Comparison of Rotation-based and Non-rotation-based Projectors for Image reconstruction in Mini-EXPLORER II

Y Lv, D Hu, S Tang, Y Dong - 2018 - Soc Nuclear Med
584 Objectives: Mini-Explorer II is a high-resolution, high sensitivity PET/CT scanner which
is designed for human brain imaging and companion animal imaging. It is the prototype of …

Image Quality evaluation of analytic reconstruction algorithms for long axial field-of-view PET scanner

Y Zhao, Z Deng, Y Lv, D Hu, Y Ding, Y Dong - 2019 - Soc Nuclear Med
240 Objectives: Analytic reconstruction algorithm such as Filtered backprojection (FBP) was
computationally efficient and considered to be quantitatively accurate for PET imaging …

Modeling the spatially-variant point spread function in a fast projector for improved fully-3D PET reconstruction

J Engle, D Kadrmas - 2007 - Soc Nuclear Med
1742 Objectives: The point spread function (PSF) in PET is spatially-variant and becomes
asymmetric away from the center of the tomograph. Modeling the PSF during iterative …

The rotate-and-slant projector for PET: Fully-3D OSEM as fast as FORE 2D-OSEM

D Kadrmas - 2007 - Soc Nuclear Med
319 Objectives: One of the greatest challenges facing iterative fully-3D PET reconstruction is
the issue of long reconstruction times due to the large data size as compared to 2D mode. A …

A virtual-pinhole PET device for enhancing contrast recovery and improving lesion detectability of a one-meter-long PET scanner

J Jiang, J Hua, H Wang, Y Chen, YC Tai - 2022 - Soc Nuclear Med
3319 Introduction: This work presents a Monte Carlo simulation study to demonstrate that
the contrast recovery coefficients (CRC) and detectability of small lesions of a one-meter …

Virtual-pinhole PET

YC Tai, H Wu, D Pal, JA O'Sullivan - Journal of Nuclear Medicine, 2008 - Soc Nuclear Med
We proposed and tested a novel geometry for PET system design analogous to pinhole
SPECT called the virtual-pinhole PET (VP-PET) geometry to determine whether it could …

Micro insert: A prototype full-ring PET device for improving the image resolution of a small-animal PET scanner

H Wu, D Pal, TY Song, JA O'Sullivan… - Journal of nuclear …, 2008 - Soc Nuclear Med
A full-ring PET insert device should be able to enhance the image resolution of existing
small-animal PET scanners. Methods: The device consists of 18 high-resolution PET …

An evaluation of resolution recovery performed in projection-space or in image-space for a high-resolution PET scanner

H Baghaei, H Li, Y Zhang, R Ramirez, WH Wong - 2013 - Soc Nuclear Med
2056 Objectives Traditional PET reconstruction methods that do not take into account the
mispositioning of the lines of response (parallax error) result in blurring images and …

Performance evaluation of a large axial field-of-view PET scanner: SET-2400W

T Fujiwara, S Watanuki, S Yamamoto, M Miyake… - Annals of nuclear …, 1997 - Springer
The SET-2400W is a newly designed whole-body PET scanner with a large axial field of
view (20 cm). Its physical performance was investigated and evaluated. The scanner …

Clinical validation of fully 3-D versus 2.5-D RAMLA reconstruction on the Philips-ADAC CPET PET scanner

S Chiang, C Cardi, S Matej, H Zhuang… - Nuclear medicine …, 2004 - journals.lww.com
Materials and methods Ninety patient scans acquired on the Philips CPET scanner at our
institution were reconstructed using 2.5-D RAMLA and 3-D RAMLA with differing …