Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis Track

Bias reduction in Y-90 PET with reconstruction that relaxes the non-negativity constraint

Hongki Lim, Kyungsang Kim, Quanzheng Li, Jeffrey Fessler and Yuni Dewaraja
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 580;
Hongki Lim
2University of Michigan Ann Arbor MI United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kyungsang Kim
1Massachusetts General Hospital Boston MA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Quanzheng Li
1Massachusetts General Hospital Boston MA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jeffrey Fessler
2University of Michigan Ann Arbor MI United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yuni Dewaraja
2University of Michigan Ann Arbor MI United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

580

Objectives: Y-90 PET is complex due to the very low probability positrons in the presence of increased singles events from bremsstrahlung photons and gammas from natural radioactivity in Lu based crystals used in some PET systems. Due to these attributes of Y-90, positive bias in cold regions and underestimation in hot regions of interest are reported in many Y-90 PET papers when using conventional EM reconstruction. This bias is introduced by the current standard PET reconstruction algorithms that enforce a nonnegativity constraint in the image domain. In this work, we evaluate image reconstruction algorithms that relax this constraint, including a method that we recently proposed, for potential reduction of bias in the low count-rate setting clinically realistic in Y-90 PET.

Methods: We used an anthropomorphic liver/lung torso phantom with total activity and distribution that is clinically realistic for imaging following radioembolization with Y-90 microspheres: 5% lung shunt, 1.2 MBq/mL in liver, 3 hepatic lesions (8 and 14 mL spheres, 30 mL ovoid) of 6.5 MBq/mL. The phantom was scanned for 30 minutes on a Siemens Biograph mCT PET/CT on day 0 and day 3 with total activity of 2.0 and 1.0 GBq respectively. Four different reconstruction algorithms were implemented in-house: (1) Standard Expectation Maximization (EM) algorithm used in the clinic, (2) regularized Separable Paraboloidal Surrogates (SPS) algorithm, (3) regularized NEG-ML-Reg algorithm and (4) regularized Alternating Direction Method of Multipliers (ADMM-Reg) algorithm. EM and SPS enforce the non-negativity constraint in the image domain. NEG-ML, where Poisson likelihood function is replaced by Gaussian distribution when the estimated measurement is below the switching parameter, has been proposed for the bias reduction in low-count-rate settings. ADMM(-Reg) is an algorithm that we recently proposed for the reduction of bias in Y-90 PET. The algorithm relaxes the conventional image-domain nonnegativity constraint by instead imposing a positivity constraint on the predicted measurement (projection) mean. The advantage of ADMM(-Reg) over NEG-ML(-Reg) is the absence of parameter tunning. Neither NEG-ML-Reg or ADMM-Reg has been evaluated previously with measured Y-90 PET data. We evaluate each algorithm by calculating the contrast recovery (relative to truth) of the hepatic lesions and the relative standard deviation of the liver background.

Results: We compared 10th iterations of EM to the 100th iterations of regularized methods (SPS-Reg, NEG-ML-Reg, ADMM-Reg) because EM algorithm without regularization needs to stop before convergence to have an acceptable noise level. Between regularized methods (2) - (4), ADMM-Reg achieved highest contrast recovery in both data acquisition points (day 0, day 3). The average of 3 hepatic lesions contrast recovery in day 0 was 81%, 72%, 65% and 61% when the image was reconstructed using ADMM-Reg, NEG-ML-Reg, SPS-Reg and EM respectively. ADMM-Reg also gave the highest relative standard deviation, but this can be controlled by increasing the value of the regularization parameter. We also visually compared the reconstructed images with patient data. ADMM and NEG-ML achieved higher contrast between enhancing and necrotic regions of a lesion.

Conclusions: Quantification of Y-90 PET reconstruction is enhanced by allowing negative values in image domain. Phantom measurements show that our implementation (ADMM-Reg) gave highest contrast recovery at the cost of increased noise, which, however can be controlled by regularization. Research Support: NIH R01EB022075

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 59, Issue supplement 1
May 1, 2018
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Bias reduction in Y-90 PET with reconstruction that relaxes the non-negativity constraint
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Bias reduction in Y-90 PET with reconstruction that relaxes the non-negativity constraint
Hongki Lim, Kyungsang Kim, Quanzheng Li, Jeffrey Fessler, Yuni Dewaraja
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 580;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Bias reduction in Y-90 PET with reconstruction that relaxes the non-negativity constraint
Hongki Lim, Kyungsang Kim, Quanzheng Li, Jeffrey Fessler, Yuni Dewaraja
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 580;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis Track

  • Deep Learning Based Kidney Segmentation for Glomerular Filtration Rate Measurement Using Quantitative SPECT/CT
  • The Benefit of Time-of-Flight in Digital Photon Counting PET Imaging: Physics and Clinical Evaluation
  • Preclinical validation of a single-scan rest/stress imaging technique for 13NH3 cardiac perfusion studies
Show more Instrumentation & Data Analysis Track

Quantitation in Reconstruction (Image Generation)

  • Three-fold reduction in pediatric PET dose by advanced image reconstruction without loss of diagnostic and quantitative performance
  • Improving the sensitivity of Molecular Breast Imaging using a novel detector response function
  • Comparison of Rotation-based and Non-rotation-based Projectors for Image reconstruction in Mini-EXPLORER II
Show more Quantitation in Reconstruction (Image Generation)

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire