Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis Track

Application of Texture and Radiomics Analysis to Clinical Myocardial Perfusion SPECT Imaging

Saeed Ashrafinia, Pejman Dalaie, Rongkai Yan, Peng Huang, Martin Pomper, Thomas Schindler and Arman Rahmim
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 94;
Saeed Ashrafinia
4Electrical and Computer Engineering Johns Hopkins University Baltimore MD United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Pejman Dalaie
1Johns Hopkins Hospital Baltimore MD United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Rongkai Yan
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Peng Huang
3Johns Hopkins University Baltimore MD United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Martin Pomper
2Johns Hopkins Medical Institutions Baltimore MD United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Thomas Schindler
3Johns Hopkins University Baltimore MD United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Arman Rahmim
3Johns Hopkins University Baltimore MD United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
Loading

Abstract

94

Objectives: Despite relatively low resolution of SPECT images, recent studies in brain DAT SPECT [1, 2] have shown promising results in heterogeneity and radiomics analysis of SPECT images. Nonetheless, cardiac SPECT radiomics remain to be explored. Myocardial perfusion SPECT (MPS) scan is an established diagnostic test for patients suspected of coronary artery calcification (CAD). In this study, we aimed to utilize a radiomics workflow including identification of appropriate settings for systematic MPS radiomics. Specifically, we investigate prediction of coronary artery calcification (CAC) obtained from CT. CAC scoring is not readily available in the community centers and is not currently reimbursed by CMS, but shown to offer incremental diagnosis information over MPS for identifying patients with significant CAD and negative MPS results [3]. Methods We identified 372 patients with normal (non-ischemic) stress 99mTc-Sestamibi MPS scans with consensus reading. Iterative reconstruction images (attenuation-corrected, isotropic-cubic-voxels) were verified by a NM physician to be free from fixed perfusion defect and artifactual attenuation. Semi-automatic segmentation was performed by a radiologist and 7 regions-of-interests were generated: myocardium, 3 vascular segments (LAD-LCX-RCA) from the vascular map, and the 17-segment polar plot. Our radiomics framework is in compliance with the Image Biomarker Standardization Initiative [4] to ensure the reproducibility of the study. We performed two feature elimination phases to prevent overfitting: pre- and post-feature calculation. ROIs of MPS images have arbitrary units, fixed shape and isotropic voxels. This helps to eliminate morphological, local intensity (peak), and all higher order 2D features pre-calculation, leaving 188 features. Arbitrary voxel intensities suggest discretizing images via fixed number of bins (FNB) method (as opposed to fixed bin-size). We discretized images into 8 different grey-levels (GLs) (22,&#8943;,29), and evaluated 188×8 features for 7 ROIs. Multiple correlation analysis with correction for multiple testing (Benjamini-Hutchberg false discovery rate (FDR), α=0.05) was subsequently performed between radiomic features and the CAC score for each 7 segments. Results Variance of each feature-GL-ROI was evaluated to assess the feasibility of features perform post-calculation elimination. 938 features had var<1e-5: (5, 6, 18, 39, 177, 205, 231, 257) feature-ROI pair for each GLs (22 to 29), respectively. Higher GLs often have more bins than the No. of voxels, resulting in very few columns in GLRLM, GLSZM, GLDZM, NGTDM and NGLDM; exhibiting very small variation. CAC data is highly prone to outliers; suggesting rank-correlation analysis. Most features are not reproducible to GL variations, and most significant correlations are seen in 16, 32 and 64 GLs. After FDR correction, the consistently significant features (FDR q-value<0.05) observed include: intensity skewness and GLCM cluster shade for RCA, and intensity at 90% vol. histogram for LCX. This analysis also showed LAD and RCA extracted from vascular plot had more significant correlation than bull’s eye plot (FDR q-value<0.05), while LCX from the latter plot is more significant. In the LAD ROI, apical thinning and slight overcorrection due to breast attenuation appears occasionally (118 cases) resulting in a cold uptake in apico-anterior wall. This generates a heterogeneity irrelevant to CAC, impacting the correlation, suggesting potentially removing the apex from LAD.

Conclusions: FNB discretization by 16 to 64 GLs is suggested for radiomics of MP SPECT images. Correlation analysis shows promising results in attributing radiomic features to CAC score. These results suggest that radiomic analysis has the potential to add diagnostic/prognostic value to standard MPS for wide clinical usage. Acknowledgement This work was in part supported by the 2017 Bradley-Alavi fellowship (Saeed Ashrafinia) from SNMMI.

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint
Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 59, Issue supplement 1
May 1, 2018
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Application of Texture and Radiomics Analysis to Clinical Myocardial Perfusion SPECT Imaging
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Application of Texture and Radiomics Analysis to Clinical Myocardial Perfusion SPECT Imaging
Saeed Ashrafinia, Pejman Dalaie, Rongkai Yan, Peng Huang, Martin Pomper, Thomas Schindler, Arman Rahmim
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 94;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Application of Texture and Radiomics Analysis to Clinical Myocardial Perfusion SPECT Imaging
Saeed Ashrafinia, Pejman Dalaie, Rongkai Yan, Peng Huang, Martin Pomper, Thomas Schindler, Arman Rahmim
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 94;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Figures & Data
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis Track

  • Deep Learning Based Kidney Segmentation for Glomerular Filtration Rate Measurement Using Quantitative SPECT/CT
  • Comparison of 22 partial volume correction methods for amyloid PET imaging with 11C-PiB
  • The Benefit of Time-of-Flight in Digital Photon Counting PET Imaging: Physics and Clinical Evaluation
Show more Instrumentation & Data Analysis Track

Computer & Instrumentation Council YIA Symposium

  • Brain PET dose reduction using a shallow artificial neural network
  • PET Imaging of Pancreatic β-Cell Mass with 11C-(+)-PHNO: Determination of the appropriate approach for quantitative analysis
  • Characterizing the TOF performance of the PennPET Explorer scanner
Show more Computer & Instrumentation Council YIA Symposium

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire