[PDF][PDF] Detection of subacute infectious foci with indium-111-labeled autologous leukocytes and indium-111-labeled human nonspecific immunoglobulin G: a …

WJG Oyen, RAMJ Claessens, JWM van der Meer… - 1991 - repository.ubn.ru.nl
Study Design Since both radiopharmaceuticals were labeled with'" In, the investigations had
to be separated in time to allow clearance of the radiopharmaceutical that was administered …

Indium-111-labeled human nonspecific immunoglobulin G: a new radiopharmaceutical for imaging infectious and inflammatory foci

WJG Oyen, RAMJ Claessens… - Clinical infectious …, 1992 - academic.oup.com
Indium-111-labeled human nonspecific immunoglobulin G (111In-IgG) is a newly developed
radiopharmaceutical for imaging infectious and inflammatory foci. This article presents an …

Detection of acute inflammation with 111In-labeled nonspecific polyclonal IgG

AJ Fischman, RH Rubin, BA Khaw, RJ Callahan… - Seminars in Nuclear …, 1988 - Elsevier
The detection of focal sites of inflammation is an integral part of the clinical evaluation of the
febrile patient. When anatomically distinct abscesses are present, lesion detection can be …

Dynamic distribution and dosimetric evaluation of human non-specific immunoglobulin G labelled with 111In or 99Tcm

W Buijs, WJG Oyen, ETM Dams… - Nuclear medicine …, 1998 - journals.lww.com
This study presents data on the dynamic distribution and dosimetry of 111 In-and 99 Tc m-
labelled human non-specific immunoglobulin G (IgG), two recently developed …

[PDF][PDF] The efficacy of indium-111-polyclonal IgG for the detection of infection and inflammation

FL Datz, CE Anderson, R Ahluwalia… - Journal of Nuclear …, 1994 - Soc Nuclear Med
I 1@ IgO study; biopsy, surgery, additional nuclear medicinescansand
radiOgraphICstudieswereusedto confirm the lgG scan results. Resufts: The polydonal lgG …

Dissociation of indium from indium-111-labelled diethylene triamine penta-acetic acid conjugated non-specific polyclonal human immunoglobulin G in inflammatory …

RAMJ Claessens, EB Koenders, OC Boerman… - European journal of …, 1995 - Springer
Several investigators have reported retention of indium-111 in infectious foci after
intravenous injection of 111 In-labelled immunoglobulin G (IgG). With this study we intended …

Imaging of focal inflammation with 99Tcm-labelled human polyclonal immunoglobulin G

ASW Goh, SE Aw, FX Sundram, ES Ang… - Nuclear Medicine …, 1990 - journals.lww.com
A 99 Tc m-based radiopharmaceutical for detecting focal inflammation would present
several advantages over 67 Ga citrate or 111 In leucocytes, ie rapid availability in the acute …

[PDF][PDF] Diagnosing infection in febrile granulocytopenic patients with indium-III-labeled human immunoglobulin G

WJG Oyen, RAMJ Claessens, JMM Raemaekers… - 1992 - repository.ubn.ru.nl
Purpose: Delineation of focal infection is a major prob lem in the management of febrile
granulocytopenic pa tients. The utility of indium-111—labeled human nonspe cific …

[PDF][PDF] Infectious imaging with indium-111-labeled nonspecific polyclonal human immunoglobulin

WA Wegener, MG Velchik, D Weiss, S Ter… - Journal of Nuclear …, 1991 - Soc Nuclear Med
Infectious Imaging with Indium-.111-Labeled Nonspecific Polyclonal Human
Immunoglobulin Page 1 tivity and specificity for the detection of abdominal infec tion. Indium-l …

Clinical evaluation of a scintigraphic method for diagnosing inflammations/infections using indium-111-labeled nonspecific human IgG.

AN Serafini, I Garty, R Vargas-Cuba… - Journal of Nuclear …, 1991 - europepmc.org
This study was undertaken as part of a Phase II study to assess the sensitivity and safety of
111In-DTPA-human IgG, an imaging agent for the detection of inflammations and/or …