Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis

Partial volume correction in small animal PET imaging incorporating total variation regularization

Lijun Lu, Debin Hu, Yanjiang Han, Chengwei Gu, Arman Rahmim, JIanhua Ma and Wufan Chen
Journal of Nuclear Medicine May 2014, 55 (supplement 1) 374;
Lijun Lu
1School of Biomedical Engineering, Southern Medical University, Guangzhou, China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Debin Hu
1School of Biomedical Engineering, Southern Medical University, Guangzhou, China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yanjiang Han
2PET Centres, Nanfang Hospital, Southern Medical University, Guangzhou, China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Chengwei Gu
1School of Biomedical Engineering, Southern Medical University, Guangzhou, China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Arman Rahmim
3Department of Radiology, Johns Hopkins University, Baltimore, MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
JIanhua Ma
1School of Biomedical Engineering, Southern Medical University, Guangzhou, China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Wufan Chen
1School of Biomedical Engineering, Southern Medical University, Guangzhou, China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

374

Objectives Partial volume correction (PVC) methods in emission tomography aim to achieve enhanced resolution and contrast recovery. However, traditional iterative deconvolution algorithms such as Van Cittert (VC) and Richardson-Lucy (RL) commonly amplify noise. The aim of this study was to incorporate total variation (TV) regularization within an iterative deconvolution framework and compare performance with a range of other PVC methods.

Methods In order to gain control over noise levels, we incorporated TV regularization within VC and RL deconvolution algorithms, and developed 3D VC-TV and RL-TV deconvolution. For validation, a 20 minutes NEMA NU 4-2008 IQ phantom with 18FDG as well as 10 minute tumor mouse data were acquired via the Siemens Inveon micro PET and were subsequently reconstructed using the OSEM algorithm. First, we optimized the full width at half maximum (FWHM) for RL and VC deconvolution. Then, we optimized the performance of the proposed TV regularized deconvolution (both VC-TV and RL-TV) and compared it with median root prior (MRP) based RL algorithm and El Naqa’s Bayesian deconvolution (Ba) algorithm. Comparisons included both visual assessment and recovery coefficient (RC) vs. standard deviation (SD) increase trade-off performance.

Results The experimental results demonstrated the proposed algorithms (both VC-TV and RL-TV)to achieve superior visual and quantitative performancecompared with the MRP-based RL and Bayesian deconvolution algorithms. In particular, the RL-TVexhibitedthe best compromise between noise attenuation and intensity recovery forthe images.

Conclusions The incorporation of total variation regularization in RL deconvolution algorithm is an efficient PVC method in 3D small animal PET imaging.

Research Support This work was supported by the 973 Program of China under grant no. 2010CB732504.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 55, Issue supplement 1
May 2014
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Partial volume correction in small animal PET imaging incorporating total variation regularization
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Partial volume correction in small animal PET imaging incorporating total variation regularization
Lijun Lu, Debin Hu, Yanjiang Han, Chengwei Gu, Arman Rahmim, JIanhua Ma, Wufan Chen
Journal of Nuclear Medicine May 2014, 55 (supplement 1) 374;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Partial volume correction in small animal PET imaging incorporating total variation regularization
Lijun Lu, Debin Hu, Yanjiang Han, Chengwei Gu, Arman Rahmim, JIanhua Ma, Wufan Chen
Journal of Nuclear Medicine May 2014, 55 (supplement 1) 374;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis

  • Assessment of AI-Enhanced Quantitative Volumetric MRI with Semi-Quantitative Analysis in 18F-FDG Metabolic Imaging for Alzheimer's Diagnosis.
  • Assessment of SUV consistency in PET/CT with annulus 68Ge DQA phantom
  • Assessment of Tumor Burden in Lymphoma Patients with Deauville Score 4 Disease on Post Therapy FDG PET
Show more Instrumentation & Data Analysis

Image Generation: PET Quantification

  • Quantitative brain PET imaging incorporating an anatomy-guided joint prior model
  • PSF modeling and anatomical prior design for improved quantitative PET using a dedicated NeuroPET/CT
  • A post-hoc methodology for harmonizing PET image reconstruction protocols
Show more Image Generation: PET Quantification

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire