Skip to main content

Main menu

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI

User menu

  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Journal of Nuclear Medicine
  • SNMMI
    • JNM
    • JNMT
    • SNMMI Journals
    • SNMMI
  • Subscribe
  • My alerts
  • Log in
  • Log out
  • My Cart
Journal of Nuclear Medicine

Advanced Search

  • Home
  • Content
    • Current
    • Ahead of print
    • Past Issues
    • JNM Supplement
    • SNMMI Annual Meeting Abstracts
    • Continuing Education
    • JNM Podcasts
  • Subscriptions
    • Subscribers
    • Institutional and Non-member
    • Rates
    • Journal Claims
    • Corporate & Special Sales
  • Authors
    • Submit to JNM
    • Information for Authors
    • Assignment of Copyright
    • AQARA requirements
  • Info
    • Reviewers
    • Permissions
    • Advertisers
  • About
    • About Us
    • Editorial Board
    • Contact Information
  • More
    • Alerts
    • Feedback
    • Help
    • SNMMI Journals
  • View or Listen to JNM Podcast
  • Visit JNM on Facebook
  • Join JNM on LinkedIn
  • Follow JNM on Twitter
  • Subscribe to our RSS feeds
Research ArticleSupplement

Clinical Implementation of Total-Body PET in China

Yaping Wu, Tao Sun, Yee Ling Ng, Jianjun Liu, Xiaohua Zhu, Zhaoping Cheng, Baixuan Xu, Nan Meng, Yun Zhou and Meiyun Wang
Journal of Nuclear Medicine May 2024, 65 (Supplement 1) 64S-71S; DOI: https://doi.org/10.2967/jnumed.123.266977
Yaping Wu
1Department of Medical Imaging, Henan Provincial People’s Hospital, Zhengzhou, China;
2People’s Hospital of Zhengzhou University, Zhengzhou, China;
3Institute for Integrated Medical Science and Engineering, Henan Academy of Sciences, Zhengzhou, China;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tao Sun
4Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yee Ling Ng
5Central Research Institute, United Imaging Healthcare Group Co., Ltd., Shanghai, China;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jianjun Liu
6Department of Nuclear Medicine, RenJi Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Xiaohua Zhu
7Department of Nuclear Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Zhaoping Cheng
8Department of Nuclear Medicine, First Affiliated Hospital of Shandong First Medical University and Shandong Provincial Qianfoshan Hospital, Jinan, China; and
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Baixuan Xu
9Department of Nuclear Medicine, Chinese PLA General Hospital, Beijing, China
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Nan Meng
1Department of Medical Imaging, Henan Provincial People’s Hospital, Zhengzhou, China;
2People’s Hospital of Zhengzhou University, Zhengzhou, China;
3Institute for Integrated Medical Science and Engineering, Henan Academy of Sciences, Zhengzhou, China;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Yun Zhou
5Central Research Institute, United Imaging Healthcare Group Co., Ltd., Shanghai, China;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Meiyun Wang
1Department of Medical Imaging, Henan Provincial People’s Hospital, Zhengzhou, China;
2People’s Hospital of Zhengzhou University, Zhengzhou, China;
3Institute for Integrated Medical Science and Engineering, Henan Academy of Sciences, Zhengzhou, China;
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • PDF
Loading

Visual Abstract

Figure
  • Download figure
  • Open in new tab
  • Download powerpoint

Abstract

Total-body (TB) PET/CT is a groundbreaking tool that has brought about a revolution in both clinical application and scientific research. The transformative impact of TB PET/CT in the realms of clinical practice and scientific exploration has been steadily unfolding since its introduction in 2018, with implications for its implementation within the health care landscape of China. TB PET/CT’s exceptional sensitivity enables the acquisition of high-quality images in significantly reduced time frames. Clinical applications have underscored its effectiveness across various scenarios, emphasizing the capacity to personalize dosage, scan duration, and image quality to optimize patient outcomes. TB PET/CT’s ability to perform dynamic scans with high temporal and spatial resolution and to perform parametric imaging facilitates the exploration of radiotracer biodistribution and kinetic parameters throughout the body. The comprehensive TB coverage offers opportunities to study interconnections among organs, enhancing our understanding of human physiology and pathology. These insights have the potential to benefit applications requiring holistic TB assessments. The standard topics outlined in The Journal of Nuclear Medicine were used to categorized the reviewed articles into 3 sections: current clinical applications, scan protocol design, and advanced topics. This article delves into the bottleneck that impedes the full use of TB PET in China, accompanied by suggested solutions.

  • PET
  • total-body PET/CT
  • high-quality imaging
  • ultrafast scan
  • low dose
  • parametric imaging

Clinical PET/CT scanners typically have an axial field of view of 15–30 cm, primarily determined by the need to encompass a single region. Short-axial-field-of-view scanners are characterized by suboptimal signal collection efficiency, because they collect less than 1% of the available signal (1). This issue can be addressed by extending the detector rings to cover the entire body, which is called total-body (TB) PET. The inaugural human TB PET system, with a remarkable 2-m length (uEXPLORER; United Imaging Healthcare), pioneered this concept in 2018 (1). Another commercially available system, the Siemens Biograph Vision Quadra, offers a 104-cm length (2). A prototype with scalable length is under development (3).

TB PET/CT has revolutionized molecular imaging in clinical and scientific domains. Long-axial-field-of-view PET systems have exhibited 40-fold enhancement in sensitivity, image quality, and the capabilities of molecular imaging compared with conventional PET/CT (4). The first human TB PET/CT images were reported in 2019, marking the inception of widespread clinical use. In China, the uEXPLORER PET/CT system found initial application at Zhongshan Hospital and was rapidly adopted by numerous hospitals across the country, totaling 16 installations as of September 2023. uEXPLORER use is expected to increase at a rate of 6–7 units per year in China.

TB PET/CT systems offer greatly improved sensitivity, detecting micrometastases, reducing injection dose, and shortening scan durations, all of which have substantial clinical implications. Moreover, a TB PET/CT system enables dynamic PET imaging of metabolic processes and tracer biodistribution throughout the body, promising advancements in drug development and clinical translation. However, TB PET/CT imaging presents challenges, including radiation exposure, acquisition and maintenance costs, the complexity of implementing dynamic scans, and the necessity for standardized protocols across various sites and settings.

With 16 TB PET scanners installed in China, this review explores clinical implementation studies of TB PET/CT in China and provides an overview of key findings. This review addresses the challenges encountered and offers perspectives into the future directions of TB PET research and its impact on health care.

CURRENT CLINICAL APPLICATIONS

18F-FDG Oncologic Imaging

18F-FDG is a well-established radiopharmaceutical agent that is widely used in TB PET/CT examinations for oncologic diseases and yields encouraging results (Fig. 1) (5). A consensus on oncologic 18F-FDG TB PET/CT imaging that used extensive clinical expertise has been published (6). In the realm of early tumor diagnosis, TB PET/CT demonstrates heightened sensitivity, particularly in detecting small or low-uptake lesions (7). This superiority is evident in colorectal cancer (8). In addition, TB PET/CT is used to assess neuroendocrine tumors, distinguish benign from malignant lymph nodes, and address issues of tumor recurrence and metastasis (9). Xie et al. (10) found that TB PET/CT aids in exploring potential correlations between lung cancer and brain metastases. TB PET/CT also aids in treatment planning by identifying immunotherapy-responsive patients (11) and evaluating pleural involvement in lung cancer, especially solid nodules (12). TB PET/CT detects and locates primary ectopic pheochromocytomas, facilitating early diagnosis and treatment (13).

FIGURE 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 1.

Subjective overall image quality at various acquisition times using full dose, with ringlike 18F-FDG uptake lesion in liver shown in maximum intensity projection (A–F) and axial view (G–L) for 900- to 18-s groups. Overall image scores of 5, 4, 3, 2, and 1 were assigned to 180-, 120-, 60-, 30-, and 18-s groups, respectively. (Reprinted with permission of (5).)

Non–18F-FDG Oncologic Imaging

The clinical application of non–18F-FDG tracers in oncology is an active focus of TB PET/CT research in China. The radioligand 68Ga-N188 offers a noninvasive quantification of nectin-4 expression in advanced urothelial carcinoma. TB PET/CT may aid in selecting patients likely to respond to enfortumab vedotin and in predicting their response, optimizing targeted nectin-4 therapy (14). Dynamic 68Ga-fibroblast activation protein inhibitor (FAPI)-04 TB PET/CT imaging in pancreatic and gastric cancer enabled the study of 68Ga-FAPI-04 kinetics in normal organs and lesions. Research by Li et al. (15) suggests the potential of 11C-methionine–based TB PET/CT for monitoring multiple myeloma and stratifying risk. Parametric imaging proved to have superior quantification and enhanced lesion contrast compared with standard SUV images (16). In addition, using a half-dose of 68Ga-FAPI-04 in TB PET/CT imaging reduced acquisition time to 120 s while maintaining acceptable image quality and achieving a 100% tumor detection rate (17).68Ga-FAPI PET/CT may outperform 18F-FDG PET/CT in staging lung cancer (18). Evaluation of 18F-AlF-P-FAPI demonstrated specific uptake, rapid internalization, and low cellular efflux, showing results for primary tumors and lymph node metastases comparable to those of 18F-FDG (19). Recent studies have illustrated that the TB PET/CT, when coupled with 68Ga-prostate-specific membrane antigen (PSMA)-11, offers advanced insights into metabolic heterogeneity (20) and enhanced lesion detection in prostate cancer patients using TB parametric imaging (21), as well as highlighting the improved detection rate compared with conventional PET (22).

A HER2 molecular probe based on Affibody molecules (Affibody AB), 18F-AlF-RESCA-HER2-BCH, exhibits improved tumor uptake and renal clearance, reducing the renal absorbed dose and enhancing its clinical value for targeted radionuclide therapy (23). 18F-FAPI-42, a newly developed FAP-specific cancer imaging tracer, demonstrates optimal imaging 1 h after injection, displaying high uptake and clear lesion visualization (Fig. 2) (24). 68Ga-HNI01 has high specificity for carcinoembryonic antigen in vivo, which can effectively detect colorectal cancer lesions and identify small metastases, making it an ideal tool for selecting patients for anti–carcinoembryonic antigen therapy (Fig. 3) (25).

FIGURE 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 2.

TB PET monitoring of biodistribution and optimization of acquisition time. (A) Maximum-intensity projection images of 18F-FAPI-42 at 5, 10, 15, 20, 65, and 120 min after injection in patient 21 (female). (B) Time–activity curves of 18F-FAPI-42 at various time points after injection. (C) Tumor SUVmax–to–organ SUVmean ratios at various time points after 18F-FAPI-42 injection, excluding tumor SUVmax–to–brain SUVmean ratio. (Reprinted with permission of (24).)

FIGURE 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 3.

68Ga-HNI01 PET images in patients with colorectal cancer primary tumors. (A) Reconstructed dynamic whole-body PET/CT maximum-intensity projection (MIP) images of 68Ga-HNI01 in patient 10 (10 frames). (B) MIP images from 68Ga-HNI01 PET/CT (left) and 18F-FDG PET/CT (right) in patient 10 with abnormal intestinal activity uptake. (C) MIP images from 68Ga-HNI01 PET/CT (left) and 18F-FDG PET/CT (right) in patient 4 with normal intestinal activity uptake. (D) Time courses and fitting curves (fit spline or locally weighted scatterplot smoothing) of 68Ga-HNI01 uptake in normal tissues and tumors for 3 patients in terms of SUVmax. (E) Immunohistochemical staining for carcinoembryonic antigen in tumor samples from patients 1 and 4. A.U. = abnormal uptake; C = cecum; G.E.J. = gastroesophageal junction; K = kidney; p.i. = postinjection; T = tumor. (Reprinted with permission of (25).)

Nononcologic Imaging

In nononcologic fields, TB PET/CT demonstrates high diagnostic potential, with heightened sensitivity in detecting early inflammation, particularly in vasculitis cases (26,27). It aids in gauging infection severity and assisting treatment strategy development. With its extensive detector coverage and sensitivity, TB PET/CT enables comprehensive assessments of TB glucose uptake and vascular wall lesions, yielding promising outcomes (28). Increased 18F-FDG uptake in the distal spinal cord has been identified in young individuals without diabetes or those with low fasting blood sugar levels (29). Yu et al. (30) used TB PET/CT to evaluate radiation accumulation within salivary glands, revealing that oral vitamin C effectively mitigates radiation-related adverse effects. A growing number of studies reveal the skeleton’s endocrine role in influencing glucose metabolism and human glucose homeostasis. Scientists used state-of-the-art TB PET/CT to investigate in vivo glucose uptake and distribution across the human skeleton, reinforcing its significance in regulating glucose metabolism and providing insights into age- and obesity-related factors (31).

Although 11C-2ß-carbomethoxy-3ß-(4-fluorophenyl)tropane PET/CT is widely used for early Parkinson disease (PD) diagnosis, its short half-life and limited understanding of its biologic distribution pose challenges. TB PET/CT dynamic imaging confirms excellent systemic distribution, minimal internal radiation exposure, and high imaging quality for 11C-2ß-carbomethoxy-3ß-(4-fluorophenyl)tropane, making it suitable for PD diagnosis in patients requiring multiple follow-up examinations (32). Similarly, uEXPLORER PET/CT can simultaneously measure the time–activity curve of 13N-ammonia in all body organs, providing more precise information about biologic distribution and radiation dose estimation (33).

SCAN PROTOCOL DESIGN

Short Scan Time

The high sensitivity of TB PET/CT allows data acquisition time to be curtailed without compromising image quality, thus optimizing clinical practice and benefiting patients (34). Reduced scan times enhance throughput and patient comfort even as they effectively minimize motion-induced artifacts. For full-dose (3.7 MBq/kg) TB PET/CT, a 2-min scan in oncologic patients yields satisfactory image quality (Fig. 1) (5) and matches conventional PET/CT in diagnostic performance (35). Even a 30- to 40-s TB PET/CT scan suffices for intolerant patients and provides image quality that rivals conventional PET/CT (36,37). Research confirms good image quality and diagnostic efficacy even at lower doses. In oncology patients, a 2-min TB PET/CT with half-dose (1.85 MBq/kg) 18F-FDG offers acceptable performance, whereas a 5- to 8-min scan aligns well with clinical practice needs (22,38–40). Ultralow (one tenth, 0.37 MBq/kg) 18F-FDG activity with an 8-min acquisition is clinically feasible (41), and a 2-min acquisition can achieve acceptable image quality (42). Image quality is contingent on factors such as tracer activity, acquisition time, and body mass. Research underscores the quadratic relationship between body mass index and injected activity (43) for oncology patients undergoing TB PET/CT imaging.

Reducing scan times helps minimize the impact of patient movement, especially during chest scans, where respiratory motion can cause image blurring. Respiration-gated imaging with a reduced scan time on TB PET/CT outperforms ungated imaging in terms of lesion detectability, offering promising clinical applications (44). If TB PET/CT’s ultrafast imaging capabilities are leveraged, a 20-s breath-hold acquisition will prove practical for reducing motion artifacts and shows potential for enhancing lesion detection, particularly in stage IA pulmonary adenocarcinoma (Fig. 4) (45).

FIGURE 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 4.

Breath-hold (BH) acquisition in TB PET. Images of 59-y-old man with lung adenocarcinoma show solitary solid lung nodule in right lower lobe in axial, coronal, and sagittal chest CT (top row), PET (middle row), and PET/CT (bottom row). (A) Free-breathing (FB) PET/CT. (B) BH PET/CT. Blurred uptake area results from breathing artifacts in FB PET image. (Reprinted with permission of (45).)

TB PET/CT’s potential for shorter scan times applies to exploring alternative radiotracers, such as 68Ga-PSMA and 68Ga-FAPI. Combining early dynamic 68Ga-PSMA PET (75–360 s) with static imaging at 60 min after injection can circumvent interference from urinary bladder activity, facilitating the detection of pathologic lesions with low PSMA uptake (46). Research indicates that TB 68Ga-FAPI-04 PET/CT images, obtained within a 30-s acquisition at 5 min after injection, yield diagnostic results similar to those of traditional scans conducted 60 min after injection with a 300-s acquisition. This reduction in waiting and acquisition times enhances patient throughput and comfort (47).

Low Injection Dose

The attractiveness of minimal TB PET doses lies in their reduction of radiation exposure (48). Studies demonstrated that half (22,38), one-tenth (8,48,49), or even one-thirtieth (50) doses potentially reduced the internal radiation effective dose in PET/CT examinations to 0.6–0.9 mSv. During the scanning process, CT plays a pivotal role in 3 stages: localization, attenuation correction, and diagnosis. A study on TB PET/CT for pediatric lymphoma reveals a 66.1% reduction in effective dose using low-dose CT, without compromising diagnostic accuracy and staging efficacy (51). Combining attenuation-corrected CT with artificial intelligence (AI) techniques empowers the reconstruction of ultra-low-dose CT scans as an alternative to diagnostic CT in specific scenarios (52). When the rich anatomic data from long-axial-field-of-view TB PET images are used as input, an AI application that uses a deep learning reconstruction algorithm can potentially enable the image reconstruction process without additional CT images for attenuation and scattering corrections (53). However, a drawback was the loss in converting 3-dimensional sinograms to 2 dimensions, which introduced noise, lost spatial information, and resulted in an incomplete recovery of details in the ground truth images. These low-dose methods hold promise for more efficient execution of multiple TB PET/CT scans.

Enhanced TB PET sensitivity offers significant advantages for pediatric patients, who are more susceptible to risk of radiation exposure from PET and CT scans. TB PET/CT can reduce the administered 18F-FDG dose to one-thirtieth while preserving image quality and lesion detectability. Optimal image quality is attainable with a one-tenth dose and a 10-min scan (Fig. 5) (50). Pediatric patients, receiving half the standard dose, require only 150 s of raw data to generate clear PET images displaying lesions.

FIGURE 5.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 5.

Subjective overall image quality at different doses. 18F-FDG PET image of 1.9-y-old male patient, weighing 10 kg with Langerhans cell histiocytosis, is reconstructed at 600, 300, 60, 40, and 20 s and depicted in maximum-intensity projection and axial views (A–E), representing full, half, one-tenth, one-fifteenth, and one-thirtieth dose, respectively. Effective doses are shown in parentheses. (Reprinted with permission of (50).)

Dual Tracer Single Scan

Various radiotracers provide complementary insights into lesion characteristics, contributing to precise diagnosis. For instance, combining 68Ga-DOTATATE PET/CT with 18F-FDG PET/CT effectively diagnoses and evaluates neuroendocrine neoplasm heterogeneity (54). A streamlined approach proposes a single CT scan paired with a dual-tracer (18F-FDG and 68Ga-DOTA-FAPI-04) imaging protocol. This protocol effectively amalgamates the benefits of both tracers, ultimately enhancing diagnostic precision. It also significantly reduces both scan time and radiation exposure, making it clinically applicable (55). This protocol may serve as a supplementary approach to 18F-FDG PET/CT for suitable patients, broadening the scope of oncologic imaging using 68Ga-DOTA-FAPI-04 PET/CT.

OTHER ADVANCED TOPICS

Dynamic Imaging

TB PET/CT’s sensitivity and TB coverage provide unprecedented advantages for dynamic scanning. Its impressive temporal and spatial resolution forms a robust foundation for dynamic data analysis, essential for TB exploration of radiotracer biodistribution and kinetic parameters, whether using a full or reduced dose (48). For instance, dynamic scanning reveals variation in uptake and clearance among normal organ types, aiding assessment of tracer kinetics (41,56,57). Using dynamic frame reconstruction at 0.5-s intervals can demonstrate a pediatric patient’s movements during sleep (58). Dynamic scanning usually necessitates data collection exceeding 60 min; by leveraging the superior image quality provided by TB PET, acquisition times to 45 min may still obtain kinetic metrics for 18F-FDG (59). The clinical feasibility of ultra-low-dose 18F-FDG TB PET/CT imaging has been validated by dynamic imaging through both quantitative and qualitative analyses (41). Dynamic TB PET imaging also enables the attainment of comparable kinetic metrics (49) and tumor-to-background ratios in lung adenocarcinoma patients (48), which demonstrates that equivalency extends between normal and low-dose dynamic imaging.

For precise early activity measurement, shorter frame durations are essential, albeit at the cost of a reduced signal-to-noise ratio. Conventional denoising methods, such as the nonlocal mean method, often address individual frames or slices (60). Adjacent frames exhibit an anticipated pattern in voxel activity, allowing the use of interframe information to enhance image quality through pixel-level time–activity curve correction (61). Motion correction is also vital in maintaining image quality in dynamic TB PET imaging. It effectively reduces the impact of random body movements on dynamic images and may prove beneficial for comprehensive TB assessment, such as brain–gut axis and systemic disease imaging (62).

A closely related topic to dynamic imaging is dosimetry, which is vital for radiation protection, dose optimization, image quality enhancement, and workflow simplification. Traditional PET struggles with precise internal dose assessment because of limited axial coverage. TB PET/CT’s dynamic scanning enables detailed voxel-based radiation dose calculations, ensuring accurate total internal dosimetry (63). This approach applies to tracers such as 68Ga-PSMA-11 (64), 68Ga-FAPI-04 (64), 11C-2ß-carbomethoxy-3ß-(4-fluorophenyl)tropane (32), and 13N-ammonia (33), offering insights for optimizing dose and workflow in future clinical settings (64).

Kinetic Modeling

The widely adopted SUV from a single time frame suffices for many clinical purposes. Nevertheless, dynamic scans using multiple time frames offer more comprehensive metabolic insights. Parametric imaging, facilitated by appropriate kinetic models, generates quantitative images and parameters with diverse applications in advanced diagnosis, treatment assessment, therapy management, and drug or tracer development (65). A study of healthy volunteers revealed significant variations in kinetic and metabolic rates of 18F-FDG across organs (66). TB dynamic PET imaging using ultralow injected activity achieved pertinent kinetic metrics for 18F-FDG and maintained image contrast comparable to that of full-activity imaging (49). Wu et al. (67) performed qualitative and quantitative comparisons between metabolic rate images from dynamic 18F-FDG imaging and delayed images. The clinical values in improved lesion detection and differential diagnosis were evaluated for the same group of patients. The Patlak model is increasingly favored for 18F-FDG TB PET dynamic imaging because of its simplicity (60) and predictive value in immunochemotherapy response (68).

Scanning protocols have emerged to shorten the total imaging time (Fig. 6) (59,60,69). The derived Ki and K1 values from a protocol with dual time windows, comprising a 10-min early scan and a 5-min late scan, showed strong agreement with the results from a full 60-min dynamic scan (69). An dual-injection protocol, involving an initial scan 50–60 min after injection followed by a second injection at 56 min, reduces TB Ki imaging time to 10 min with a single CT scan, enabling the incorporation of parametric imaging into clinical practice (70). In addition, K1 images can be estimated using only data from the first 90 s after injection with a 1-tissue compartment model (71). When it comes to non–18F-FDG tracers, researchers are also interested in their kinetic information and effect in clinics. Analyzing dynamic data for 68Ga-PSMA-11 (20) and 68Ga-FAPI-04 (72) establishes a strong correlation between the mean tumor-to-blood ratio and the total distribution volume, which would be the preferred measurement tool for semiquantitative assessment of tumor uptake and treatment response evaluation. In addition, 11C-methionine TB PET scans capture dynamic changes in myeloma metabolism by tracking radiotracer distribution in vivo. This approach unveils the metabolic process of 11C-methionine in multiple myeloma through kinetic modeling and found that risk stratification in multiple myeloma based on the k4 value holds promise (15).

FIGURE 6.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 6.

Ki images with various settings. These 16 schemes use different durations (40, 30, 20, and 16 min), input functions (image-derived input function [IDIF] and population-based input function [PBIF]), and application with or without nonlocal means (NLM) filter. Arrow indicates lesion. (Reprinted from (60).)

Connectome Analysis

TB PET’s exceptional sensitivity enables high-temporal-resolution TB dynamic imaging, facilitating the study of organ connectomes to comprehend human physiology and pathology. This capability allows measurement of simultaneous or delayed signal changes in different organs, paving the way for causal relationships that hold promise for medical interventions (73). Maintaining health relies on the stability of interorgan interactions for homeostasis. Metabolic abnormalities in certain organs can disrupt this equilibrium, potentially causing diseases. Consequently, using organ networks as diagnostic tools offers a systemic perspective to identify individual metabolic abnormalities (Fig. 7) (74). When investigating the brain–gastrointestinal relationships in PD through dynamic 11C-2ß-carbomethoxy-3ß-(4-fluorophenyl)tropane TB PET/CT imaging of dopamine transporters, the results suggest a loss of interactions between gastrointestinal organs and PD-related brain nuclei in PD patients (75). Moreover, studying metabolic interactions between organs in overweight and obese patients using TB PET underscores the significance of understanding organ connectivity for a comprehensive assessment of health and disease (76). Exploiting the advantages of TB PET low-dose imaging expands its application to health assessments and treatment efficacy evaluations.

FIGURE 7.
  • Download figure
  • Open in new tab
  • Download powerpoint
FIGURE 7.

Abnormal metabolic connectivity between organs. (A–C) Metabolic connectivity plots show 2 abnormal subjects and control, with middle images displaying coronal SUV slices and side plots showing network connections between organs. Abnormal subjects demonstrated denser connectivity and higher strength at relevant nodes than did control network, marked with red arrows for SUV uptake. CER = cerebellum; Covid-19 = coronavirus disease 2019; CSF = cerebrospinal fluid; GI = gastrointestinal; LV = left ventricle; SF = frontal cortex; WM = white matter. (Reprinted from (74).)

AI Application

AI is an effective tool that enhances image quality in TB PET studies. High-quality TB PET images can serve as training labels when training deep learning models for denoise (77) and enhance contrast (78) in PET images from conventional devices, as well as improving the quality of low-dose (79) or ultrafast acquisition (80) TB PET images. AI methods also facilitate the reconstruction and synthesis of parametric images (81). A deep learning–driven approach has demonstrated its capacity to create superior direct Patlak Ki images without necessitating an input function (82), which may mitigate the challenge posed by protracted scan times of dynamic PET. AI-based image quality control enables automated generation of comprehensive and intricate image quality assessment reports (83). Lesion segmentation is time-consuming, and automatic segmentation performance is often unsatisfactory. By harnessing the high contrast provided by TB PET parametric images, the accuracy of automatic lesion segmentation can be significantly improved, integrating Ki parametric images with PET and CT images (84).

SUMMARY

Over the years, TB PET/CT has achieved sensitivity and capabilities that advanced the realm of molecular imaging. This article encapsulates the key findings of TB PET in China, covering both oncologic and nononcologic applications and delving into advanced topics such as dynamic parametric imaging, component analysis, and AI. It is evident that TB PET is making significant strides in clinical applications in China, promising to enhance clinical efficiency.

Despite the achievements, the application of TB PET in China encounters challenges. From an economic standpoint, the purchase and maintenance costs of TB PET are higher than those of conventional PET. In China, the price of a TB scan is about ¥6,000–¥9,000 (∼$832.72–$1,250.57), which is the same or slightly higher than that of a conventional full-body scan from eye to thigh. Many hospitals in China have a large patient population and limited space for equipment installation. The high throughput of TB PET can effectively alleviate this problem. Furthermore, beyond its clinical value, TB PET may be more important as a scientific platform to enhance research capabilities, potentially outweighing economic concerns. The legal and regulatory frameworks are incomplete, and non–18F-FDG radiotracers lack approval. Meanwhile, the discipline of PET started relatively late in China, resulting in a shortage of expertise. In addition, limited familiarity with PET technology and its applications in other disciplines hinders multidisciplinary collaboration in clinical applications. For example, application and research in nononcologic disease are relatively limited compared with oncologic disease. However, efforts have been initiated to formulate a long-term plan that encourages the development of nuclear medicine, and we believe that TB PET will play an important role in Chinese clinical practice.

DISCLOSURE

This work was partially supported by the National Key R&D Program of China (2023YFC2414200), National Natural Science Foundation of China (82371934), and Joint Fund of Henan Province Science and Technology R&D Program (225200810062). Yee Ling Ng and Yun Zhou are employed by United Imaging Healthcare. No other potential conflict of interest relevant to this article was reported.

  • © 2024 by the Society of Nuclear Medicine and Molecular Imaging.

REFERENCES

  1. 1.↵
    1. Cherry SR,
    2. Jones T,
    3. Karp JS,
    4. Qi J,
    5. Moses WW,
    6. Badawi RD
    . Total-body PET: maximizing sensitivity to create new opportunities for clinical research and patient care. J Nucl Med. 2018;59:3–12.
    OpenUrlAbstract/FREE Full Text
  2. 2.↵
    1. Alberts I,
    2. Hünermund J-N,
    3. Prenosil G,
    4. et al
    . Clinical performance of long axial field of view PET/CT: a head-to-head intra-individual comparison of the Biograph Vision Quadra with the Biograph Vision PET/CT. Eur J Nucl Med Mol Imaging. 2021;48:2395–2404.
    OpenUrl
  3. 3.↵
    1. Pantel AR,
    2. Viswanath V,
    3. Daube-Witherspoon ME,
    4. et al
    . PennPET Explorer: human imaging on a whole-body imager. J Nucl Med. 2020;61:144–151.
    OpenUrlAbstract/FREE Full Text
  4. 4.↵
    1. Badawi RD,
    2. Shi H,
    3. Hu P,
    4. et al
    . First human imaging studies with the EXPLORER total-body PET scanner. J Nucl Med. 2019;60:299–303.
    OpenUrlAbstract/FREE Full Text
  5. 5.↵
    1. Zhang Y-Q,
    2. Hu P-C,
    3. Wu R-Z,
    4. et al
    . The image quality, lesion detectability, and acquisition time of 18F-FDG total-body PET/CT in oncological patients. Eur J Nucl Med Mol Imaging. 2020;47:2507–2515.
    OpenUrl
  6. 6.↵
    1. Yu H,
    2. Gu Y,
    3. Fan W,
    4. et al
    . Expert consensus on oncological [18F]FDG total-body PET/CT imaging (version 1). Eur Radiol. 2023;33:615–626.
    OpenUrl
  7. 7.↵
    1. Chen X,
    2. Hu P,
    3. Yu H,
    4. et al
    . Head-to-head intra-individual comparison of total-body 2-[18F]FDG PET/CT and digital PET/CT in patients with malignant tumor: how sensitive could it be? Eur Radiol. 2023;33:7890–7898.
    OpenUrl
  8. 8.↵
    1. Tan H,
    2. Cai D,
    3. Sui X,
    4. et al
    . Investigating ultra-low-dose total-body [18F]-FDG PET/CT in colorectal cancer: initial experience. Eur J Nucl Med Mol Imaging. 2022;49:1002–1011.
    OpenUrl
  9. 9.↵
    1. Fu F,
    2. Li X,
    3. Wu Y,
    4. et al
    . Total-body dynamic PET/CT of micro-metastatic lymph node in a patient with lung cancer. Eur J Nucl Med Mol Imaging. 2021;48:1678–1679.
    OpenUrl
  10. 10.↵
    1. Xie X,
    2. Lu W,
    3. Ma D,
    4. et al
    . Metabolic and textural changes in the brain of non‐small cell lung cancer patients: a total‐body positron emission tomography/computed tomography study. iRADIOLOGY. 2023;1:109–119.
    OpenUrl
  11. 11.↵
    1. Wang D,
    2. Zhang X,
    3. Liu H,
    4. et al
    . Assessing dynamic metabolic heterogeneity in non-small cell lung cancer patients via ultra-high sensitivity total-body [18F]FDG PET/CT imaging: quantitative analysis of [18F]FDG uptake in primary tumors and metastatic lymph nodes. Eur J Nucl Med Mol Imaging. 2022;49:4692–4704.
    OpenUrl
  12. 12.↵
    1. Wang M-L,
    2. Zhang H,
    3. Yu H-J,
    4. et al
    . An initial study on the comparison of diagnostic performance of 18F-FDG PET/MR and 18F-FDG PET/CT for thoracic staging of non-small cell lung cancer: focus on pleural invasion. Rev Esp Med Nucl Imagen Mol (Engl Ed). 2023;42:16–23.
    OpenUrl
  13. 13.↵
    1. Duan Y,
    2. Xu R,
    3. Liu W,
    4. et al
    . PET/CT in a patient with cardiac paraganglioma. Int J Cardiovasc Imaging. 2021;37:1473–1477.
    OpenUrl
  14. 14.↵
    1. Duan X,
    2. Xia L,
    3. Zhang Z,
    4. et al
    . First-in-human study of the radioligand 68Ga-N188 targeting nectin-4 for PET/CT imaging of advanced urothelial carcinoma. Clin Cancer Res. 2023;29:3395–3407.
    OpenUrl
  15. 15.↵
    1. Li J,
    2. Ni B,
    3. Yu X,
    4. et al
    . Metabolic kinetic modeling of [11C]methionine based on total-body PET in multiple myeloma. Eur J Nucl Med Mol Imaging. 2023;50:2683–2691.
    OpenUrl
  16. 16.↵
    1. Chen R,
    2. Yang X,
    3. Ng YL,
    4. et al
    . First total-body kinetic modeling and parametric imaging of dynamic 68Ga-FAPI-04 PET in pancreatic and gastric cancer. J Nucl Med. 2023;64:960–967.
    OpenUrlAbstract/FREE Full Text
  17. 17.↵
    1. Chen Z,
    2. Wang Y,
    3. Yang X,
    4. et al
    . Feasibility of acquisitions using total-body PET/CT with a half-dose [68Ga]Ga-FAPI-04 activity in oncology patients. Eur J Nucl Med Mol Imaging. 2023;50:3961–3969.
    OpenUrl
  18. 18.↵
    1. Wang L,
    2. Tang G,
    3. Hu K,
    4. et al
    . Comparison of 68Ga-FAPI and 18F-FDG PET/CT in the evaluation of advanced lung cancer. Radiology. 2022;303:191–199.
    OpenUrl
  19. 19.↵
    1. Hu K,
    2. Li J,
    3. Wang L,
    4. et al
    . Preclinical evaluation and pilot clinical study of [18F]AlF-labeled FAPI-tracer for PET imaging of cancer associated fibroblasts. Acta Pharm Sin B. 2022;12:867–875.
    OpenUrl
  20. 20.↵
    1. Chen R,
    2. Ng YL,
    3. Yang X,
    4. et al
    . Assessing dynamic metabolic heterogeneity in prostate cancer patients via total-body [68Ga]Ga-PSMA-11 PET/CT imaging: quantitative analysis of [68Ga]Ga-PSMA-11 uptake in pathological lesions and normal organs. Eur J Nucl Med Mol Imaging. 2024;51:896–906.
    OpenUrl
  21. 21.↵
    1. Chen R,
    2. Ng YL,
    3. Yang X,
    4. et al
    . Comparison of parametric imaging and SUV imaging with [68Ga]Ga-PSMA-11 using dynamic total-body PET/CT in prostate cancer. Eur J Nucl Med Mol Imaging. 2024;51:568–580.
    OpenUrl
  22. 22.↵
    1. Liu Y,
    2. Li L,
    3. Qin Y,
    4. et al
    . Total-body PET/CT with half-dose [68Ga]Ga-PSMA-11 for biochemical recurrent prostate cancer: comparable diagnostic value to short axial field-of-view PET/CT with full-dose [68Ga]Ga-PSMA-11. Eur J Nucl Med Mol Imaging. 2024;51:581–589.
    OpenUrl
  23. 23.↵
    1. Liu J,
    2. Guo X,
    3. Wen L,
    4. et al
    . Comparison of renal clearance of [18F]AlF-RESCA-HER2-BCH and [18F]AlF-NOTA-HER2-BCH in mice and breast cancer patients. Eur J Nucl Med Mol Imaging. 2023;50:2775–2786.
    OpenUrl
  24. 24.↵
    1. Hu K,
    2. Wang L,
    3. Wu H,
    4. et al
    . [18F]FAPI-42 PET imaging in cancer patients: optimal acquisition time, biodistribution, and comparison with [68Ga]Ga-FAPI-04. Eur J Nucl Med Mol Imaging. 2022;49:2833–2843.
    OpenUrl
  25. 25.↵
    1. Li L,
    2. Lin X,
    3. Wang L,
    4. et al
    . Immuno-PET of colorectal cancer with a CEA-targeted [68Ga]Ga-nanobody: from bench to bedside. Eur J Nucl Med Mol Imaging. 2023;50:3735–3749.
    OpenUrl
  26. 26.↵
    1. Adili D,
    2. Cai D,
    3. Wu B,
    4. et al
    . An exploration of the feasibility and clinical value of half-dose 5-h total-body 18F-FDG PET/CT scan in patients with Takayasu arteritis. Eur J Nucl Med Mol Imaging. 2023;50:2375–2385.
    OpenUrl
  27. 27.↵
    1. Duan Y,
    2. Zan K,
    3. Zhao M,
    4. et al
    . The feasibility of quantitative assessment of dynamic 18F-fluorodeoxyglucose PET in Takayasu’s arteritis: a pilot study. Eur J Nucl Med Mol Imaging. 2023;51:81–92.
    OpenUrl
  28. 28.↵
    1. Lu W,
    2. Cheng Z,
    3. Xie X,
    4. et al
    . An atlas of glucose uptake across the entire human body as measured by the total-body PET/CT scanner: a pilot study. Life Metab. 2022;1:190–199.
    OpenUrl
  29. 29.↵
    1. Tan X,
    2. Li D,
    3. Wu X,
    4. et al
    . Physiologically intense FDG uptake of distal spinal cord on total-body PET/CT. Ann Nucl Med. 2022;36:643–650.
    OpenUrl
  30. 30.↵
    1. Yu H,
    2. Lv J,
    3. Hu P,
    4. Chen S,
    5. Shi H
    . Reduction of radiation accumulation in salivary glands through oral vitamin C during 68Ga-PSMA-11 total-body dynamic PET/CT imaging. Nucl Med Commun. 2022;43:166–171.
    OpenUrl
  31. 31.↵
    1. Lu W,
    2. Duan Y,
    3. Li K,
    4. Qiu J,
    5. Cheng Z
    . Glucose uptake and distribution across the human skeleton using state-of-the-art total-body PET/CT. Bone Res. 2023;11:36.
    OpenUrl
  32. 32.↵
    1. Xin M,
    2. Li L,
    3. Wang C,
    4. Shao H,
    5. Liu J,
    6. Zhang C
    . Pilot study on 11C-CFT dynamic imaging using total-body PET/CT: biodistribution and radiation dosimetry in Parkinson’s disease. Front Neurol. 2023;14:1153779.
    OpenUrl
  33. 33.↵
    1. Yu X,
    2. Sun H,
    3. Xu L,
    4. et al
    . Improved accuracy of the biodistribution and internal radiation dosimetry of 13N‐ammonia using a total‐body PET/CT scanner. Med Phys. May 2023;50:5865–5874.
    OpenUrl
  34. 34.↵
    1. Huang Y,
    2. Wang M,
    3. Jiang L,
    4. et al
    . Optimal clinical protocols for total-body 18F-FDG PET/CT examination under different activity administration plans. EJNMMI Phys. 2023;10:14.
    OpenUrl
  35. 35.↵
    1. Hu Y,
    2. Liu G,
    3. Yu H,
    4. Gu J,
    5. Shi H
    . Diagnostic performance of total-body 18F-FDG PET/CT with fast 2-min acquisition for liver tumours: comparison with conventional PET/CT. Eur J Nucl Med Mol Imaging. 2022;49:3538–3546.
    OpenUrl
  36. 36.↵
    1. Hu P,
    2. Zhang Y,
    3. Yu H,
    4. et al
    . Total-body 18F-FDG PET/CT scan in oncology patients: how fast could it be? Eur J Nucl Med Mol Imaging. 2021;48:2384–2394.
    OpenUrl
  37. 37.↵
    1. Zhang Y,
    2. Hu P,
    3. He Y,
    4. et al
    . Ultrafast 30-s total-body PET/CT scan: a preliminary study. Eur J Nucl Med Mol Imaging. 2022;49:2504–2513.
    OpenUrl
  38. 38.↵
    1. He Y,
    2. Gu Y,
    3. Yu H,
    4. et al
    . Optimizing acquisition times for total-body positron emission tomography/computed tomography with half-dose 18F-fluorodeoxyglucose in oncology patients. EJNMMI Phys. 2022;9:45.
    OpenUrl
  39. 39.
    1. Tan H,
    2. Sui X,
    3. Yin H,
    4. et al
    . Total-body PET/CT using half-dose FDG and compared with conventional PET/CT using full-dose FDG in lung cancer. Eur J Nucl Med Mol Imaging. 2021;48:1966–1975.
    OpenUrl
  40. 40.↵
    1. Chen W,
    2. Liu L,
    3. Li Y,
    4. et al
    . Evaluation of pediatric malignancies using total-body PET/CT with half-dose [18F]-FDG. Eur J Nucl Med Mol Imaging. 2022;49:4145–4155.
    OpenUrl
  41. 41.↵
    1. Tan H,
    2. Qi C,
    3. Cao Y,
    4. et al
    . Ultralow-dose [18F]FDG PET/CT imaging: demonstration of feasibility in dynamic and static images. Eur Radiol. 2023;33:5017–5027.
    OpenUrl
  42. 42.↵
    1. Hu Y,
    2. Liu G,
    3. Yu H,
    4. et al
    . Feasibility of acquisitions using total-body PET/CT with an ultra-low 18F-FDG activity. J Nucl Med. 2022;63:959–965.
    OpenUrlAbstract/FREE Full Text
  43. 43.↵
    1. Xiao J,
    2. Yu H,
    3. Sui X,
    4. et al
    . Can the BMI-based dose regimen be used to reduce injection activity and to obtain a constant image quality in oncological patients by 18F-FDG total-body PET/CT imaging? Eur J Nucl Med Mol Imaging. 2021;49:269–278.
    OpenUrl
  44. 44.↵
    1. Liu G,
    2. Chen S,
    3. Hu Y,
    4. et al
    . Respiratory-gated PET imaging with reduced acquisition time for suspect malignancies: the first experience in application of total-body PET/CT. Eur Radiol. 2023;33:3366–3376.
    OpenUrl
  45. 45.↵
    1. Cheng Z,
    2. Chen L,
    3. Wang X,
    4. et al
    . Role of breath-hold lung PET in stage IA pulmonary adenocarcinoma. Insights Imaging. 2023;14:100.
    OpenUrl
  46. 46.↵
    1. Wen J,
    2. Zhu Y,
    3. Li L,
    4. Liu J,
    5. Chen Y,
    6. Chen R
    . Determination of optimal 68Ga-PSMA PET/CT imaging time in prostate cancers by total-body dynamic PET/CT. Eur J Nucl Med Mol Imaging. 2022;49:2086–2095.
    OpenUrl
  47. 47.↵
    1. Chen R,
    2. Yang X,
    3. Yu X,
    4. et al
    . The feasibility of ultra-early and fast total-body [68Ga]Ga-FAPI-04 PET/CT scan. Eur J Nucl Med Mol Imaging. 2023;50:661–666.
    OpenUrl
  48. 48.↵
    1. Lv J,
    2. Yin H,
    3. Yu H,
    4. Liu G,
    5. Shi H
    . The feasibility of ultralow-activity 18F-FDG dynamic PET imaging in lung adenocarcinoma patients through total-body PET/CT scanner. Ann Nucl Med. 2022;36:887–896.
    OpenUrl
  49. 49.↵
    1. Liu G,
    2. Hu P,
    3. Yu H,
    4. et al
    . Ultra-low-activity total-body dynamic PET imaging allows equal performance to full-activity PET imaging for investigating kinetic metrics of 18F-FDG in healthy volunteers. Eur J Nucl Med Mol Imaging. 2021;48:2373–2383.
    OpenUrl
  50. 50.↵
    1. Zhao Y-M,
    2. Li Y-H,
    3. Chen T,
    4. et al
    . Image quality and lesion detectability in low-dose pediatric 18F-FDG scans using total-body PET/CT. Eur J Nucl Med Mol Imaging. 2021;48:3378–3385.
    OpenUrl
  51. 51.↵
    1. Tang S,
    2. Hu Y,
    3. Zeng J,
    4. et al
    . Significant CT dose reduction of 2-[18F]FDG PET/CT in pretreatment pediatric lymphoma without compromising the diagnostic and staging efficacy. Eur Radiol. 2023;33:2248–2257.
    OpenUrl
  52. 52.↵
    1. Hu Y,
    2. Zheng Z,
    3. Yu H,
    4. Wang J,
    5. Yang X,
    6. Shi H
    . Ultra-low-dose CT reconstructed with the artificial intelligence iterative reconstruction algorithm (AIIR) in 18F-FDG total-body PET/CT examination: a preliminary study. EJNMMI Phys. 2023;10:1.
    OpenUrl
  53. 53.↵
    1. Ma R,
    2. Hu J,
    3. Sari H,
    4. et al
    . An encoder-decoder network for direct image reconstruction on sinograms of a long axial field of view PET. Eur J Nucl Med Mol Imaging. 2022;49:4464–4477.
    OpenUrl
  54. 54.↵
    1. Liu G,
    2. Qi C,
    3. Shi H
    . Neuroendocrine neoplasms total-body PET/computed tomography. PET Clin. 2023;18:251–257.
    OpenUrl
  55. 55.↵
    1. Liu G,
    2. Mao W,
    3. Yu H,
    4. Hu Y,
    5. Gu J,
    6. Shi H
    . One-stop [18F]FDG and [68Ga]Ga-DOTA-FAPI-04 total-body PET/CT examination with dual-low activity: a feasibility study. Eur J Nucl Med Mol Imaging. 2023;50:2271–2281.
    OpenUrl
  56. 56.↵
    1. Yin H,
    2. Liu G,
    3. Hu Y,
    4. et al
    . Dynamic total-body PET/CT imaging reveals kinetic distribution of 68Ga-DOTATATE in normal organs. Contrast Media Mol Imaging. 2023;2023:4722499.
    OpenUrl
  57. 57.↵
    1. Ding D,
    2. Zhao H,
    3. Wei D,
    4. et al
    . The first-in-human whole-body dynamic pharmacokinetics study of aptamer. Research. 2023;6:0126.
    OpenUrl
  58. 58.↵
    1. Li Y,
    2. Wang J,
    3. Hu J,
    4. et al
    . PET/CT scan without sedation: how to use total-body PET/CT to salvage child’s involuntary movement? Eur J Nucl Med Mol Imaging. 2023;50:2912–2913.
    OpenUrl
  59. 59.↵
    1. Liu G,
    2. Yu H,
    3. Shi D,
    4. et al
    . Short-time total-body dynamic PET imaging performance in quantifying the kinetic metrics of 18F-FDG in healthy volunteers. Eur J Nucl Med Mol Imaging. 2022;49:2493–2503.
    OpenUrl
  60. 60.↵
    1. Wu Y,
    2. Feng T,
    3. Shen Y,
    4. et al
    . Total-body parametric imaging using the Patlak model: feasibility of reduced scan time. Med Phys. 2022;49:4529–4539.
    OpenUrl
  61. 61.↵
    1. Chen Z,
    2. Wu Y,
    3. Zhang N,
    4. et al
    . High temporal resolution total-body dynamic PET imaging based on pixel-level time–activity curve correction. IEEE Trans Biomed Eng. 2022;69:3689–3702.
    OpenUrl
  62. 62.↵
    1. Sun T,
    2. Wu Y,
    3. Wei W,
    4. et al
    . Motion correction and its impact on quantification in dynamic total-body 18F-fluorodeoxyglucose PET. EJNMMI Phys. 2022;9:62.
    OpenUrl
  63. 63.↵
    1. Hu P,
    2. Lin X,
    3. Zhuo W,
    4. et al
    . Internal dosimetry in F-18 FDG PET examinations based on long-time-measured organ activities using total-body PET/CT: does it make any difference from a short-time measurement? EJNMMI Phys. 2021;8:51.
    OpenUrl
  64. 64.↵
    1. Li L,
    2. Wan L,
    3. Zhao H,
    4. Wang C,
    5. Wei W,
    6. Liu J
    . Biodistribution and radiation dosimetry of multiple tracers on total-body positron emission tomography/computed tomography. Quant Imaging Med Surg. 2023;13:5182–5194.
    OpenUrl
  65. 65.↵
    1. Gu F,
    2. Wu Q
    . Quantitation of dynamic total-body PET imaging: recent developments and future perspectives. Eur J Nucl Med Mol Imaging. 2023;50:3538–3557.
    OpenUrl
  66. 66.↵
    1. Liu G,
    2. Xu H,
    3. Hu P,
    4. et al
    . Kinetic metrics of 18F-FDG in normal human organs identified by systematic dynamic total-body positron emission tomography. Eur J Nucl Med Mol Imaging. 2021;48:2363–2372.
    OpenUrl
  67. 67.↵
    1. Wu Y,
    2. Fu F,
    3. Meng N,
    4. et al
    . The role of dynamic, static, and delayed total-body PET imaging in the detection and differential diagnosis of oncological lesions. Cancer Imaging. 2024;24:2.
    OpenUrl
  68. 68.↵
    1. Wang D,
    2. Qiu B,
    3. Liu Q,
    4. et al
    . Patlak-Ki derived from ultra-high sensitivity dynamic total body [18F]FDG PET/CT correlates with the response to induction immuno-chemotherapy in locally advanced non-small cell lung cancer patients. Eur J Nucl Med Mol Imaging. 2023;50:3400–3413.
    OpenUrl
  69. 69.↵
    1. Wang Z,
    2. Wu Y,
    3. Li X,
    4. et al
    . Comparison between a dual-time-window protocol and other simplified protocols for dynamic total-body 18F-FDG PET imaging. EJNMMI Phys. 2022;9:63.
    OpenUrl
  70. 70.↵
    1. Wu Y,
    2. Feng T,
    3. Zhao Y,
    4. et al
    . Whole-body parametric imaging of 18F-FDG PET using uEXPLORER with reduced scanning time. J Nucl Med. 2022;63:622–628.
    OpenUrlAbstract/FREE Full Text
  71. 71.↵
    1. Feng T,
    2. Zhao Y,
    3. Shi H,
    4. et al
    . Total-body quantitative parametric imaging of early kinetics of 18F-FDG. J Nucl Med. 2021;62:738–744.
    OpenUrlAbstract/FREE Full Text
  72. 72.↵
    1. Chen R,
    2. Yang X,
    3. Yu X,
    4. et al
    . Tumor-to-blood ratio for assessment of fibroblast activation protein receptor density in pancreatic cancer using [68Ga]Ga-FAPI-04. Eur J Nucl Med Mol Imaging. 2023;50:929–936.
    OpenUrl
  73. 73.↵
    1. Shiyam Sundar LK,
    2. Hacker M,
    3. Beyer T
    . Whole-body PET imaging: a catalyst for whole-person research? J Nucl Med. 2023;64:197–199.
    OpenUrlFREE Full Text
  74. 74.↵
    1. Sun T,
    2. Wang Z,
    3. Wu Y,
    4. et al
    . Identifying the individual metabolic abnormities from a systemic perspective using whole-body PET imaging. Eur J Nucl Med Mol Imaging. 2022;49:2994–3004.
    OpenUrl
  75. 75.↵
    1. Xin M,
    2. Li L,
    3. Wang C,
    4. et al
    . An investigation of the “brain-GI” relationships in Parkinson’s disease by imaging dopamine transporter in dynamic 11C-CFT total-body PET/CT [abstract]. J Nucl Med. 2022;63(suppl 2):S2480.
    OpenUrl
  76. 76.↵
    1. Lu W,
    2. Duan Y,
    3. Li K,
    4. Cheng Z,
    5. Qiu J
    . Metabolic interactions between organs in overweight and obesity using total-body positron emission tomography. Int J Obes (Lond). 2024;48:94–102.
    OpenUrl
  77. 77.↵
    1. Huang Z,
    2. Li W,
    3. Wu Y,
    4. et al
    . Short-axis PET image quality improvement based on a uEXPLORER total-body PET system through deep learning. Eur J Nucl Med Mol Imaging. 2023;51:27–39.
    OpenUrl
  78. 78.↵
    1. Lv Y,
    2. Xi C
    . PET image reconstruction with deep progressive learning. Phys Med Biol. 2021;66:105016.
    OpenUrl
  79. 79.↵
    1. Zhang J,
    2. Cui Z,
    3. Jiang C,
    4. Guo S,
    5. Gao F,
    6. Shen D
    . Hierarchical organ-aware total-body standard-dose PET reconstruction from low-dose PET and CT images. IEEE Trans Neural Netw Learn Syst. May 9, 2023 [Epub ahead of print].
  80. 80.↵
    1. Liu E,
    2. Lyu Z,
    3. Yang Y,
    4. et al
    . Sub-minute acquisition with deep learning-based image filter in the diagnosis of colorectal cancers using total-body 18F-FDG PET/CT. EJNMMI Res. 2023;13:66.
    OpenUrl
  81. 81.↵
    1. Huang Z,
    2. Wu Y,
    3. Fu F,
    4. et al
    . Parametric image generation with the uEXPLORER total-body PET/CT system through deep learning. Eur J Nucl Med Mol Imaging. 2022;49:2482–2492.
    OpenUrl
  82. 82.↵
    1. Li Y,
    2. Hu J,
    3. Sari H,
    4. et al
    . A deep neural network for parametric image reconstruction on a large axial field-of-view PET. Eur J Nucl Med Mol Imaging. 2023;50:701–714.
    OpenUrl
  83. 83.↵
    1. Qi C,
    2. Wang S,
    3. Yu H,
    4. et al
    . An artificial intelligence-driven image quality assessment system for whole-body [18F]FDG PET/CT. Eur J Nucl Med Mol Imaging. 2023;50:1318–1328.
    OpenUrl
  84. 84.↵
    1. Huang Z,
    2. Tang S,
    3. Chen Z,
    4. et al
    . TG-Net: combining transformer and GAN for nasopharyngeal carcinoma tumor segmentation based on total-body uEXPLORER PET/CT scanner. Comput Biol Med. 2022;148:105869.
    OpenUrl
  • Received for publication November 4, 2023.
  • Revision received February 13, 2024.
PreviousNext
Back to top

In this issue

Journal of Nuclear Medicine: 65 (Supplement 1)
Journal of Nuclear Medicine
Vol. 65, Issue Supplement 1
May 1, 2024
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
  • Complete Issue (PDF)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word on Journal of Nuclear Medicine.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Clinical Implementation of Total-Body PET in China
(Your Name) has sent you a message from Journal of Nuclear Medicine
(Your Name) thought you would like to see the Journal of Nuclear Medicine web site.
Citation Tools
Clinical Implementation of Total-Body PET in China
Yaping Wu, Tao Sun, Yee Ling Ng, Jianjun Liu, Xiaohua Zhu, Zhaoping Cheng, Baixuan Xu, Nan Meng, Yun Zhou, Meiyun Wang
Journal of Nuclear Medicine May 2024, 65 (Supplement 1) 64S-71S; DOI: 10.2967/jnumed.123.266977

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Share
Clinical Implementation of Total-Body PET in China
Yaping Wu, Tao Sun, Yee Ling Ng, Jianjun Liu, Xiaohua Zhu, Zhaoping Cheng, Baixuan Xu, Nan Meng, Yun Zhou, Meiyun Wang
Journal of Nuclear Medicine May 2024, 65 (Supplement 1) 64S-71S; DOI: 10.2967/jnumed.123.266977
Twitter logo Facebook logo LinkedIn logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One
Bookmark this article

Jump to section

  • Article
    • Visual Abstract
    • Abstract
    • CURRENT CLINICAL APPLICATIONS
    • SCAN PROTOCOL DESIGN
    • OTHER ADVANCED TOPICS
    • SUMMARY
    • DISCLOSURE
    • REFERENCES
  • Figures & Data
  • Info & Metrics
  • PDF

Related Articles

  • No related articles found.
  • PubMed
  • Google Scholar

Cited By...

  • Chinas Innovations in Nuclear Medicine: Global Insights into Clinical Advancements and Impact
  • Advancing Global Nuclear Medicine: The Role and Future Contributions of China
  • Google Scholar

More in this TOC Section

  • The Role of Total-Body PET in Drug Development and Evaluation: Status and Outlook
  • Melanin-Targeting Radiotracers and Their Preclinical, Translational, and Clinical Status: From Past to Future
  • Advancing Global Nuclear Medicine: The Role and Future Contributions of China
Show more Supplement

Similar Articles

Keywords

  • PET
  • total-body PET/CT
  • high-quality imaging
  • ultrafast scan
  • low dose
  • parametric imaging
SNMMI

© 2025 SNMMI

Powered by HighWire