 weeks of diet with standard uptake values (SUV) of 5.35 (SD = 1.01) and 3.30 (SD = 1.13), respectively (P < 0.03, n = 6). PET competitive blocking studies significantly reduced the tracer uptake (SUV = 3.94, SD = 0.25, P < 0.02, n = 6) and confirmed receptor-mediated tracer uptake in the plaque. Longitudinal imaging studies showed that NPR-C was up-regulated at an early stage of plaque development, which was also confirmed by quantitative RT-PCR analysis.

Conclusions PET/CT imaging showed the capability of the 64Cu-CANF-Comb to image plaque in a pre-clinical model of spontaneous atherosclerosis development. Its in vivo pharmacokinetics and plaque uptake indicate translational potential as a PET imaging agent for early-stage atherosclerosis in humans.

Research Support This work is supported by the National Institutes of Health as a Program of Excellence in Nanotechnology (HHSN268201000046C).

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 55, Issue supplement 1
May 2014
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Assessment of natriuretic peptide clearance receptor (NPR-C) targeted nanoparticles for atherosclerosis PET imaging
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Assessment of natriuretic peptide clearance receptor (NPR-C) targeted nanoparticles for atherosclerosis PET imaging
Hannah Luehmann, Eric Pressly, Lisa Detering, Zulfia Kisrieva-Ware, Richard Laforest, Richard Pierce, Craig Hawker, Robert Gropler, Yongjian Liu, Pamela Woodard
Journal of Nuclear Medicine May 2014, 55 (supplement 1) 461;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Assessment of natriuretic peptide clearance receptor (NPR-C) targeted nanoparticles for atherosclerosis PET imaging
Hannah Luehmann, Eric Pressly, Lisa Detering, Zulfia Kisrieva-Ware, Richard Laforest, Richard Pierce, Craig Hawker, Robert Gropler, Yongjian Liu, Pamela Woodard
Journal of Nuclear Medicine May 2014, 55 (supplement 1) 461;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Cardiovascular

  • Cardiac β-Adrenergic Receptor Downregulation, Evaluated by Cardiac PET, in Chronotropic Incompetence
  • Diagnostic Performance of PET Versus SPECT Myocardial Perfusion Imaging in Patients with Smaller Left Ventricles: A Substudy of the 18F-Flurpiridaz Phase III Clinical Trial
  • Quantification of Macrophage-Driven Inflammation During Myocardial Infarction with 18F-LW223, a Novel TSPO Radiotracer with Binding Independent of the rs6971 Human Polymorphism
Show more Cardiovascular

Vascular Imaging

  • Evaluation and comparison of [18F]FDG and [11C]choline as atherosclerosis imaging agents
  • Targeting P-selectin by Gallium-68 labelled Fucoidan for non-invasive characterization of vulnerable plaques in apoE-deficient mice: Correlation with 17.6 T MRI
  • Quantitative spectral x-ray molecular CT of bio-markers in excised vulnerable atheroma
Show more Vascular Imaging

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire