Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportRadiopharmaceutical Chemistry: Special Sessions

High-throughput screening of molecular imaging agents using MicroPET

M. Karen Gagnon, Jan Marik, Sven Hausner, Craig Abbey and Julie Sutcliffe
Journal of Nuclear Medicine May 2007, 48 (supplement 2) 23P;
M. Karen Gagnon
1Biomedical Engineering, UCDavis, Davis, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jan Marik
1Biomedical Engineering, UCDavis, Davis, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sven Hausner
1Biomedical Engineering, UCDavis, Davis, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Craig Abbey
1Biomedical Engineering, UCDavis, Davis, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Julie Sutcliffe
1Biomedical Engineering, UCDavis, Davis, California
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

77

Objectives: In vitro screening of molecular imaging agents isolated from chemical libraries can be used to identify new compounds for imaging. However, several promising compounds often remain even after stringent in vitro testing and only the most promising compound is selected for in vivo evaluation. While in vitro screening identifies promising lead compounds, in vitro success does not always correspond to in vivo success. Here we report the implementation of a high-throughput approach for the in vivo evaluation of a large number of 18F-radiolabeled peptides as molecular imaging agents. Methods: The one-bead-one-compound technique was used to create a library of peptides to target the αvβ6 integrin. After screening using a stringent on-bead assay, the identified sequences were subjected to ELISAs against the αvβ6 integrin. The sequences with the highest affinity and/or selectivity were chosen for in vivo evaluation. To this end, 4 peptides per day were radiolabeled with 4-[18F]fluorobenzoic acid (18F]FBA) using solid-phase radiolabeling techniques.1 Each peptide was injected concomitantly via a tail vein catheter into 2 nude mice bearing both an αvβ6 positive and an αvβ6 negative tumor. The mice were positioned side by side on the scanner bed and shared the same heating console, while the anesthesia for each mouse was individually controlled. The mice were scanned for 1 hour following injection, and again at 3 hours for 15 minutes. Following this protocol, 4 different peptides were evaluated in vivo in 2 mice at 2 different time points per day. Results: A total of 43 peptides were radiolabeled with [18F]FBA and evaluated in vivo over the course of 11 consecutive days. Each peptide was evaluated in 2 mice concomitantly injected and scanned at 2 time points using MicroPET. The 4 most promising compounds identified from the in vivo screen would not have been evaluated based solely on in vitro analysis. Conclusions: The feasibility of using MicroPET for high-throughput in vivo studies was demonstrated. Lead compounds that target the αvβ6 integrin were identified from this in vivo screen. 1Sutcliffe-Goulden JL, et. al.(2002). Rapid solid phase synthesis and biodistribution of 18F-labelled linear peptides. Eur J Nucl Med Mol Imaging;29:754-759.

Research Support (if any): NIH R21CA107792

  • Society of Nuclear Medicine, Inc.
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 48, Issue supplement 2
May 1, 2007
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
High-throughput screening of molecular imaging agents using MicroPET
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
High-throughput screening of molecular imaging agents using MicroPET
M. Karen Gagnon, Jan Marik, Sven Hausner, Craig Abbey, Julie Sutcliffe
Journal of Nuclear Medicine May 2007, 48 (supplement 2) 23P;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
High-throughput screening of molecular imaging agents using MicroPET
M. Karen Gagnon, Jan Marik, Sven Hausner, Craig Abbey, Julie Sutcliffe
Journal of Nuclear Medicine May 2007, 48 (supplement 2) 23P;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Radiopharmaceutical Chemistry: Special Sessions

  • Novel C-5 [18F]fluoroalkylated nucleosides for PET imaging of HSV1-tk gene expression
  • A new method for radiosynthesis of 11C-carbamate groups and its application for a highly efficient synthesis of the kappa-opioid receptor tracer 11CGR103545
  • γ Imaging of 111In-labeled monoclonal antibody 3H11 in colon cancer animal model
Show more Radiopharmaceutical Chemistry: Special Sessions

Radiopharmaceutical Sciences Council Young Investigator Award Symposium

  • Novel C-5 [18F]fluoroalkylated nucleosides for PET imaging of HSV1-tk gene expression
  • A new method for radiosynthesis of 11C-carbamate groups and its application for a highly efficient synthesis of the kappa-opioid receptor tracer 11CGR103545
  • γ Imaging of 111In-labeled monoclonal antibody 3H11 in colon cancer animal model
Show more Radiopharmaceutical Sciences Council Young Investigator Award Symposium

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire