Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportPoster - PhysicianPharm

Dual-isotope procedures using 3D-ring CZT StarGuide SPECT/CT: first clinical results from parathyroid acquisitions and head-to-head comparison with a conventional camera

Matthieu BAILLY, Gilles LE ROUZIC, Rani Zananiri and Gilles METRARD
Journal of Nuclear Medicine May 2021, 62 (supplement 1) 1127;
Matthieu BAILLY
1Nuclear Medicine CHR Orleans Orleans France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Gilles LE ROUZIC
1Nuclear Medicine CHR Orleans Orleans France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Rani Zananiri
2GE Healthcare Haifa Israel
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Gilles METRARD
1Nuclear Medicine CHR Orleans Orleans France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

1127

Aim: The StarGuide 3D-ring CZT-camera (GE Healthcare, Haifa, Israel) is equipped with 12 swiveling high-resolution CZT detectors and a CT in a hybrid system. This system allows dual isotope acquisitions. In this preliminary work, we report the first clinical examples of parathyroid scintigraphy with the new StarGuide 360-degree CZT SPECT/CT system, compared to a conventional camera.

Methods: 5 patients (2 men; 3 women) referred for parathyroid scintigraphy were double scanned on a conventional camera (Discovery 670 Pro, GE Healthcare, Haifa, Israel) and on the new StarGuide CZT system, after mean injection of 12.8 MBq 123-iodine and 734 MBq of 99mTc-MIBI. SPECT duration was 22 and 15 minutes respectively for the conventional and the StarGuide systems. Patients acquired spectra on the conventional camera and on StarGuide were compared. Energy Resolution for 99mTc was calculated and expressed as the ratio of FWHM to the peak. Spill-over of 99mTc into the 123I energy window was defined as the percentage of 99mTc counts in the 123I energy window. Clinical data were visually analyzed by 3 board-certified Nuclear Medicine Physicians to score image quality, resolution and final diagnosis.

Results: StarGuide expressed a significant improvement in energy resolution compared to the conventional camera, with 5.1% versus 9.5% at 140.5keV respectively for StarGuide and the conventional system. Spillover of 99mTc towards the 123I imaging window in StarGuide was less than 2.5%, resulting in a nearly pure 123I thyroid image, whereas it was ~85% on the conventional camera. Using a 5-point Likert scale, StarGuide mean image quality and resolution were respectively 4.3 and 4.4. The new system provided clearer delineation of parathyroid uptake, especially in pathological patients, compared to the conventional camera and a better image quality for 123I showing only thyroid gland without background. For all raters and patients, StarGuide provided same or better images and information relative to the reference camera.

Conclusions: Using StarGuide, 3D-ring CZT parathyroid dual isotope SPECT acquisitions become feasible in short acquisition time, with a great image quality and energy resolution, and also in some cases better clinical information relative to the conventional SPECT/CT camera.

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 62, Issue supplement 1
May 1, 2021
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Dual-isotope procedures using 3D-ring CZT StarGuide SPECT/CT: first clinical results from parathyroid acquisitions and head-to-head comparison with a conventional camera
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Dual-isotope procedures using 3D-ring CZT StarGuide SPECT/CT: first clinical results from parathyroid acquisitions and head-to-head comparison with a conventional camera
Matthieu BAILLY, Gilles LE ROUZIC, Rani Zananiri, Gilles METRARD
Journal of Nuclear Medicine May 2021, 62 (supplement 1) 1127;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Dual-isotope procedures using 3D-ring CZT StarGuide SPECT/CT: first clinical results from parathyroid acquisitions and head-to-head comparison with a conventional camera
Matthieu BAILLY, Gilles LE ROUZIC, Rani Zananiri, Gilles METRARD
Journal of Nuclear Medicine May 2021, 62 (supplement 1) 1127;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Poster - PhysicianPharm

  • Preliminary result of Texture Analysis on prediction of overall outcome of neuroendocrine tumors based on pre-therapy heterogeneity of somatostatin receptors on 68Ga Dotatate PET/CT scans.
  • Artificial Intelligence based segmental quantification of pulmonary perfusion for pre-transplant workup.
  • Comparison of stress myocardial Flow Response using regadenoson and dipyridamole in SPECT
Show more Poster - PhysicianPharm

PIDS-Instrumentation

  • Design and Development of an MRI Compatible Human Brain PET Scanner by Using Dual-ended Readout Detectors
  • First prototype of a novel dual round-edge detector arrangement for breast PET imaging
  • Comparison of the Physical Performance of two Siemens Biograph Vision PET models with Extended Axial Field-Of-View Using Sparse Detector Blocks
Show more PIDS-Instrumentation

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire