Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
LetterLetters to the Editor

The Potential for Low-Dose Functional Studies in Maternal–Fetal Medicine Using PET/MR Imaging

Terry Jones and Thomas F. Budinger
Journal of Nuclear Medicine November 2013, 54 (11) 2016-2017; DOI: https://doi.org/10.2967/jnumed.113.123919
Terry Jones
*The PET Research Advisory Company 8 Prestbury Rd. Wilmslow, Cheshire, SK9 2LJ, U.K. E-mail:
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: terry.jones40@googlemail.com
Thomas F. Budinger
*The PET Research Advisory Company 8 Prestbury Rd. Wilmslow, Cheshire, SK9 2LJ, U.K. E-mail:
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • For correspondence: terry.jones40@googlemail.com
  • Article
  • Info & Metrics
  • PDF
Loading

TO THE EDITOR: We wish to draw attention to the potential for a novel application of PET/MR imaging for studies of the human fetus in vivo. This application fills the unmet need for modern preventive medicine at the beginning of life. We believe that administering low levels of imaging biomarkers labeled with short-lived positron emitters such as 15O and 11C to the pregnant mother, in conjunction with high-sensitivity PET, will allow sufficient data acquisition to examine tracer kinetics in the fetus at acceptable absorbed doses of radiation. This application might open a new investigative area for molecular imaging that has the potential to substantially affect clinical care and lifelong health. Conceptual studies might include measuring oxygen uptake in the fetal brain using the 2.1-min half-life tracer 15O. Nutrient delivery or metabolism investigations might be undertaken using, for example, 11C-labeled amino acids, as shown in pioneering research performed on nonhuman primates (1). Studies to detect inflammation in the fetus might be enabled using biomarkers of the 18-kDa translocator protein. Important placenta transport functions might be investigated using markers such as a substrate for system A transporters: for example, [N-methyl-11C]α-methylaminoisobutyric acid (2).

The importance and need to study aspects of fetus function in vivo are based on some compelling facts:

  • Three million stillborn deaths occur every year worldwide (3).

  • Fifteen million premature births occur every year worldwide. Of these, 1.1 million babies die of preterm complications, and many surviving babies are disabled. The United States ranks third in the world, with 12% preterm births (4).

  • Intrauterine growth restriction is the cause of many neonatal deaths and premature births. It is believed to be caused by an abnormal placenta and altered transporter expression and function (2). It is associated with raised neonatal mortality and morbidity and with an increased incidence of diabetes, hypertension, ischemic heart disease, and metabolic syndrome in adulthood (2).

  • Fetal inflammation is associated with increased schizophrenia, autism, cognitive impairment, and neurologic diseases in later life (5,6).

Applying the sensitivity and specificity of PET to the challenges of fetal medicine might have a prospective lifelong impact on health, compared with the current emphasis on retrospective late-in-life imaging studies of established diseases such as cancer and dementia. PET has unique sensitivity for detecting low levels of radioactivity, enhanced through time-of-flight (TOF) acquisition of 3-dimensional data and extended axial field-of-view tomographs (7). Because the levels of administered radioactivity are likely to be below that needed to reconstruct images with contemporary spatial resolution, a key advantage of combined PET/MR imaging is that volumes of interest for the maternal aortic arterial blood pool, the placenta, and the whole body or brain of the fetus could be derived from MR imaging and placed into PET sinogram space. This would permit reconstructions for predetermined volumes with minimal statistical noise (8), thus enabling accurate kinetic and tissue concentration data. In addition, MR imaging–based attenuation correction obviates the CT dose, and MR imaging enables motion compensation for dynamic datasets. PET imaging of the large pregnant abdomen would capitalize on the value of TOF in reducing noise within the reconstructed data. Because the fetus is surrounded by the amniotic fluid cavity, which would exchange tracer slowly with the maternal blood, it is enclosed in a space devoid of tracer. Hence, spillover of signal from surrounding maternal tissue would be minimal, and MR imaging–guided volume-of-interest reconstructions within the cavity would provide accurate measures of the scatter background. The resulting reconstructed datasets would then provide the tissue concentration time-course data from which functional measurements of delivery and exchange to the placenta and fetus could be derived. There is also the opportunity to avoid reconstructions by deriving, with more statistical certainty, the tissue concentrations and time–activity data for the fetus and placenta directly from counts that fall within the TOF-defined volume. These would amount to a diameter of some 15 cm, which is equivalent to 2 × 7.5 cm in full width at half maximum, as is achievable with currently practiced 500-ps timing.

Mother–fetus body kinetic studies using an 11C-labeled compound should be possible with activity as low as 18.5 MBq. This is estimated to result in an absorbed radiation dose to the fetus of 0.2–0.5 mSv based on our calculations using the MIRD schema (9) that depend on fetal age and accumulated activity, and estimates made by others for 18F-FDG (10). This dose is a fifteenth of the annual dose, including radon, of 3 mSv in the United States. Such estimates are in line with reports about fetuses accidentally irradiated in pregnant patients undergoing 18F-FDG imaging for cancer (10). Notably, the fetus is less sensitive to radiation when near term (when one would propose imaging evaluations) than earlier in gestation. Furthermore, operating PET at low counting rates with minimal registration of dead time and random coincidences, together with accurate measures of the scatter contribution, would result in maximum noise-equivalent counts per unit of administered radioactivity and hence optimum signal per unit of absorbed dose. If the methodology of TOF windowing were to be developed to record tracer concentrations in the fetus directly and thereby avoid reconstruction, it is expected that the needed radioactivity would be an order of magnitude lower.

The potential ability of PET to trace the passage of a chemical compound from mother to fetus epitomizes the fundamental strength of the tracer principle. When PET is combined with the range of molecules that can be labeled with 11C, a broad and important area for investigation could be uniquely empowered to uncover new information on the relationship of intrauterine health to the lifelong health of an individual. If this field were to develop, it could also stimulate the advance of generic PET methodology by increasing the PET axial field of view (7) and introducing faster detectors for TOF imaging; together, sensitivity is foreseen to be more than one order of magnitude greater than that of current practice. We propose that the molecular imaging community consider fostering this application of PET/MR imaging, initially by engagement with fetal health experts and obstetricians. Undertaking preclinical studies on large pregnant animals, such as sheep, would then be appropriate to consolidate the combined methodologies and establish firm radiation dose facts to enable future studies on humans.

Footnotes

  • Published online Sep. 12, 2013.

  • © 2013 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

REFERENCES

  1. 1.↵
    1. Berglund L,
    2. Halldin C,
    3. Lilja A,
    4. et al
    . 11C-methionine kinetics in pregnant rhesus monkeys studied by positron emission tomography: a new approach to feto-maternal metabolism. Acta Obstet Gynecol Scand. 1984;63:641–645.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Sibley CP,
    2. Turner MA,
    3. Cetin I,
    4. et al
    . Placental phenotypes of intrauterine growth. Pediatr Res. 2005;58:827–832.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Cousens S,
    2. Blencowe H,
    3. Stanton C,
    4. et al
    . National, regional, and worldwide estimates of stillbirth rates in 2009 with trends since 1995: a systematic analysis. Lancet. 2011;377:1319–1330.
    OpenUrlCrossRefPubMed
  4. 4.↵
    1. Chang HH,
    2. Larson J,
    3. Blencowe H,
    4. et al
    . Preventing preterm births: analysis of trends and potential reductions with interventions in 39 countries with very high human development index. Lancet. 2013;381:223–234.
    OpenUrlCrossRefPubMed
  5. 5.↵
    1. Hagberg H,
    2. Gressens P,
    3. Mallard C
    . Inflammation during fetal and neonatal life: implications for neurologic and neuropsychiatric disease in children and adults. Ann Neurol. 2012;71:444–457.
    OpenUrlCrossRefPubMed
  6. 6.↵
    1. Kinney DK,
    2. Hintz K,
    3. Shearer EM,
    4. et al
    . A unifying hypothesis of schizophrenia: abnormal immune system development may help explain roles of prenatal hazards, post-pubertal onset, stress, genes, climate, infections, and brain dysfunction. Med Hypotheses. 2010;74:555–563.
    OpenUrlCrossRefPubMed
  7. 7.↵
    1. Poon JK,
    2. Dahlbom ML,
    3. Moses WW,
    4. et al
    . Optimal whole-body PET scanner configurations for different volumes of LSO scintillator: a simulation study. Phys Med Biol. 2012;57:4077–4094.
    OpenUrlCrossRefPubMed
  8. 8.↵
    1. Huesman RH
    . A new fast algorithm for the evaluation of regions of interest and statistical uncertainty in computed tomography. Phys Med Biol. 1984;29:543–552.
    OpenUrlCrossRefPubMed
  9. 9.↵
    1. Loevinger R,
    2. Budinger TF,
    3. Watson EE
    . MIRD Primer of Absorbed Dose Calculations. Revised edition. Reston, VA: Society of Nuclear Medicine and Molecular Imaging; 1991.
  10. 10.↵
    1. Takalkar AM,
    2. Khandelwal A,
    3. Lokitz S,
    4. Lilien DL,
    5. Stabin MG
    . 18F-FDG PET in pregnancy and fetal radiation dose estimates. J Nucl Med. 2011;52:1035–1040.
    OpenUrlAbstract/FREE Full Text
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 54 (11)
Journal of Nuclear Medicine
Vol. 54, Issue 11
November 1, 2013
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
The Potential for Low-Dose Functional Studies in Maternal–Fetal Medicine Using PET/MR Imaging
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
The Potential for Low-Dose Functional Studies in Maternal–Fetal Medicine Using PET/MR Imaging
Terry Jones, Thomas F. Budinger
Journal of Nuclear Medicine Nov 2013, 54 (11) 2016-2017; DOI: 10.2967/jnumed.113.123919

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
The Potential for Low-Dose Functional Studies in Maternal–Fetal Medicine Using PET/MR Imaging
Terry Jones, Thomas F. Budinger
Journal of Nuclear Medicine Nov 2013, 54 (11) 2016-2017; DOI: 10.2967/jnumed.113.123919
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Footnotes
    • REFERENCES
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Development and Evaluation of mini-EXPLORER: A Long Axial Field-of-View PET Scanner for Nonhuman Primate Imaging
  • Total-Body PET: Maximizing Sensitivity to Create New Opportunities for Clinical Research and Patient Care
  • Total-body imaging: Transforming the role of positron emission tomography
  • Potential Pediatric Applications of PET/MR
  • Google Scholar

More in this TOC Section

  • Business Model Beats Science and Logic: Dosimetry and Paucity of Its Use
  • Determining PSMA-617 Mass and Molar Activity in Pluvicto Doses
  • The Value of Functional PET in Quantifying Neurotransmitter Dynamics
Show more Letters to the Editor

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire