[PDF][PDF] Ruthenium-97 DTPA: a new radiopharmaceutical for cisternography

ZH Oster, P Som, MC Gil, RG Fairchild… - Journal of Nuclear …, 1981 - Soc Nuclear Med
MATERIALS AND METHODS Preliminary investigations were carried out using Ru-103
because of its longer half-life (39.6 d). Ruthe nium-103 chloride* was obtained as a carrier …

[PDF][PDF] Cisternography with chelated complex of 99mTc

P Som, F Hosain, HN Wagner… - Journal of Nuclear …, 1972 - Soc Nuclear Med
UHI/CONCISE COMMUNICATION Page 1 UHI/CONCISE COMMUNICATION
CISTERNOGRAPHY WITH CHELATED COMPLEX OF ""'"Te Prantika Som, Fazle Hosain …

[PDF][PDF] Safety of 169Yb-DTPA in Cisternography

RL Morin, FH DeLand - Journal of Nuclear Medicine, 1974 - Soc Nuclear Med
Chicago Pho/Gamma HP) using a 4,000-hole straight bore collimator. To ascertain
quantitatively the amount of activity present in the head of each patient, a semi-circular …

Rhenium-188-Labeled DTPA: a new radiopharmaceutical for intravascular radiation therapy

BT Hsieh, JF Hsieh, SC Tsai, WY Lin, HT Huang… - Nuclear medicine and …, 1999 - Elsevier
Balloon angioplasty is a standard treatment for artherosclerotic coronary artery disease.
However, its clinical value is reduced by a high restenosis rate. A new concept in preventing …

[PDF][PDF] Cisternography with 169Yb-DTPA

FH DeLand, AE James, HN Wagner… - Journal of Nuclear …, 1971 - Soc Nuclear Med
METHODS In the majority of cases, the radiopharmaceutical was injected into the lumbar
intrathecal space. Radio nucide images of the brain were routinely performed in the anterior …

Unsuccessful tracer injection in radionuclide cisternography revisited

T Horikoshi, Y Asari, A Watanabe, M Uchida… - Annals of nuclear …, 2006 - Springer
Since cerebrospinal fluid (CSF) leakage is highlighted as a cause of persistent headache,
radionuclide cisternography has been increasingly performed in Japan to confirm the …

Ruthenium-97 labeled compounds—a new class of radiopharmaceuticals

SC Srivastava, P Richards, P Som, G Meinken… - Frontiers in Nuclear …, 1980 - Springer
The excellent physical properties of ruthenium-97 (216 KeV γ, 86%) with a half-life of 2.9
days combined with its chemical reactivity make it attractive as a label for versatile new …

[PDF][PDF] 169Yb-DTPA distribution and dosimetry in cisternography

RL Morin, VA Brookeman - Journal of Nuclear Medicine, 1974 - Soc Nuclear Med
MATERIALS AND METHODS Sixteen patients, who were referred to the Nuclear Medicine
Department, VA Hospital, Gainesville, Florida, for routine cisternography were studied …

Radiopharmaceuticals for gamma cisternography

EG Bell, B Maher, JG McAfee… - Radiopharmaceuticals, 1975 - inis.iaea.org
[en] Of the many agents offered for gamma cisternographic evaluation, only two have gained
wide popularity, namely, 131 I-HSA and 111 In-DTPA. On evaluation of these two …

A New Radiopharmaceutical for Cisternogrgphy: Chelated Ytterbium 1691

HN Wagner Jr, F Hosain, FH DeLand, P Som - Radiology, 1970 - pubs.rsna.org
169Yb-DTPA, which has been employed for brain and renal studies, has now been used
safely for cisternography in over 30 patients referred for investigation of hydrocephalus or …