Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis: Image Generation

CT based motion correction of dual gated cardiac PET images

Riku Klen, Tommi Noponen, Juha Koikkalainen, Jyrki Lötjönen, Kris Thielemans, Erika Hoppela, Hannu Sipilä, Mika Teräs and Juhani Knuuti
Journal of Nuclear Medicine May 2010, 51 (supplement 2) 1367;
Riku Klen
1Turku PET Centre, University of Turku, Turku, Finland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tommi Noponen
2Turku PET Centre, Turku University Hospital, Turku, Finland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Juha Koikkalainen
3Knowledge Intensive Services, VTT Technical Research Centre of Finland, Tampere, Finland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jyrki Lötjönen
3Knowledge Intensive Services, VTT Technical Research Centre of Finland, Tampere, Finland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kris Thielemans
4Hammersmith Imanet Ltd, GE Healthcare, London, United Kingdom
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Erika Hoppela
2Turku PET Centre, Turku University Hospital, Turku, Finland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Hannu Sipilä
2Turku PET Centre, Turku University Hospital, Turku, Finland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mika Teräs
2Turku PET Centre, Turku University Hospital, Turku, Finland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Juhani Knuuti
1Turku PET Centre, University of Turku, Turku, Finland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

1367

Objectives Dual gating is a method to divide the tomographic data into smaller bins according to the respiratory motion and ECG of the patient. It reduces the harmful motion artifacts but at the same time produces several images with a moderate quality. In this study a novel motion correction algorithm is introduced to combine the dual gated PET images into one motion corrected image with a high sensitivity.

Methods The dual-gated PET/CT phantom and patient data were acquired with Discovery VCT PET/CT scanner (GE Healthcare). The phantom data were collected using a realistic heart phantom with simulated respiratory and pulsatile motion including hot targets mimicking coronary plaques. Reconstruction software (Research gating toolbox) provided by GE Healthcare was used to reconstruct all the PET images. Motion correction of the dual gated PET images of the phantom was carried out by using gated low-dose CT images. From the respiratory gated CT data a model was created to correct respiratory motion and from the ECG gated CT data pulsatile motion from PET images. The efficiency of the motion correction methods was tested in three analyses: motion reduction, contrast to noise (CNR) and size of the target.

Results After the motion correction respiratory motion averaged over all hot targets decreased from 12.1 ± 1.5 mm to 6.5 ± 1.5 mm and pulsatile motion from 6.4 ± 0.8 mm to 3.7 ± 1.2 mm. After correcting the respiratory motion the CNR of myocardium uptake increased 50.5% after both corrections. Similar increase of CNR was found in hot spots. The size of hot spots on average decreased 49.7% after the double correction.

Conclusions The method to correct cardiac motion in PET images reduces motion artifacts, increases CNR and decreases the size of hot targets significantly. The feasibility of this method with the patient data will be tested soon.

Research Support The Finnish Funding Agency TEKE

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 51, Issue supplement 2
May 2010
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
CT based motion correction of dual gated cardiac PET images
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
CT based motion correction of dual gated cardiac PET images
Riku Klen, Tommi Noponen, Juha Koikkalainen, Jyrki Lötjönen, Kris Thielemans, Erika Hoppela, Hannu Sipilä, Mika Teräs, Juhani Knuuti
Journal of Nuclear Medicine May 2010, 51 (supplement 2) 1367;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
CT based motion correction of dual gated cardiac PET images
Riku Klen, Tommi Noponen, Juha Koikkalainen, Jyrki Lötjönen, Kris Thielemans, Erika Hoppela, Hannu Sipilä, Mika Teräs, Juhani Knuuti
Journal of Nuclear Medicine May 2010, 51 (supplement 2) 1367;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis: Image Generation

  • Evaluation of a 4D PET image reconstruction method with respiratory motion compensation in a patient study
  • A novel semi-automatic method to quantify human brown adipose tissue (BAT) activity on 18F-FDG PET-CT
  • Investigation of the feasibility of dynamic cardiac imaging with a dual detector gamma camera (DDGC)
Show more Instrumentation & Data Analysis: Image Generation

Image Generation Posters

  • On Enhancing Monte-Carlo Scatter Correction for Y90 Bremsstrahlung SPECT using Guided Filtering
  • Data-driven rigid motion correction of PET brain images using list mode reconstruction
  • Simultaneous Attenuation Correction and Reconstruction of PET Images Using Deep Convolutional Encoder Decoder Networks from Emission Data
Show more Image Generation Posters

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire