Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Meeting ReportInstrumentation & Data Analysis

ZTE-based clinical bone imaging for PET/MR

Gaspar Delso, Florian Wiesinger, Michael Carl, Graeme McKinnon, Mehdi Khalighi, Edwin ter Voert, Felipe Barbosa, Martin Huellner and Patrick Veit-Haibach
Journal of Nuclear Medicine May 2015, 56 (supplement 3) 1806;
Gaspar Delso
1GE Healthcare, Waukesha, WI
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Florian Wiesinger
3GE Global Research, Munich, Germany
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Michael Carl
1GE Healthcare, Waukesha, WI
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Graeme McKinnon
1GE Healthcare, Waukesha, WI
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mehdi Khalighi
1GE Healthcare, Waukesha, WI
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Edwin ter Voert
2University Hospital of Zurich, Zurich, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Felipe Barbosa
2University Hospital of Zurich, Zurich, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Martin Huellner
2University Hospital of Zurich, Zurich, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Patrick Veit-Haibach
2University Hospital of Zurich, Zurich, Switzerland
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Info & Metrics
Loading

Abstract

1806

Objectives One of the main limitations of hybrid PET/MR is the difficulty of imaging cortical bone with MR. Several methods have been published [1-4] to overcome this limitation. Among the most popular is the combination of short-echo-time MR sequences with dedicated post-processing to segment cortical bone. The goal of these methods is generally the creation of attenuation maps for PET reconstruction, rather than clinically usable images. In this study, we evaluate a method based on zero-echo-time (ZTE) acquisitions for the purpose of clinical imaging of the skeletal system.

Methods Twenty examinations of joints were performed on healthy volunteers using a Discovery 750w MR (GE Healthcare). Based on a recently published bone attenuation correction method [5], a customized version of the SilentMR sequence was acquired in each case. The geometry and coil varied with the imaged anatomy, but acquisition times were kept around 3min, with resolution ≈1.2mm3, FA 1deg, BW ±62.5kHz. Data were automatically equalized and rescaled for bone visualization. The resulting images were evaluated by two experienced radiologists.

Results A typical PDw ZTE acquisition is depicted in fig. 1. Clinically, musculoskeletal structures such as cortical bone and tendons are clearly depicted, with thinner epiphysis layers visible in 2D views but requiring some interaction in rendering views. The main limitation of the method is local coil sensitivity variation, due to the PDw acquisition, which confines target bone structures to a narrow intensity range. Adequate intensity equalization is therefore mandatory. This can be successfully implemented for regions delimited by clear air-tissue interfaces, but remains challenging in unbounded acquisitions (e.g. hip or shoulder)

Conclusions Our results prove that clinically usable images of the skeletal system can be obtained with ZTE MR. Future work with tri-modality data will validate these results versus CT. The technique will then be adapted for the identification PET/MR bone lesions.

Previous
Back to top

In this issue

Journal of Nuclear Medicine
Vol. 56, Issue supplement 3
May 1, 2015
  • Table of Contents
  • Index by author
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
ZTE-based clinical bone imaging for PET/MR
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
ZTE-based clinical bone imaging for PET/MR
Gaspar Delso, Florian Wiesinger, Michael Carl, Graeme McKinnon, Mehdi Khalighi, Edwin ter Voert, Felipe Barbosa, Martin Huellner, Patrick Veit-Haibach
Journal of Nuclear Medicine May 2015, 56 (supplement 3) 1806;

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
ZTE-based clinical bone imaging for PET/MR
Gaspar Delso, Florian Wiesinger, Michael Carl, Graeme McKinnon, Mehdi Khalighi, Edwin ter Voert, Felipe Barbosa, Martin Huellner, Patrick Veit-Haibach
Journal of Nuclear Medicine May 2015, 56 (supplement 3) 1806;
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
  • Info & Metrics

Related Articles

  • No related articles found.
  • Google Scholar

Cited By...

  • No citing articles found.
  • Google Scholar

More in this TOC Section

Instrumentation & Data Analysis

  • Exploring the impact of feature selection methods and classification algorithms on the predictive performance of PET radiomic ML models in lung cancer
  • Accuracy of 177Lu-DOTATATE PRRT absorbed dose estimation by reducing the imaging points
  • Assessment of AI-Enhanced Quantitative Volumetric MRI with Semi-Quantitative Analysis in 18F-FDG Metabolic Imaging for Alzheimer's Diagnosis.
Show more Instrumentation & Data Analysis

MTA II: Image Generation Posters

  • Evaluation of a list-mode TOF-MLAA reconstruction with a magnitude preconditioning using GATE
  • Impact of data-driven respiratory gating on pre-therapeutic Tc99-MAA-based SIRT dose estimations
  • PSF Overestimation Improves PET Image SUV Quantification
Show more MTA II: Image Generation Posters

Similar Articles

SNMMI

© 2025 SNMMI

Powered by HighWire