[PDF][PDF] Renal technetium-99m-DMSA SPECT in normal volunteers

C De Sadeleer, A Bossuyt, E Goes… - Journal of Nuclear …, 1996 - Soc Nuclear Med
Dimercaptosuccinic acid (DMSA) renal scintigraphy today is consid ered a sensitive and
useful technique for the detection of cortical abnormalities. Recent studies have suggested …

Renal function studies using 99mTc-dimercaptosuccinic acid

J KAWAMURA, S HOSOKAWA… - Clinical Nuclear …, 1979 - journals.lww.com
Abstract 99m Tc-dimercaptosuccinic acid (DMSA), provides both a well defined renal image
via preferential cortical accumulation, and a quantitative assessment of separate kidney …

[PDF][PDF] Quantitation of renal uptake of technetium-99m DMSA using SPECT

D Groshar, A Frankel, G Iosilevsky… - Journal of nuclear …, 1989 - Soc Nuclear Med
Quantitativesinglephotonemissioncompute… (SPECT) methodologybasedon calibration
with kidney phantoms has been applied for the assessment of renal uptake of [@ †œTc] …

Qualitative and quantitative evaluation of renal parenchymal damage by99mTc-DMSA planar and SPECT scintigraphy

K Itoh, T Yamashita, E Tsukamoto, K Nonomura… - Annals of nuclear …, 1995 - Springer
The initial 99m Tc-DMSA studies carried out over a four year period in 229 patients with
various heterogenic causes of lower urinary tract abnormalities were reviewed. Anatomical …

[HTML][HTML] Technetium-99m dimercaptosuccinic acid scan in evaluation of renal cortical scarring: Is it mandatory to do single photon emission computerized tomography …

HRS Farghaly, MHM Sayed - Indian Journal of Nuclear Medicine, 2015 - journals.lww.com
Objectives: Renal cortical scintigraphy with technetium-99m (Tc-99m) dimercaptosuccinic
acid (DMSA) is the method of choice to detect acute pyelonephritis and cortical scarring …

Methods for measuring the renal uptake rate of99mTc-dimercaptosuccinic acid (DMSA) : a comparative study

K Murase, S Tanada, I Masahiro, M Yokoyarna… - European journal of …, 1990 - Springer
A comparative study of the renal uptake rate of 99m Tc-dimercaptosuccinic acid (DMSA) was
performed using a phantom study and clinical data from 100 patients (200 kidneys) with a …

Kidney Scintigraphy with 99mTC-DMSA and 131I-Hippurate

I Holten, HH Storm - Scandinavian Journal of Urology and …, 1979 - Taylor & Francis
43 patients underwent an extended scintigraphic procedure with 99mTc-
dimercaptosuccinylic acid in order to investigate its proper use for diagnosing morphological …

[CITATION][C] An interesting artifact in radionuclide imaging of the kidneys

KA McKusick, LS Malmud, PT Kirchner… - Journal of Nuclear …, 1973 - Soc Nuclear Med
lull/CASE REPORT Page 1 An artifactural area of increased activity in a kidney scan obtained
with 99―TC-DTPAis at tributed to gastric secretion of free technetium. The presence of such …

An evaluation of 99Tcm-DMSA SPET with three-dimensional reconstruction in 68 patients with varied renal pathology

GJR Cook, MK Lewis, SEM Clarke - Nuclear medicine …, 1995 - journals.lww.com
Sixty-eight patients (135 kidneys) with varied renal pathology were evaluated with 99Tcm-
dimercapto-succinic acid (DMSA) single photon emission tomography (SPET) to determine …

Role of technetium-99m N, N-ethylenedicysteine renal scintigraphy in the evaluation of differential renal function and cortical defects

G Buyukdereli, IB Guney - Clinical nuclear medicine, 2006 - journals.lww.com
Purpose: This study was performed to evaluate the effectiveness of technetium-99m N, N-
ethylenedicysteine (Tc-99m EC) in comparison to technetium-99m dimercaptosuccinic acid …