Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleClinical Investigations

Prognostic Value of 68Ga-DOTANOC PET/CT SUVmax in Patients with Neuroendocrine Tumors of the Pancreas

Valentina Ambrosini, Davide Campana, Giulia Polverari, Chiara Peterle, Stefania Diodato, Claudio Ricci, Vincenzo Allegri, Riccardo Casadei, Paola Tomassetti and Stefano Fanti
Journal of Nuclear Medicine December 2015, 56 (12) 1843-1848; DOI: https://doi.org/10.2967/jnumed.115.162719
Valentina Ambrosini
1Nuclear Medicine, Department of Experimental Diagnostic and Specialized Medicine, University of Bologna and S. Orsola–Malpighi Hospital, Bologna, Italy; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Davide Campana
2Department of Medical and Surgical Sciences, S. Orsola–Malpighi University Hospital, Bologna, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Giulia Polverari
1Nuclear Medicine, Department of Experimental Diagnostic and Specialized Medicine, University of Bologna and S. Orsola–Malpighi Hospital, Bologna, Italy; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Chiara Peterle
1Nuclear Medicine, Department of Experimental Diagnostic and Specialized Medicine, University of Bologna and S. Orsola–Malpighi Hospital, Bologna, Italy; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Stefania Diodato
1Nuclear Medicine, Department of Experimental Diagnostic and Specialized Medicine, University of Bologna and S. Orsola–Malpighi Hospital, Bologna, Italy; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Claudio Ricci
2Department of Medical and Surgical Sciences, S. Orsola–Malpighi University Hospital, Bologna, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Vincenzo Allegri
1Nuclear Medicine, Department of Experimental Diagnostic and Specialized Medicine, University of Bologna and S. Orsola–Malpighi Hospital, Bologna, Italy; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Riccardo Casadei
2Department of Medical and Surgical Sciences, S. Orsola–Malpighi University Hospital, Bologna, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Paola Tomassetti
2Department of Medical and Surgical Sciences, S. Orsola–Malpighi University Hospital, Bologna, Italy
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Stefano Fanti
1Nuclear Medicine, Department of Experimental Diagnostic and Specialized Medicine, University of Bologna and S. Orsola–Malpighi Hospital, Bologna, Italy; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

This study was performed to investigate the role of 68Ga-DOTANOC SUVmax as a potential prognostic factor in patients with pancreatic neuroendocrine tumor (pNET). Methods: Among the patients who underwent 68Ga-DOTANOC PET/CT, we retrospectively collected the data of those who had G1 or G2 pNET (2010 World Health Organization classification), presented with disease on PET/CT and CT, and had at least 6 mo of follow-up. Patients with multiple endocrine neoplasia were excluded. Results: Overall, 43 patients were included. No significant differences in SUVmax were observed with respect to sex, tumor syndrome, stage, World Health Organization classification, or Ki-67. During follow-up (median, 20 mo), 11 patients (35.6%; median, 33 mo; interquartile range, 20–48 mo) had stable disease and 32 (74.4%; median, 19 mo; interquartile range, 14–26 mo) had progressive disease. SUVmax at 24 mo of follow-up was significantly higher (P = 0.022) in patients with stable disease than in patients with progressive disease. The best SUVmax cutoff ranged from 37.8 to 38.0. The major risk factors for progression included an SUVmax of no more than 37.8 (hazard ratio, 3.09; P = 0.003), a Ki-67 of more than 5% (hazard ratio, 2.89; P = 0.009), and medical therapy alone (hazard ratio, 2.36; P = 0.018). Advanced stage (IV) (P = 0.026), an SUVmax of less than 37.8 (P = 0.043), and medical therapy alone (P = 0.015) were also confirmed at multivariate analysis. Median progression-free survival was 23 mo. Significant differences in progression-free survival were observed in relationship to Ki-67 (median, 45 mo for Ki-67 ≤ 5% and 20 mo for Ki-67 > 5%; P = 0.005), SUVmax (<37.8 vs. >38.0: 16.0 vs. 27.0 mo; P = 0.002), and type of therapy (medical vs. peptide receptor radionuclide therapy: 16.0 vs. 26.0 mo; P = 0.014). Conclusion: 68Ga-DOTANOC SUVmax is a relevant prognostic factor in patients with G1 and G2 pNET, and its routine use will improve disease characterization and management in these patients, who may present with atypical cases showing heterogeneous clinical behavior.

  • 68Ga-DOTA-NOC
  • PET/CT
  • SUVmax
  • NET
  • pancreas

Footnotes

  • Published online Sep. 24, 2015.

  • © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
View Full Text
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 56 (12)
Journal of Nuclear Medicine
Vol. 56, Issue 12
December 1, 2015
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Prognostic Value of 68Ga-DOTANOC PET/CT SUVmax in Patients with Neuroendocrine Tumors of the Pancreas
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Prognostic Value of 68Ga-DOTANOC PET/CT SUVmax in Patients with Neuroendocrine Tumors of the Pancreas
Valentina Ambrosini, Davide Campana, Giulia Polverari, Chiara Peterle, Stefania Diodato, Claudio Ricci, Vincenzo Allegri, Riccardo Casadei, Paola Tomassetti, Stefano Fanti
Journal of Nuclear Medicine Dec 2015, 56 (12) 1843-1848; DOI: 10.2967/jnumed.115.162719

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Prognostic Value of 68Ga-DOTANOC PET/CT SUVmax in Patients with Neuroendocrine Tumors of the Pancreas
Valentina Ambrosini, Davide Campana, Giulia Polverari, Chiara Peterle, Stefania Diodato, Claudio Ricci, Vincenzo Allegri, Riccardo Casadei, Paola Tomassetti, Stefano Fanti
Journal of Nuclear Medicine Dec 2015, 56 (12) 1843-1848; DOI: 10.2967/jnumed.115.162719
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Semiautomatic Tumor Delineation for Evaluation of 64Cu-DOTATATE PET/CT in Patients with Neuroendocrine Neoplasms: Prognostication Based on Lowest Lesion Uptake and Total Tumor Volume
  • Somatostatin Receptor Imaging and Theranostics: Current Practice and Future Prospects
  • 64Cu-DOTATATE PET/CT and Prediction of Overall and Progression-Free Survival in Patients with Neuroendocrine Neoplasms
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles

Keywords

  • 68Ga-DOTA-NOC
  • PET/CT
  • SUVmax
  • NET
  • pancreas
SNMMI

© 2025 SNMMI

Powered by HighWire