Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportGeneral Clinical Specialties: Musculoskeletal

Improved resolution of bone scintigraphy by using an iterative deconvolution technique (IDT): Effects on visualization and interpretation of focal lesions

Reza Elahi, Eva Henning, Juergen Kupferschlaeger, Mehmet Oeksuez, Helmut Dittmann and Roland Bares
Journal of Nuclear Medicine May 2007, 48 (supplement 2) 14P;
Reza Elahi
1Nuclear Medicine, University Hospital Tuebingen, Tuebingen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Eva Henning
1Nuclear Medicine, University Hospital Tuebingen, Tuebingen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Juergen Kupferschlaeger
1Nuclear Medicine, University Hospital Tuebingen, Tuebingen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mehmet Oeksuez
1Nuclear Medicine, University Hospital Tuebingen, Tuebingen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Helmut Dittmann
1Nuclear Medicine, University Hospital Tuebingen, Tuebingen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Roland Bares
1Nuclear Medicine, University Hospital Tuebingen, Tuebingen, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

45

Objectives: Deconvolution of planar scintigrams can improve image quality with respect to contrast and resolution. We used an MLEM based iterative deconvolution technique which was developed and implemented in our department. Aim of this study was to analyze whether IDT allows for improved visualization and interpretation of focal lesions on whole body bone scans (WBS). Methods: 77 WBS (49 because of oncological, 28 because of rheumatological diseases) were included into the study. Conventional images and images processed with IDT were re-analyzed separately with regard to visualization (v-score (VS): on a 0 to 5 scale, 0 being not visible) and interpretation (i-score (IS): 0 to 2 scale, 0 being unclear) of bone lesions. Lesions were classified into 5 different types (defects, focally increased uptake of small, moderate and large size, diffuse uptake) and grouped according to their anatomical localisation (skull, vertebral column, ribs and sternum, pelvis, peripheral skeleton: articular or non-articular lesions). For each type of lesions we evaluated whether IDT improves VS and/or IS, or if it changes the clinical diagnosis (benign vs. malignant). Results: 365 lesions were identified. IDT improved the VS for 212/365 (55%) lesions, in 124 (34%) for more than one point. IS was improved for 211/365 (55%) lesions. Both VS and IS were particularly improved for small lesions (VS: 88.1% / IS: 82.1%), focal lesions (VS: 70.1% / IS: 69.5%), large lesions (VS: 51% / IS: 53.7%) and for the following localizations: vertebral column (VS: 65.4% / IS: 61.5%), articular peripheral skeleton (VS: 63.7% / IS: 67.2%), and pelvis (VS: 64.3% / IS: 62%). Improvement of VS/IS of at least 40% was observed for most of the other types and localisation as well except for diffuse lesions (VS: 17%, IS: 16%). 58 new lesions in 23 patients (12 of them obese) were detected in scans reprocessed by IDT. Clinical diagnosis was changed in 7/77 patients. Conclusions: IDT improves image quality of conventional bone scans, in particular visualization and interpretation of small focal lesions in obese patients.

  • Society of Nuclear Medicine, Inc.
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 48, Issue supplement 2
May 1, 2007
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Improved resolution of bone scintigraphy by using an iterative deconvolution technique (IDT): Effects on visualization and interpretation of focal lesions
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Improved resolution of bone scintigraphy by using an iterative deconvolution technique (IDT): Effects on visualization and interpretation of focal lesions
Reza Elahi, Eva Henning, Juergen Kupferschlaeger, Mehmet Oeksuez, Helmut Dittmann, Roland Bares
Journal of Nuclear Medicine May 2007, 48 (supplement 2) 14P;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Improved resolution of bone scintigraphy by using an iterative deconvolution technique (IDT): Effects on visualization and interpretation of focal lesions
Reza Elahi, Eva Henning, Juergen Kupferschlaeger, Mehmet Oeksuez, Helmut Dittmann, Roland Bares
Journal of Nuclear Medicine May 2007, 48 (supplement 2) 14P;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

General Clinical Specialties: Musculoskeletal

  • Bone mineral density in adult patients with major thalassemia
  • In-vivo evaluation of Lu-177 hydroxyapatite for application in radiation synovectomy of digital joints
  • The prevalence of abnormal joint uptake in the lower extremities on 18F-FDG PET/CT in relation to patient’s age and BMI.
Show more General Clinical Specialties: Musculoskeletal

Infection and Improved Scintigraphic Techniques

  • 99mTc-Infliximab-scintigraphy for the demonstration of tumor necrosis factor alpha in patients with rheumatoid and psoriatic arthritis
  • Hip arthroplasty failure in patients with a cemented femoral component: Significance of a normal bone scan
  • Reduction in scan duration or injected dose in planar bone scintigraphy enabled by Pixon® post-processing
Show more Infection and Improved Scintigraphic Techniques

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire