Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis Track

Adaptive PSF Modeling for Enhanced Heterogeneity Quantification in Oncologic PET Imaging

Saeed Ashrafinia, Esther Mena, Hassan Mohy-ud-Din, Abhinav Jha, Rathan Subramaniam and Arman Rahmim
Journal of Nuclear Medicine May 2016, 57 (supplement 2) 479;
Saeed Ashrafinia
5Radiology and Radiological Sciences Johns Hopkins University School of Medicine Baltimore MD United States
4Electrical and Computer Engineering Johns Hopkins University Baltimore MD United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Esther Mena
6NIH Silver Spring MD United States
2Johns Hopkins Baltimore MD United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hassan Mohy-ud-Din
8Yale University New Haven CT United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Abhinav Jha
1John Hopkins Baltimore MD United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Rathan Subramaniam
7The Johns Hopkins University Baltimore MD United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Arman Rahmim
3Johns Hopkins University Baltimore MD United States
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

479

Objectives Point-spread function (PSF) modeling, also known as resolution Modeling (RM), is a reconstruction-based partial volume correction (PVC) method. Unlike post-reconstruction PVC, it models resolution degradation phenomena within the reconstruction step. Past and ongoing studies have overwhelmingly focused on the impact of PSF modeling on common measures such as SUVmean and SUVmax. This study, by contrast, aims to investigate the impact of incorporating varying PSF kernels, enabling under- and overestimation of the true PSF, and study their effect on heterogeneity quantification.

Methods Images from twelve head and neck cancer patients with baseline 18F-FDG PET images (14.9±4.1 mCi) with lesions larger than 8mL (of varying heterogeneity extents) were considered. We subsequently used these images as the reference truth, and simulated clinically realistic data (100 noise realizations) for clinical scanner geometry. This incorporated normalization, attenuation (using patient’s CT image), decay, and resolution degrading phenomena (including photon non-collinearity, inter-crystal penetration and scattering). We introduced controllable scaling factors to generate 10 analytically modeled asymmetric blurring kernels (incorporating abovementioned physical phenomena with additional scaling in extent), including no/full PSF modeling, as well as 4 underestimated and 4 overestimated kernels. Twelve tumor contours were delineated by a trained nuclear medicine physician and used for threshold-based tumor segmentation. For our proposed investigation, we performed Haralick analysis, which has increasing utility in the field of heterogeneity quantification. We extracted the gray-level co-occurrence matrix, utilizing 64 gray-level quantization and a distance of 1 (which were seen to results in optimized performance). We computed a number of Haralick measures, including: (1) energy, (2) entropy, (3) correlation, (4) contrast, (5) variance, (6) sum mean, (7) agreement, (8) cluster tendency, (9) homogeneity, (10) inverse variance and (11) dissimilarity, along with conventional mean uptake. For each metric, bias vs. noise (reproducibility) trade-off performance analysis was performed.

Results Entropy was the only metric depicting reproducibility consistently lower than conventional mean uptake (by 50-80%). The various metrics were found not to be overly sensitive to the range of no->underestimated>full PSF modeling, but responded to PSF overestimation. Specifically, energy and entropy resulted in poorer bias vs. reproducibility performance for PSF overestimation (50-100% degradation in bias for matched reproducibility). At the same time, and interestingly, dissimilarity, contrast, correlation, homogeneity and variance were often quantitatively enhanced due to PSF overestimation (20-40% improvement in reproducibility for matched bias). PSF modeling with increasing kernels widths results in two phenomena: (1) reduction of spatial noise (due to reduced voxel variance and increased inter-voxel covariance), and (2) increased edge artifacts. These two phenomena both impact texture quantification, and different texture measures are optimized differently as they quantify heterogeneity in different ways.

Conclusions In terms of quantitative bias vs. noise (reproducibility) trade-off performance, different texture metrics responded differently whether or not PSF overestimation was performed. ‘Entropy’ consistently outperformed conventional mean uptake analysis in terms of reproducibility. It along with ‘energy’ performed optimally when overestimation was not performed. This was in contrast to some other metrics that performed optimally when overestimation was utilized. These results are also linked to the performance of vendor PET images, as some parameterize the PSF kernels using Ge-68 point sources (with higher positron range) instead of 18F, thus implicitly implementing overestimated PSF kernels.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 57, Issue supplement 2
May 1, 2016
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Adaptive PSF Modeling for Enhanced Heterogeneity Quantification in Oncologic PET Imaging
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Adaptive PSF Modeling for Enhanced Heterogeneity Quantification in Oncologic PET Imaging
Saeed Ashrafinia, Esther Mena, Hassan Mohy-ud-Din, Abhinav Jha, Rathan Subramaniam, Arman Rahmim
Journal of Nuclear Medicine May 2016, 57 (supplement 2) 479;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Adaptive PSF Modeling for Enhanced Heterogeneity Quantification in Oncologic PET Imaging
Saeed Ashrafinia, Esther Mena, Hassan Mohy-ud-Din, Abhinav Jha, Rathan Subramaniam, Arman Rahmim
Journal of Nuclear Medicine May 2016, 57 (supplement 2) 479;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis Track

  • Deep Learning Based Kidney Segmentation for Glomerular Filtration Rate Measurement Using Quantitative SPECT/CT
  • Comparison of 22 partial volume correction methods for amyloid PET imaging with 11C-PiB
  • The Benefit of Time-of-Flight in Digital Photon Counting PET Imaging: Physics and Clinical Evaluation
Show more Instrumentation & Data Analysis Track

Image Generation: Quantitation topics in PET

  • TOF reconstruction for improved quantitative accuracy in PET/CT studies with misalignment
  • A fast dynamic PET simulator for improved kinetic modeling estimation
Show more Image Generation: Quantitation topics in PET

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire