Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleClinical Investigations

V/Q SPECT Interpretation for Pulmonary Embolism Diagnosis: Which Criteria to Use?

Pierre-Yves Le Roux, Philippe Robin, Aurélien Delluc, Ronan Abgral, Alexandra Le Duc-Pennec, Emmanuel Nowak, Francis Couturaud, Grégoire Le Gal and Pierre-Yves Salaun
Journal of Nuclear Medicine July 2013, 54 (7) 1077-1081; DOI: https://doi.org/10.2967/jnumed.112.113639
Pierre-Yves Le Roux
1Université Européenne de Bretagne, Brest, France
2Université de Brest, EA3878 (GETBO) IFR 148, Brest, France
3CHRU de la Cavale Blanche, Service de Médecine Nucléaire, Brest, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Philippe Robin
1Université Européenne de Bretagne, Brest, France
2Université de Brest, EA3878 (GETBO) IFR 148, Brest, France
3CHRU de la Cavale Blanche, Service de Médecine Nucléaire, Brest, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Aurélien Delluc
1Université Européenne de Bretagne, Brest, France
2Université de Brest, EA3878 (GETBO) IFR 148, Brest, France
4CHRU de la Cavale Blanche, Département de Médecine Interne et de Pneumologie, Brest, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ronan Abgral
1Université Européenne de Bretagne, Brest, France
2Université de Brest, EA3878 (GETBO) IFR 148, Brest, France
3CHRU de la Cavale Blanche, Service de Médecine Nucléaire, Brest, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Alexandra Le Duc-Pennec
1Université Européenne de Bretagne, Brest, France
2Université de Brest, EA3878 (GETBO) IFR 148, Brest, France
3CHRU de la Cavale Blanche, Service de Médecine Nucléaire, Brest, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Emmanuel Nowak
5INSERM CIC 05-02 IFR148, Brest, France; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Francis Couturaud
1Université Européenne de Bretagne, Brest, France
2Université de Brest, EA3878 (GETBO) IFR 148, Brest, France
4CHRU de la Cavale Blanche, Département de Médecine Interne et de Pneumologie, Brest, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Grégoire Le Gal
1Université Européenne de Bretagne, Brest, France
4CHRU de la Cavale Blanche, Département de Médecine Interne et de Pneumologie, Brest, France
6Université de Brest, INSERM CIC 05-02 IFR148, Brest, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pierre-Yves Salaun
1Université Européenne de Bretagne, Brest, France
2Université de Brest, EA3878 (GETBO) IFR 148, Brest, France
3CHRU de la Cavale Blanche, Service de Médecine Nucléaire, Brest, France
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Ventilation–perfusion (V/Q) SPECT has been reported to improve the diagnostic performance of V/Q imaging for the diagnosis of pulmonary embolism (PE). However, only sparse data based on an objective reference test are available, and the criteria used for interpretation have varied widely. Therefore, the aim of our study was to assess the performance of V/Q SPECT using various criteria for interpretation, in comparison with a validated independent diagnostic strategy. Methods: The SPECT study included patients for whom V/Q SPECT data were compared with the results of an independent and validated diagnostic algorithm for PE. V/Q SPECT scans were performed after intravenous injection of 99mTc-macroaggregated albumin and simultaneous ventilation with 81mKr gas. Interpretation was performed independently by 2 nuclear medicine physicians who were not aware of the clinical history, diagnostic strategy conclusion, or patient’s outcome. Sensitivity, specificity, and likelihood ratios were evaluated for various combinations of mismatched defect numbers and sizes (segmental or subsegmental). Generation of receiver-operating-characteristic curves was based on the number of mismatch defects and the number of subsegmental mismatch defects or equivalent. Results: Of the 249 patients who were analyzed, the diagnosis of PE was confirmed in 49 and ruled out in 200 according to the previously validated independent strategy. Of all the tested criteria, the best performance was achieved using a diagnostic cutoff of at least 1 segmental or 2 subsegmental mismatches, with sensitivity and specificity of 0.92 (95% confidence interval, 0.84–1) and 0.91 (95% confidence interval, 0.87–0.95), respectively. With a negative V/Q SPECT result, the posttest probability of PE was 0.010, 0.037, and 0.119 for a low, intermediate, and high clinical probability. With a positive V/Q SPECT result, the posttest probability of PE was 0.531, 0.814, and 0.939 for a low, intermediate, and high probability. Conclusion: For V/Q SPECT interpretation, a diagnostic cutoff of 1 segmental or 2 subsegmental mismatches seems best for confirming or excluding acute PE.

  • V/Q SPECT
  • pulmonary embolism
  • criteria

Planar ventilation–perfusion (V/Q) lung scintigraphy was the first validated noninvasive procedure for the diagnosis of pulmonary embolism (PE). In the late 1980s, chest CT overtook V/Q scanning in most institutions as the initial imaging modality for suspected PE, mainly because of the high rate of inconclusive results from planar V/Q scintigraphy using the probabilistic interpretation proposed in the PIOPED study (prospective investigation of pulmonary embolism diagnosis) (1).

More recently, there has been a renewed interest in V/Q imaging, primarily in response to concerns about high radiation exposure from CT angiography (2). Indeed, the radiation dose is lower with V/Q scintigraphy than with chest multidetector CT (MDCT), particularly to the female breast (3–5). Another drawback of MDCT is that it cannot be performed in many patients because of contraindications such as renal failure or an allergy to the contrast agent. Insufficient quality is also responsible for inconclusive results in 5%–10% of cases. Moreover, V/Q imaging might be the best-adapted modality for follow-up, especially for the diagnosis of recurrence (6) or for therapeutic assessment. In view of these considerations, V/Q imaging remains a powerful tool for the diagnosis of PE. In addition, the use of SPECT has been reported to improve the performance of V/Q imaging thanks to better spatial resolution and limited overlapping of perfusion defects by other structures. Studies have suggested that the performance of V/Q SPECT could at least equal that of MDCT (7).

In a recent study, we showed satisfactory accuracy for V/Q SPECT in the diagnosis of PE integrated into a validated diagnostic strategy, despite the use of the revised PIOPED criteria for interpretation, which were initially developed only for V/Q planar scans and are probably inadequate for V/Q SPECT (8). Before V/Q SPECT is integrated into routine practice, it is of the utmost importance that the interpretation criteria for V/Q SPECT be validated. Indeed, the medical literature shows an important variability in the criteria used for the diagnosis of PE. For example, some studies suggested that 1 mismatch defect, regardless of size, was sufficient for the diagnosis of PE (9–11), whereas in others, 1 segmental mismatch (12) or 2 mismatches (7) were necessary. In 2009, the European Association of Nuclear Medicine published guidelines for V/Q scintigraphy in which criteria for reading V/Q SPECT images were proposed. However, these criteria were not validated according to a clear, independent gold standard (13).

The aim of our study was to assess the accuracy of various criteria for V/Q SPECT interpretation, using as a reference standard a validated independent diagnostic strategy.

MATERIALS AND METHODS

The eligible study population consisted of patients with suspected PE who had been consecutively included in a prospective diagnostic accuracy study that assessed the performance of V/Q SPECT (8,14). The methods of the study have been extensively described elsewhere (8,14). Briefly, the study consisted of patients aged 18 y or older who were seen as inpatients or outpatients at Brest University Hospital because of symptoms suggestive of PE. The clinical probability of PE was assessed by the physicians in charge according to the clinical model described by Wells et al. and was rated as low, intermediate, or high (15). To be considered for inclusion, patients had to have either a high clinical probability of PE or an abnormal concentration of plasma enzyme-linked immunosorbent assay d-dimer (>500 μg/mL). Exclusion criteria were pregnancy, breastfeeding, life expectancy of less than 3 mo, impossibility of follow-up, anticoagulant treatment long-term or beginning more than 48 h before the time of screening, and confirmed or massive PE. The protocol was approved by the Ethics Committee of our institution and was registered with institutional review board authorization number 04.036 on the clinical trials.gov Web site (NCT01183026). Written informed consent was obtained from all patients.

All included patients underwent a standardized diagnostic strategy. First, the patients underwent lower-limb vein compression sonography. PE was considered present in patients with proximal deep venous thrombosis (16). Patients with no deep venous thrombosis on sonography underwent a V/Q planar lung scan. Dual-isotope (99mTc-macroaggregated albumin/81mKr gas) V/Q planar lung scans were acquired with 6 standard views (anterior, posterior, right and left lateral, and right and left posterior oblique), and the nuclear medicine physician on duty classified them on the basis of the revised PIOPED criteria (normal, low, intermediate, or high) (17). The results of chest radiography did not affect the choice of imaging procedure in the diagnostic algorithm but were available for interpretation. PE was diagnosed in patients with an intermediate or high clinical probability of PE and a high-probability V/Q scan. PE was ruled out in patients with normal V/Q findings, a low or intermediate clinical probability of PE and a low-probability V/Q scan, or a low clinical probability of PE and an intermediate-probability V/Q scan. All other patients underwent chest MDCT, which was interpreted by a vascular radiologist. Detailed results have previously been reported (8,14).

The safety of the diagnostic strategy was assessed by monitoring the risk of thromboembolic events during the 3-mo follow-up period in patients deemed not to have PE according to the initial diagnostic work-up.

V/Q SPECT Acquisition and Interpretation

All patients who required a planar V/Q scan also underwent pulmonary V/Q SPECT at the same time. Pulmonary SPECT consisted of perfusion SPECT and ventilation SPECT performed simultaneously (i.e., 128 projections of 12 s each, 360°) immediately after the planar images were acquired, with the patient remaining supine. Planar and SPECT scans were obtained after a single intravenous injection of 200 MBq of 99mTc-macroaggregated albumin and simultaneous ventilation with 81mKr gas obtained using an 81Rb/81mKr generator. Images were acquired using a dual-head camera (DST Xli; SMV) equipped with low-energy, high-resolution collimators in a 128 × 128 matrix. Images were collected with 2 energy windows centered on a photopeak of 140 keV ± 10% (99mTc) for perfusion and 190 keV ± 10% (81mKr) for ventilation. V/Q SPECT images were numerically stored but not interpreted until the completion of the patient’s follow-up.

Retrospectively, V/Q SPECT results were interpreted independently by 2 nuclear medicine physicians who did not know the clinical history, reference strategy imaging results, diagnostic conclusion, or patient’s outcome. Any difference of interpretation was resolved by consensus.

The location, type (matched or mismatched), and extent (segmental or subsegmental) of each defect were recorded. A mismatched defect was defined as a pulmonary region affected by a severe reduction or complete loss of perfusion along with distinctly reduced ventilation. The extent of each defect was assessed visually. A defect was defined as segmental if it involved more than 75% of a segment and subsegmental if it involved less than 75%. The tested criteria were as follows: 1 mismatch, regardless of size; at least 1 segmental mismatch; at least 2 mismatches, regardless of size; at least 1 segmental or 2 subsegmental mismatches; more than 1 segmental mismatch; at least 2 segmental mismatches; and at least 3 mismatches, regardless of size.

Data Analysis

Standard statistical measures of diagnostic accuracy were used for each tested criterion, including sensitivity, specificity, and likelihood ratios. Generation of receiver-operating-characteristic curves was based on the number of mismatch defects and the number of subsegmental mismatch defects or equivalent. Areas under the curve were calculated from the receiver-operating-characteristic curves.

RESULTS

We included 321 patients over the 28-mo inclusion period, with a median age of 72 y (range, 18–95 y).

Diagnostic Strategy Including Conventional V/Q Scans

Sonography showed a proximal deep venous thrombosis, establishing venous thromboembolism, in 43 patients (13%). A V/Q scan was therefore required in 278 patients (87%). Among the remaining 278 patients, the diagnosis of PE was confirmed in 55 (20%) and ruled out in 220 (79%). Three patients (1%) did not undergo chest MDCT as per study protocol and hence could not be classified regarding the diagnosis of PE. All 3 received anticoagulant therapy on the basis of a distal-only deep venous thrombosis and were excluded from further analysis. Follow-up was completed successfully for all patients. The 3-mo thromboembolic risk in patients not given anticoagulants, based on the results of the diagnostic protocol, was 0.53% (95% confidence interval [CI], 0.09–2.94).

V/Q SPECT Interpretation

Among 278 patients who underwent conventional planar V/Q scans, V/Q SPECT data could not be analyzed in 26 patients (9%) mainly because of handling and operative constraints (n = 5), technical pitfalls (n = 3), or loss of numerically stored data (n = 18). Therefore, 249 patients with V/Q SPECT and clinical outcome were analyzed. Figure 1 summarizes the results of the diagnostic strategy for these 249 patients.

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Study flow chart. Interm. = intermediate; OAT = oral anticoagulant therapy; VTE = venous thromboembolism.

Sensitivity and specificity were calculated for each of the criteria tested (Table 1). The highest sensitivity (0.92; 95% CI, 0.84–1) was achieved using a diagnostic cutoff either of 1 segmental or subsegmental mismatch or of 1 segmental or 2 subsegmental mismatches. Regarding these 2 criteria, specificity was 0.91 (95% CI, 0.87–0.95) for 1 segmental or subsegmental mismatch versus 0.84 (95% CI, 0.79–0.98) for 1 segmental or 2 subsegmental mismatches. Figure 2 illustrates the challenge of V/Q SPECT interpretation criteria.

View this table:
  • View inline
  • View popup
TABLE 1

Sensitivity, Specificity, and Likelihood Ratios of V/Q SPECT According to Criteria Tested

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Illustration of challenge of V/Q SPECT interpretation criteria. Axial, coronal, and sagittal V/Q SPECT shows isolated mismatch defect in right lower lobe. According to criterion used, V/Q SPECT can be positive or negative for PE.

Receiver-operating-characteristic curves were generated according to the number of mismatches, regardless of their size (Fig. 3A) and the number of subsegmental mismatches or equivalent (considering 1 segmental mismatch equal to 2 subsegmental mismatches) (Fig. 3B). The areas under the curve were, respectively, 0.9374 and 0.9376. Considering these 2 curves, the best compromise sensitivity–specificity was achieved for 2 subsegmental mismatches or equivalent, corresponding to 1 segmental or 2 subsegmental mismatches.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Receiver-operating-characteristic curves generated according to number of mismatches regardless of their size (A) and number of subsegmental mismatches or equivalent (B).

Likelihood ratios with V/Q SPECT are presented in Table 1. The positive likelihood ratio using a diagnostic cutoff of 1 segmental or 2 subsegmental mismatches was 10.2 (95% CI, 6.5–16). The negative likelihood ratio was 0.09 (95% CI, 0.04–0.23). Figure 4 shows the curves generated from negative and positive likelihood ratios. Based on preimaging assessment of clinical probability, the risk of PE is about 10%, 30%, and more than 60% for a low, intermediate, and high probability, respectively (18). With a negative V/Q SPECT result, the posttest probability of PE was 0.010, 0.037, and 0.119 for a low, intermediate, and high probability. With a positive V/Q SPECT result, the posttest probability of PE was 0.531, 0.814, and 0.939 for a low, intermediate, and high probability.

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

Posttest probability of PE with negative V/Q SPECT findings and positive V/Q SPECT findings based on preimaging assessment of clinical probability.

DISCUSSION

In this study, we assessed different criteria for V/Q SPECT interpretation in the face of suspected PE using as a reference standard a validated independent diagnostic strategy. The best performance was achieved using a diagnostic cutoff of 1 segmental or 2 subsegmental mismatches, with sensitivity and specificity of 0.92 (95% CI, 0.84–1) and 0.91 (95% CI, 0.87–0.95), respectively.

Indeed, many studies have suggested that the transition from planar imaging to SPECT may improve the diagnostic performance of V/Q imaging for the diagnosis of PE. However, only sparse data based on an objective reference test are available, and the criteria used for interpretation varied widely (19).

Before integrating V/Q SPECT into routine practice, 3 validating steps are needed: the first step was the validation of V/Q SPECT accuracy compared with a validated diagnostic strategy, which was the aim of our previous study (8); the second step, addressed in this study, is the validation of interpretation criteria dedicated to V/Q SPECT; the last step will be a large management outcome study including V/Q SPECT in the diagnostic algorithm, in which patients with a negative diagnostic work-up would be left untreated and followed up over time.

Historical PIOPED studies used probabilistic interpretation, with results proposed on a scale from high to low probability (17). This terminology led to confusion for physicians and was probably partly responsible for the declining popularity of the V/Q scan. There is currently a consensus that V/Q SPECT readings should be binary: positive or negative. However, the diagnostic cutoff varies widely (19). Indeed, PE has been diagnosed according to different criteria in different studies, such as “1 mismatched defect, regardless of size” (9–11), “1 segmental mismatched defect” (12), or “2 mismatched segmental or subsegmental mismatched defects” (7). The European Association of Nuclear medicine also proposed criteria for reading V/Q SPECT scans in which PE is reported for a mismatch of at least “1 segment or 2 subsegments that conform to the pulmonary vascular anatomy” (13). However, these criteria were not validated on the basis of an objective reference standard.

In our study, the best diagnostic cutoff for the diagnosis of PE was 1 segmental or 2 subsegmental mismatches, with sensitivity and specificity of 0.92 (95% CI, 0.84–1) and 0.91 (95% CI, 0.87–0.95), respectively. These data are concordant with those previously published, reporting sensitivity and specificity of at least 90% in almost all studies (19). The main strength of our study is that we used as a reference standard an independent validated diagnostic strategy whose conclusions were not based on V/Q SPECT results.

Moreover, in our study, calculations of posttest probability using pretest probability and likelihood ratios according to the Bayes theorem showed that the diagnostic conclusions were satisfactory when clinical assessment was not discordant with the V/Q SPECT interpretation. However, the posttest probability of PE with a negative V/Q SPECT result but a high clinical probability was 12%, and the posttest probability with a positive V/Q SPECT result but a low clinical probability was 53%. These data are concordant with previously published studies, especially with CT pulmonary angiography. In the PIOPED II trial, CT pulmonary angiography readings were false-positive 42% of the time among patients with a low clinical probability of PE and false-negative 40% of the time among patients with a high clinical probability (20). Thus, when the clinical probability and the results of imaging procedures are discordant, the posttest probability of PE is probably neither sufficiently low nor sufficiently high to permit therapeutic decisions. Under these circumstances, additional objective testing is necessary.

Our study had some potential limitations. First, the subset in whom SPECT was analyzed did not include “all comers” but only patients with either a high clinical probability or positive d-dimer result and negative sonography results, thus reducing the number of patients with PE. On the other hand, given the diagnostic algorithm, this limitation is also an advantage because the subset represents the group of patients who would have V/Q SPECT using a diagnostic algorithm that has sonography as a first examination. One other limitation of this study could be the potential correlation between the planar V/Q scan used in the reference standard and V/Q SPECT. Indeed, because these 2 modalities assess the same physiopathologic process with different technical approaches, the accuracy of V/Q SPECT could have been artificially increased. However, our gold standard was not only V/Q planar scanning but also a sequential diagnostic algorithm including clinical probability, d-dimer testing, sonography, and MDCT, along with a formal 3-mo clinical follow-up. Thus, we compared V/Q SPECT results to a reference diagnostic strategy, limiting the impact of a possible correlation between planar and SPECT acquisition. Finally, anatomic imaging was not used for V/Q SPECT interpretation. Indeed, the aim of the study was to assess the performance of V/Q SPECT as the cornerstone of the PE diagnosis. Moreover, the impact of anatomic imaging on the interpretation of V/Q scans is not clearly established. The development of dual-modality imaging with SPECT/CT, which provides simultaneous tomographic anatomic imaging, may improve the performance of V/Q SPECT and might be evaluated in future studies.

Besides its diagnostic performance, V/Q scanning offers many advantages over MDCT. First, the radiation exposure is lower with V/Q scanning, particularly to the female breast. Second, V/Q scanning can be proposed for almost any patient. In the PIOPED 2 study, over 40% of patients did not undergo MDCT, mainly because of renal impairment or contrast allergy. Third, V/Q SPECT might be the best-adapted modality for follow-up, especially for the diagnosis of recurrence or for therapeutic assessment.

CONCLUSION

From these considerations and using a diagnostic cutoff of 1 segmental or 2 subsegmental mismatches, V/Q SPECT seems able to position itself as the first imaging test in patients with suspected PE. The last step now required is to perform a large management outcome study with venous thromboembolism recurrence and mortality at 3 mo as outcome measures to definitely confirm these data.

DISCLOSURE

The costs of publication of this article were defrayed in part by the payment of page charges. Therefore, and solely to indicate this fact, this article is hereby marked “advertisement” in accordance with 18 USC section 1734. This study was partially funded by the Projet Hospitalier de Recherche Clinique 2004 (French Ministry of Health). No other potential conflict of interest relevant to this article was reported.

Footnotes

  • Published online May 1, 2013.

  • © 2013 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

REFERENCES

  1. 1.↵
    Value of the ventilation/perfusion scan in acute pulmonary embolism: results of the Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED). The PIOPED Investigators. JAMA. 1990;263:2753–2759.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Brenner DJ,
    2. Hall EJ
    . Computed tomography: an increasing source of radiation exposure. N Engl J Med. 2007;357:2277–2284.
    OpenUrlCrossRefPubMed
  3. 3.↵
    1. Valentin J
    . Managing patient dose in multi-detector computed tomography (MDCT). ICRP Publication 102. Ann ICRP. 2007;37:1–79.
    OpenUrlFREE Full Text
  4. 4.
    Radiation dose to patients from radiopharmaceuticals: addendum 3 to ICRP Publication 53—ICRP Publication 106. Approved by the Commission in October 2007. Ann ICRP. 2008;38:1–197.
    OpenUrlFREE Full Text
  5. 5.↵
    1. Hurwitz LM,
    2. Yoshizumi TT,
    3. Goodman PC,
    4. et al
    . Radiation dose savings for adult pulmonary embolus 64-MDCT using bismuth breast shields, lower peak kilovoltage, and automatic tube current modulation. AJR. 2009;192:244–253.
    OpenUrlCrossRefPubMed
  6. 6.↵
    1. Le Gal G,
    2. Kovacs MJ,
    3. Carrier M,
    4. et al
    . Validation of a diagnostic approach to exclude recurrent venous thromboembolism. J Thromb Haemost. 2009;7:752–759.
    OpenUrlCrossRefPubMed
  7. 7.↵
    1. Bajc M,
    2. Olsson B,
    3. Palmer J,
    4. Jonson B
    . Ventilation/perfusion SPECT for diagnostics of pulmonary embolism in clinical practice. J Intern Med. 2008;264:379–387.
    OpenUrlCrossRefPubMed
  8. 8.↵
    1. Le Duc-Pennec A,
    2. Le Roux PY,
    3. Cornily JC,
    4. et al
    . Diagnostic accuracy of single-photon emission tomography ventilation/perfusion lung scan in the diagnosis of pulmonary embolism. Chest. 2012;141:381–387.
    OpenUrlCrossRefPubMed
  9. 9.↵
    1. Howarth DM,
    2. Booker JA,
    3. Voutnis DD
    . Diagnosis of pulmonary embolus using ventilation/perfusion lung scintigraphy: more than 0.5 segment of ventilation/perfusion mismatch is sufficient. Intern Med J. 2006;36:281–288.
    OpenUrlCrossRefPubMed
  10. 10.
    1. Collart JP,
    2. Roelants V,
    3. Vanpee D,
    4. et al
    . Is a lung perfusion scan obtained using single photon emission computed tomography able to improve the radionuclide diagnosis of pulmonary embolism? Nucl Med Commun. 2002;23:1107–1113.
    OpenUrlCrossRefPubMed
  11. 11.↵
    1. Leblanc M,
    2. Leveillee F,
    3. Turcotte E
    . Prospective evaluation of the negative predictive value of V/Q SPECT using 99mTc-Technegas. Nucl Med Commun. 2007;28:667–672.
    OpenUrlCrossRefPubMed
  12. 12.↵
    1. Palla A,
    2. Tumeh SS,
    3. Nagel JS,
    4. Meyerovitz MF,
    5. Goldhaber SZ,
    6. Holman BL
    . Detection of pulmonary perfusion defects by single photon emission computed tomography (SPECT). J Nucl Med Allied Sci. 1988;32:27–32.
    OpenUrlPubMed
  13. 13.↵
    1. Bajc M,
    2. Neilly JB,
    3. Miniati M,
    4. Schuemichen C,
    5. Meignan M,
    6. Jonson B
    . EANM guidelines for ventilation/perfusion scintigraphy: Part 1. Pulmonary imaging with ventilation/perfusion single photon emission tomography. Eur J Nucl Med Mol Imaging. 2009;36:1356–1370.
    OpenUrlCrossRefPubMed
  14. 14.↵
    1. Salaun PY,
    2. Couturaud F,
    3. Le Duc-Pennec A,
    4. et al
    . Noninvasive diagnosis of pulmonary embolism. Chest. 2011;139:1294–1298.
    OpenUrlCrossRefPubMed
  15. 15.↵
    1. Wells PS,
    2. Hirsh J,
    3. Anderson DR,
    4. et al
    . A simple clinical model for the diagnosis of deep-vein thrombosis combined with impedance plethysmography: potential for an improvement in the diagnostic process. J Intern Med. 1998;243:15–23.
    OpenUrlCrossRefPubMed
  16. 16.↵
    1. Le Gal G,
    2. Righini M,
    3. Sanchez O,
    4. et al
    . A positive compression ultrasonography of the lower limb veins is highly predictive of pulmonary embolism on computed tomography in suspected patients. Thromb Haemost. 2006;95:963–966.
    OpenUrlPubMed
  17. 17.↵
    1. Gottschalk A,
    2. Sostman HD,
    3. Coleman RE,
    4. et al
    . Ventilation-perfusion scintigraphy in the PIOPED study. Part II. Evaluation of the scintigraphic criteria and interpretations. J Nucl Med. 1993;34:1119–1126.
    OpenUrlAbstract/FREE Full Text
  18. 18.↵
    1. Ceriani E,
    2. Combescure C,
    3. Le Gal G,
    4. et al
    . Clinical prediction rules for pulmonary embolism: a systematic review and meta-analysis. J Thromb Haemost. 2010;8:957–970.
    OpenUrlPubMed
  19. 19.↵
    1. Stein PD,
    2. Freeman LM,
    3. Sostman HD,
    4. et al
    . SPECT in acute pulmonary embolism. J Nucl Med. 2009;50:1999–2007.
    OpenUrlAbstract/FREE Full Text
  20. 20.↵
    1. Stein PD,
    2. Fowler SE,
    3. Goodman LR,
    4. et al
    . Multidetector computed tomography for acute pulmonary embolism. N Engl J Med. 2006;354:2317–2327.
    OpenUrlCrossRefPubMed
  • Received for publication September 10, 2012.
  • Accepted for publication January 29, 2013.
View Abstract
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 54 (7)
Journal of Nuclear Medicine
Vol. 54, Issue 7
July 1, 2013
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
V/Q SPECT Interpretation for Pulmonary Embolism Diagnosis: Which Criteria to Use?
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
V/Q SPECT Interpretation for Pulmonary Embolism Diagnosis: Which Criteria to Use?
Pierre-Yves Le Roux, Philippe Robin, Aurélien Delluc, Ronan Abgral, Alexandra Le Duc-Pennec, Emmanuel Nowak, Francis Couturaud, Grégoire Le Gal, Pierre-Yves Salaun
Journal of Nuclear Medicine Jul 2013, 54 (7) 1077-1081; DOI: 10.2967/jnumed.112.113639

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
V/Q SPECT Interpretation for Pulmonary Embolism Diagnosis: Which Criteria to Use?
Pierre-Yves Le Roux, Philippe Robin, Aurélien Delluc, Ronan Abgral, Alexandra Le Duc-Pennec, Emmanuel Nowak, Francis Couturaud, Grégoire Le Gal, Pierre-Yves Salaun
Journal of Nuclear Medicine Jul 2013, 54 (7) 1077-1081; DOI: 10.2967/jnumed.112.113639
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Lung Scintigraphy for Pulmonary Embolism Diagnosis in COVID-19 Patients: A Multicenter Study
  • Pulmonary Scintigraphy for the Diagnosis of Acute Pulmonary Embolism: A Survey of Current Practices in Australia, Canada, and France
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles

Keywords

  • V/Q SPECT
  • pulmonary embolism
  • criteria
SNMMI

© 2025 SNMMI

Powered by HighWire