[PDF][PDF] Radionuclide assessment of peripheral hemodynamics: a new technique for measurement of forearm blood volume and flow

Y Todo, M Tanimoto, T Yamamoto… - Journal of nuclear …, 1986 - Soc Nuclear Med
Hemodynamics: A New Technique Page 1 eripheral capacitance and resistance vessels act as
preload and aftenload for the heart and influence cardi ac function. Accordingly, evaluation of …

[PDF][PDF] Measurement of the regional distribution of arterial blood flow in the human forearm and hand

PA Bardfeld, V Lopez-Majano… - Journal of Nuclear …, 1967 - Soc Nuclear Med
In measuring the perfusion of an organ or region of the body, it is important to consider the
distribution of blood flow within the organ or region as well as the total blood flow …

[PDF][PDF] Forearm blood flow measurements using technetium-99m human serum albumin following brachial arteriotomy

A Parkin, SW Smye, N Bishop… - Journal of nuclear …, 1989 - Soc Nuclear Med
Forearm Blood Flow Measurements Using Technetium-99m Human Serum Albumin
Following Brachial Arteriotomy Page 1 etrograde catheterization of the coronary arteries …

Radionuclide limb blood flow measurements to resolve diagnostic problems in vascular surgery

A Parkin, J Maughan, PJ Robinson… - Nuclear medicine …, 1994 - journals.lww.com
This paper describes the application of radionuclide limb blood flow measurements in 60
patients presenting to the vascular surgeons with exercise-induced leg pain. All patients …

[CITATION][C] The blood supply of the bones of the forearm and hand

PG Laing - Surgical Clinics of North America, 1960 - Elsevier
IT IS becoming increasingly apparent that the surgeon who operates on bones must be
aware that they are living organs with a blood supply of their own. As with any other organ …

[CITATION][C] Peripheral blood flow of forearm in normal subjects evaluated by plethysmography and 133Xe clearance at rest and during hyperaemia

P Lehtovirta, A Rekonen - 1974 - pascal-francis.inist.fr
PERIPHERAL BLOOD FLOW OF FOREARM IN NORMAL SUBJECTS EVALUATED BY
PLETHYSMOGRAPHY AND 133XE CLEARANCE AT REST AND DURING HYPERAEMIA …

The clinical application of forearm and hand blood flow measurements using a gamma camera

A Parkin, D Phil, D Wilkinson, SW Smye, PJ Robinson… - Surgery, 1989 - surgjournal.com
A new method of measuring blood flow to forearms and hands during reactive hyperemia is
described. Subjects are positioned with forearms and hands over a gamma camera, and the …

[PDF][PDF] Measurement of blood flow and volume in the forearm of man; with notes on the theory of indicator-dilution and on production of turbulence, hemolysis, and …

R Andres, KL Zierler, HM Anderson… - The Journal of …, 1954 - Am Soc Clin Investig
PRODUCTION OF TURBULENCE, HEMOLYSIS, AND VASO- Page 1 MEASUREMENT OF
BLOOD FLOW AND VOLUMEIN THE FOREARM OF MAN; WITH NOTES ON THE THEORY …

Radionuclide limb blood flow in peripheral vascular disease: a review of 1100 measurements

A Parkin, PJ Robinson, D Martinez… - Nuclear medicine …, 1991 - journals.lww.com
Radionuclide limb blood flow measurements using 99 Tc m-labelled human serum albumin
and a gamma camera have been performed on normal volunteers and on patients with …

Measurement of muscle blood flow in the human forearm with radioactive krypton and xenon

GB HOLZMAN, HN WAGNER JR, M IIO, D Rabinowitz… - Circulation, 1964 - Am Heart Assoc
Measurement of Musele Blood Flow in the Human Forearm with Radioactive Krypton and
Xenon Page 1 Measurement of Musele Blood Flow in the Human Forearm with Radioactive …