Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleClinical Investigations

Human Radiation Dosimetry for the N-Methyl-d-Aspartate Receptor Radioligand 11C-CNS5161

Vijay Dhawan, William Robeson, David Bjelke, Thomas Chaly, Kristin Graf, Matthew Hellman, Limei Zhuo, Meggan Mackay and David Eidelberg
Journal of Nuclear Medicine June 2015, 56 (6) 869-872; DOI: https://doi.org/10.2967/jnumed.114.152447
Vijay Dhawan
1Center for Neurosciences, Feinstein Institute for Medical Research, Manhasset, New York
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
William Robeson
2Department of Radiology, North Shore–LIJ Health System, Manhasset, New York; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
David Bjelke
1Center for Neurosciences, Feinstein Institute for Medical Research, Manhasset, New York
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Thomas Chaly
1Center for Neurosciences, Feinstein Institute for Medical Research, Manhasset, New York
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Kristin Graf
1Center for Neurosciences, Feinstein Institute for Medical Research, Manhasset, New York
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Matthew Hellman
1Center for Neurosciences, Feinstein Institute for Medical Research, Manhasset, New York
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Limei Zhuo
1Center for Neurosciences, Feinstein Institute for Medical Research, Manhasset, New York
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Meggan Mackay
3Center for Autoimmune and Musculoskeletal Disease, Feinstein Institute for Medical Research, Manhasset, New York
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
David Eidelberg
1Center for Neurosciences, Feinstein Institute for Medical Research, Manhasset, New York
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

11C-CNS5161 (N-(2-chloro-5-methylthiophenyl)-N′-(3-methylthiophenyl)-N′-11C-methylguanidine) has been successfully used in PET imaging of N-methyl-d-aspartate (NMDA) receptors. However, no human dosimetry data have been published. We are planning to use this radiotracer for investigating NMDA receptor function in systemic lupus erythematosus, traumatic brain injury, and Parkinson disease. We have therefore undertaken 11C-CNS5161 PET imaging to measure the whole-body distribution of this radionuclide and to estimate radiation dose to various organs. Methods: Dynamic PET studies of the whole body were performed on 5 healthy adults. Regions of interest were drawn over the visualized structures. Resultant time–activity curves were generated and used to determine residence times for dosimetry calculations. S factors were implemented within the OLINDA/EXM software for each structure or organ. Results: For 11C-CNS5161, organ doses ranged from 0.0002 to 0.0393 mGy/MBq (0.0006–0.1455 rad/mCi). The critical organ for radiation burden was the lungs, with a dose of 0.0393 mGy/MBq (0.1455 rad/mCi). Radiation doses to the reproductive and blood-forming organs were 0.0023, 0.0002, and 0.0020 mGy/MBq (0.0086, 0.0006, and 0.0074 rad/mCi) for the ovaries, testes, and red marrow, respectively. The effective dose equivalent was 0.0106 mSv/MBq (0.0392 rem/mCi). Conclusion: The radiation dosimetry for 11C-CNS5161 for a standard single injection of 555 MBq (15 mCi) will result in an effective dose equivalent of 5.9 mSv (0.59 rem) and a lung dose of 21.8 mGy (2.18 rad) in young, healthy subjects.

  • 11C-CNS5161
  • dosimetry
  • PET

The N-methyl-d-aspartate (NMDA) receptor is a ligand-gated ion channel and mediates the effects of glutamate. Abnormalities of NMDA receptor function have been implicated in physiologic and pathologic processes, especially memory formation and excitotoxicity (1). Previous studies have also implicated NMDA receptor function in stroke, head injury, epilepsy, and Parkinson disease (2). Overexpression and phosphorylation of NMDA receptors have been demonstrated in dyskinesia after levodopa treatment in Parkinson disease (3). We are interested in investigating the role of the NMDA receptor in systemic lupus erythematosus (4), cognitive impairment after traumatic brain injury, and Parkinson disease.

11C-CNS5161 (N-(2-chloro-5-methylthiophenyl)-N′-(3-methylthiophenyl)-N′-11C-methylguanidine) is a selective noncompetitive antagonist of the NMDA glutamate receptor. Its synthesis was reported by Zhao et al. (5), and its use in vivo was reported by Schiffer et al. (6).

Even though a small number of PET studies using 11C-CNS5161 have been published, no whole-body human dosimetry data are available. Similarly, other PET radiotracers are also under development for NMDA receptors, but human dosimetry data have not yet been published (7,8). We therefore undertook a whole-body PET imaging study of this radiotracer to obtain human dosimetry data.

MATERIALS AND METHODS

Five healthy control subjects were recruited (age range, 19–35 y; 3 men and 2 women; Table 1). The study was approved by the Institutional Review Board at North Shore University Hospital. Informed written consent was obtained from each subject after a detailed explanation of the study, which was conducted under Radioactive Drug Research Committee–approved protocols in which the dose limits are organ-based.

View this table:
  • View inline
  • View popup
TABLE 1

Demographics of the Healthy Volunteers

The radiotracer was synthesized using a minor modification of the published method of Zhao et al. (5). Briefly, the commercially available desmethyl guanidine analog 1 was reacted with 11C-methyl iodide in the presence of sodium hydride in acetonitrile (Fig. 1). Purification by semipreparative high-performance liquid chromatography afforded a clean separation of the product from other regioisomers. The product was then diluted in sterile water and purified further using a silica-based C18 Sep-Pak (Waters). Elution with ethanol and sterile saline yielded 11C-CNS5161 with a radiochemical purity of at least 90% and a specific activity of at least 11 GBq/μmol (300 mCi/μmol).

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Radiosynthesis of 11C-CNS5161.

Dynamic PET scans of the whole body were acquired in 2-dimensional mode on an Advance tomograph (GE Healthcare) with a 15-cm axial field of view. Two-dimensional mode imaging was used to avoid scatter from the bladder. For attenuation correction, transmission data using a 68Ge rotating source were acquired before radiotracer injection. Approximately 555 MBq (15 mCi) of 11C-CNS5161 were injected through a venous line in the arm. Dynamic imaging was initiated at the time of injection. The scanning protocol included 1-min emission scans for the first 4 cycles (each cycle is 7 bed positions) and 2 min for the next 4 cycles, covering the skull to mid thigh. The full-body scanning time was therefore 7 or 14 min, resulting in a total duration of 84 min (28 min for the first 4 cycles and 56 min for the next 4 cycles). Images were reconstructed in 2-dimensional mode using a manufacturer-supplied reconstruction technique (ordered-subsets expectation maximization with 16 subsets and 4 iterations).

Coronal images were reconstructed from the transaxial image set and then summed to create a composite image. Volumes of interest were drawn over the entire body and each visualized organ. Counts per voxel were multiplied by organ voxels to obtain total counts in each organ. Data were then normalized to the total body to compute specific organ uptake (this makes the calculations independent of organ mass). Time–activity curves for the organs were fit to a nonlinear regression model of exponential uptake and clearance, and analytic integration was used to estimate the area under the curve (AUC). Units for AUC are hours. A remainder term was computed for activity in the body not specifically visualized in an organ. Residence times were input to the OLINDA/EXM software for each organ based on the adult model to compute the organ doses and effective dose equivalent (9). This software multiplies residence time for each subject and organ by the S value (mSv/MBq × h) as follows:Embedded ImageEq. 1

S values are implemented within the OLINDA/EXM software.

RESULTS

Body images from a representative subject are presented in Figure 2. Each panel is a composite of 7 frames of 2-min duration each. The data were acquired in 2-dimensional mode to avoid scatter effects from the bladder. The figure shows composite images from 3 phases of the study: 0–21 min (early), 21–49 min (mid), and 56–84 min (late) after injection. Rapid uptake of radiotracer in the lungs was followed by a gradual decrease over the study duration; uptake in the liver, gastrointestinal tract, and pancreas increased continuously over 90 min; the bladder showed significant uptake toward the end because of urine accumulation.

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Early (A), mid (B), and late (C) 11C-CNS5161 PET images of 26-y-old healthy woman. Uptake can be seen primarily in lungs in early image. By 30 min, decreasing uptake in lungs and increasing uptake in liver and gastrointestinal tract can be observed. In late image, increased uptake in liver, gastrointestinal tract, pancreas, bladder, and, to a lesser degree, thyroid and brain, is evident.

Typical time–activity curves from the sampled organs are shown in Figure 3. The organs that followed a fast wash-in and washout were the lungs, kidneys, heart, and thyroid. The brain, marrow, pancreas, and liver demonstrated fast wash-in but a slower washout. Bladder activity showed a slow wash-in (gradual accumulation of urine radioactivity) and a slow washout. These curves were fitted using a sum of rising and decaying exponentials. AUCs were calculated and used for estimating the absorbed dose to the organs.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Typical time–activity curves from 9 sampled organs. y-axis scales vary for different organs. These curves were fitted using either sum of 2 exponentials or pulse function (t × e−kt) plus sum of 2 exponentials. AUCs were calculated and used for estimating absorbed dose to organ. Both maximum height and shape of curves determine AUCs, as is reflected in absorbed dose. t = time; e−kt = exponential function with rate constant k.

Table 2 presents the results for 16 organs and the effective dose equivalent for the 5 subjects.

View this table:
  • View inline
  • View popup
TABLE 2

Dosimetry for 11C-CNS5161

DISCUSSION

These dosimetry data show that—in order not to exceed a 50-mGy (5-rad) dose to the critical organ (lungs)—the maximum injected dose in 11C-CNS5161 studies is 1,258 MBq (34 mCi). For two other 11C-labeled radiotracers in common use, raclopride and Pittsburgh compound B, the estimated maximum dose is 1,591 and 1,184 MBq (43 and 32 mCi), respectively (10–12). However, it has been previously demonstrated that even with an injected dose of 555 MBq (15 mCi) for these radiotracers, images of acceptable quality have been acquired and quantitatively analyzed (13,14).

No animal dosimetry data have been published. However, data from biodistribution studies in rats are available (1). We have compared the AUCs derived from time–activity curves of percentage injected dose per organ with our human dose estimates. According to the AUCs, the relative uptake in rats follows this order: liver > lungs > kidneys > spleen > brain > heart. In our human study, the relative uptake followed this order: lungs > spleen > thyroid > kidneys > bladder > brain > liver. Thus, the distribution of this radiotracer in rats and humans is similar, except for the liver. Differences in the species and the study design could account for this observation. Effective dose equivalent and all organ dose levels were within radiation safety guidelines for injections of 555 MBq (15 mCi) (Table 2). For most 11C radiotracers, the bladder does not seem to be a critical organ, unlike the case for various 18F tracers such as 18F-FDOPA (6-18F-fluoro-l-dopa) and 18F-FP-CIT (18F-fluoropropyl-carbomethoxyiodophenylnortropane) (15,16).

To illustrate brain uptake at different times during a dynamic 11C-CNS5161 PET study, in Figure 4 we present a scan of a 34-y-old woman with systemic lupus erythematosus (dedicated 3-dimensional brain imaging not used for dosimetry purposes). These typical brain images demonstrate the high quality of the images that can be acquired with a 555-MBq (15-mCi) bolus injection over a dynamic 90-min scan. The early phase shows a blood-flow–like image with cortical and subcortical uptake as expected. In the mid phase, radiotracer uptake starts to increase in the basal ganglia and thalamus. In the late phase, cortical uptake decreases whereas the thalamus and, to a lesser degree, the lentiform nuclei show significant uptake. This study suggests that multiple scans for different states or conditions can successfully be performed with an injected dose in the 370- to 555-MBq (10–15 mCi) range.

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

Early (A), mid (B), and late (C) 11C-CNS5161 PET brain images of 34-y-old woman with systemic lupus erythematosus. Images were obtained using GE Advance tomograph (GE Healthcare) in 3-dimensional mode. Early blood-flow–like image changes to selective-regional-retention–like image by 90 min.

CONCLUSION

From the 5 subjects studied, the lungs appear to be the critical organ in 11C-CNS5161 dosimetric considerations. The effective dose equivalent was 0.0106 mSv/MBq (0.0392 rad/mCi), which should easily allow for injections of 370–555 MBq (10–15 mCi) for PET studies using this radiotracer.

DISCLOSURE

The costs of publication of this article were defrayed in part by the payment of page charges. Therefore, and solely to indicate this fact, this article is hereby marked “advertisement” in accordance with 18 USC section 1734. This research was supported by the National Institutes of Health (grant 1P01AI073693-05) and the Lupus Foundation of America (grant 113121). David Eidelberg serves on the scientific advisory board and has received honoraria from the Michael J. Fox Foundation for Parkinson’s Research; is listed as coinventor of patents regarding markers for use in screening patients for nervous system dysfunction and a method and apparatus for using the same (without financial gain); and has received research support from the NIH (NINDS, NIDCD, and NIAID) and the Dana Foundation. No other potential conflict of interest relevant to this article was reported.

Acknowledgments

We acknowledge Claude Margouleff for technical assistance with the PET studies and Yoon Young Choi for preparation of the manuscript.

Footnotes

  • Published online Apr. 30, 2015.

  • © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

REFERENCES

  1. 1.↵
    1. Biegon A,
    2. Gibbs A,
    3. Alvarado M,
    4. Ono M,
    5. Taylor S
    . In vitro and in vivo characterization of [3H]CNS-5161—a use-dependent ligand for the N-methyl-D-aspartate receptor in rat brain. Synapse. 2007;61:577–586.
    OpenUrlCrossRefPubMed
  2. 2.↵
    1. Benarroch EE
    . NMDA receptors: recent insights and clinical correlations. Neurology. 2011;76:1750–1757.
    OpenUrlCrossRef
  3. 3.↵
    1. Ahmed I,
    2. Bose SK,
    3. Pavese N,
    4. et al
    . Glutamate NMDA receptor dysregulation in Parkinson’s disease with dyskinesias. Brain. 2011;134:979–986.
    OpenUrlAbstract/FREE Full Text
  4. 4.↵
    1. Kowal C,
    2. Degiorgio LA,
    3. Lee JY,
    4. et al
    . Human lupus autoantibodies against NMDA receptors mediate cognitive impairment. Proc Natl Acad Sci USA. 2006;103:19854–19859.
    OpenUrlAbstract/FREE Full Text
  5. 5.↵
    1. Zhao Y,
    2. Robins E,
    3. Turton D,
    4. Brady F,
    5. Luthra SK,
    6. Årstad E
    . Synthesis and characterization of N-(2-chloro-5-methylthiophenyl)-N′-(3-methylthiophenyl)-N′-[11C]methylguanidine [11C]CNS 5161, a candidate PET tracer for functional imaging of NMDA receptors. J Labelled Comp Radiopharm. 2006;49:163–170.
    OpenUrlCrossRef
  6. 6.↵
    1. Schiffer WK,
    2. Pareto-Onghena D,
    3. Wu H,
    4. et al
    . In vivo evaluation of [11C]CNS-5161 as a use-dependent ligand for the NMDA glutamate receptor channel [abstract]. J Cereb Blood Flow Metab. 2005;25(suppl):S595.
    OpenUrlCrossRef
  7. 7.↵
    1. Kumlien E,
    2. Hartvig P,
    3. Valind S,
    4. Oye I,
    5. Tedroff J,
    6. Langstrom B
    . NMDA-receptor activity visualized with (S)-[N-methyl-11C]ketamine and positron emission tomography in patients with medial temporal lobe epilepsy. Epilepsia. 1999;40:30–37.
    OpenUrlCrossRefPubMed
  8. 8.↵
    1. McGinnity CJ,
    2. Hammers A,
    3. Riano Barros DA,
    4. et al
    . Initial evaluation of 18F-GE-179, a putative PET tracer for activated N-methyl D-aspartate receptors. J Nucl Med. 2014;55:423–430.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    1. Stabin MG,
    2. Sparks RB,
    3. Crowe E
    . OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine. J Nucl Med. 2005;46:1023–1027.
    OpenUrlAbstract/FREE Full Text
  10. 10.↵
    1. Scheinin NM,
    2. Tolvanen TK,
    3. Wilson IA,
    4. Arponen EM,
    5. Nagren KA,
    6. Rinne JO
    . Biodistribution and radiation dosimetry of the amyloid imaging agent 11C-PIB in humans. J Nucl Med. 2007;48:128–133.
    OpenUrlAbstract/FREE Full Text
  11. 11.
    1. Slifstein M,
    2. Hwang DR,
    3. Martinez D,
    4. et al
    . Biodistribution and radiation dosimetry of the dopamine D2 ligand 11C-raclopride determined from human whole-body PET. J Nucl Med. 2006;47:313–319.
    OpenUrlAbstract/FREE Full Text
  12. 12.↵
    1. van der Aart J,
    2. Hallett WA,
    3. Rabiner EA,
    4. Passchier J,
    5. Comley RA
    . Radiation dose estimates for carbon-11-labelled PET tracers. Nucl Med Biol. 2012;39:305–314.
    OpenUrlCrossRefPubMed
  13. 13.↵
    1. Brooks DJ,
    2. Ibanez V,
    3. Sawle GV,
    4. et al
    . Striatal D2 receptor status in patients with Parkinson’s disease, striatonigral degeneration, and progressive supranuclear palsy, measured with 11C-raclopride and positron emission tomography. Ann Neurol. 1992;31:184–192.
    OpenUrlCrossRefPubMed
  14. 14.↵
    1. Klunk WE,
    2. Engler H,
    3. Nordberg A,
    4. et al
    . Imaging brain amyloid in Alzheimer’s disease with Pittsburgh compound-B. Ann Neurol. 2004;55:306–319.
    OpenUrlCrossRefPubMed
  15. 15.↵
    1. Dhawan V,
    2. Belakhlef A,
    3. Robeson W,
    4. et al
    . Bladder wall radiation dose in humans from fluorine-18-FDOPA. J Nucl Med. 1996;37:1850–1852.
    OpenUrlAbstract/FREE Full Text
  16. 16.↵
    1. Robeson W,
    2. Dhawan V,
    3. Belakhlef A,
    4. et al
    . Dosimetry of the dopamine transporter radioligand 18F-FPCIT in human subjects. J Nucl Med. 2003;44:961–966.
    OpenUrlAbstract/FREE Full Text
  • Received for publication November 28, 2014.
  • Accepted for publication April 13, 2015.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 56 (6)
Journal of Nuclear Medicine
Vol. 56, Issue 6
June 1, 2015
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Human Radiation Dosimetry for the N-Methyl-d-Aspartate Receptor Radioligand 11C-CNS5161
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Human Radiation Dosimetry for the N-Methyl-d-Aspartate Receptor Radioligand 11C-CNS5161
Vijay Dhawan, William Robeson, David Bjelke, Thomas Chaly, Kristin Graf, Matthew Hellman, Limei Zhuo, Meggan Mackay, David Eidelberg
Journal of Nuclear Medicine Jun 2015, 56 (6) 869-872; DOI: 10.2967/jnumed.114.152447

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Human Radiation Dosimetry for the N-Methyl-d-Aspartate Receptor Radioligand 11C-CNS5161
Vijay Dhawan, William Robeson, David Bjelke, Thomas Chaly, Kristin Graf, Matthew Hellman, Limei Zhuo, Meggan Mackay, David Eidelberg
Journal of Nuclear Medicine Jun 2015, 56 (6) 869-872; DOI: 10.2967/jnumed.114.152447
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • Human Dosimetry of the N-Methyl-D-Aspartate Receptor Ligand 11C-GMOM
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles

Keywords

  • 11C-CNS5161
  • dosimetry
  • PET
SNMMI

© 2025 SNMMI

Powered by HighWire