Application of intravenous contrast in PET/CT: does it really introduce significant attenuation correction error?

YY Yau, WS Chan, YM Tam, P Vernon… - Journal of Nuclear …, 2005 - Soc Nuclear Med
The current perception of using contrast-enhanced CT (CECT) for attenuation correction
(AC) is that of caution, as it might lead to erroneously elevated 18F-FDG uptake on the PET …

Cause and magnitude of the error induced by oral CT contrast agent in CT-based attenuation correction of PET emission studies

E Dizendorf, TF Hany, A Buck… - Journal of Nuclear …, 2003 - Soc Nuclear Med
CT images represent essentially noiseless maps of photon attenuation at a range of 40–140
keV. Current dual-modality PET/CT scanners transform them into attenuation coefficients at …

PET/CT with intravenous contrast can be used for PET attenuation correction in cancer patients

AK Berthelsen, S Holm, A Loft, TL Klausen… - European journal of …, 2005 - Springer
Purpose If the CT scan of a combined PET/CT study is performed as a full diagnostic quality
CT scan including intravenous (IV) contrast agent, the quality of the joint PET/CT procedure …

Focal tracer uptake: a potential artifact in contrast-enhanced dual-modality PET/CT scans

G Antoch, LS Freudenberg, T Egelhof… - Journal of nuclear …, 2002 - Soc Nuclear Med
This study was performed to evaluate a possible artifact related to the administration of
intravascular contrast agent in dual-modality PET/CT imaging. Methods: Thirty oncology …

Assessment of errors caused by x-ray scatter and use of contrast medium when using CT-based attenuation correction in PET

MR Ay, H Zaidi - European journal of nuclear medicine and molecular …, 2006 - Springer
Purpose Quantitative image reconstruction in positron emission tomography (PET) requires
an accurate attenuation map of the object under study for the purpose of attenuation …

Optimized intravenous contrast administration for diagnostic whole-body 18F-FDG PET/CT

T Beyer, G Antoch, A Bockisch… - Journal of Nuclear …, 2005 - Soc Nuclear Med
Standard application of CT intravenous contrast agents in combined PET/CT may lead to
high-density artifacts on CT and attenuation-corrected PET. To avoid associated diagnostic …

Quantifying the effect of IV contrast media on integrated PET/CT: clinical evaluation

O Mawlawi, JJ Erasmus, RF Munden… - American Journal of …, 2006 - Am Roentgen Ray Soc
OBJECTIVES. The use of IV contrast media in PET/CT can result in an overestimation of PET
attenuation factors that potentially can affect interpretation. The objective of this study was to …

Acquisition protocol considerations for combined PET/CT imaging

T Beyer, G Antoch, S Müller, T Egelhof… - Journal of Nuclear …, 2004 - Soc Nuclear Med
Since its introduction in 1998, dual-modality PET/CT imaging has received great attention in
the medical community. For the first time, patients can be examined with both CT and PET in …

Standardised uptake values from PET/CT images: comparison with conventional attenuation-corrected PET

M Souvatzoglou, SI Ziegler, MJ Martinez… - European journal of …, 2007 - Springer
Abstract Purpose In PET/CT, CT-derived attenuation factors may influence standardised
uptake values (SUVs) in tumour lesions and organs when compared with stand-alone PET …

Limitations of CT During PET/CT

MJ Gollub, R Hong, DM Sarasohn… - Journal of Nuclear …, 2007 - Soc Nuclear Med
Our aim was to determine the diagnostic limitations of low-dose, unenhanced CT scans
performed for anatomic reference and attenuation correction during PET/CT. Methods: The …