Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleClinical Investigations

Use of a Single 11C-Meta-Hydroxyephedrine Scan for Assessing Flow–Innervation Mismatches in Patients with Ischemic Cardiomyopathy

Hendrik J. Harms, Mark Lubberink, Stefan de Haan, Paul Knaapen, Marc C. Huisman, Robert C. Schuit, Albert D. Windhorst, Cornelis P. Allaart and Adriaan A. Lammertsma
Journal of Nuclear Medicine November 2015, 56 (11) 1706-1711; DOI: https://doi.org/10.2967/jnumed.115.154377
Hendrik J. Harms
1Department of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, Netherlands
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Mark Lubberink
2Department of Nuclear Medicine and PET Research, Uppsala University, Uppsala, Sweden; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Stefan de Haan
3Department of Cardiology, VU University Medical Center, Amsterdam, Netherlands
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Paul Knaapen
3Department of Cardiology, VU University Medical Center, Amsterdam, Netherlands
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Marc C. Huisman
1Department of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, Netherlands
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Robert C. Schuit
1Department of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, Netherlands
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Albert D. Windhorst
1Department of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, Netherlands
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Cornelis P. Allaart
3Department of Cardiology, VU University Medical Center, Amsterdam, Netherlands
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Adriaan A. Lammertsma
1Department of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, Netherlands
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Abstract

Mismatch between areas of reduced myocardial blood flow (MBF) and reduced myocardial innervation (defect areas) may be used to estimate the risk for ventricular arrhythmias. The presence of a mismatch zone can be derived using a combined protocol consisting of both an MBF scan and an 11C-meta-hydroxyephedrine (11C-HED) scan. The rate of influx from blood to myocardium (K1) of 11C-HED is proportional to MBF and can potentially be used as an index for defining MBF defects. The aim of this study was to assess whether K1 derived from an 11C-HED scan can be used as an index of MBF, potentially allowing for an assessment of MBF–innervation mismatch areas from a single 11C-HED scan. Methods: Seventeen patients with known ischemic cardiomyopathy underwent dynamic 15O-water and 11C-HED scans. Discrete arterial blood samples were taken during 11C-HED scans for metabolite correction of the image-derived input function. 11C-HED influx rate was obtained using a single-tissue-compartment model and compared with transmural MBF (MBFT), defined as MBF as measured with 15O-water multiplied by perfusable tissue fraction. Defect sizes were obtained from parametric K1 and MBFT images, using 50% of a remote control segment as the cutoff value. Results: There was a significant correlation between MBFT and K1 (y = 0.40x + 0.05 mL·g−1·min−1, r = 0.80, P < 0.001), although K1 was significantly lower than MBFT (slope of the regression line significantly different from 1, P < 0.001). Correlation between MBFT and K1 defect sizes was high (y = 0.89x + 1.38%, r = 0.95, P < 0.001), with no significant difference in mean defect size based on K1 or MBFT (20.9% ± 11.3% and 20.1% ± 10.7% for MBFT and K1, respectively, P = 0.41). Conclusion: 11C-HED influx rate K1 can be used as an alternative to a separate MBF scan for assessing mismatch areas between MBF and myocardial innervation.

  • innervation–blood flow mismatch
  • sympathetic denervation
  • 11C-HED
  • arrhythmias

There has been long-standing interest in noninvasive imaging of myocardial sympathetic innervation for the prediction of life-threatening ventricular arrhythmias or implantable cardioverter defibrillator discharges using PET (1–5) or SPECT (6–8). It has been shown (9–11) that, in myocardial infarction, the area of reduced innervation often exceeds the area of reduced myocardial blood flow (MBF) (9–14). Furthermore, in a porcine model of myocardial infarction, it has been shown that the occurrence of such MBF–innervation mismatch zones is related to inducible ventricular tachycardias originating from these zones (15). The potential of MBF–innervation mismatch zones in risk assessment has been demonstrated in the recent PAREPET study (16), in which patients developing sudden cardiac arrest had a significantly larger area of viable but denervated myocardium. Therefore, noninvasive imaging for identifying MBF–innervation mismatch zones may play a role in risk stratification of patients with ischemic cardiomyopathy who are considered for cardioverter defibrillator implantation.

MBF–innervation mismatch zones are generally quantified using separate MBF and innervation scans. The use of separate scans, however, has some disadvantages: motion artifacts between scans may occur, overall study duration is prolonged, and radiation dose to the patient is increased. Clearly, a single-scan protocol for defining MBF–innervation mismatches would be preferable.

Recently, it has been shown that the kinetics of 11C-meta-hydroxyephedrine (11C-HED) can be described reliably using a single-tissue-compartment model with corrections for left and right ventricular spill-over (17). The underlying tracer kinetic model has two parameters: K1 and k2, which represent the rate of 11C-HED transfer from blood to myocardium (influx rate) and the rate of transfer from myocardium to blood (clearance rate), respectively. The volume of distribution of 11C-HED, defined as the ratio of K1 to k2, represents net uptake, that is, equilibrium distribution between tissue and plasma, and can be used as a measure of innervation.

K1 is dependent on both the extraction fraction of 11C-HED and MBF. Therefore, if the extraction fraction of 11C-HED is constant across a clinically relevant range of resting MBF levels, changes in 11C-HED K1 would reflect changes in MBF. In this case a single 11C-HED scan could be used to define MBF–innervation mismatch areas.

Therefore, the aim of this study was to assess whether K1 derived from an 11C-HED scan can be used as an index of MBF.

MATERIALS AND METHODS

Patient Population

Seventeen patients (mean age, 67 y; range, 43–80 y; 13 men) with ischemic cardiomyopathy and a left ventricular ejection fraction below 35% based on cardiac MR imaging were included. Ischemic cardiomyopathy was defined as the presence of one or more stenoses of greater than 50% as determined from a coronary angiogram and delayed contrast enhancement on cardiac MR imaging. The study was approved by the Medical Ethics Review Committee of the VU University Medical Center, and all participants gave written informed consent before inclusion.

Scanning Protocol

The patients underwent a dynamic 15O-water scan, followed by an 11C-HED scan in the same session. All studies were performed on a Gemini TF-64 (Philips Healthcare) PET/CT scanner (18).

A 5-mL bolus injection of 370 MBq of 15O-water (0.8 mL·s−1), followed by 35 mL of saline (2 mL·s−1), was administered simultaneously with the start of a list-mode emission scan of 6 min. The injected dose was chosen to remain within the linear range of the scanner, the upper limit of which is at a singles counting rate of about 35 Mcps (19). Maximum singles counting rates in the present study were approximately 32 Mcps during the first pass of the bolus. This PET scan was followed immediately by a respiration-averaged low-dose CT scan (55 mAs; rotation time, 1.5 s; pitch, 0.825; collimation, 64 × 0.625; acquiring 20 cm in 11 s) during normal breathing. The emission scan was reconstructed into 22 frames (1 × 10, 8 × 5, 4 × 10, 2 × 15, 3 × 20, 2 × 30, and 2 × 60 s) using the 3-dimensional row action maximum-likelihood algorithm and applying all appropriate corrections for scanner normalization, dead time, decay, randoms, scatter, and attenuation, with the attenuation correction being based on the corresponding low-dose CT scan. Frames consisted of 45 planes of 144 × 144 voxels with voxels having dimensions of 4 × 4 × 4 mm. The effective radiation dose for a 15O-water study and low-dose CT was estimated as 1.5 mSv.

11C-HED was synthesized as described previously (17). At least 10 min after the end of the 15O-water scan, 370 MBq of 11C-HED were injected as a 5-mL bolus (0.8 mL·s−1) followed by a 35-mL saline flush (2 mL·s−1), simultaneously starting a 60-min list-mode emission scan. After the emission scan, a slow low-dose CT scan was performed to correct for attenuation, similar to the 15O-water scan. Images were reconstructed into 36 frames (1 × 10, 8 × 5, 4 × 10, 3 × 20, 5 × 30, 5 × 60, 4 × 150, 4 × 300, and 2 × 600 s) using the 3-dimensional row action maximum-likelihood algorithm and applying all appropriate corrections. The effective radiation dose for a 11C-HED study and low-dose CT was estimated as 2.5 mSv.

Blood Sampling

Before the scanning session, all patients received an indwelling radial artery cannula for withdrawal of discrete blood samples during the dynamic 11C-HED scan. A total of 7 arterial samples of 7 mL each were collected at 2.5, 5, 10, 20, 30, 40, and 60 min after 11C-HED injection. Blood samples were analyzed for blood and plasma activity concentrations and for radiolabeled plasma metabolites of 11C-HED as previously described (17).

Input Functions

Input functions were obtained using in-house–developed software, Cardiac VUer (20,21). For both 15O-water and 11C-HED, 1-cm-diameter regions of interest were placed over the ascending aorta in at least 5 transaxial image planes in the frame showing the first pass of the injected bolus. These regions of interest were combined into one volume of interest for the ascending aorta. A second set of regions of interest was placed over the right ventricular cavity in 5 transaxial planes, with the region-of-interest boundaries at least 1 cm from the right ventricular wall to avoid spill-over of myocardial activity. Again, these regions of interest were combined into one right ventricular volume of interest. Both volumes of interest were then transferred to the full dynamic images to obtain arterial whole-blood and right ventricular time–activity curves.

Next, for 11C-HED only, plasma–to–whole-blood ratios derived from the manual blood samples were fitted to a sigmoid function. Parent fractions derived from these manual samples were fitted to a sigmoid function. Finally, the parent plasma curve was obtained by multiplying the arterial whole-blood curve by the fitted plasma–to–whole-blood ratio and parent fraction curves.

Segmental Analysis

Sixteen myocardial segments, excluding the most distal apical segment, were drawn manually on short-axis images according to the 17-segment model of the American Heart Association (22), using software developed in-house within Matlab 7 (The MathWorks). For 11C-HED, segments were defined on the final frame of the dynamic images, whereas for 15O-water, parametric images of perfusable tissue fraction (PTF) were used. The obtained segment templates were projected onto all frames of their corresponding short-axis dynamic emission scans to extract segmental time–activity curves. These were fitted to a single-tissue-compartment model for both 15O-water and 11C-HED using standard nonlinear least-squares regression according to Equations 1 and 2 for 15O-water (23) and 11C-HED (17), respectively:Embedded ImageEq. 1Embedded ImageEq. 2in which CPET(t), CA(t), CRV(t), and CP(t) represent radioactivity concentrations in tissue, whole blood, right ventricular blood, and parent tracer in plasma, respectively. VA represents left ventricular spill-over and VRV right ventricular spill-over. For 15O-water, total distribution volume VT was fixed to 0.91 mL·g−1 (24), whereas for 11C-HED, VT was calculated as K1/k2.

K1 represents the average 11C-HED influx rate in both perfusable and nonperfusable tissue. However, MBF as measured with 15O-water represents MBF in perfusable tissue alone (25), and the fraction of perfusable tissue is reflected in PTF. To make an appropriate comparison between 11C-HED K1 and MBF as measured with water, MBF was multiplied by PTF to obtain MBF in perfusable and nonperfusable tissue, or transmural MBF (MBFT).

Parametric Images

For 15O-water, parametric images were generated using a basis function implementation (20,26,27) of the single-tissue-compartment model (Eq. 1) with corrections for blood volume, spill-over (23), and PTF (28). One hundred basis functions were used with exponentially spaced values of MBF/VT between 0.1 and 2.5 min−1. For 11C-HED, a basis function implementation of Equation 2 was used, applying 100 basis functions with exponentially spaced values of k2 between 0.002 and 0.1 min−1 and corrections for left and right ventricular spill-over. For 11C-HED, parametric images of VT were obtained by dividing parametric images of K1 by parametric images of k2.

For both 11C-HED and 15O-water, parametric images of anatomic tissue fraction were generated according to Equation 3:Embedded ImageEq. 3in which CTnorm represents the normalized low-dose CT scan and 1.06 represents the density of blood. In voxels with VA+VRV > 0.75, VA or VRV > 0.60, or anatomic tissue fraction < 0.25, MBF, K1, and VT were set to zero to avoid spurious noise–induced high values outside the heart or in blood vessels as described previously (20,29). Finally, MBFT images were obtained by multiplying MBF images by PTF images.

Data Analysis

Correlation between MBFT and K1 was assessed using linear regression. For each patient, 4 adjacent segments were selected and used as a control region. These segments did not border infarct segments and showed normal innervation (VT). If scar and denervation sizes were too large to identify 4 such segments, at least 2 adjacent segments were used instead. For both MBFT and K1, defect size was defined as the percentage of pixels below a percentage (between 20% and 80%, in increments of 5%) of the average of the control region. Similarly, parametric VT images were obtained and used to define innervation defects using the same control region. MBF–innervation mismatch sizes were obtained by subtracting the K1 or MBFT defect size from the VT defect size. To avoid differences in volume-of-interest definition between 11C-HED and 15O-water scans, defect sizes were assessed for the entire left ventricle rather than for each segment individually. Correlation and agreement between defect sizes were assessed using linear regression, Bland–Altman analysis, and paired t tests using Matlab 7. Finally, the Dice similarity coefficient (DSC) was calculated for the polar maps to quantify agreement in both defect location and size.

RESULTS

The scans of 2 patients had visually identifiable motion and were excluded from further analysis. For the remaining 15 patients, the correlation between absolute MBFT and K1 is presented in Figure 1. There was a significant correlation between MBFT and K1 (y = 0.40x + 0.05 mL·g−1·min−1, r = 0.80, P < 0.001), indicating that the extraction fraction of 11C-HED is relatively constant across the range of MBFT values encountered. The slope of the regression line was significantly lower than 1 (P = 0.02), and the intercept was significantly different from 0 (P < 0.001).

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Correlation between K1 of 11C-HED and absolute MBFT on heart segment level. This correlation was significant (r = 0.80, P < 0.001). Slope of regression line was 0.40, which was significantly lower than 1 (P < 0.001). Intercept was 0.05, which was significantly different from 0 (P < 0.001).

For all relative cutoff values, Table 1 shows the correlations, slopes and intercepts of the regression lines, P values of paired t tests, and average DSC. For cutoffs between 30% and 70%, an excellent correlation (r ≥ 0.90) was found and slopes of the regression lines were not significantly different from unity, except for the 35% cutoff value. DSC was above 0.80 for all except an 80% cutoff.

View this table:
  • View inline
  • View popup
TABLE 1

Comparison of Defect Sizes Based on 11C-HED Influx Rate K1 and MBFT as Measured with 15O-Water

Typical examples of parametric MBFT and K1 images are presented in Figure 2, showing reduced MBFT and K1 in the territory of the left anterior descending artery. Corresponding polar plots are shown in Figure 3. The correlation between defect sizes was high (y = 0.89x + 1.38%, r = 0.95, P < 0.001), as shown in Figure 4 using a 50% cutoff. The slope of the regression line was not significantly different from 1 (P = 0.24), and the intercept of the regression line was not significantly different from 0 (P = 0.50). A paired t test showed that defect sizes based on K1 were not significantly different from those based on MBFT (P = 0.41). In addition, when the regression line was forced through the origin, the slope was 0.95, which was not significantly different from 1 (P = 0.20). DSC (0.88 ± 0.05; range, 0.77–0.96) showed good agreement between MBFT and K1 at the polar map level, indicating that defect locations were similar. Figure 5 shows the correlation between mismatch sizes derived using MBFT and K1. A high correlation between mismatch sizes was found (y = 0.89x + 2.2%, r = 0.92, P < 0.001), with slope and intercept not being significantly different from 1 (P = 0.32) and 0 (P = 0.21), respectively. In addition, paired t testing showed that mismatch sizes were not significantly smaller for K1 than for MBFT (20.9% ± 11.3% and 20.1% ± 10.7% for MBFT and K1, respectively, P = 0.41).

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

Typical example of parametric images of MBFT (top) and K1 (bottom) of patient with myocardial infarct in anterior, septal, and apical walls.

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

Polar maps of MBFT and K1 of same patient as in Figure 2. Total defect size, indicated by black areas in B and D, was 28.7% based on MBFT and 27.0% based on K1. DSC was 0.87.

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

Correlation (left) and Bland–Altman (right) plots of defect size based on MBFT and K1. Slope of regression line was 0.89, which was not significantly different from 1 (P = 0.24). Intercept was 1.38, which was not significantly different from 0 (P = 0.50). No significant correlation was found on Bland–Altman analysis (P = 0.21). LV = left ventricle.

FIGURE 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 5.

Correlation (left) and Bland–Altman plot (right) of mismatch size based on MBFT and K1. Slope of regression line was 0.89, which was not significantly different from 1 (P = 0.32). Intercept of regression line was 2.20, which was not significantly different from 0 (P = 0.21). No significant correlation was found on Bland–Altman analysis (P = 0.29). LV = left ventricle; MM = mismatch.

DISCUSSION

In the present proof-of-concept study, a method to assess MBF–innervation mismatch size from a single 11C-HED scan was studied, using the influx rate K1 of 11C-HED to obtain an index of MBF rather than measuring MBF separately using an additional 15O-water scan. Shortening the scanning protocol reduces the risk of motion and total radiation burden. In addition, patient throughput is increased while the method still provides accurate data on mismatch areas.

Direct comparison between K1 and MBFT showed that K1 significantly underestimated MBFT, suggesting that the extraction of 11C-HED is about 40%–50%. However, relative cutoff values compared with remote control segments (15,16) were used to define defect areas, and a consistent underestimation of K1 as compared with MBFT was expected to play a limited role in definition of defect areas. This was indeed confirmed in our study as illustrated by the excellent correlation between defect sizes obtained with K1 and MBFT. In addition, the slope of the regression line was not significantly different from 1, Bland–Altman analysis showed no significant differences between the two defect sizes, and paired t tests showed no significant differences, indicating the potential of using K1 instead of MBFT for mismatch assessment. However, the limited extraction of 11C-HED rules out use of 11C-HED as a tracer of absolute MBF.

This study focused on the use of 50% of a healthy reference region as a cutoff value for both MBFT and K1. Because the optimal method for defining patient-specific cutoff values is as yet unknown, a value of 50% may not be optimal. Therefore, this study included relative cutoff values between 20% and 80% of the value of a healthy reference region (Table 1). For 20%–25% and for 75%–80%, correlation was reduced to an r value of below 0.90, and for cutoffs of 20%–25% and 35%, the slopes of the regression lines started to deviate significantly from unity. However, for the range of 30%–60%, both correlation coefficients and slopes were comparable with the results obtained when a 50% cutoff value was used. In addition, paired t tests showed no significant difference for any of the assessed cutoff values. This indicates that defect areas for K1 and MBFT are similar for a wide range of relative cutoff values for differentiating between healthy and defect tissue. In addition, for different cutoff values, average DSC for all patients was slightly lower at increased cutoffs. However, average DSC was above 0.80 for all cutoff values studied, except for 80%. The optimal cutoff value or a method to define defect areas for both blood flow and innervation has to be defined in larger clinical studies with long-term follow-up. This method might also be different when using relative uptake images (15,16) or fully quantitative parameters, and more clinical studies are warranted.

In this study, 11C-HED K1 was compared with the product of MBF and PTF because MBF derived from a 15O-water scan represents MBF in perfusable tissue whereas 11C-HED K1 represents the transmural rate of influx, that is, in both perfusable and nonperfusable tissue within a region. Assuming no influx of 11C-HED in nonperfusable tissue, uptake signal is reduced in direct proportion to the fraction of nonperfusable tissue. However, MBF derived from 15O-water is calculated using washout rates, and since nonperfusable tissue has no uptake of 15O-water, it does not contribute to the observed washout rate of 15O-water. This results in differences between MBF and 11C-HED influx rate K1 in regions with both perfusable and nonperfusable tissue. Since the fraction of perfusable tissue is routinely calculated as PTF, the product of MBF and PTF should resemble total (transmural) MBF in these regions. It is therefore appropriate to compare 11C-HED K1 with MBFT.

The results of this study are in contrast to those of Rimoldi et al. (30), in which no correlation between MBF and 11C-HED K1 was found in dogs. There are, however, two major differences between the studies. First, in the present study, 11C-HED K1 was compared with the product of MBF and PTF, that is, transmural MBF, whereas Rimoldi et al. used regular MBF as obtained with 15O-water. Comparing MBF with K1 may be inappropriate and yield inaccurate results. To illustrate this, in the present study the correlation between regular nontransmural MBF and 11C-HED K1 was significantly lower, although still significant, with an r value of 0.67. Second, the range of MBF values in the present study was much larger than that of Rimoldi et al., as only patients with ischemic cardiomyopathy, and hence myocardial infarctions and large heterogeneities in MBF, were included. The dogs used by Rimoldi et al. showed regions of denervation but no infarctions, and therefore the range of MBF values was relatively small.

This study had several limitations. First, the number of subjects was relatively small (n = 17) and larger studies might be required before definitive omission of separate MBF scans can be advocated. In addition, the scans of 2 patients (12%) had to be excluded because of visually identifiable motion, and more subtle motion in the remaining patients cannot be excluded. Finally, a large-scale clinical validation is required before any conclusions regarding the application of mismatch zones from 11C-HED alone can be drawn.

CONCLUSION

The rate of influx (K1) of 11C-HED can be used as a potential alternative to a separate MBF scan when assessing mismatch size between MBF and innervation in patients with ischemic cardiomyopathy. This alternative reduces scan duration, radiation dose, and risk of patient motion between scans, but the clinical utility of this mismatch size requires further clinical validation in larger patient cohorts before the method can be used.

DISCLOSURE

The costs of publication of this article were defrayed in part by the payment of page charges. Therefore, and solely to indicate this fact, this article is hereby marked “advertisement” in accordance with 18 USC section 1734. This work was supported financially by Philips Healthcare. No other potential conflict of interest relevant to this article was reported.

Acknowledgments

We thank Amina Elouahmani, Femke Jongsma, Judith van Es, Nazerah Sais, Nghi Pham, Robin Hemminga, and Suzette van Balen for scanning of the patients; Henri Greuter, Kevin Takkenkamp, and Marissa Rongen for production of 15O-water and blood analysis; and Martien Mooijer, Jonas Eriksson, Anneloes Rijnders, Rolf van Kooij, and Johan van den Hoek for synthesis of 11C-HED.

Footnotes

  • Published online Jul. 30, 2015.

  • © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

REFERENCES

  1. 1.↵
    1. Chakraborty PK,
    2. Gildersleeve DL,
    3. Jewett DM,
    4. et al
    . High yield synthesis of high specific activity R-(−)-[11C]epinephrine for routine PET studies in humans. Nucl Med Biol. 1993;20:939–944.
    OpenUrlCrossRefPubMed
  2. 2.
    1. Goldstein DS,
    2. Chang PC,
    3. Eisenhofer G,
    4. et al
    . Positron emission tomographic imaging of cardiac sympathetic innervation and function. Circulation. 1990;81:1606–1621.
    OpenUrlAbstract/FREE Full Text
  3. 3.
    1. Münch G,
    2. Nguyen NT,
    3. Nekolla S,
    4. et al
    . Evaluation of sympathetic nerve terminals with [11C]epinephrine and [11C]hydroxyephedrine and positron emission tomography. Circulation. 2000;101:516–523.
    OpenUrlAbstract/FREE Full Text
  4. 4.
    1. Rosenspire KC,
    2. Haka MS,
    3. Van Dort ME,
    4. et al
    . Synthesis and preliminary evaluation of carbon-11-meta-hydroxyephedrine: a false transmitter agent for heart neuronal imaging. J Nucl Med. 1990;31:1328–1334.
    OpenUrlAbstract/FREE Full Text
  5. 5.↵
    1. Schwaiger M,
    2. Kalff V,
    3. Rosenspire K,
    4. et al
    . Noninvasive evaluation of sympathetic nervous system in human heart by positron emission tomography. Circulation. 1990;82:457–464.
    OpenUrlAbstract/FREE Full Text
  6. 6.↵
    1. Dae MW,
    2. O’Connell JW,
    3. Botvinick EH,
    4. et al
    . Scintigraphic assessment of regional cardiac adrenergic innervation. Circulation. 1989;79:634–644.
    OpenUrlAbstract/FREE Full Text
  7. 7.
    1. Kline RC,
    2. Swanson DP,
    3. Wieland DM,
    4. et al
    . Myocardial imaging in man with I-123 meta-iodobenzylguanidine. J Nucl Med. 1981;22:129–132.
    OpenUrlAbstract/FREE Full Text
  8. 8.↵
    1. Wieland DM,
    2. Wu J,
    3. Brown LE,
    4. Mangner TJ,
    5. Swanson DP,
    6. Beierwaltes WH
    . Radiolabeled adrenergic neuron-blocking agents: adrenomedullary imaging with [131I]iodobenzylguanidine. J Nucl Med. 1980;21:349–353.
    OpenUrlAbstract/FREE Full Text
  9. 9.↵
    1. Jacobson AF,
    2. Senior R,
    3. Cerqueira MD,
    4. et al
    . Myocardial iodine-123 meta-iodobenzylguanidine imaging and cardiac events in heart failure: results of the prospective ADMIRE-HF (AdreView Myocardial Imaging for Risk Evaluation in Heart Failure) study. J Am Coll Cardiol. 2010;55:2212–2221.
    OpenUrlCrossRefPubMed
  10. 10.
    1. Paul M,
    2. Schafers M,
    3. Kies P,
    4. et al
    . Impact of sympathetic innervation on recurrent life-threatening arrhythmias in the follow-up of patients with idiopathic ventricular fibrillation. Eur J Nucl Med Mol Imaging. 2006;33:866–870.
    OpenUrlCrossRefPubMed
  11. 11.↵
    1. Yukinaka M,
    2. Nomura M,
    3. Ito S,
    4. Nakaya Y
    . Mismatch between myocardial accumulation of 123I-MIBG and 99mTc-MIBI and late ventricular potentials in patients after myocardial infarction: association with the development of ventricular arrhythmias. Am Heart J. 1998;136:859–867.
    OpenUrlCrossRefPubMed
  12. 12.
    1. Boogers MJ,
    2. Borleffs CJ,
    3. Henneman MM,
    4. et al
    . Cardiac sympathetic denervation assessed with 123-iodine metaiodobenzylguanidine imaging predicts ventricular arrhythmias in implantable cardioverter-defibrillator patients. J Am Coll Cardiol. 2010;55:2769–2777.
    OpenUrlCrossRefPubMed
  13. 13.
    1. Inoue H,
    2. Zipes DP
    . Results of sympathetic denervation in the canine heart: supersensitivity that may be arrhythmogenic. Circulation. 1987;75:877–887.
    OpenUrlAbstract/FREE Full Text
  14. 14.↵
    1. Kammerling JJ,
    2. Green FJ,
    3. Watanabe AM,
    4. et al
    . Denervation supersensitivity of refractoriness in noninfarcted areas apical to transmural myocardial infarction. Circulation. 1987;76:383–393.
    OpenUrlAbstract/FREE Full Text
  15. 15.↵
    1. Sasano T,
    2. Abraham MR,
    3. Chang KC,
    4. et al
    . Abnormal sympathetic innervation of viable myocardium and the substrate of ventricular tachycardia after myocardial infarction. J Am Coll Cardiol. 2008;51:2266–2275.
    OpenUrlCrossRefPubMed
  16. 16.↵
    1. Fallavollita JA,
    2. Heavey BM,
    3. Luisi AJ Jr.,
    4. et al
    . Regional myocardial sympathetic denervation predicts the risk of sudden cardiac arrest in ischemic cardiomyopathy. J Am Coll Cardiol. 2014;63:141–149.
    OpenUrlCrossRefPubMed
  17. 17.↵
    1. Harms HJ,
    2. de Haan S,
    3. Knaapen P,
    4. et al
    . Quantification of [11C]-meta-hydroxyephedrine uptake in human myocardium. EJNMMI Res. 2014;4:52.
    OpenUrlCrossRefPubMed
  18. 18.↵
    1. Surti S,
    2. Kuhn A,
    3. Werner ME,
    4. Perkins AE,
    5. Kolthammer J,
    6. Karp JS
    . Performance of Philips Gemini TF PET/CT scanner with special consideration for its time-of-flight imaging capabilities. J Nucl Med. 2007;48:471–480.
    OpenUrlAbstract/FREE Full Text
  19. 19.↵
    1. Lubberink M,
    2. van der Veldt A,
    3. Knaapen P,
    4. et al
    . Measurement of tumor and myocardial perfusion using 15O-water and a clinical PET-CT scanner [abstract]. J Nucl Med. 2009;50(suppl 2):238.
    OpenUrl
  20. 20.↵
    1. Harms HJ,
    2. Knaapen P,
    3. de Haan S,
    4. Halbmeijer R,
    5. Lammertsma AA,
    6. Lubberink M
    . Automatic generation of absolute myocardial blood flow images using [15O]H2O and a clinical PET/CT scanner. Eur J Nucl Med Mol Imaging. 2011;38:930–939.
    OpenUrlCrossRefPubMed
  21. 21.↵
    1. Harms HJ,
    2. Nesterov SV,
    3. Han C,
    4. et al
    . Comparison of clinical non-commercial tools for automated quantification of myocardial blood flow using oxygen-15-labelled water PET/CT. Eur Heart J Cardiovasc Imaging. 2014;15:431–441.
    OpenUrlAbstract/FREE Full Text
  22. 22.↵
    1. Cerqueira MD,
    2. Weissman NJ,
    3. Dilsizian V,
    4. et al
    . Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation. 2002;105:539–542.
    OpenUrlFREE Full Text
  23. 23.↵
    1. Hermansen F,
    2. Rosen SD,
    3. Fath-Ordoubadi F,
    4. et al
    . Measurement of myocardial blood flow with oxygen-15 labelled water: comparison of different administration protocols. Eur J Nucl Med. 1998;25:751–759.
    OpenUrlCrossRefPubMed
  24. 24.↵
    1. Bergmann SR,
    2. Herrero P,
    3. Markham J,
    4. Weinheimer CJ,
    5. Walsh MN
    . Noninvasive quantitation of myocardial blood flow in human subjects with oxygen-15-labeled water and positron emission tomography. J Am Coll Cardiol. 1989;14:639–652.
    OpenUrlCrossRefPubMed
  25. 25.↵
    1. Yamamoto Y,
    2. De Silva R,
    3. Rhodes CG,
    4. et al
    . A new strategy for the assessment of viable myocardium and regional myocardial blood flow using 15O-water and dynamic positron emission tomography. Circulation. 1992;86:167–178.
    OpenUrlAbstract/FREE Full Text
  26. 26.↵
    1. Watabe H,
    2. Jino H,
    3. Kawachi N,
    4. et al
    . Parametric imaging of myocardial blood flow with 15O-water and PET using the basis function method. J Nucl Med. 2005;46:1219–1224.
    OpenUrlAbstract/FREE Full Text
  27. 27.↵
    1. Boellaard R,
    2. Knaapen P,
    3. Rijbroek A,
    4. Luurtsema GJ,
    5. Lammertsma AA
    . Evaluation of basis function and linear least squares methods for generating parametric blood flow images using 15O-water and positron emission tomography. Mol Imaging Biol. 2005;7:273–285.
    OpenUrlCrossRefPubMed
  28. 28.↵
    1. Iida H,
    2. Rhodes CG,
    3. De Silva R,
    4. et al
    . Myocardial tissue fraction–correction for partial volume effects and measure of tissue viability. J Nucl Med. 1991;32:2169–2175.
    OpenUrlAbstract/FREE Full Text
  29. 29.↵
    1. Harms HJ,
    2. de Haan S,
    3. Knaapen P,
    4. Allaart CP,
    5. Lammertsma AA,
    6. Lubberink M
    . Parametric images of myocardial viability using a single 15O-H2O PET/CT scan. J Nucl Med. 2011;52:745–749.
    OpenUrlAbstract/FREE Full Text
  30. 30.↵
    1. Rimoldi OE,
    2. Drake-Holland AJ,
    3. Noble MI,
    4. Camici PG
    . Basal and hyperaemic myocardial blood flow in regionally denervated canine hearts: an in vivo study with positron emission tomography. Eur J Nucl Med Mol Imaging. 2007;34:197–205.
    OpenUrlCrossRefPubMed
  • Received for publication January 13, 2015.
  • Accepted for publication July 16, 2015.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 56 (11)
Journal of Nuclear Medicine
Vol. 56, Issue 11
November 1, 2015
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Use of a Single 11C-Meta-Hydroxyephedrine Scan for Assessing Flow–Innervation Mismatches in Patients with Ischemic Cardiomyopathy
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Use of a Single 11C-Meta-Hydroxyephedrine Scan for Assessing Flow–Innervation Mismatches in Patients with Ischemic Cardiomyopathy
Hendrik J. Harms, Mark Lubberink, Stefan de Haan, Paul Knaapen, Marc C. Huisman, Robert C. Schuit, Albert D. Windhorst, Cornelis P. Allaart, Adriaan A. Lammertsma
Journal of Nuclear Medicine Nov 2015, 56 (11) 1706-1711; DOI: 10.2967/jnumed.115.154377

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Use of a Single 11C-Meta-Hydroxyephedrine Scan for Assessing Flow–Innervation Mismatches in Patients with Ischemic Cardiomyopathy
Hendrik J. Harms, Mark Lubberink, Stefan de Haan, Paul Knaapen, Marc C. Huisman, Robert C. Schuit, Albert D. Windhorst, Cornelis P. Allaart, Adriaan A. Lammertsma
Journal of Nuclear Medicine Nov 2015, 56 (11) 1706-1711; DOI: 10.2967/jnumed.115.154377
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Abstract
    • MATERIALS AND METHODS
    • RESULTS
    • DISCUSSION
    • CONCLUSION
    • DISCLOSURE
    • Acknowledgments
    • Footnotes
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • Myocardial Blood Flow and Innervation Measures from a Single Scan: An Appealing Concept but a Challenging Paradigm
  • This Month in JNM
  • PubMed
  • Google Scholar

Cited By...

  • MR/PET Imaging of the Cardiovascular System
  • Impaired Myocardial Sympathetic Innervation Is Associated with Diastolic Dysfunction in Heart Failure with Preserved Ejection Fraction: 11C-Hydroxyephedrine PET Study
  • Automatic Extraction of Myocardial Mass and Volume Using Parametric Images from Dynamic Nongated PET
  • Noninvasive Quantification of Myocardial 11C-Meta-Hydroxyephedrine Kinetics
  • Myocardial Blood Flow and Innervation Measures from a Single Scan: An Appealing Concept but a Challenging Paradigm
  • Google Scholar

More in this TOC Section

  • Feasibility of Ultra-Low-Activity 18F-FDG PET/CT Imaging Using a Long–Axial-Field-of-View PET/CT System
  • Cardiac Presynaptic Sympathetic Nervous Function Evaluated by Cardiac PET in Patients with Chronotropic Incompetence Without Heart Failure
  • Validation and Evaluation of a Vendor-Provided Head Motion Correction Algorithm on the uMI Panorama PET/CT System
Show more Clinical Investigations

Similar Articles

Keywords

  • innervation–blood flow mismatch
  • Sympathetic denervation
  • 11C-HED
  • arrhythmias
SNMMI

© 2025 SNMMI

Powered by HighWire