Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis Track

Time-Varying Kinetic Modeling of High Temporal-Resolution Dynamic 18F-FDG PET Data for Multiparametric Imaging

Guobao Wang, Souvik Sarkar, Edward Kim and Ramsey Badawi
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 503;
Guobao Wang
1University of California - Davis Sacramento CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Souvik Sarkar
1University of California - Davis Sacramento CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Edward Kim
1University of California - Davis Sacramento CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Ramsey Badawi
1University of California - Davis Sacramento CA United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

503

Objectives: Early-dynamic 18F-FDG PET has the potential to derive blood flow without the need for a flow-specific radiotracer. All existing studies used a temporal resolution of 5-10 seconds and standard compartmental modeling that assumes time-constant kinetics. The FDG blood-to-tissue delivery rate K1 was considered as a surrogate of blood flow. However, this method can be only effective for regions such as aggressive tumors that have a high FDG extraction fraction and is ineffective for regions of low FDG-extraction. We propose to use high temporal-resolution (HTR) dynamic data acquisition to divide the tracer uptake period into a capillary transport phase and a tissue uptake phase. Blood flow can then be modeled independently of FDG extraction by using a time-varying kinetic model. The objective of this study is to test the validity of this model in HTR early-dynamic FDG-PET data. Methods: Twelve dynamic 18F-FDG PET/CT patient scans with the kidneys in the field of view of PET were included in this study. Dynamic PET data were acquired in list-mode format and binned into HTR time frames (2 seconds per frame) for the early 2 minutes post tracer injection. Regional time activity curves were extracted from dynamic PET images in the region of renal cortex and fit using two different kinetic models: standard one-tissue compartmental model with time-constant kinetics and a new time-varying compartmental model that allows different kinetic constants in the vascular phase and tissue phase. The transit time Tc, blood flow F and extraction fraction E were estimated from fitting of the time activity curve using the derived analytical model equation and a basis-function optimization algorithm. FDG delivery rate K1 was calculated by K1=FE. These two kinetic models were compared for curve fitting using the Akaike information criterion (AIC) and F test. Statistical association of different kinetic parameters was analyzed using the Pearson correlation analysis. Results: The time-varying kinetic model fit the HTR time activity curves more closely than standard time-constant kinetic model, particularly for the peak values. Statistical quality metrics showed the time-varying model achieved lower AIC and higher F values in all patients, meaning better fit quality by the new model. Renal extraction fraction of FDG was relatively low (E=35±10%). The estimated transit time was Tc=11±3 seconds. Renal FDG K1 was 0.65±0.14 mL/g/min and blood flow F was 1.94±0.53 mL/g/min by the time-varying model. FDG K1 by the time-varying model was correlated with K1 by the traditional time-constant compartmental model (r=0.68, p=0.02). Neither of the two K1 estimates correlated with blood flow F (r=0.23, p=0.48; r=0.20, p=0.54), indicating that FDG K1 and blood flow reflect different physiological processes in renal cortex. Conclusions: HTR early-dynamic FDG PET data favors time-varying compartmental modeling over standard time-constant compartmental modeling. This new method allows separate modeling of blood flow and FDG K1 and offers the promise of adding quantitative perfusion imaging to existing metabolic FDG-PET imaging to enable single-tracer multiparametric imaging. This study focused on renal cortex for demonstrating the feasibility but the method is applicable to other organs and in principle to any intravenously delivered radiotracer. While extension of the method for parametric imaging can be challenging because of high noise associated with individual image voxels, the emerging EXPLORER scanner has a much higher sensitivity than standard clinical PET scanners and provides a great opportunity for voxel-wise implementation of time-varying kinetic modeling. Our future work will exploit this modeling approach for total-body perfusion imaging on the EXPLORER and validate it against standard blood flow tracers. Research Support: This work is supported in part by NIH R21 HL 131385.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 59, Issue supplement 1
May 1, 2018
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Time-Varying Kinetic Modeling of High Temporal-Resolution Dynamic 18F-FDG PET Data for Multiparametric Imaging
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Time-Varying Kinetic Modeling of High Temporal-Resolution Dynamic 18F-FDG PET Data for Multiparametric Imaging
Guobao Wang, Souvik Sarkar, Edward Kim, Ramsey Badawi
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 503;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Time-Varying Kinetic Modeling of High Temporal-Resolution Dynamic 18F-FDG PET Data for Multiparametric Imaging
Guobao Wang, Souvik Sarkar, Edward Kim, Ramsey Badawi
Journal of Nuclear Medicine May 2018, 59 (supplement 1) 503;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • Quantitative PET imaging and modeling of molecular blood-brain barrier permeability
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis Track

  • Deep Learning Based Kidney Segmentation for Glomerular Filtration Rate Measurement Using Quantitative SPECT/CT
  • The Benefit of Time-of-Flight in Digital Photon Counting PET Imaging: Physics and Clinical Evaluation
  • Preclinical validation of a single-scan rest/stress imaging technique for 13NH3 cardiac perfusion studies
Show more Instrumentation & Data Analysis Track

Kinetic Modeling of Brain PET Studies

  • A comparison of kinetic models for PET imaging of cortical dopamine release induced by a task.
  • Kinetic modeling and test-retest variability of the M1 muscarinic acetylcholine receptor PET radiotracer 11C-LSN3172176 in humans
  • Direct Parametric Reconstruction for Improved Characterization of Neurotransmitter Release using Dynamic PET
Show more Kinetic Modeling of Brain PET Studies

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire