Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportPhysics, Instrumentation & Data Sciences

A Retrospective Study of Physiologic Markers to Assess Radiopharmaceutical Infiltration Compared to External Injection Monitoring

Dustin Osborne, Sneha Thakur and Shelley Acuff
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 1190;
Dustin Osborne
1University of Tennessee: Graduate School of Medici Knoxville TN United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Sneha Thakur
2Radiology University of Tennessee: Graduate School of Medici Knoxville TN United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Shelley Acuff
3UT Medical Center Maynardville TN United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

1190

Background: Infiltration is a significant issue in PET/CT imaging because it can lead to uncertainty in the accuracy of values recorded from regions of interest drawn on the data and underestimation of standard uptake values (SUVs). This issue is further complicated because the infiltration site is often not visible in the PET/CT field of view. A commercial device is available that can be used for injection monitoring as well as providing a score related to the quality of the injection (Lara, Lucerno Dynamics, LLC). This study examines physiologic regions drawn in PET data and compared between severely infiltrated injection and good quality injections to determine if any physiologic parameters alone can serve as an indicator of infiltration. Methods: The first phase of this study reviewed 897 SUV max values reported from the right lobe of the liver as this is the most commonly reported SUV for routine PET. Reported SUVs were compared to injection scoring from the injection monitoring device to determine if any significant correlation existed. The second phase of the study examined additional physiological parameters. Five patients (5 infiltrated injections, 5 good quality injections )were identified and regions of interest (ROIs) drawn on the areas listed in the attached table. The five infiltrated studies were the five worst infiltrations recorded at our site over a period of approximately 1.5 years while the 5 good quality injection were five of our best over the same period. Statistical analysis using t-tests were performed to compare means. Results: Phase one liver assessments indicated no significant correlations between injection quality score and right hepatic lobe SUV maximum measurements. Comparison of means in the expanded ROI analysis in phase two indicated that statistically significant differences in mean (p<0.05) were only observed in the cerebellum, vertebrae, and lung. Although these showed statistical significance there is still significant overlap of measured values between scores that indicate significant infiltration and those that indicate good quality injections. Measurements of the cerebellum showed the greatest separation of patient populations.

Conclusions: Physiologic parameters may be helpful in assessing potential infiltration, however, commonly reported areas such as the liver do not appear to have any significant correlation with injection quality making it an unreliable marker of infiltration. Other regions may be more useful, however, the overlap of values for infiltrated and non-infiltrated scans make it difficult to simply assign a threshold for rapid assessment. External injection monitoring seems to be the most reliable method for assessing PET radiopharmaceutical injection quality for individual patients.

View this table:
  • View inline
  • View popup

Region List for SUV Assessment

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 60, Issue supplement 1
May 1, 2019
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
A Retrospective Study of Physiologic Markers to Assess Radiopharmaceutical Infiltration Compared to External Injection Monitoring
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
A Retrospective Study of Physiologic Markers to Assess Radiopharmaceutical Infiltration Compared to External Injection Monitoring
Dustin Osborne, Sneha Thakur, Shelley Acuff
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 1190;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
A Retrospective Study of Physiologic Markers to Assess Radiopharmaceutical Infiltration Compared to External Injection Monitoring
Dustin Osborne, Sneha Thakur, Shelley Acuff
Journal of Nuclear Medicine May 2019, 60 (supplement 1) 1190;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Physics, Instrumentation & Data Sciences

  • 3D Structural Convolutional Sparse Coding for PET Image Reconstruction
  • Exploration of Multi-objective Optimization with Genetic Algorithms for PET Image Reconstruction
  • AI-based methods for nuclear-medicine imaging: Need for objective task-specific evaluation
Show more Physics, Instrumentation & Data Sciences

Data Analysis & Management Posters

  • Evaluation of Quantitative Whole Body Dynamic FDG-PET Using Block Sequence Regularized Expectation Maximization (BSREM) Reconstruction
  • Feasibility of 18F-THK5351 PET quantitation using the Centiloid scale
  • NaF-PET/CT for assessment of temporomandibular joint osseous activity in rheumatoid arthritis patients and healthy subjects
Show more Data Analysis & Management Posters

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire