[PDF][PDF] Discordant Technetium-99m-MIBI and Technetium 99m-HMPAO Uptake of Recurrent Occipital Meningioma on Brain SPECT Images

WJ Shih, JK Lee, P Milan - Journal of Nuclear Medicine, 1996 - Soc Nuclear Med
DISCUSSION Two separate radionuclide cerebral angiograms showed in creased
radioactivity in the cerebrum with recurrent meningio mas during the arterial phase. When …

Multicentric meningioma evaluation with Tc-99m MIBI SPECT, CT, and MRI

F Cesani, R Ernst, G Storey… - Clinical nuclear …, 1995 - journals.lww.com
Menlngiomas comprise 15% of adult intracranial tumors. They are often found in
middle-aged adults and are more likely to occur in women. They are frequently located in …

[PDF][PDF] Dynamic SPECT with iodine-123 IMP in meningiomas

S Nakano, K Kinoshita, S Jinnouchi… - Journal of nuclear …, 1988 - Soc Nuclear Med
Dynamic SPECT with Iodine-123 IMP in Meningiomas Page 1 -isopropyl-p-[123I]iodoamphetamine
([â€23I]IMP), a lipophilic tracer, is distributed in correlation to re gional cerebral blood flow (rCBF) …

Tc-99m MIBI brain SPECT of cerebellopontine angle tumors

CH Park, R Sataloff, M Richard, J Zhang… - Clinical nuclear …, 1996 - journals.lww.com
To prospectively evaluate the imaging feasibility of Tc-99m sestamibi brain SPECT of
cerebellopontine angle (CPA) tumors, seven patients with CPA lesions seen on CT or MRI …

Dynamic SPECT with technetium-99m HM-PAO in meningiomas--a comparison with iodine-123 IMP.

S Nakano, K Kinoshita, S Jinnouchi… - Journal of Nuclear …, 1989 - europepmc.org
Technetium-99m hexamethylpropyleneamine oxime ([99mTc] HM-PAO) has recently been
introduced as an alternative to N-isopropyl-p-[123I] iodoamphetamine ([123I] IMP) for …

Tc-99m MIBI brain SPECT in the diagnosis of recurrent glioma

CH Park, SM Kim, JJ Zhang, CM Intenzo… - Clinical nuclear …, 1994 - journals.lww.com
Tc-99m MIBI Brain SPECT in the Diagnosis of Recurrent Glioma : Clinical Nuclear Medicine
Tc-99m MIBI Brain SPECT in the Diagnosis of Recurrent Glioma : Clinical Nuclear Medicine …

Tc-99m-MIBI and Tc-99m-HMPAO accumulation in primary and metastatic brain tumors assessed by brain SPECT

M Sygitowicz, P Lass, P Lyczak… - Neurologia i …, 1998 - europepmc.org
Imaging of intracranial lesions is frequently difficult in CT/MRI diagnosis. The introduction of
the encephalic tracer MIBI seemed to be a promising alternative. We tried to compare the …

A Case of meningioma with non-accumulation of 99mTc-ECD and increased accumulation of 99mTc-HMPAO in the tumor

A Kashimada, K Machida, N Honda… - Kaku igaku. The …, 1992 - europepmc.org
99mTc-ECD SPECT and 99mTc-HMPAO SPECT with or without Matas test were performed
in a 62-year-old woman with meningioma in the left anterior cranial fossa. After injection of …

False-positive indium 111 pentetreotide scan for recurrent meningioma due to radiation fibrosis

S Rahman, S Raja, BL Ehni - Clinical Nuclear Medicine, 2011 - journals.lww.com
A patient with recurrent meningioma in the right frontal lobe, treated with resection and
radiation, had a routine magnetic resonance imaging scan that was suspicious for recurrent …

Increased uptake of technetium-99m-hexamethylpropyleneamine oxime related to primary leptomeningeal melanoma

T Sagiuchi, K Ishii, S Utsuki, Y Asano… - American journal …, 2002 - Am Soc Neuroradiology
We present an autopsy case of primary leptomeningeal melanoma visualized with
technetium-99m-hexamethylpropyleneamine oxime (Tc-99m-HMPAO) single photon …