Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
EditorialCovid-19 Commentaries
Open Access

Diagnostic Evaluation of Pulmonary Embolism During the COVID-19 Pandemic

Lionel S. Zuckier, Renée M. Moadel, Linda B. Haramati and Leonard M. Freeman
Journal of Nuclear Medicine May 2020, 61 (5) 630-631; DOI: https://doi.org/10.2967/jnumed.120.245571
Lionel S. Zuckier
1Division of Nuclear Medicine, Department of Radiology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, New York; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Renée M. Moadel
1Division of Nuclear Medicine, Department of Radiology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, New York; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Linda B. Haramati
2Division of Thoracic Radiology, Departments of Radiology and Medicine, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, New York
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Leonard M. Freeman
1Division of Nuclear Medicine, Department of Radiology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, New York; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

The rapid emergence of the COVID-19 pandemic has altered the risk–benefit calculus of many activities, including the practice of medicine. COVID-19 is caused by a single-strand RNA virus, SARS-CoV-2, belonging to the Coronaviridae family. The virus is known to infect the upper respiratory tract and can spread through aerosolization of upper airway secretions in infected patients. Indeed, current online guidance from the U.S. Centers for Disease Control and Prevention recommends that when performing aerosol-generating procedures, health-care personnel in the room should optimally wear an N95 or higher level respirator, eye protection, gloves, and a gown.

It is, therefore, crucial to identify studies that have a potential to result in aerosolized secretions and adjust to mitigate risk. The main candidate study for this intervention in nuclear medicine is ventilation/perfusion scintigraphy for the detection of pulmonary embolism. The population of patients suspected of having pulmonary embolism have overlapping symptoms with individuals who are infected with COVID-19. The typical protocol for lung scintigraphy entails performance of a low-dose ventilation examination followed immediately thereafter by a higher dose perfusion study. Previous literature has documented a small degree of radioactive contamination produced by leakage of the aerosol from the closed delivery system into the room (1,2), with the potential for expired air and aerosolized secretions to contaminate personnel within the imaging suite. In addition, patients frequently cough after inhalation of a radiopharmaceutical, which may further expose nuclear medicine workers to aerosolized secretions. Although these contamination studies were performed using specific DTPA aerosol systems, various issues of leakage, aerosolization, and coughing are potentially common to all techniques of ventilation scanning, including those using radiogases, and raise concern. One potential response would be to equip technologists in the imaging suite with adequate respiratory equipment such as N-95 masks when ventilation studies are performed; however, appropriate personal protection equipment may be in short supply and not easily procured. Furthermore, after suspected aerosolization, the γ-camera and imaging suite must undergo a decontamination process, significantly retarding patient throughput. We believe that under these circumstances, it is preferable to shift to a diagnostic algorithm that obviates ventilation (3–5), thereby minimizing potential for aerosolization. One such algorithm is indicated in Figure 1.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Updated diagnostic algorithm for evaluation of pulmonary embolism, which minimizes performance of ventilation studies. Green box represents perfusion scintigraphy, whereas red dotted box encloses alternate diagnostic examinations that are performed due to prior radiographic opacity (red solid arrow) or indeterminate scintigraphy (red dotted arrow).

An initial step in reducing the number of ventilation scans is to rigorously assess pretest probability and limit imaging to appropriate patients. In this regard, diagnostic scoring systems such as the Wells’ criteria, Pulmonary Embolism Rule-out Criteria (PERC), or the Geneva scoring system should be applied. Once a reasonable a priori probability of embolus has been established, the presence of lung parenchymal opacities should be assessed on a current chest radiograph or CT. When lung opacification is present, the patient should be referred for alternate testing, generally with CT pulmonary angiography (CTPA). If the lungs are clear, we propose that the patient should proceed to perfusion scintigraphy, using either planar or tomographic imaging. If the perfusion scan does not demonstrate segmental defects, the scan is deemed negative for embolism. When segmental defects are present, the scan should be interpreted as indeterminate and the patient referred for alternate testing if greater certainty is required.

As a general rule, alternate testing should consist of CTPA. When leg symptoms are present or in the case of CTPA contraindications such as contrast allergy, performance of deep vein Doppler studies to assess for deep vein thrombosis can be considered. Alternatively, when mandated by the clinical situation, a full ventilation/perfusion study with appropriate aerosol precautions may be completed. It is possible to perform ventilation studies on the same day as the perfusion study with a larger dosage of inhaled radiopharmaceutical if the perfusion study was performed using low levels of radiopharmaceutical. Conversely, the study can be repeated on a subsequent day.

In summary, tectonic upheavals in our clinical world necessitate a change in our approach to previously settled diagnostic algorithms; we suggest reverting to a nonventilation approach for the evaluation of pulmonary embolus to minimize potential exposure of aerosolized secretions to others in the nuclear medicine suite.

DISCLOSURE

Leonard Freeman is a member on the advisory panel of Jubilant Pharma. No other potential conflict of interest relevant to this article was reported.

Footnotes

  • Published online Apr. 1, 2020.

  • © 2020 by the Society of Nuclear Medicine and Molecular Imaging.

Immediate Open Access: Creative Commons Attribution 4.0 International License (CC BY) allows users to share and adapt with attribution, excluding materials credited to previous publications. License: https://creativecommons.org/licenses/by/4.0/.Details:http://jnm.snmjournals.org/site/misc/permission.xhtml.

REFERENCES

  1. 1.↵
    1. Williams DA,
    2. Carlson C,
    3. McEnerney K,
    4. Hope E,
    5. Hoh CK
    . Technetium-99m DTPA aerosol contamination in lung ventilation studies. J Nucl Med Technol. 1998;26:43–44.
    OpenUrlAbstract/FREE Full Text
  2. 2.↵
    1. Achey B,
    2. Miller K,
    3. Erdman M,
    4. King S
    . Potential dose to nuclear medicine technologists from 99mTc-DTPA aerosol lung studies. Health Phys. 2004;86:S85–S87.
    OpenUrlPubMed
  3. 3.↵
    1. Miniati M,
    2. Pistolesi M,
    3. Marini C,
    4. et al
    . Value of perfusion lung scan in the diagnosis of pulmonary embolism: results of the Prospective Investigative Study of Acute Pulmonary Embolism Diagnosis (PISA-PED). Am J Respir Crit Care Med. 1996;154:1387–1393.
    OpenUrlCrossRefPubMed
  4. 4.
    1. Sostman HD,
    2. Miniati M,
    3. Gottschalk A,
    4. Matta F,
    5. Stein PD,
    6. Pistolesi M
    . Sensitivity and specificity of perfusion scintigraphy combined with chest radiography for acute pulmonary embolism in PIOPED II. J Nucl Med. 2008;49:1741–1748.
    OpenUrlAbstract/FREE Full Text
  5. 5.↵
    1. Bajc M,
    2. Miniati M,
    3. Jogi J,
    4. Stein PD
    . Perfusion SPECT in patients with suspected pulmonary embolism. Eur J Nucl Med Mol Imaging. 2013;40:1432–1437.
    OpenUrl
  • Received for publication March 19, 2020.
  • Accepted for publication March 21, 2020.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 61 (5)
Journal of Nuclear Medicine
Vol. 61, Issue 5
May 1, 2020
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Diagnostic Evaluation of Pulmonary Embolism During the COVID-19 Pandemic
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Diagnostic Evaluation of Pulmonary Embolism During the COVID-19 Pandemic
Lionel S. Zuckier, Renée M. Moadel, Linda B. Haramati, Leonard M. Freeman
Journal of Nuclear Medicine May 2020, 61 (5) 630-631; DOI: 10.2967/jnumed.120.245571

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Diagnostic Evaluation of Pulmonary Embolism During the COVID-19 Pandemic
Lionel S. Zuckier, Renée M. Moadel, Linda B. Haramati, Leonard M. Freeman
Journal of Nuclear Medicine May 2020, 61 (5) 630-631; DOI: 10.2967/jnumed.120.245571
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Lung Scintigraphy for Pulmonary Embolism Diagnosis in COVID-19 Patients: A Multicenter Study
  • Experience with a Perfusion-Only Screening Protocol for Evaluation of Pulmonary Embolism During the COVID-19 Pandemic Surge
  • V/Q SPECT/CT in the Time of COVID-19: Changing the Order to Improve Safety Without Sacrificing Accuracy
  • SNMMI Statement: COVID-19 and Ventilation/Perfusion (V/Q) Lung Studies
  • Beneficial Effects of Intermediate Dosage of Anticoagulation Treatment on the Prognosis of Hospitalized COVID-19 Patients: The ETHRA Study
  • Nuclear Medicine Clinical Practice in the United States During the COVID-19 Era and Beyond
  • Reply: COVID-19 and Pulmonary Embolism: Diagnostic Imaging Trends
  • COVID-19 and Pulmonary Embolism: Diagnostic Imaging Trends
  • Two Leaders
  • Dr. Li Wenliang and the Time of COVID-19
  • D-dimer as an indicator of prognosis in SARS-CoV-2 infection: a systematic review
  • Pulmonary embolism: yet another cause of hypoxaemic respiratory failure in COVID-19
  • Google Scholar

More in this TOC Section

  • Incidental Findings Suggestive of COVID-19 in Asymptomatic Patients Undergoing Nuclear Medicine Procedures in a High-Prevalence Region
  • Nuclear Medicine Operations in the Times of COVID-19: Strategies, Precautions, and Experiences
Show more Covid-19 Commentaries

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire