Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting Report

Deriving resolution-compensated PET images from the GTM partial volume correction method

Olivier Rousset, Ayon Nandi, Yansong Zhu, Arman Rahmim and Dean Wong
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 1399;
Olivier Rousset
1Russell H. Morgan Department of Radiology and Radiological Sciences Johns Hopkins University Baltimore MD United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ayon Nandi
1Russell H. Morgan Department of Radiology and Radiological Sciences Johns Hopkins University Baltimore MD United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yansong Zhu
2Radiology and Physics University of British Columbia Vancouver BC Canada
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Arman Rahmim
2Radiology and Physics University of British Columbia Vancouver BC Canada
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Dean Wong
1Russell H. Morgan Department of Radiology and Radiological Sciences Johns Hopkins University Baltimore MD United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

1399

Introduction: PET suffers from spatial resolution limitations and the ensuing partial volume effects (PVE) greatly impact accurate tracer quantification. Partial volume correction (PVC) methods include region-based (ROI) and voxel-based (image) approaches. While PET has commonly involved regional (ROI) assessment of activity concentrations due to individual voxel noise, it can be desirable to obtain actual images obtained with PVC for further inspection and analysis.

Methods: While the region-based geometric transfer matrix (GTM) method [1] is widely used for PVC, it has sometimes been toned down for only providing ROI values, and not being able to provide actual images corrected for PVE. At the same time, images corrected for PVE using the GTM-PVC method can be produced following some extra computing steps. We applied our GTM-PVC method [1] to a cohort of cognitively normal volunteers (N=10) and to patients diagnosed with Alzheimer’s disease (N=10), who underwent amyloid load assessment using two different PET tracers ([11C]-PiB, and [18F]-florbetapir). Dynamic PET data were acquired on a GE Advance® scanner, and the last 4 frames from the 70min studies, assumed to be in a steady state, were averaged and used for analysis. MRI data were used to build individual tracer models (Fig. 1) derived from a cloud-based service [2] using multi-atlas segmentation approach [3]. PET simulations were carried out to derive GTM data for each of the 31 regions (VOI) labeled in the tracer model (Fig. 1). Subject-specific MRI-derived ROI templates were built upon thresholding (50%) each volume-of-interest (VOI)’s axial component of the regional spread function [4]. Correction maps derived from the GTM-PVC data were then generated using the concept of apparent recovery coefficient [5] [AR1] and applied to the original PET data to yield PVC images (GTM-PIX, Fig. 2). After applying the GTM-PVC method, corrected ROI values were then compared with the values obtained from application of the same ROI template to the GTM-based pixel (GTM-PIX) images.

Results: Regional values obtained from the GTM-PIX method were compared with regional values obtained after GTM-PVC using the same ROI template. Regional activity concentrations from the GTM-PIX PVC method were found to be in excellent agreement with regional values obtained with the GTM-PVC method, typically showing close to one-on-one correlation, with R2 values typically > 0.99 (Fig. 3).

Conclusions: We show how easily it is to derive images from the GTM correction method, not requiring any additional input, and that can be very easily implemented following application of the GTM PVC method. This method provides results consistent with those obtained with the GTM-PVC after sampling the GTM-PIX images with the same ROI templates. Acknowledgements: This work was supported in part by R21 grant no. AG056142 from the National Institute on Aging. References: [1] Rousset et al., J Nuc Med (1998); [2] Mori, S. et al., Computing in Science & Engineering (2016); [3] Wang, H. et al., Inf Process Med Imaging (2013); [4] Rousset et al., J Nucl Med (2008); [5] Rousset et al., Comp Med Imag Graph (1993)

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 61, Issue supplement 1
May 1, 2020
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Deriving resolution-compensated PET images from the GTM partial volume correction method
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Deriving resolution-compensated PET images from the GTM partial volume correction method
Olivier Rousset, Ayon Nandi, Yansong Zhu, Arman Rahmim, Dean Wong
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 1399;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Deriving resolution-compensated PET images from the GTM partial volume correction method
Olivier Rousset, Ayon Nandi, Yansong Zhu, Arman Rahmim, Dean Wong
Journal of Nuclear Medicine May 2020, 61 (supplement 1) 1399;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

  • Rest Dose Spillover Correction of Stress Blood Flow Measurements in Digital Rb-82 Myocardial Perfusion PET/CT Imaging
  • Radiolabeled hyaluronic acid (HA) fragments for lymphatic imaging
  • Simplifying and Confirming Ketosis: A Quality Improvement Initiative in Cardiac Sarcoid Assessment
Show more

Data Analysis & Management (Poster Session)

  • Activity assays for the alpha-emitting radionuclide Ra-224 adsorbed onto CaCO3 microparticles
  • 5-year progress on imaging performance of commercial PET scanners: a multi-center study towards harmonization of FDG-PET
  • A Comparison of Semi-Automated Brown Adipose Tissue Segmentation Methods