Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis

MRI- and DTI-guided PET image reconstruction: Application to imaging with [11C]DPA-713

Hyeyun Jung, Jennifer Coughlin, Jing Tang, Christopher Endres, Yun Zhou, Susumu Mori, Dean Wong, Martin Pomper and Arman Rahmim
Journal of Nuclear Medicine May 2012, 53 (supplement 1) 375;
Hyeyun Jung
1Radiology, Johns Hopkins University, Baltimore, MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jennifer Coughlin
1Radiology, Johns Hopkins University, Baltimore, MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jing Tang
2Electrical Engineering, Oakland University, Rochester, MI
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Christopher Endres
1Radiology, Johns Hopkins University, Baltimore, MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yun Zhou
1Radiology, Johns Hopkins University, Baltimore, MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Susumu Mori
1Radiology, Johns Hopkins University, Baltimore, MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Dean Wong
1Radiology, Johns Hopkins University, Baltimore, MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Martin Pomper
1Radiology, Johns Hopkins University, Baltimore, MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Arman Rahmim
1Radiology, Johns Hopkins University, Baltimore, MD
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

375

Objectives To investigate the use of anatomy-assisted PET image reconstruction using modalities of MRI and diffusion tensor imaging (DTI) as applied to parametric imaging for clinical research.

Methods PET images continue to be affected by noise and the partial volume effect (PVE). An approach to reduce simultaneously both effects is to incorporate anatomical information within the PET image reconstruction task. Our extensive simulations of Bayesian PET reconstructions incorporating an anato-functional joint entropy (JE) prior have revealed considerable promise, moving beyond conventional approaches that assume over-simplified correlations between anatomy and radiopharmaceutical uptake. We applied this technique to [11C]DPA-713 PET and MRI imaging studies of healthy control subjects (n=3). DTI imaging was additionally performed on each subject (as the study aims to also investigate changes in white matter tract in controls vs. schizophrenic patients). We hypothesized that utilization of MRI and/or DTI images within PET reconstruction could impact and enhance PET imaging. Eighteen regions-of-interest (ROIs) were considered. Parametric K1 and distribution volume (DV) images were generated using a standard 2-tissue 5-parameter compartmental model and a linear regression with spatial constraint (LRSM) algorithm, and were statistically compared.

Results In comparison to standard 3D-OSEM reconstructed images, MRI- and DTI-guided PET images depicted significant qualitative differences, demonstrating considerably sharper distinction between various regions. Ongoing quantitative analysis has revealed increases in nearly all regions of the parametric images for both DV (by 17%; P<0.02) and K1 (by 27%; P<0.001).

Conclusions Anatomy-guided image reconstruction can substantially impact quality and quantification of PET images, and have the potential to enhance parametric PET imaging significantly

Back to top

In this issue

Journal of Nuclear Medicine
Vol. 53, Issue supplement 1
May 2012
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
MRI- and DTI-guided PET image reconstruction: Application to imaging with [11C]DPA-713
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
MRI- and DTI-guided PET image reconstruction: Application to imaging with [11C]DPA-713
Hyeyun Jung, Jennifer Coughlin, Jing Tang, Christopher Endres, Yun Zhou, Susumu Mori, Dean Wong, Martin Pomper, Arman Rahmim
Journal of Nuclear Medicine May 2012, 53 (supplement 1) 375;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
MRI- and DTI-guided PET image reconstruction: Application to imaging with [11C]DPA-713
Hyeyun Jung, Jennifer Coughlin, Jing Tang, Christopher Endres, Yun Zhou, Susumu Mori, Dean Wong, Martin Pomper, Arman Rahmim
Journal of Nuclear Medicine May 2012, 53 (supplement 1) 375;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis

  • Assessment of AI-Enhanced Quantitative Volumetric MRI with Semi-Quantitative Analysis in 18F-FDG Metabolic Imaging for Alzheimer's Diagnosis.
  • Assessment of SUV consistency in PET/CT with annulus 68Ge DQA phantom
  • Assessment of Tumor Burden in Lymphoma Patients with Deauville Score 4 Disease on Post Therapy FDG PET
Show more Instrumentation & Data Analysis

Image Generation: PET/MRI

  • Possible errors with MR-based attenuation correction for brain imaging in PET/MR scanners
  • A method for estimating the attenuation correction for the MR hardware of an MR/PET scanner
  • Three MRI-based attenuation correction methods for PET
Show more Image Generation: PET/MRI

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire